Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

LEDVANCE SUPERSTAR LED Downlight Gen 2

Installation Instructions

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Light Source User Guide

CLA IPART APPROVED PRODUCTS 2017

PIL0478 ISSUE 01/ 07/16

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

Idaho Profile System - Trimless

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Interior Utility Lights

DALI 650mA LED Driver

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

LED Driver + Dimmer 5YEAR. 40W, 60W or 100W Constant Voltage LED Driver with Integrated Dimmer for Single Gang Box Mount FEATURES & BENEFITS

15 DOWNLIGHTS - dedicated LED. Downlights DEDICATED LED DOWNLIGHTS DOWNLIGHT FITTINGS

Beams Spot (15 to 21.5 ) Narrow Flood (24 to 28.5 ) Flood (38 to 39 ) Wide (60 to 65 ) Reflectors Aluminum reflectors

650mA Phase Dimmable LED Driver

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

Measurements are expressed in millimeters.

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

1000mA - 650mA Phase Dimmable LED Driver

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications. 2 installation options Surface mount

Light Source User Guide

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ECO EXT (DIMMABLE)


Recessed Downlights. Zas

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications 90+ CRI. 2 installation options Surface mount

DOWNLIGHTS DEDICATED LED DOWNLIGHTS 017. DEDICATED LED DOWNLIGHTS 035. DOWNLIGHT FITTINGS

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Linear Line Voltage LED Engine

Linear Line Voltage LED Engine

CFP-LED Contractor Select Flat Panel. Installation Instructions

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Vision Profile System - Surface

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

TRUET5 EXT (DIMMABLE)

High Bay Luminaire Series

Quad. Indoor recessed. ø1.69" 3.11" 2.36" 2.36" IP40 IP44. max 6W - max 500mA. max 6W - max 500mA. QD1232 N Black. B White.

2X4 LED RECESSED TROFFER

User Guide for Logo Projector

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

LED Light Bar - LEDKIT 2 & 3

P/N Wheeler. user manual

Light is reliable LED Lamps and Luminaires

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

P90L-ISO6MB & ISO10MB

Utah Profile System - Recessed

Ardito LED - A2RSF SPECIFICATION SHEET. 2-1/2" Series. Ultra-Thin Profile Round Regressed Shower Trim SPECIFICATIONS

MOONRING 1.5 MOONRING 3

TJT120023ACxxxB TJT120023ACxxxC

Fire Rated Downlights Product Catalogue

EMERY SKY SUSPENDED LED LUMINAIRE

LEDVANCE Downlight L DALI

PRIMUS I PRIMUS II. Primus - Downlight. Primus - Wall Wash SPEC SPEC. Trim Options

MaxLite LED UTILITY WRAP FIXTURES

SPECFIT 8" Retrofit Downlight AD8 DIM010 UNV ADR8. Project: Part#: Type: Ex: AD8-LES-9040-DIM010-UNV-MD-ADR8-CC

LED Recessed Troffer Retrofit Kit

SPECFIT 6" Retrofit Downlight AD6 DIM010 UNV ADR6. Project: Part#: Type: Ex: AD6-LES-9040-DIM010-UNV-MD-ADR6-CC

Constant Voltage TRIAC Dimmable Driver---120W Series. Features

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

DL-FLEX (-UP, -UP-HO, -UP-ULTRA)

SL2282 LED Clipper Ceiling Light 180MM 11W SURFACE MOUNTED LED DOWNLIGHTS

Installation Instructions: Eco Linear High Bay

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

LED Pinspot 2. Snapshot. User Manual

C3R 0-10V Tunable White & Warm Dim REMOTE 24V POWER SYSTEM 0-10V CONTROL MODULES & DIMMER

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED Pinspot 2. Snapshot. User Manual

2X2 LED RECESSED TROFFER MLRT22D SERIES

E-CORE LED TUBE GX16T-5 DATA SHEET 1 /5

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

Maxline Profile System - Surface

Transcription:

