Turbine Meters & Accessories

Similar documents
LIQUID CONTROLS A Unit of IDEX Corporation

Liquid Controls. Turbine Meters for Custody Transfer Flow Measurement of Petroleum Products. Loading Terminal, Offshore, and Pipeline Applications

BARTON 7400 Precision Gas Turbine Flow Meters

G2 Industrial Grade Meters

Liquid Turbine Flowmeter

High Performance Turbine Technology

TBM Series 3-Way Ball Valve

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies

Industrial Meter Catalog

INDUSTRIAL METER CATALOG version seven

A1 Commercial Grade Meters

Liquid Turbine Flowmeters

Vortex Eggs Delta Flowmeter

Electromagnetic Flowmeters. Product Overview.

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC.

FT Series. Turbine Flowmeters. Description. Features. Applications. Operation. FT Series Turbine Flowmeters

Liquid Turbine Flowmeters

EZ-IN Series Turbine Flowmeter

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 Commercial Grade Meters

EQUIVALENT BASIC CIRCUIT

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

LCMass Series Mass Flow Sensor

Liquid Turbine Flow Meters

KDM ARMORED FLOW METER & SWITCH

MF SERIES. Mini-Flowmeters for Low Flow Applications USER S MANUAL HP-210. January 2013

SSI Technologies MediaSensor

Liquid Turbine Flowmeters

EZ-View. Flow Meters ISO CERTIFIED 9001

VORTEX IN-LINE FLOW METERS

Hoffer Engineering Guide for Liquids

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Flow Measurement Technology Training

G2 SERIES INDUSTRIAL GRADE METERS

ISTEC MAGNETIC METERS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Model 1100 Turbine Flow Meter

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

BARTON 7000 Series Liquid Turbine Meters

INSTALLATION & OPERATION MANUAL

TYPE MP OSCILLATING PISTON FLOWMETER

MODEL 1100 TURBINE FLOW METER

Solenoid Operated Block Valves A2800 Series

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Hot Tap Insertion Vortex

Vortex In Line Flow Meter

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

QUALITY INDUSTRIAL FLOWMETERS

FR1118- P10. User s Manual

Electronic lube meter

MSD Start/Retard Control PN 8982

F-2500 SERIES VORTEX METER

SERIES 2100 Resilient Seated Butterfly Valves

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

MF SERIES Mini-Flowmeters for Low Flow Applications

HIGH VOLTAGE DIGITAL AMMETER

Vortex In Line Flow Meter

mass flowmeter for compressed air

HR-20P Pneumatically Controlled Pressure Regulator

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

RCM. Direct Reading Flowmeter. for Liquids or Gases

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

PRECISION METERS & ACCESSORIES

Model FVP General Specification. Flanged Vortex Plate. Product Features

Traffic Logix SafePace 450 Radar Speed Sign

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

1 2-Inch Station Outlet Valves

F-1500 SERIES INSERTION TURBINE FLOW METER

Armstrong In-Line and Insertion Vortex Flow Meters

Flow Measurement & Control Solutions

flow measurement solutions RIM10 series rotor insertion flowmeters

Turbine flowmeters Series TM

SERIES 2200 Replaceable Seat Butterfly Valves

WEB CONTROL PRODUCTS

Air Chain Hoist. Follow all instructions and warnings for. Capacities. 250 lbs (113 kg) 300 lbs (136 kg) 500 lbs (226 kg) 600 lbs (272 kg)

Glass Tube Full-View Flowmeters

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

F-2600 SERIES INLINE VORTEX FLOW METER

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

MFM220 & MFM220DC Plastic-Bodied Magmeter

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

INDUSTRIAL DYNAMICS CO

Rotary Flow Meter SERVICE MANUAL*

7000 Series Liquid Turbine Meters

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Transcription:

