CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

Similar documents
CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

Pre-assembled distribution manifolds for radiant panel systems

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

FLOW RATE STATIC BALANCING Valves for radiators

CT3202.0_01 EN February 2018

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

Connection and regulation kit for HVAC terminal units

Art.918C Pre-assembled manifold with flow meters, air

THERMOSETTER Recirculation thermal balancing valve

MANIFOLDS AND DISTRIBUTION EQUIPMENT

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

Pressure Independent Control Valve

Preassembled manifolds with flow meter, series CPRFL

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Components for central heating

Product Information. Brass Manifolds. Version A

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

WAY MOTORISED COMPACT ZONE VALVES

Safety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

485 - NC NO/DA DN

T2 Wall Hung Radiator & UFH Manifolds

PNEUMATICALLY ACTUATED 2-WAY

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

Floor heating manifold with automatic flow control

RTL. Floor Heating Controller Return temperature limiter with and without presetting

dynacon floor heating manifold with automatic flow control

CHOOSING YOUR MANIFOLD & LOCATION

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

132 Series. QuickSetter Balancing Valve with flow meter NA Function

HERZ-Motorised flow controler

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

K35 HeatBloC with 3-temperature mixing valve

Fan-coil valves Series

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

Installation, commissioning and servicing instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

FCU Floor Control Unit

TECHNICAL CATALOGUE BALL VALVES: PARIS

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA

Section 1 - Sanitary Manifolds

SELF-CLEANING FILTER

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN

PCS. HVAC Products. Technical submission. Type of Product

3-Port Seat Valves with Male Thread, PN 16

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Products for underfloor heating

LK Manifold RF. Design. Requirements. Documentation

MrPEX 1 ½ " Brass Manifold Installation Guide

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

Process Multi-Rheo Filter PMRF

COMPLETE CONTROL IN YOUR HANDS MODULAR MANIFOLDS - QUICKER, EASIER AND MORE STRAIGHTFORWARD TO INSTALL

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

Direct/Factory Mounting Valve Set

THERMOSTATIC CONTROL HEADS:

Mikrotherm F. Manual Radiator Valves With presetting

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

PRESSURE CONTROL VALVES SABS 198

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series

TDU.3 floor distribution unit SK

Section 20. HVAC Valves & Products

2-port and 3-port ball valves PN 40

TECHNICAL CATALOGUE BALL VALVES: IDEAL

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

Terminator PICV. Technical Manual

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

VE-S_15-32 Pressure Independent Balancing & Control Valves

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

VKD DN PP-H. DUAL BLOCK 2-way ball valve

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

Transcription:

Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally distribute the thermal medium in underfloor heating system circuits, in order to improve the control of the panel thermal emission. This series of manifolds is composed of: - flow manifold complete with built-in flow meters and balancing valves, with indicators that can be cleaned and replaced with the system operating; - return manifold complete with shut-off valves fitted for thermoelectric actuator; - end fittings complete with automatic and manual air vent with fill/drain cocks; - LCD thermometers, on the flow and return manifolds. In addition, this manifold is supplied complete with special mounting brackets which, during installation, allow the centre distance of the main flow and return connections to be adjusted easily. Product range 664 series Distribution manifold for radiant panel systems size 1 Technical specifications Materials Flow manifold Body: brass EN 1982 CB753S Flow rate balancing valve: Stem and obturator: PA Hydraulic seals: EPDM Protective cover: ABS Spring: stainless steel EN 10270-3 (AISI 302) Return manifold Body: brass EN 1982 CB753S Shut-off valve: Headwork: brass EN 12164 CW614N Obturator stem: stainless steel EN 10088-3 (AISI 303) Obturator: EPDM Spring: stainless steel EN 10270-3 (AISI 302) Hydraulic seals: EPDM Cap: ABS Brackets and supports: PA6G30 Performance Medium: water, glycol solutions Max. percentage of glycol: 30% Maximum working pressure: 6 bar Working temperature range: 5 60 C Liquid crystal digital thermometer scale: 24-48 C Flow meter scale: 0 5 l/min Accuracy: ±10% Main connections: 1 F (ISO 228-1) Outlets: M - Ø 18 Centre distance: 50 mm