LEDLUX EXPRESS MAXI DIMMABLE LED DOWNLIGHT SKU# 170577, 170578 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation and use. Please keep instructions for future reference. Warranty This light fitting is covered by a 5 year warranty. The warranty is from date of purchase, not the date of installation. Please retain proof of purchase. The use of non-tested dimmers may damage your LED light fitting and will void your warranty. Warranty will be void if there is any damage due to improper usage or modification to the fitting. Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. Installation Requirements Before installation, check the installation location in the ceiling has access to a socket outlet which is connected to a wall light switch and dimmer. If it does not, please contact a licensed electrician to arrange installation of the socket outlet, wall light switch and dimmer before continuing. All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician. Select a suitable location for installation: This product is suitable for indoor use only. The mounting point must support 2 times the weight of the fitting. Ensure the fitting is not installed in direct line of an air vent/system. When installing a fitting in an area prone to moisture, ensure that the area is well ventilated and an appropriately rated exhaust fan is used if required. Damage or corrosion caused by moisture is not a product fault, and as such is not covered under warranty. This fitting is dimmable and has been tested with Lucci LEDlux SKU# 290998 dimmer, Clipsal 32E450TM, Clipsal 31E2RUDM and Clipsal 32E450UDM dimmers only at the time of publication. The use of a LED dimmer such as the Lucci LEDlux SKU# 290998 dimmer is highly recommended. NOTE: For the best dimming range, use with the Lucci LEDlux SKU# 290998 dimmer and adjust the variable resistor at minimum and maximum dimming positions on the dimmer during the installation. NOTE: The use of non-tested dimmers may damage your LED light fitting and will void the warranty. NOTE: Dimming may cause buzzing sounds or a slight flicker. There may be slight delays with the LED light start up or slight uneven light performance when more than one LED light fitting is linked together, switched ON or dimmed. This is not a product fault and as such is not covered under warranty. NOTE: Some dimmers have a minimum load of 20W. Ensure the dimmer position is on the maximum setting before turning on the LED light and adjust the dimmer down to your desired light level. NOTE: Testing cannot account for installation variables such as variation in mains supply voltage, cable capacitance, electrical noise, transients, surges and ripple control signals (commonly found in NSW & QLD). NOTE: The information provided is correct to the best of Beacon Lighting s knowledge at the date of publication. This fitting has an insulating ceiling type IC rating. Building insulation material can safely be exposed continuously to temperatures up to 90 C and may abut and cover the luminaire. (Please refer to the Clearance Information section and the IC Rating section in this instruction manual for further details.) If loose fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g. leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance Information section in this instruction manual. 1 P a g e v 1.1 P u b l i s h e d on 0 3. 2 0 1 6

The LED driver must be placed at least 50mm away from the LED downlight module to allow for cooling. The LED driver must be placed above the insulation, DO NOT cover the driver with insulation to allow for cooling. (Please refer to the Clearance Information section in this instruction manual for further details.) The LED downlight module is only suitable for use with Lucci LED Driver model#: QM-P12X2W-FR. The fitting must not be used if the diffuser on the LED downlight module has been damaged or cracked. Take care not to pull any electrical wires during unpacking as this may damage the connection. Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement. Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. Installation Directions 1. Remove all packaging material from the product and be careful not to throw away accessories that may be hidden within the packaging material. NOTE: Before installation, plug the fitting into a socket outlet to ensure the LED downlight is working correctly. 2. Cut an installation hole of Ø 145mm into the ceiling (figure 1). 3. Join the connectors together and connect the fitting plug to the socket outlet. (figure 2). 4. Push the springs up and put the LED downlight module up through the cut-out hole and into the ceiling (figure 3). 5. Ensure all the clearance values are maintained during and after installation of the LED downlight module, LED driver, thermal insulation, loose fill insulation, loose combustible materials and any structural members. Please refer to the Clearance Information section and the IC section in this instruction manual for further details. 6. After the installation, switch on the fitting to test all the lighting functions and enjoy your new lighting product. 2 P a g e v 1.1 P u b l i s h e d on 0 3. 2 0 1 6

