Similar documents
SCTK Splice Connection Termination Kit

ZP-XP Power Connection Kit. Terminator. The Heat Tracing Specialists INSTALLATION PROCEDURES

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

Electric Heat Tracing INSTALLATION PROCEDURES

PETK Power and End Termination Kit

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES HTSXTM BSXTM VSXTM RSXTM KSRTM KSXTM

Terminator ZP/FAK-5 and 5L

Electric Heat Tracing INSTALLATION PROCEDURES

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Products and Accessories. Information Guide

TracePlus. PCA Power Connection Kit INSTALLATION PROCEDURES. PCA-H for BSX, HTSX, KSX, HPT, FP PCA-V for RSX, TSX, VSX

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

Terminator TM DL Lighted Power Connection/End Termination Kit INSTALLATION PROCEDURES. For Power Connection or End Termination Applications

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1 for BSX, RSX, VSX SCTK-2 for KSX, HTSX SCTK-3 for HPT, FP

TracePlus. VIL-6 End of Circuit Light Kit INSTALLATION PROCEDURES. VIL-6-H for BSX, HTSX, KSX, HPT, FP VIL-6-V for RSX, TSX, VSX

Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

PETK Power and End Termination Kit

Terminator DP/FAK-5 and FAK-5L

PETK Power and End Termination Kit

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

TubeTrace Tubing Bundles

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

TSRT TSRT Tee Splice Kit Installation Instructions

Introduction to Heat Trace Cable Systems

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Steam Tracing DESIGN GUIDE

HTSB system System overview

Heating Cable. Description

Heating Cable. Construction

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Power-Limiting Cables

Power Connection Kit installation instructions

Flexible Heaters. Silicone Rubber Heaters

3M Self Regulating Heating Cables

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

Installation Instructions

Heating Cable. Description

Heating Cable. Construction

Heating Cable. Description

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

Heating Cable. Cut to Length in Field. Description

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

FREEZSTOP MICRO SYSTEM

Heating Cable. Ordering Information SRL-C SRL-CR, CT SRP-C, SRP-CT CWM-C CWM-CT SRL-MC SRL-MCR, MCT SRM/E-C SRM/E-CT SRL-C SRL-CR, CT SRP-C, SRP-CT

DEF-Trac. Design and Installation Guide. August 2015

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

accqpulse Velocity Profiler Sensor Installation Guide

Self-Regulating Freeze Protection Heating Cable

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

P & P Technology Ltd

Heating Cables. For Industry Tracing

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

Self-Regulating Cables

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Pipe Freeze Protection Design/Install Guide

SELF-REGULATING CABLES

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

C Power Connection Kit

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

DEF-Trac. Design and Installation Guide. August 2014

Band Heaters Maxiband Heaters Maxiband The Most Sought After Band Heater

Kompensator External Low Voltage Heating Cable System

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

120/240 Volts 3 Watt Floor Heating Cable System

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

EasyStart Installation Instructions for Dometic Family RV A/Cs

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

Plugs and Receptacles: Hazardous Location

Electrical. Hardware & Fastening Solutions. Battery Supplies. J-Case Fuses - Regular... Page 162

Built-In Temperature Controller

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Hazardous Factory Sealed Control Devices

Rittal CM Compact System Enclosures

Certified to Protect. Built to Endure.

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Warm Tiles Troubleshooting. Al & Jed

EQUIPMENT HEATING SYSTEMS & SOLUTIONS

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

N. 15th Street, Middlesboro, KY CRUSHED CAR HAULER INSTALLATION INSTRUCTIONS

Installation Instructions Mineral Insulated (M.I.)

