Operation and Maintenance Manual

Similar documents
Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

GE Industrial Solutions Retrofill Door Assemblies for AKD-5, AKD-6, AKD-8 and AKD-10

GE CONSUMER & INDUSTRIAL

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

SecoVac * Ground & Test Device

Programmer Disconnect Accessory Manual for Retrofil CB

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

Finger Cluster Replacement Parts Primary Disconnects for EntelliGuard* Retrofill Circuit Breakers

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

Power Break Circuit Breakers

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Universal Tall HoneyBadger Chase Rack Installation Instructions

Installation Instructions

GEH-6259 Installation Instructions Voltage Conditioner Assembly

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Safe-T-element Installation Instructions

Installation Instructions For Motor Control Center (MCC) Units

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

Hunter Automatics HA-8. Installation Manual

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

ibusway for Data Center

Zone Selective Interlock Module. For GE Circuit Breakers

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

EntelliGuard R Retrofill Application Guide

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Cradle Mounted Key Interlock Guide Frame Accessory

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

IB PowlVac ITE-HK Remote Racking Device

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Vacuum Circuit Breaker (Vehicle)

POWER GEAR SLIDE-OUT MANUAL

IL 33-DRC-1 Retrofit System for Westinghouse and Cutler-Hammer DS Power Circuit Breakers. Table of Contents

Universal Retrofit System Installation Instructions Revised:

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS RATTLER STEEL RUNNING BOARDS FORD TRANSIT VAN (FULL SIZE)

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

Spectra Series Power Panelboards. General. Installation. Bolt-On Circuit Breaker Kits. DEH059 Installation Instructions

Low Voltage Power Circuit Breakers

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

HITCH INSTALLATION INSTRUCTIONS TESLA MODEL 3 PACKAGE: RACK Present MODEL/TRIM: MAKE: YEARS: 2 HOURS TOOLS REQUIRED: PARTS SUPPLIED:

Installation Sheet January, 2016 Supersedes February, 2013

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

DEH g Installation Instruction for Cable Operator Mechanisms for SE150, SF250, SG600 & SK1200 Spectra RMS Circuit Breakers

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Embedded Rack Slide-out System

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

920 Remote Control Switches

Installation Instructions

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

(W) INSTALLATION INSTRUCTIONS GRILLE GUARD 2014 GMC SIERRA 1500 EXCLUDES DENALI PART # /

Vacuum Circuit Breakers (Vehicle)

Installing the PBX04 Push Bumper on the 2015 Chevrolet Suburban/Tahoe

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Vacuum Circuit Breakers (Vehicle)

Service/Installation Manual Full Wall Slide Systems

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions

Winch Mounting Plate for Wrangler

CR193 B,C,D and E Vacuum Limitamp * Contactors

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS

Type 38-3AH3 38 kv vacuum circuit breaker instruction manual. Installation operation maintenance E50001-F710-A238-V1-4A00. Answers for energy.

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS GRILLE GUARD GMC SIERRA 1500 EXCLUDES DENALI PART # 4084/

LED IMPORTANT SAFETY INSTRUCTIONS

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

Plasma Dual Swing-Out (PDS Series) Wall Mount

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

INSTRUCTIONS INSTRUCCIONES CONSIGNES

S&C Type FVR Substation Circuit Breaker

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Pressure Makeup Jockey Pump Controller

Service/Installation Manual Full Wall Slide Systems CONTENTS. 82-S0379 Rev 3. Page. Before you operate the slide system 2

GT Mustang Shaker

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Transcription:

DEH-41482 GE Energy Industrial Solutions Low Voltage Switchgear Remote Racking Operator For AKR Circuit Breakers Cat. # AKREGRR 115 VAC, 60/50 Hertz Operation and Maintenance Manual

TABLE OF CONTENTS Section 1. Introduction...3 Section 2. Receiving, Handling and Storage...3 Section 3. Description...4 Section 4. Modification...10 2