Clearance Information AS/NZS 3000 Wiring Rules LOCATION DISTANCE DESCRIPTION A B C D 50 mm (Minimum) 50 mm (Minimum) 0 mm (Abutted) 50mm Clearance between the top of the recessed luminaire and any combustible materials, building elements or objects above it. Clearance between the side of the recessed luminaire and any combustible materials, building elements or objects. Insulation can be abutted against the side of recessed luminaire and covered as per IC Rating. See IC Rating section for more details. Auxiliary equipment/driver/transformer must be placed 50mm away from the luminaire. It must be placed on top of thermal insulation and ensure it is not covered. IC Rating Amendment A of AS/NZS 60598.2.2 (Insulation R-Value 3.5 for Australia) 1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it; 2. Type IC recessed luminaire can be used together with building insulation that can safely be exposed continuously to temperatures up to 90 C may abut and cover the luminaire; Note: The insulation material must be glasswool insulation batts type, with maximum R-value 3.5. 3. The declared IC rating is based on the default testing ambient temperatures 25 C according to the standard. RISK OF FIRE Required clearance from structural members and building elements SCB = 50 mm HCB = 50 mm Safety tips Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning or making any adjustment to the fitting. To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power. Select a suitable location away from liquids and hazards. Ensure that the fitting does not come in contact with corrosive chemicals, etc. To clean, wipe with a damp clean cloth. Never soak the fitting with water. Troubleshooting 3 P a g e v 1.1 P u b l i s h e d on 0 3. 2 0 1 6

PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Check your circuit breaker/safety switch box and turn on power to your circuit. Does not work. (New installation) Does not work. (Existing installation) Wiring loose or no power to the downlight. No power to the downlight. Unplug the downlight and test in a functional socket outlet with power. If the downlight does not switch on then contact your nearest Beacon Lighting store. If the downlight is working, have your licensed electrician check the wiring or socket outlet to the downlight. Check your circuit breaker/safety switch box and turn on power to your circuit. Contact your nearest Beacon Lighting store. Flickers when dimming. (New installation) Flickers when dimming. (Existing installation) Buzzing sound. Uneven light start up. Non-recommended dimmer used. Some dimmers have a variable loading adjustment function. eg. Lucci LEDlux SKU# 290998 dimmer. This may not have been adjusted during the installation of the dimmer. Dimmer position on low. Non-tested dimmer used. Dimmer position on low when switched on. Check the dimmer used. Ensure the dimmer used is on the list of recommended dimmers in this manual. The variable resistor needs to be adjusted to suit the downlight load to reduce the flickering. Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level. Check the dimmer used. Ensure the dimmer used is on the list of tested dimmers specified in this manual. Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level. Specifications SKU # 170577 170578 Rated Voltage INPUT: 220-240V~ 50Hz, OUPUT: 33-40VDC, 0.45A, constant current, Rated Wattage 20W 4 P a g e v 1.1 P u b l i s h e d on 0 3. 2 0 1 6

LED Specs LG LED, 3000K, 1400 lumens LG LED, 4000K, 1400 lumens Dimmer Information Weight Cut-out Size IP Rating Dimensions Serviceable Parts LED Driver Model # Lucci LEDlux SKU# 290998 dimmer (Highly Recommended) Clipsal 32E450TM, Clipsal 31E2RUDM, Clipsal 32E450UDM (Compatible) (Please refer to the Installation Requirements or Troubleshooting section in this manual for more information on the tested dimmers, performance, operation and tips.) 0.27kg Φ145mm IP20 D:170mm x H:55mm LED downlight module and LED driver are both serviceable. QM-P12X2W-FR 5 P a g e v 1.1 P u b l i s h e d on 0 3. 2 0 1 6