Dimensions 6646B1 6646C1 6646D1 6646E1 6646F1 6646G1 6646H1 6646I1 6646L1 6646M1 6646N1 6646O1 No. of outlets 2 3 4 5 6 7 8 9 10 11 12 13 Total L (A) 165 215 265 315 365 425 475 525 575 625 675 735 Mass (kg) 2 2,4 2,8 3,4 3,8 4,1 4,8 5,5 6 6,9 7,2 7,7 5 2 1 4 3 Characteristic components 1 Flow manifold with built-in flow meters and flow rate balancing valves 2) Return manifold complete with shut-off valves fitted for thermo-electric actuator 3) End fittings complete with manual and automatic air vents, double radial end fitting and drain cocks with plugs 4) Pair of mounting brackets for box or wall installation 5) Upper and lower manifold supports for brackets; may be assembled using quick pushfit system

Construction details Flow manifold The flow manifold is equipped with built-in flow meters and flow rate balancing valves (1). Using the balancing valve the flow rate to the individual circuits can be adjusted accurately as required, with the setting being read directly from the single flow meter with a scale of 0 5 l/min. This simplifies and speeds up the circuit setting process, with no need for reference graphs. After balancing, the valve can be locked in its open position by means of its protective cover. The valve itself makes it possible to shut-off each individual circuit, if necessary. 1 Return manifold The return manifold is equipped with manual shut-off valves (1), in order to cut off the flow to the individual circuits. They can also be fitted with a thermo-electric actuator (2) that, when used with a room thermostat, maintains the ambient temperature at the set values in spite of thermal load variations. The obturator stem (3) consists of a single piece of ground stainless steel, in order to minimise friction and prevent building up of dangerous limescale deposits. The headwork (4) has a double EPDM O-Ring seal (5) (6) on the sliding stem. The EPDM obturator (7) is shaped so as to optimise the hydraulic characteristics of the valve and minimise the noise caused by the flow of the medium, also during the progressive opening or closing action when operating with thermo-electric actuator. 1 2 5 4 6 3 7 Flow meters cleaning or replacement with circuit in operation The flow meter indicators, supplied with the flow manifold, are easily removed for cleaning or replacement purposes without having to empty the system (spare part code R69913). The setting position indicator makes it possible to rebalance the circuit correctly at the design flow rate after maintenance operations. Return manifold end fitting The automatic air vent automatically expels the air accumulating in the circuits of the air conditioning system. It is equipped with a hygroscopic safety cap (1) that prevents water from getting out in order to protect the installation. 1

Digital thermometers Both sides of the flow and return manifold body are equipped with LCD thermometers, with 24 48 C temperature range. The LCDs automatically illuminate green in correspondence with the measured temperature value to ensure easy reading even in low light conditions. This thermometer is calibrated to display the actual temperature of the medium, which is essential in evaluating the operating conditions and thermal load of the system. Adjustable manifold centre distances Each bracket has a series of slots so that the manifold supports can be attached manually. This means that the entire unit can be mounted quickly and that the main centre distances of the manifold can be adjusted depending on the installation needs. A Replaceable components The headwork of the balancing valve with flow meter and the shutoff valve can be removed and replaced with spare parts. A Manifold brackets mounting The manifolds are easily mounted onto the brackets (1) using the modular supports (2) supplied, without the aid of mounting accessories (nuts and spanners). 1 2

Hydraulic characteristics In order to determine the hydraulic characteristics of the circuit, it is necessary to calculate the total head loss suffered by the flow rate of medium on passing through the devices forming the manifold assembly and the radiant panel circuits. From a hydraulic point of view, the system consisting of the manifold assembly and the circuits can be represented as a set of hydraulic elements arranged in series and in parallel. Δp Tot. DpTot. = Total head loss across the manifold (Flow + Return + Loop) BV LOOP SV DpBV = Localized loss at loop balancing valve (loop flow rate) DpLoop = Loop head loss (loop flow rate) Δp Manif. F Δp Manif. F DpSV = Localized loss at panel circuit shut-off valve (loop flow rate) G Tot. G Tot. DpManif. F= Distributed loss of the flow manifold (total flow rate) DpManif. R =Distributed loss of the return manifold (total flow rate) DpTot. = DpBV +DpLoop + DpSV + DpManif. F + DpManif. R (1.1) When the hydraulic characteristics of each component and the design flow rates are known, the total loss can be calculated as the sum of the partial head losses for each specific component in the system, as indicated by the formula (1.1).