Section 1. Introduction Remote Racking Operator for AKR Breakers The remote racking operator allows the user to move a drawout circuit breaker between the CONNECT, TEST, and DISCONNECT positions via an electric racking motor and gearbox attached to the front of the breaker. The remote racking operator requires 115Vac, 50/60Hz control power. A control box connected to the operator with a thirty-foot cable permits control from a remote location. Section 2. Receiving, Handling and Storage 2-1 Receiving and Handling Each remote racking operator is carefully inspected and packed for shipment. Immediately upon receipt of the device, an examination should be made for any damage sustained in transit. If damage or rough handling is evident, a damage claim should be filed immediately with the transportation company, and the GE Distributor should be notified. The device should be removed from the shipping box with sufficient care so that no damage will result from rough handling. Loose parts associated with the apparatus may be included in the box. Care should be taken to make certain that these parts are not overlooked. The shipping box will include the remote racking device, two couplers, two mounting brackets, and one mounting plate to be used with AKR 30/50 breakers only. The bracket for the AKR 30/50 breaker has a long shaft that is welded to it while the bracket for the AKR 30S, 75/100 and 125 breaker has a short shaft welded to it as shown in Figure 1. Remove the two wing nuts and washers that are attached to the motor. Align the two holes in the bracket with the studs on the racking motor. Reattach and tighten the two washers and wing nuts to the motor. Assemble the support plate to the AKR 30/50 bracket only by using the ¼-20 hardware that was supplied and tighten. Prior to the initial use of the remote racking operator, a one time modification must be made to each breaker and breaker compartment door. The remote racking operator is portable and is designed for attachment to the AKR Low Voltage Circuit Breaker in AKD-8 Switchgear. For all AKD-6 applications, contact a GE Distributor. Support Plate AKR 30/50 Bracket AKR 30S, 75/100 and 125 Bracket Figure 1 AKR Racking Operator Remove Wing Nuts 2-2 Storage The remote racking operator should be protected against condensation, preferably by storing it in a warm, dry environment at moderate temperatures such as 40 degrees F to 100 degrees F. The storage area should be clean and contain no corrosive gasses. If the device is stored for any length of time, it should be inspected prior to use to insure its proper mechanical and electrical working condition. 3

Section 3. Description 3-1 Description of Small Frame Remote Racking Operator 800A-2000A AKR Breakers The remote racking operator consists of a drive train, control switches, and attachment brackets. The drive train is made of a gear motor housing (1, Fig. 2), and a square drive coupler (2, Fig. 2), which couples to the breaker drawout mechanism. Two control switches and a circuit breaker are included with each remote racking operator. The start switch (3, Fig. 2) housed in the handheld box (4, Fig. 2) controls the power to the motor. Pushing the button closes the switch and in turn supplies power to the motor. This control switch is spring loaded; therefore, continuous pressure on the button is required to keep the motor running. The motor directional toggle switch (5, Fig. 2) is mounted on the motor housing. Two positions are provided, IN and OUT. For racking toward the CONNECT position, the switch should be set to IN. For racking toward the DISCONNECT position, the switch should be set to OUT. The circuit breaker (6, Fig. 2) senses the motor stall current when the breaker reaches the end of its travel, which causes the motor to stall. The higher motor stall current trips the circuit breaker to the OFF position and in turn shuts off the power to the motor. The latch rod (7, Fig. 2) is designed to provide the means for attaching the remote racking operator to the front of the Small Frame Breaker. The latch rod (7, Fig. 2) hooks into the breaker mounting clip (8, Fig. 2) for mounting the remote racking operator to the breaker. Modification to Existing Small Frame Breakers Before attaching the remote racking operator to the existing AKR 30/50 and AKR 30s breakers, mounting brackets must be added to the Remote Racking Operator for AKR BREAKERS breaker. On the AKR 30S breaker, a mounting bracket must be mounted on the right side of the breaker just above the existing racking screw. Refer to page 6 for the installation instructions and kit number. On the AKR 30/50 breaker, a mounting bracket must be added to the left side of the escutcheon on the breaker frame. Refer to page 7 for the installation instructions and kit number. Refer to pages 12 and 13 for field modification to existing breaker doors. ATTACHING / REMOVING DEVICE Attaching the Remote Racking Operator to the Small Frame AKR circuit breaker. The circuit breaker must be in the OPEN position before attempting to attach the remote racking operator to the breaker. On the AKR 30/50 breaker, push the trip button and slide the racking screw cover in the breaker escutcheon to the right. Next, slide the remote racking attachment cover on the cubicle door to the left. This will expose an opening in the breaker cubicle door. On the AKR 30S breaker cubicle door, slide either the upper or lower racking screw access cover (located on the upper right corner of the breaker cubicle door) to the left. This will expose two openings in the cubicle door. Position the remote racking operator so that the square drive coupling is aligned with the square shaft of the drawout (racking) mechanism and the ¼ -turn latch rod engages the breaker frame. Push the remote racking operator toward the breaker to engage the square drive coupling with the shaft of the racking mechanism. If the coupling and the shaft are not in alignment, rotate the motor shaft extension on the back of the motor housing in either direction until the square drive aligns with the square racking shaft. When they are in alignment, the remote racking operator 4

