Smith Meter AccuLoad IV-QT Hardware Worksheet

Similar documents
Smith Meter AccuLoad III AccuLoad III-S and N4 Hardware Worksheet

Electronic Preset Delivery System Smith Meter AccuLoad III. Vapor Recovery. Vapor Recovery System. Overview

Meter, PD Series, K12-S1, S3, S5, S6 and S7

Counters, Printers, Preset Counters

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14)

Transmitter, Model UPT

Micro Valve. Quick, Sure Response with Design Adaptability. Features and Benefits. Applications. Dependable Performance SPECIFICATIONS / PARTS LIST

3" Steel Model E3. We put you first. And keep you ahead.

Model DE-3 Air Release Heads Parts List

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

Tools, Mechanical. All or Multiple Products. Parts List. Feeler Gauges. Spiders and Bushings. Feeler Gauge Extension Rod. Cam Setting Bushing

Genesis Series 2" and 3" Steel Meters

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement

Smith Meter PD Meters 3" Steel Model E3

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List

Transmitter, Model UPT

Smith Meter Rotary Vane PD Meters Single and Double Case PD Meters Installation / Operation / Maintenance Manual

PRIME 4 Service. Smith Meter Rotary Vane Meters. Contents

Smith Meter TM Turbine Meters Models 3" Through 16" MV Series Service

Densitometers L-Dens 427F Ex Density Sensor Specifications

OrificeMaster Specifications

Electronic Preset Delivery System Smith Meter AccuLoad III to IV. Upgrade Manual for AccuLoad III Models S and Q MANUAL

Smith Meter Truck Meter Packages Specifications

Issue/Rev. 0.3 (2/04) Bulletin P

Smith PD Rotary Vane Meters F4 PRIME Cover Field Retrofit Procedure Service Bulletin

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List

Sening MultiFittings. One Stop Shop for Tank Truck Fittings. Advantages:

Model G6-S3. Repeatability ±0.02%

Flow Research and Test Center

Non Ferrous Aircraft Fueling Meters

Smith Meter TM Turbine Meters Models 4" Through 24" Sentry TM Series. Service. Contents

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

For reliable control of small, large or multi-system-type lubrication systems

SCC Inc. FLMTR Series. Installation Instructions Document No. LV February 21, KT-BMK-PLC Gas Flow Meter Kits for Flow Totalization

RCM - Direct Reading Flowmeters

Flow Research and Test Center. Creating resource technology for today and tomorrow.

Fusion4 MicroBlender (ATEX/IECEx) The intelligent blend controller for all single stream blending applications.

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

CENTRIFEEDER ELECTRONICS

mass flowmeter for compressed air

2007-UP NAVIGATION INTERFACE MODULE (Infiniti/Nissan)

Armstrong In-Line and Insertion Vortex Flow Meters

Let s keep it simple. Electronic Valves

mass flowmeter for compressed air

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Multivariable Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

Smith Meter TM PD Rotary Vane Meters F4-S1/A1-S3/A3 PRIME Upgrade Upgrade and Service

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

80V 300Ah Lithium-ion Battery Pack Data Sheet

Multivariable Vortex Flow Meter

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

Octave Water Meter Installation Manual

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES

4 Redundant Control System

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

DPS Telecom Your Partners in Network Alarm Management

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

RCM. Direct Reading Flowmeter. for Liquids or Gases

Monitoring Health of External Solenoid Valve (SOV) with FIELDVUE DVC6200 SIS Digital Valve Controllers

5. Control System CONTROL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-27

Load Weighing Devices

ILC PICO-MAX ELECTRIC GREASE PUMP Automatically Lubricates Small, Medium and Large Machinery

Dissolved Oxygen Measurement System with Air Blast Cleaner

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

To ensure proper installation, digital pictures with contact information to before startup.

DA 15 T 06 BLDC 1000 DA 15 T 12 BLDC 1000

F-2600 SERIES INLINE VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

INSTALLATION INSTRUCTIONS. Revision 4.0.3

RVS-DN Digital Reduced Voltage Motor Starter

CML Electric Actuator for Baumann Series

Vortex Flow Meter Model DVH

Service Manual. 854E Diesel Engine. Specifications. 854E model is for FD70N Chassis Service Manual B101

Upgrade your blow molding machine with one of our two new state of the art machine control systems.

Fusion4 BioBlend (FM/UL/CSA) The intelligent blend controller for all multiple stream blending applications.