Hydraulic characteristics Δp (mm w.g.) BV SV Δp (kpa) Dp (mm w.g.) Flow rate (l/min) (m 3 /h) Flow rate Flow-rate balancing valve fully open (BV) Panel circuit shut-off valve (SV) - Kv = flow rate in m 3 /h for a head loss of 1 bar - Kv0,01 = flow rate in l/h for a head loss of 1 kpa Flow manifold 2 7 outlets Return manifold 2 7 outlets Flow manifold 8 13 outlets Return manifold 8 13 outlets *Average value Example of total head loss calculation Supposing we need to calculate the head loss of a manifold with three circuits with the following characteristics: Total manifold flow rate: 450 l/h The flow rate and head loss of the three loops are as follows: Circuit 1 Circuit 2 Circuit 3 Dp 1 = 10 kpa Dp 2 = 10 kpa Dp 3 = 7 kpa (1.2) G 1 = 120 l/h G 2 = 150 l/h G 3 = 80 l/h Each segment of the formula (1.1) is calculated using the following relationship: Dp = G 2 /Kv 0,01 2 G = flow rate in l/h Dp = head loss in kpa (1 kpa = 100 mm w.g.) Kv 0,01 = flow rate in l/h through the device, which corresponds to a head loss of 1 kpa It should be stressed that the calculation of DpTot. must be carried out taking account of the circuit in which there are the greatest head losses distributed along the entire panel pipe loop. In the case we are examining, the relevant circuit is No. 2. It follows that: Dp BV2 = 150 2 /110 2 = 1,86 kpa Dp Loop2 = 15 kpa Dp SV2 = 150 2 /410 2 = 0,13 kpa Dp Manif. F = 350 2 /1110 2 = 0,1 kpa Dp Manif. R = 350 2 /1670 2 = 0,04 kpa } Values obtained by neglecting the changes due to the flow rate sent to each branch circuit Using formula (1.1), adding up all the calculated terms, we obtain: Dp Tot.= 1,86 + 15 + 0,13 + 0,1 + 0,04 17 kpa Note: Because of the low head losses associated with the manifolds, the two terms relating to them can be disregarded. In general, the total head loss is fairly close to the branched panel circuit head loss.

Using the balancing valves with flow meter The balancing valves in the flow manifold make it possible to balance each individual panel circuit to obtain the design flow rates in each loop. Considering the following data: - medium flow rate across each circuit - head loss generated in each circuit by this flow rate: Dp Circuit = Dp Loop + Dp SV (Dp Shut-off valve ) SYSTEM FLOW BV Δp BV - available head on the panel circuit or predefined head: H Predefined Dp Circuit + = Dp BV + Dp Loop + Dp SV disadvantaged Δp Tot. ΔpCircuit H Predefined ΔpCircuit + disadvantaged Referring to the adjacent diagram, for the loop flow rate the balancing valve must provide an additional head loss equal to the difference Dp BV (Dp Balancing valve ). SYSTEM RETURN SV Flow rate balancing and reading Manually remove the red protective cover from the flow meter. While the system is running, manually adjust the design flow rate using the adjustment nut (1). The flow rate value is indicated by vertical movement of the red indicator disc (2). When the red indicator disc is positioned on the desired flow rate value, set the external indicator (3) in line with the internal indicator disc. 2 3 1 SPECIFICATION SUMMARY 664 series Distribution manifold for radiant panel systems with 2 (from 2 to 13) outlets. Brass body. EPDM seals. Main connections 1 F (ISO 228-1). Centre distances available for main connections: 196 mm, 175 mm, 154 mm, 133 mm and 112 mm. Outlet connections M - Ø 18 threaded, centre distance 50 mm. Medium water and glycol solutions. Maximum percentage of glycol 30%. Maximum working pressure 6 bar. Working temperature range 5 60 C. Complete with: - Flow manifold with flow rate balancing valves and flow meter with 0 5 l/min graduated scale. Accuracy ±10%. - Return manifold complete with shut-off valves fitted for thermo-electric actuator. - Pair of end fittings complete with automatic air vent with hygroscopic cap on the return manifold and manual air vent and plug on the flow manifold. Complete with fill/drain cock. - Pair of mounting brackets for box or wall installation and mountable manifold supports. - Upper and lower manifold supports for brackets; may be assembled using the quick-coupling system.