will slide further through the breaker cubicle door. Rotate the ¼ - turn latch rod counter clockwise to lock the remote racking operator to the breaker. Check the latch on the left side of the remote racking operator to make sure it is fully engaged into the breaker front cover (indicated by the label on the latch). Remote Racking Operator for AKR Breakers Removing the Remote Racking Operator from the Small Frame AKR Circuit Breaker. Hold the remote racking operator securely and rotate the latch release (located on the left side of the remote racking operator) clockwise. This should allow the remote racking operator to be pulled from the breaker front cover. The racking screw access covers will close automatically. 6- Circuit Breaker Reset Toggle Switch 8 Breaker Mounting Clip AC Plug 2 Square Drive Coupling To Breaker 7 ¼ turn latch/rod to mount to breaker 30-foot cable 3 Start Switch Push Button 1 Gear Motor Housing 5 IN/OUT Directional Toggle Switch Figure 2 AKR 30/50 Remote Racking Assembly 5 4 Hand-Held Control Box

Installation of the AKR 30S Remote Racker Mounting Bracket Kit AKR30SEGBRMOD Locate the (2) 3/8 inch bolts on the right side of the frame under the racking mechanism assembly. Carefully loosen these two bolts in order to slide the remote racking bracket (supplied with kit) behind the lock washer that is on the bolt. See below for location of the bolt heads on the breaker frame. Be careful not to remove these bolts. Slide the bracket behind the lock washers on to the bolts and then retorque the bolts to 25 35 ft.-lbs. Do not over torque. Check to see that the bracket is completely vertical before tightening. If not, this will cause improper alignment of the remote racking shaft. The breaker may now be reinstalled into the cubicle. The existing racking screw mechanism needs to be inspected for excessive wear and be properly lubricated. Mounting Bracket Loosen these (2) bolts Figure 3 AKR 30S Mounting Bracket Installation 6

Installation of the AKR 30/50 Remote Racker Mounting Bracket Kit AKR3050EGBRMOD When looking at the front of the breaker, locate the (2) mounting holes that are already punched in the frame on the left side of the escutcheon. They are located behind the nameplate on the breaker. Install the mounting bracket that came with your kit. Align the (2) holes on top of the bracket with the (2) holes on the frame. Install the (2) ¼- Remote Racking Operator for AKR Breakers 20 flat washers, lock washers and bolts through the frame and into the bracket. Torque the bolts to 7 10 ft.-lbs. Do not over torque. Make sure that the flat portion of the bracket with the key way is facing outwards. See picture below. After the bracket has been mounted, the breaker is ready to be installed into the cubicle. The existing racking screw mechanism needs to be inspected for excessive wear and be properly lubricated. Nameplate Mounting Bracket Figure 4 AKR 30/50 Mounting Bracket Installation 7