PRODUCT OVERVIEW Aerospace Agriculture Chemical Cryogenic Food Gases Military Petrochemical Petroleum Pharmaceutical Pulp & Paper Utilities Turbine Meters & Accessories LIQUID CONTROLS A Unit of IDEX Corporation

Features Absolute Accountability In Turbine Meter Technology LC Turbine Meters offer unsurpassed accuracy, efficiency and service life, and meet most liquid or gas flow measurement applications. LC Turbine Meters available in stainless steel or corrosive series with a hydraulically balanced turbine rotor Materials of Construction Include: Standard 304 Stainless Steel Optional 316/316L Stainless Steel, Monel, Brass, Aluminum, Alloy 20, Plastic Note: Corrosive series materials available. Consult factory. (no thrust bearing) and rugged, compact construction for the most accurate and reliable measurement available. Flow ranges are from 0.25 to 12,000 GPM and temperatures from -450 F (-268 C) to +1,000 F (+538 C). A wide variety of electronic instrumentation and components complete your flow needs. Features include: High pressure applications. Custom and standard designs. Wide choice of bearings, including carbide Interfaces with manual, semiautomated or completely automated systems. Materials compatible with application. Custom design and system engineering service. Manufactured in USA. Pickup Coil Standard Temperature from -450 F (-268 C) to +450 F (+232 C) [Optional to +1000 F (+538 C)] Amplifier recommended to minimize EMI Standard with Flow Straightener both upstream and downstream for improved accuracy Bearing Choices Include: Standard: Stainless Steel or Cryo Ball Bearings Options: Fluorosint Carbide Sleeve Bearings Lightweight, Hydraulically Balanced Rotor. No Thrust Bearing 17-4 PH Stainless Steel Rotor Construction(Standart) Note: For other materials, Consult Factory Standard End Fittings Include: Male NPT Standard 37 Flare Standard ANSI Flange Standard Sanitary Optional (For Others Including High Pressure, See Description Chart) 304 Stainless Steel Support Shaft & Cones (Standard) Does Not Turn Typical Application for Liquids & Gases Acetylene (Consult Factory) Air Anhydrous Ammonia Argon Brine CNG Cryogenic CO 2 Freon Gasoline Helium Hydrogen LNG LPG Mercaptans Methane Nitrogen Nitrous Oxide Oxygen Steam (Consult Factory) Water, DI Water, Fresh Water, Salt 2

Explosion Proof Rate And/Or Totalizer Indicators Model LC200N - RATE A battery powered industrial Remote Rate Indicator device that provides Flow Rate in any engineering unit. Rate is displayed via an 8-digit Liquid Crystal Display. Selection of the Reset Function is accomplished externally by magnetic field to maintain unit integrity while permitting complete operational control in hazardous environments. Auxiliary digital factored pulse output is standard. Model LC150N-TOTAL A battery powered Industrial Remote Totalizer that provides Flow Totalization in any engineering unit. Total is displayed via an 8- digit Liquid Crystal Display. Reset of the Totalizer is accomplished externally by a magnetic field to retain unit integrity while permitting complete operational control in hazardous environments. Auxiliary digital factored pulse output is standard. Model LC275N-RATE/TOTAL A battery powered device providing flow totalization and rate in any engineering unit. Total and Rate are displayed via two 8-digit Liquid Crystal Displays. The totalizer Reset Function is accomplished externally by a magnetic field to retain unit integrity while permitting complete operational control in hazardous environments. In addition, the LC275N provides one analog interface output. The 4-20mA loop control extracts no power from the loop. DC powered by internal AA Lithium battery FM approved and CSA certified, Class I, Group B, C & D and Class II, Group E, F & G, Nema 4 Direct mounted to Flow Meter Fully programmable, field calibration via BCD switches Model LC300N-RATE/TOTAL An industrial counter providing rate and flow totalization in any engineering unit. Unit features 10-point linearization with 1 pulse and 1 analog output. Can be battery, loop or VDC powered. Model LC200N - Rate Model LC150N - Totalizer Model LC275N - Rate/Totals Indicator Model LC300N - Rate/Totals Indicator Explosion Proof Transmitters & Amplifiers Model LC711-3 A meter-mounted 3-wire Analog Transmitter designed to linearly convert a frequency input to an equivalent voltage output whose level is switch selectable @ 0-5V/0-10V. Model LC712-2 A meter mounted true 2-wire loop powered Analog Transmitter designed to linearly convert a frequency input to an equivalent 4-20mA current output. Model LC714 A meter-mounted device that amplifies and conditions low-amplitude signals such as those developed by a magnetic pickup coil. The amplitude of the squarewave output equals the input supply voltage. FM approved and CSA certified, Class I, Group B, C & D and Class II, Group E, F & G, Nema 4 Direct mounted to Flow Meter 7