ACCESSORI Bypass kit End fitting Air vent Drain cock 662010 Off-centre bypass kit fixed setting 25 kpa (2500 mm w.g.) Working temperature range: -10 110 C. 599662 End fitting composed of air vent cock, double radial connection and plug. Max. working pressure: 10 bar. Working temperature range: 5 100 C. Main connection: 1 F. Lower connection: M. Upper air vent connection: 3/8 F. Lower plug connection: 1/2 F. 502033 Automatic air vent. In stamped brass. With hygroscopic safety cap. Max. drain pressure: 2,5 bar. Max. working temperature: 120 C. Connection: 3/8 M. R59681 AQUASTOP Hygroscopic safety cap. For air vents 5020 and 5021 series. 337231 Mini drain cock with metal seal. Adjustable drain. PTFE watertight thread. Max. working temperature: 100 C. Connection: 3/8 M. 538400 Drain cock with hose connection and cap. Max. working temperature: 110 C. Connection: 1/2 M. R69913 1 3/8 1/2 Spare glass with graduated scale for flow meter. Shut-off valves Brackets Fittings 680507 680502 680503 680500 680501 680506 680515 680517 680524 680526 680535 680537 680544 680546 680555 680556 680564 680505 347510 347512 347514 347515 347516 347518 Ø inner 17,5-18,0 17,5-18,0 8,5 19, 19,0 19,5 19,5 10,0 19,5 10,0 10,5 11,0 10,5 11,0 11,5 12,0 11,5 12,0 12,5-13,0 12,5-13,0 13,5 14,0 13,5 14,0 14,5 15,0 15,5 15,5 15,5 16 17 - Ø 10 - Ø 12 - Ø 14 - Ø 15 - Ø 16 - Ø 18 391066 Pair of ball shut-off valves with female-male connections and union with O-ring seal. Working temperature range: 5 100 C. Connection: 1. 658400 Polymer brackets with adjustable centre distance, for manifolds 662 and 664 series. Complete with screws and wall anchors. For use with box 659..4 series (depth 110 140 mm) or directly wall mounted. 680 Self-adjustable diameter fitting for single and multi-layer plastic pipes. Working temperature range: 5 80 C (PE-X) 5 75 C (Multi-layer marked 95 C) Ø outer 10,5 12 12,5 14 12,5 14 14,5 16 12,5 14 14,5 16 14,5 16 16,5 18 14,5 16 16,5 18 16,5 18 18,5 20 16,5 18 18,5 20 18,5 20 18,5 20 18,5 20 22,50 347 Mechanical fitting for annealed copper, hard copper, brass, mild steel and stainless steel pipes. O-Ring seal. Working temperature range: -25 120 C. 386500 Screw plug with nut, for manifold outlets. connection.