5. Control System CONTROL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL FU(H4DOTC)-29

Flex Amplifiers Installation Instructions

Redundant Control System

Version 1.0 Copyright DC-RPM-iBox User Manual

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES

ISTEC MAGNETIC METERS

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

DPT TARGET TYPE FLOWMETERS

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

Paddle-wheel flow controller with optical principle for On/Off control

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Transcription:

APPLICATION BULLETIN Smith Meter AccuLoad IV-QT Hardware Worksheet Bulletin AB06213 Issue/Rev. 0.0 (4/17) This worksheet is being provided to ensure that the AccuLoad IV-QT hardware contains enough I/O for the application. This sheet should be filled out for every application. The AccuLoad IV-QT hardware is capable of controlling up to six arms in straight arm loading applications, and up to six products per arm in sequential blending and/or ratio blending applications. When configured for ratio blending, the AccuLoad IV-QT is capable of controlling six product streams. Contact your local Smith Meter representative if you have any questions about this worksheet. Pulse Inputs Product Meter Pulses (Maximum six meters) 1 2 3 4 5 6 7 8 9 10 11 12 (For dual pulse meters, 2 per meter) Density 1 2 3 4 5 6 Additive Meter 1 2 3 4 Flow Controlled Additive Meter (Maximum 4 meters) 1 2 3 4 5 6 7 8 14 or less (For dual pulse meters, 2 per meter) Note: Boards can be added to provide additional pulse inputs for additive meters. One board adds 10 additional additive meter inputs. A second board adds 10 more additive meter inputs, for a total of 20 additional additive meters. Flow Controlled Additives must be wired to the A4M or A4B boards. Analog Inputs RTD (Temperature) 1 2 3 4 5 6 4-20 ma (Temperature, Density, Pressure, General) 1 2 3 4 5 6 1-5 Vdc (Temperature, Density, Pressure, General) 1 2 3 4 5 6 Analog Outputs 4-20 ma (Valve Control, Flow Rate, General) 1 2 3 4 5 6 1-5 Vdc (Valve Control, Flow Rate, General) 1 2 3 4 5 6 Analog Inputs and Outputs 6 or less

AC Digital Inputs Security 1 2 Arm Permissive (Maximum 2 per arm) 1 2 3 4 5 6 7 8 9 Second High Flow Rate (1 per arm) 1 2 3 4 5 6 Remote Start Arm 1 2 3 4 5 6 Remote Stop 1 Remote Stop Arm 1 2 3 4 5 6 Transaction Reset (1 per arm) 1 2 3 4 5 6 General Purpose 1 2 3 4 5 6 7 8 9 Print Tray Switch 1 2 3 4 5 6 Block Valve Feedback 1 2 3 4 5 6 7 8 9 Piston Injector Feedback 1 2 3 4 5 6 7 8 9 System Permissive 1 2 3 Swing Arm Side A 1 2 3 4 5 6 Swing Arm Side B 1 2 3 4 5 6 DE Head Stop Flow 1 2 3 4 5 6 DE Head Low Flow 1 2 3 4 5 6 DE Head High Flow 1 2 3 4 5 6 Bay A Permissive 1 2 Bay B Permissive 1 2 Meter Injector Prove 1 9 or less 2 Bulletin AB06213 Issue/Rev. 0.0 (4/17)

DC Digital Inputs Security 1 2 Arm Permissive (Maximum 2 per arm) Second High Flow Rate (1 per arm) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 Remote Start Arm 1 2 3 4 5 6 Remote Stop 1 Remote Stop Arm 1 2 3 4 5 6 Transaction Reset (1 per arm) 1 2 3 4 5 6 General Purpose 16 17 18 19 20 21 22 23 24 34 Print Tray Switch 1 2 3 4 5 6 Block Valve Feedback Piston Injector Feedback 16 17 18 19 20 21 22 23 24 34 16 17 18 19 20 21 22 23 24 34 System Permissive 1 2 3 Swing Arm Side A 1 2 3 4 5 6 Swing Arm Side B 1 2 3 4 5 6 DE Head Stop Flow 1 2 3 4 5 6 DE Head Low Flow 1 2 3 4 5 6 DE Head High Flow 1 2 3 4 5 6 Bay A Permissive 1 2 Bay B Permissive 1 2 Meter Injector Prove 1 14 or less standard 24 or less with one optional A4I board 34 or less with two optional A4I boards Note: Eight shared digital I/O points are programmable between DC digital inputs and DC digital outputs. The number indicated here is the maximum if all programmed as inputs or all programmed as outputs. Bulletin AB06213 Issue/Rev. 0.0 (4/17) 3