Gross Pressure Drop Caracteristics Data Based on H 2 O for Liquids/Air for Gases Gross Pressure Drop PSID Volumetric Flow Rate GPM/ACFM = Min. Linear Flow For estimating pressure drop on liquids other than water at room temperature: P = Visc* (Cpse) 1/4 x Sp. Gr. 3/4 x PH 2 O (Corrected) (from Curve) * Absolute Visc (C'poise) = Kinematic Visc (C'stokes) x Sp. Gr. For estimating pressure drop on gases at densities other than 1Lb/Ft 3 : P = (Density in lbs./ft 3 ) x P on Chart MODEL DESCRIPTION CHART LC 1/4 -MB-NL-A-4-HTX Bearing Type MB=Metal Ball CB=Cryo Ball CS=Carbide Sleeve FS=Fluorosint Sleeve Rotor Type NL =304 Nickel Liquid PHL =17-4PH Liquid PH7 =17-4PH-SS7 Degree PH12=17-4PH-SS12 Degree PH15=17-4PH-SS15 Degree Endfitting Type A =NPT FA =FNPT B =AN Flare C =150CS D =150SS E =300CS F =300SS J =600CS K =600SS G =Sanitary H =High Pressure I =Tube Fitting W = Water Material 4 =304SS 4L =304LSS 6 =316SS 6L =316LSS Coil Options Blank = Standard HT = Hi-Temp RF = Mod. Carr. Boss Options X = Boss Blank = No Boss 6

Specifications for Liquids Linearity: ±.5% Standard. Linearity: ±.25% over specified flow range. (Consult Factory) Repeatability ±.05% Standard. Repeatability: ±.02% over specified range.(consult Factory) Temperature: -450 F (-268 C) to +1000 F (+538 C) Materials: Standard LC Turbine Flowmeters are constructed of 300 Series stainless steel. A variety of other materials are available to satisfy most applications including CPVC for corrosive applications. Electrical Output: A minimum of 30 mv peak to peak at the bottom of the nominal rated flow range. Pressure Drop: 4 psi at nominal rated flow range. End Fittings: Include AN Series 37 deg. Flare Tube (MS-33656), NPT, ANSI Flanged and Sanitary End Fittings Available. Other end fittings available on request. Operating Pressure: Accommodates unlimited pressure depending on end fittings. Calibration: LC Turbine Flowmeters furnished with standard fluid calibration and meter factor. Special calibrations available. Flow Ranges: From 0.25 to 12,000 GPM (45,420 LPM). Specifications for Gases Linearity: ± 1.0% over full range Repeatability: ±.25% Temperature Range -450 F (-268 C) to +750 F (+399 C) Liquid Sizing Chart Gas Sizing Chart NOMINAL METER SIZE MINIMUM REPEATABLE 1/4 0.25 0.5 2.5 15,000 3/8 0.35 0.75 5 3160 1/2 0.6 1.25 9.5 3160 5/8 0.9 1.75 16 1875 3/4 1.75 2.5 29 1035 1 3 4 60 500 1-1/4 4 6 93 322 1-1/2 6 8 130 230 2 12 15 225 133 2-1/2 15 25 400 75 3 30 40 650 46 4 50 75 1250 21 5 100 140 2000 9.0 6 125 200 2900 5.5 8 280 330 5200 2.4 10 550 650 8000 5.95* 12 800 900 12000 5.95* *Rim Type Rotor Approximate value NOMINAL FLOW RANGE U.S. Gallons Per Minute MINIMUM LINEAR NOMINAL MAXIMUM METER K FACTOR PULSES/U.S. GAL. METER SIZE FLOW RANGE (ACFM) (MAGNETIC PICKUP) MINIMUM LINEAR MAXIMUM LINEAR 1/4 0.35 3.5 3/8 0.75 5.0 1/2 1 10.0 5/8 2.0 20.0 3/4 2.5 28.0 1 4.0 60 1 1/4 6.0 100 1 1/2 8 130 2 15 250 2 1/2 25 450 3 40 650 4 75 1200 5 150 1800 6 250 2900 8 330 5000 10 650 7500 12 900 12000 3