FLEXTRACE. Power (W/m) Dimensions

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

Seat Comfort Systems Ventilation/Heater Installation Instructions

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Transcription:

RT FlexiPanel TM Tank and Vessel ing Panel Application... Metallic Tank and Vessel ing The RT FlexiPanel is a self-contained, high performance flexible heating panel designed specifically for use on metallic tanks and vessels. Designed to provide heat outputs at 3100 Watts per square metre or less, the RT FlexiPanel distributes heat evenly over the entire panel surface. The low profile flexible design of the panel permits rapid, trouble-free installation using the mounting kit available from Thermon. To ensure multiple flow paths for electrical current to pass, the RT FlexiPanel utilises a parallel circuit design based on a stamped high temperature alloy heating element. This design eliminates the burnout potential common with series wire-based designs. The rugged construction of the RT FlexiPanel includes a tough metal jacket that provides mechanical protection during handling and installation. The panel s heating element is further protected from vibration and moisture by sandwiching it in a heat-laminated layer of silicone rubber that provides cushion and a watertight seal. RT FlexiPanels are approved for use in ordinary (nonclassified) and hazardous (classified) areas per U.S. standards. Ratings 1... Nominal outputs... 500, 1000 and 2000 W Supply voltages... 220-240 Vac Maximum maintenance temperature... 121 C Maximum continuous exposure temperature Power-off... 232 C Thermal cutout switch setting 2... 160 C Minimum installation temperature... -51 C Basic Accessories... Mounting Kit: All FlexiPanels require a mounting kit for installing the panel to a tank or vessel wall. Refer to the back of this specification sheet for details. 1 2 3 4 5 Construction... 1 High Temperature Lead Wires (1.3 mm 2 ) 2 Overtemperature Safety Cutout Switch 3 Protective Metal Jacket 4 Parallel Circuit High Temperature Alloy ing Element 5 -Laminated, High Temperature Silicone Rubber Insulation Certification/Approval... Factory Mutual Research Hazardous (Classified) Locations Notes... 1. Custom sizes, Watt densities and operating voltages are available; contact Thermon for design assistance. 2. Thermal cutout switch settings are available from 43 C to 160 C; contact Thermon for additional THERMON... The Tracing Specialists www.thermon.com European Headquarters Boezemweg 25 2641 KG Pijnacker PO Box 205 2640 AE Pijnacker The Netherlands Phone: +31 (0) 15-36 15 370 Facsimile: +31 (0) 15-36 15 379 Corporate Headquarters 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 U.S.A. Phone: +1 512-396-5801 Facsimile: +1 512-396-3627

RT FlexiPanel TM Tank and Vessel ing Panel Available RT Panels 1... Product Type Service Voltage Output W Current Draw A Lead Wires and Terminations... Density W/m 2 Panel Dimensions mm RT-522 240 500 2.1 2635 305 x 610 RT-1022 240 1000 4.2 3100 305 x 1067 RT-2022 240 2000 8.3 3100 305 x 2134 Each FlexiPanel is equipped with 1.83 m long high temperature silicone rubber insulated wires with a liquid-tight conduit fitting. Other three-wire cords are available; contact Thermon. Circuit Breaker Sizing and Type... Multiple panels can be energised from the same circuit breaker based on operating voltage and current draw. The current draw, breaker sizing and earth-fault protection should be based on applicable local codes. For information on design and performance on other voltages, contact Thermon. Earth-fault protection of equipment should be provided for each branch circuit supplying electric heating equipment. 1. RT FlexiPanels can be custom-fabricated to specific voltages, heat outputs and physical dimensions; contact Thermon. Accessories... RTM Mounting Kit: Provides the materials and tools necessary to install RT FlexiPanels. Kit includes adhesive with applicator, spreader, roller and attachment tape. One kit will facilitate the installation of up to 7500 cm 2 of heating panel. Control Thermostats: Thermon offers a complete line of mechanical thermostats and electronic control and monitoring modules designed and approved specifically for electric heat tracing applications. Power Distribution: For heating applications involving multiple tank or vessel heating circuits or where FlexiPanels will be used in conjunction with electric pipe heat tracing, Thermon can provide complete power distribution and control panels. These panels can be custom-designed to meet the specific requirements of an application, including enclosure type and control and monitoring capabilities. Contact Thermon for complete Form TEP0030U-1200 Thermon Manufacturing Co. Printed in U.S.A. Information subject to change.