Thermo-electric actuators Technical specifications 656102 656104 656112 656114 Voltage (V) 6561 tech. broch. 01042 Thermo-electric actuator for manifolds 662 and 664 series. Normally closed. Materials Protective shell: self-extinguishing polycarbonate Colour: (code 656102/04) white RAL 9010 (code 656112/14) grey RAL 9002 Performance Normally closed Electric supply: V (ac) - 24 V (ac) - 24 V (dc) Starting current: 1 A Running current: V (ac) = 13 ma 24 V (ac) - 24 V (dc) = 140 ma Running power consumption: 3 W Auxiliary microswitch contact rating (code 656112/114): 0,8 A ( V) Protection class: IP 44 (in vertical position) Double insulation construction: Max. ambient temperature: 50 C Operating time: opening and closing from 120 s to 180 s Length of supply cable: 80 cm Thermo-electric actuators with manual opening knob and position indicator 656302 656304 656312 656314 Voltage (V) 6563 tech. broch. 01142 Thermo-electric actuator for manifolds 662 and 664 series. Normally closed. Technical specifications Materials Protective shell: self-extinguishing polycarbonate Colour: (code 656302/04) white RAL 9010 (code 656312/14) grey RAL 9002 Performance Normally closed Electric supply: V (ac) - 24 V (ac) - 24 V (dc) Starting current: 1 A Running current: V (ac) = 13 ma 24 V (ac) - 24 V (dc) = 140 ma Running power consumption: 3 W Auxiliary microswitch contact rating (code 656312/14): 0,8 A ( V) Protection class: IP 40 Double insulation construction: Max. ambient temperature: 50 C Operating time: opening and closing from 120 s to 180 s Length of supply cable: 80 cm Thermo-electric actuator, quick-coupling installation with clip adaptor 656202 656204 656212 656214 656402 656404 656412 656414 Voltage (V) Voltage (V) 6562 tech. broch. 01198 Thermo-electric actuator for manifolds 662 and 664 series. Normally closed. Low power consumption version Technical specifications Materials Protective shell: self-extinguishing polycarbonate Colour: (code 656.02/04) white RAL 9010 (code 656.12/14) grey RAL 9002 Performance Normally closed Electric supply: V (ac) - 24 V (ac) - 24 V (dc) Starting current: (6562) 1 A (6564) 250 ma ( V) Running current: -6562 series: V (ac) = 13 ma; 24 V (ac) - 24 V (dc) = 140 ma -6564 series: V (ac) = 15 ma; 24 V (ac) - 24 V (dc) = 125 ma Running power consumption: 3 W Auxiliary microswitch contact rating (code 656.12/14): 0,8 A ( V) Protection class (fitted in all positions): IP 54 Double insulation construction: Operating time 6562 series Operating time: opening and closing from 120 s to 180 s Aux. microswitch closing time: from 120 s to 180 s Operating time 6564 series Opening time: (80%): 300 s; (100%): 600 s Closing time: 240 s Aux. microswitch closing time: 300 s Length of supply cable: 80 cm

Choice of box size, 659 and 661 series, according to the number of outlets L totale No. of outlets Manifold total length (mm) Box length (mm) Box code, 659 series Box code, 661 series 6646B5 2 190 400 659044 661045 6646C5 3 240 400 659044 661045 6646D5 4 290 400 659044 661045 6646E5 5 340 600 659064 661065 6646F5 6 390 600 659064 661065 6646G5 7 450 600 659064 661065 6646H5 8 500 600 659064 661065 6646I5 9 550 800 659084 661085 6646L5 10 600 800 659084 661085 6646M5 11 650 800 659084 661085 6626N5 12 700 800 659084 661085 6646O5 13 760 1000 659104 661105 Boxes 659 Box for manifolds. Wall or floor installation (with 660 series). Closure with a push-fit clamp. In painted sheet steel. Adjustable depth from 110 to 140 mm. 661 Box for manifolds. Closure with a push-fit clamp. In painted sheet steel. Complete with supports for floor installation. Adjustable depth from 110 to 150 mm. Adjustable height from 270 to 410 mm. (h x w x d) 659044 659064 659084 659104 659124 500 x 1400 x 110-140 500 x 1600 x 110-140 500 x 1800 x 110-140 500 x 1000 x 110-140 500 x 1200 x 110-140 (h x w x d) 661045 661065 661085 661105 661125 500 x 1400 x 110 150 500 x 1600 x 110 150 500 x 1800 x 110-150 500 x 1000 x 110 150 500 x 1200 x 110 150 660040 660060 660080 660100 660120 for 659044 for 659064 for 659084 for 659104 for 659124 660 Floor installation KIT for box, 659 series. Complete with: - 2 supports height cm. 20, - 2 side panels, - 1 pipe-bending bar.

CALEFFEN CALEFFEN Application diagrams Pump Thermostatic valve Shut-off valve Clock Lockshield valve

We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 229 n. 25 28010 Fontaneto d Agogna (NO) Italy Tel. +39 0322 8491 Fax +39 0322 863723 info@caleffi.com www.caleffi.com Copyright 2014 Caleffi