End Flanged (ANSI B16.5) SIZES (1/2" - 12") Meter size is based on nominal inside diameter of pipe. For installation dimensions for sizes larger than 6", consult factory. For proper matching always specify inside diameter of mating pipe. Special flanges can usually be provided to specification. For hazardous areas, pick up coils with explosion proof housing can be provided. All Flowmeters 1/2" and smaller will be provided with 1/2" End Connections unless otherwise specified. IMPORTANT: Dimensions shown are NOT for construction use. Consult factory when certified Engineering Prints are required. Installation Dimensions (INCHES) LINE 150#ANSI 300#ANSI 400#ANSI SIZE A B A B A B 1/2 5 3 1/2 5 3 3/4 5 3 3/4 5/8 5 1/2 3 1/2 5 1/2 3 3/4 5 1/2 3 3/4 3/4 5 1/2 3 7/8 5 1/2 4 5/8 5 1/2 4 5/8 1 5 1/2 4 1/4 5 1/2 4 7/8 5 1/2 4 7/8 1 1/4 6 4 5/8 6 5 1/4 6 5 1/4 1 1/2 6 5 6 6 1/8 6 6 1/8 2 6 1/2 6 6 1/2 6 1/2 6 1/2 6 1/2 2 1/2 7 7 7 7 1/2 7 7 1/2 3 10 7 1/2 10 8 1/4 10 8 1/4 3 1/2 12 8 1/2 12 9 12 9 4 12 9 12 10 12 10 5 14 10 14 11 14 11 6 14 11 14 12 1/2 14 12 1/2 600#ANSI 900#ANSI 1500#ANSI 2500#ANSI A B A B A B A B 5 3 3/4 7 4 3/4 7 4 3/4 7 5 1/4 5 1/2 3 3/4 7 4 3/4 7 4 3/4 7 5 1/4 5 1/2 4 5/8 7 5 1/8 7 5 1/8 7 5 1/2 5 1/2 4 7/8 8 5 7/8 8 5 7/8 8 6 1/4 6 5 1/4 8 6 1/4 8 6 1/4 8 7 1/4 6 6 1/8 9 7 9 7 9 8 6 1/2 6 1/2 9 7 9 7 9 8 7 7 1/2 10 9 5/8 10 9 5/8 10 10 1/2 10 8 1/4 10 9 1/2 10 10 1/2 11 12 12 9 - - - - - - 12 10 3/4 12 11 1/2 12 12 1/4 12 14 14 13 14 13 3/4 14 14 3/4 14 19 14 14 14 15 14 15 1/2 16 19 Typical Arrangement of Flowmeter Readouts 4