RTF FlexiPanel TM Tank and Vessel ing Panel Application... Nonmetallic Tank and Vessel ing The RTF FlexiPanel is a self-contained, high performance flexible heating panel designed specifically for use on fibreglass and plastic tanks or vessels and for metallic tanks or vessels containing high viscosity or temperature-sensitive fluids. Designed to provide heat outputs at 1085 Watts per square metre or less, the RTF FlexiPanel distributes heat evenly over the entire panel surface to maintain stable temperatures. The low profile flexible design of the panel permits rapid, trouble-free installation using the mounting kit available from Thermon. To ensure multiple flow paths for electrical current to pass, the RTF FlexiPanel utilises a parallel circuit design based on a stamped high temperature alloy heating element. This design eliminates the burnout potential common with series wire-based designs. The rugged construction of the RTF FlexiPanel includes a tough metal jacket that provides mechanical protection during handling and installation. The panel s heating element is further protected from vibration and moisture by sandwiching it in a heat-laminated layer of silicone rubber that provides cushion and a watertight seal. RTF FlexiPanels are approved for use in ordinary (nonclassified) and hazardous (classified) areas per U.S. standards. Ratings 1... Nominal output... 500 W Supply voltages... 220-240 Vac Maximum maintenance temperature... 65 C Maximum continuous exposure temperature Power-off... 232 C Thermal cutout switch setting 2... 99 C Minimum installation temperature... -51 C Basic Accessories... 1 2 3 4 5 Construction... 1 High Temperature Lead Wires (1.3 mm 2 ) 2 Overtemperature Safety Cutout Switch 3 Protective Metal Jacket 4 Parallel Circuit High Temperature Alloy ing Element 5 -Laminated, High Temperature Silicone Rubber Insulation Certification/Approval... Factory Mutual Research Hazardous (Classified) Locations Mounting Kit: All FlexiPanels require a mounting kit for installing the panel to a tank or vessel wall. Refer to the back of this specification sheet for details. Notes... 1. Custom sizes, Watt densities and operating voltages are available; contact Thermon for design assistance. 2. Thermal cutout switch settings are also available at 60 C for low density polyethylene tanks and 82 C for high density polyethylene tanks. Contact Thermon for additional THERMON... The Tracing Specialists www.thermon.com European Headquarters Boezemweg 25 2641 KG Pijnacker PO Box 205 2640 AE Pijnacker The Netherlands Phone: +31 (0) 15-36 15 370 Facsimile: +31 (0) 15-36 15 379 Corporate Headquarters 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 U.S.A. Phone: +1 512-396-5801 Facsimile: +1 512-396-3627

RTF FlexiPanel TM Tank and Vessel ing Panel Available RTF Panels 1... Product Type Lead Wires and Terminations... Each FlexiPanel is equipped with 1.83 m long high temperature silicone rubber insulated wires with a liquid-tight conduit fitting. Other three-wire cords are available; contact Thermon. Accessories... Service Voltage Output W Current Draw A Density W/m 2 Panel Dimensions mm RTF-2260 240 500 2.1 1084 305 x 1524 RTF-2284 240 500 2.1 775 305 x 2134 Circuit Breaker Sizing and Type... Multiple panels can be energised from the same circuit breaker based on operating voltage and current draw. The current draw, breaker sizing and earth-fault protection should be based on applicable local codes. For information on design and performance on other voltages, contact Thermon. Earth-fault protection of equipment should be provided for each branch circuit supplying electric heating equipment. 1. RTF FlexiPanels can be custom-fabricated to specific voltages, heat outputs and physical dimensions; contact Thermon. RTM Mounting Kit: Provides the materials and tools necessary to install RTF FlexiPanels. Kit includes adhesive with applicator, spreader, roller and attachment tape. One kit will facilitate the installation of up to 7500 cm 2 of heating panel. Control Thermostats: Thermon offers a complete line of mechanical thermostats and electronic control and monitoring modules designed and approved specifically for electric heat tracing applications. Power Distribution: For heating applications involving multiple tank or vessel heating circuits or where FlexiPanels will be used in conjunction with electric pipe heat tracing, Thermon can provide complete power distribution and control panels. These panels can be custom-designed to meet the specific requirements of an application, including enclosure type and control and monitoring capabilities. Contact Thermon for complete Form TEP0031U-1200 Thermon Manufacturing Co. Printed in U.S.A. Information subject to change.