AC Digital Outputs Product Pumps (Sequential Blending, 1 per arm) 1 2 3 4 5 6 Upstream Solenoids 2 1 2 3 4 5 6 Downstream Solenoids 2 1 2 3 4 5 6 Arm Relay 1 2 General Purpose Block Valve Feedback 16 17 18 19 20 21 22 23 24 25 26 27 67 16 17 18 19 20 21 22 23 24 25 26 27 36 Stop Relay (1 per arm) 1 2 3 4 5 6 Additive Pumps 1 16 17 18 19 20 21 22 23 24 Piston Injectors 16 17 18 19 20 21 22 23 24 Metered Injectors (Solenoids) 1 1 2 3 4 5 Shared Additive Solenoids 16 17 18 19 20 21 Shared Additive Flush 1 2 3 4 Flow Controlled Additive Upstream Solenoid 2 1 2 3 4 Flow Controlled Additive Downstream Solenoid 2 1 2 3 4 27 or less standard 47 or less with one optional A4I board 67 or less with two optional A4I boards 1 Additive pumps and solenoid outputs are fixed on the A4I when more than 4 metered additives are programmed. It is recommended that if the A4I board is required for additional metered additives, that all additives be connected to the A4I board. 2 Upstream and downstream solenoids should be programmed and wired on A4M / A4B AccuLoad board sets (must be the same board as associated meter pulse input). 4 Bulletin AB06213 Issue/Rev. 0.0 (4/17)

DC Digital Outputs Product Pumps (Sequential Blending, 1 per arm) 1 2 3 4 5 6 Upstream Solenoids 2 1 2 3 4 5 6 Downstream Solenoids 2 1 2 3 4 5 6 Alarm Relay 1 2 General Purpose 1 2 3 4 5 6 7 8 9 10 11 Block Valve 1 2 3 4 5 6 7 8 9 10 11 Stop Relay (1 per arm) 1 2 3 4 5 6 Additive Pumps 3 1 2 3 4 5 6 7 8 9 10 11 Piston Injectors 1 2 3 4 5 6 7 8 9 10 11 Metered Injectors (Solenoids) 1 2 3 4 Shared Additive Solenoids 1 2 3 4 5 6 7 8 9 10 11 Shared Additive Flush 1 2 3 4 Flow Controlled Additive Upstream Solenoid 2 1 2 3 4 Flow Controlled Additive Downstream Solenoid 2 1 2 3 4 11 or less 2 Upstream and downstream solenoids should be programmed and wired on A4M / A4B AccuLoad board sets (must be the same board as associated meter pulse input). 3 Additive pumps and solenoid outputs are fixed on the A4I when more than 4 metered additives are programmed. 4 Eight shared digital I/O points are programmable between DC digital inputs and DC digital outputs. The number indicated here is the maximum if all programmed as inputs or all programmed as outputs. Bulletin AB06213 Issue/Rev. 0.0 (4/17) 5

AccuLoad IV-QT Model Number (Refer to Specification Sheet SS06200) ALIV-QT-XP A XXXXX ARM1 Digit 1: # of RTDs Digit 1: # of A4I Boards (0-2) ARM2 ARM3 ARM4 ARM5 ARM6 Digit 2: # of 4-20 ma inputs Digit 3: # of 4-20 ma inputs Digit 4: # of 1-5 Vdc inputs Digit 5: # of 1-5 Vdc outputs The AccuLoad IV-QT hardware is capable of having either local or remote A4I board(s). When using the A4I board, it is recommended that it be mounted at or near the additive injector panel to save on wiring costs. All that is needed back to the AccuLoad IV is +24 Vdc power and a communication cable. Consideration should be given to mounting the A4I in the remote housing any time the additive panel is a considerable distance away from the AccuLoad. The cost of running +24 Vdc power and one communication wire versus the remote housing and all the additive wiring should be considered. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at TechnipFMC.com and click on the Contact Us link. TechnipFMC.com TechnipFMC 2017 All rights reserved. AB06213 Issue/Rev. 0.0 (4/17) TechnipFMC FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101 304.0