MS Flared Tube SIZES (1/4" - 2") LINE DIMENSIONS (inches) END CONNECTIONS APROX. WT SIZE A B C FLARED TUBE LBS/Kg 1/4-1/2 1 1/8 2 5/8 3 3/4-16UNF-3A.38/.173 5/8 1 1/8 2 3/4 3 7/8-14UNF-3A.75/.341 3/4 1 5/8 3 1/4 3 1/2 1 1/16-12UN-3A.75/.341 1 1 5/8 3 1/2 4 1 5/16-12UN-3A 1.3/.627 1 1/4 2 3 7/8 4 3/8 1 5/8-12UN-3A 1.75/.795 1 1/2 2 1/8 4 3/8 4 5/8 1 7/8-12UN-3A 2.31/1.05 2 2 3/4 4 3/4 5 3/8 2 1/2-12UN-3A 3.0/1.36 IMPORTANT: Dimensions shown are NOT for construction use. Consult factory when certified Engineering Prints are required. Male NPT SIZES (1/4" - 3" ) LINE DIMENSIONS (inches) END CONNECTIONS APPROX. WT SIZE A B C MNPT LBS/Kg 1/4-1/2 1 1/8 3 3 1/2.38/.173 5/8 1 1/8 3 3 1/2.75/.341 3/4 1 5/8 3 1/4 3 1/2 3/4.75/.341 1 1 5/8 3 1/2 4 1 1.3/.627 1 1/4 2 3 7/8 4 3/8 1 1/4 1.75/.795 1 1/2 2 1/8 4 3/8 4 5/8 1 1/2 2.31/1.05 2 2 3/4 4 3/4 5 3/8 2 3.0/1.36 2 1/2 3 1/4 6 1/16 5 3/8 2 1/2 5.5/2.50 3 3 1/2 10 5 5/8 3 10/4.54 IMPORTANT: Dimensions shown are NOT for construction use. Consult factory when certified Engineering Prints are required. Typical Flowmeter System Installation 5

SOLD AND SERVICED BY A NETWORK OF HIGHLY TRAINED FULL SERVICE DISTRIBUTORS LIQUID CONTROLS A Unit of IDEX Corporation Backed By Our Worldwide Reputation For Quality, Accuracy and Advanced Design. WARRANTY: The seller s products are warranted against defects in material or workmanship for a period of (1) year from date of LC invoice. Seller s obligations, as set forth below, shall apply only to failure(s) to meet the foregoing obligations provided that Seller is given written notice within thirty (30) days of any occurrence from which a claim of defect arises. In the event that a factory inspection by Seller s or it s designee(s) supports the validity of a claim at the discretion of Seller, repair, replacement, or refund shall be the sole remedy for defect and shall be made, free of charge, Ex-works factory. In no event shall Seller be liable for any special consequential, incidental, indirect or exemplary damages arising out of warranty, contract tort (including negligence) or otherwise, including but not limited to, loss of profit or revenue, loss of use of the product or any and all associated products and/or equipment, cost of substitute goods or services, downtime costs or claims of or by Purchaser s clients or customers. In any event, the total liability of Seller for any and all claims arising out of or resulting from the performance, non-performance or use of the product shall not exceed the purchase price of the individual product giving rise to the claim. All other guaranties, warranties, conditions and representations LIQUID CONTROLS A Unit of IDEX Corporation 105 Albrecht Drive Lake Bluff, IL 60044-2242 (847) 295-1050 FAX: (847) 295-1057 Website: www.lcmeter.com either express or implied, whether arising under any statute, common law, commercial usage or otherwise are excluded. Electronic products require installation, start-up and servicing by local factory-trained service representatives. In the absence of installation, start-up and servicing of electronic products by Seller trained service representatives, this warranty is null and void. Seller s obligations as set forth above shall not apply to any product, or any component or part thereof, which is not properly installed, used, maintained or repaired, or which is modified other than pursuant to Seller s instructions or approval. Backed By Our Worldwide Reputation For Quality, Accuracy and Advanced Design. Distributed By: Printed with vegetable inks on recycled paper. Please Recycle! 2001 LIQUID CONTROLS Printed in U.S.A. (03/01) Bulletin #500023D $1