HT Module Hopper ing Module Application... Hopper and Chute ing The HT hopper heating module is a rugged, self-contained high performance heater designed for reliable operation on surfaces prone to vibration. Designed to provide heat outputs up to 4650 Watts per square metre depending on the application, the HT module distributes heat evenly over the entire panel surface. To ensure optimal performance, each system is engineered by Thermon based on the heating requirements of the application. A parallel circuit design, based on a stamped high temperature INCONEL heating element, provides the HT heating module with multiple flow paths for electrical current to pass. This design eliminates the burnout potential common with series wire-based designs. Protection of the heating element from vibration is achieved with a cushion layer of insulation that also directs the flow of heat from the module to the surface being heated. The rugged construction of the module includes a tough 20-gauge aluminized steel shell that provides mechanical protection during handling, installation and operation. Weld splatter, rust or oil will not affect the integrity or performance of the heater. The low profile design of the panel permits rapid, trouble-free installation. HT hopper heating modules are approved for use in ordinary (nonclassified) and hazardous (classified) areas per U.S. standards. Ratings 1... Maximum Watt density... 4650 W/m 2 Supply voltages... 120-600 Vac Maximum maintenance temperature... 427 C Maximum continuous exposure temperature Power-off... 538 C Minimum installation temperature... -40 C Basic Accessories... Mounting Kit: All HT heating modules include a mounting kit comprised of a reinforced channel, spacers, attachment nuts and washers. Mounting studs, installation templates and other accessories are also available. Refer to the back of this specification sheet for details. 1 2 3 4 5 Construction... 1 Fluoropolymer Insulated High Temperature 1.3 mm 2 Lead Wires (with stress relief at connection) 2 Parallel Circuit High Temperature Alloy ing Element 3 Temperature-Rated Insulation (directs energy towards surface to be heated) 4 20-Gauge Aluminized Steel Protective Enclosure 5 20-Gauge Aluminized Steel Protective Cover with Reinforced Attachment Channel Certification/Approval... Factory Mutual Research Hazardous (Classified) Locations 1. Watt density and operating voltage are based on application-specific availability and requirements. THERMON... The Tracing Specialists www.thermon.com European Headquarters Boezemweg 25 2641 KG Pijnacker PO Box 205 2640 AE Pijnacker The Netherlands Phone: +31 (0) 15-36 15 370 Facsimile: +31 (0) 15-36 15 379 Corporate Headquarters 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 U.S.A. Phone: +1 512-396-5801 Facsimile: +1 512-396-3627

HT Module Hopper ing Module Available HT Module Sizes... Product Type 1 Base Module Module Dimensions cm Stud Spacing cm 612 15 x 40 36 624 15 x 70 65 636 15 x 99 94 648 15 x 129 123 212 30 x 40 36 224 30 x 70 65 236 30 x 99 94 248 30 x 129 123 Circuit Breaker Sizing and Type... Multiple modules can be energised from the same circuit breaker based on operating voltage and current draw. The current draw, breaker sizing and earth-fault protection should be based on applicable local codes. 1. Product types shown are partial descriptions. Delivered product will have prefix and suffix designations to identify complete design parameters; contact Thermon for design assistance. Accessories... Mounting Studs: Weld studs with ceramic ferrules (2 per heater). Lead Wire Routing Guide: Provides protective routing for heater wiring between heating module and junction box. Junction Box: Enclosure with 600 V terminal strips (optional mounting bracket available). High Temperature Splice Kit: Temperature rated to 538 C, kit permits splicing of heating module lead wires (12 splices per kit). Control Thermostats: Thermon offers a complete line of mechanical thermostats and electronic control and monitoring modules designed and approved specifically for electric heat tracing applications. Power Distribution: For heating applications involving multiple hopper heating circuits or where hopper modules will be used in conjunction with electric pipe heat tracing, Thermon can provide complete power distribution and control panels. These panels can be custom-designed to meet the specific requirements of an application, including enclosure type and control and monitoring capabilities. Contact Thermon for complete Form TEP0046U-1200 Thermon Manufacturing Co. Printed in U.S.A. Information subject to change.