3-2 Description of Large Frame Remote Racking Operator 3200A-5000A AKR Breakers The remote racking operator consists of a drive train, control switches, and attachment brackets. The drive train is made of a gear motor (1, Fig 5) a square drive socket (2, Fig 5), which couples the breaker. Two toggle switches and a circuit breaker are included with each remote racking operator. The START switch (3, Fig 5) housed in the handheld box (4, Fig 5) controls the power to the motor. Pushing the button closes the switch and in turn supplies power to the motor. This control switch is spring loaded; therefore, continuous pressure on the button is required to keep the motor running. The motor directional toggle switch (5, Fig 5) is mounted on the motor housing. Two positions are provided, IN and OUT. For racking toward the CONNECT position, the switch should be set to IN. For racking toward the DISCONNECT position, the switch should be set to OUT. The circuit breaker (6, Fig 5) senses the motor stall current when the breaker reaches the end of its travel, which causes the motor to stall. The higher motor stall current trips the circuit breaker to the OFF position and in turn shuts off the power to the motor. The ¼ turn shaft (7, Fig. 5) is designed to provide the means for attaching the remote racking operator to the front of the Large Frame Breaker. The latch rod (7, Fig. 5) hooks into the breaker connecting bracket for mounting the remote racking operator to the breaker. Remote Racking Operator for AKR Breakers ATTACHING / REMOVING DEVICE Attaching the Remote Racking Operator to the Large Frame AKR Circuit Breaker The circuit breaker must be in the OPEN position before attempting to attach the remote racking operator to the breaker. Slide either the upper or lower racking screw access cover (located on the upper right corner of the breaker cubicle door) to the left. This will expose two openings in the breaker cubicle door. The upper opening is for the ¼-turn latch rod and the lower opening is for the square drive coupling. Position the remote racking operator so that the square drive coupling and ¼-turn latch rod are aligned with the openings in the breaker cubicle door. Push the remote racking operator toward the breaker so that the square drive coupling engages the square racking shaft and the ¼- turn latch rod engages the breaker frame. If the coupling and the shaft are not in alignment, rotate the motor shaft extension on the back of the motor housing in either direction until the square drive aligns with the square racking shaft. When they are in alignment, the remote racking operator will slide further through the breaker cubicle door. Rotate the ¼-turn latch rod counter-clockwise to lock the remote racking operator to the breaker. Removing the Remote Racking Operator from the Large Frame AKR circuit breaker Hold the remote racking operator securely and rotate the ¼-turn latch rod clockwise to release the remote racking operator from the breaker. Pull the remote racking operator away from the breaker cubicle door. The racking screw access covers will close automatically. 8

Racking Screw Access Hole 7-1/4 turn latch/rod to mount to breaker 1 - Motor and Gear Housing 6 - Circuit Breaker Reset Toggle Switch 5 - IN/OUT Directional Toggle Switch 2- Square Drive Coupling to Breaker 3 - Start Switch Push Button 4- Hand Held Control Box Figure 5 AKR 30S, 75/100 and 125 Remote Racking Assembly 9

Section 4. Modifications 4-1 Converting Large Frame Breaker to work with Remote Racking Operator Connecting Bracket Align 1 st to existing holes in breaker frame. ¼-20 Bolt, Nut, Lock Washer, Flat Washer Add ¼ inch hardware to existing hole of bracket and frame in upper position as shown. 3/8-16 Bolt, Nut, Lock Washer, Flat Washer Add 3/8 inch hardware to existing hole in bracket and breaker frame in lower position as shown. AKR751008EGBRMOD & AKR125EGBRMOD Modification Kit for AKD-8 AKR 75/100 & 125 Large Frame Breakers Figure 6 Racking Stop Align racking stop with existing hole in breaker frame as shown. 3/8-16 Bolt Add 3/8 inch hardware from inside frame of breaker as shown. 10

4-2 Changing a Small / Large Frame Breaker Door in AKD 8 Switchgear to work with Remote Racking Operator Remote racking attachment access holes AKD-8 Doors Kit AKR30S8EG22DR- 800A AKR 22 Wide Breaker Door Kit AKR30S8EG30DR- 800A AKR 30 Wide Breaker Door Kit AKR30S8EG22DRDI- 800A AKR 22 Wide Breaker Door with Defeatable Interlock Kit AKR30S8EG30DRDI- 800A AKR 30 Wide Breaker Door with Defeatable Interlock Kit AKR30508EG22DR- 800A/1600A AKR 22 Wide Breaker Door Kit AKR30508EG30DR- 800A/1600A AKR 30 Wide Breaker Door Kit AKR30508EG22DRDI- 800A/1600A AKR 22 Wide Breaker Door with Defeatable Interlock Kit AKR30508EG30DRDI- 800A/1600A AKR 30 Wide Breaker Door with Defeatable Interlock Kit AKR751008EG30DR- 3200A/4000A AKR 30 Wide Breaker Door Kit AKR751008EG30DRDI- 3200A/4000A AKR 30 Wide Breaker Door with Defeatable Interlock Kit AKR1258EG38DR- 5000A AKR 38 Wide Breaker Door Kit AKR1258EG38DRDI- 5000A AKR 38 Wide Breaker Door with Defeatable Interlock 11

4-3 Field Modification to existing Breaker doors. All existing small and large frame AKR Breaker doors can be modified in the field to accommodate the new AKR remote racking operator. A drilling template kit (CAT# AKREGDRTEMP) can be provided with (5) drilling templates (one for each type of breaker door). The racking flag assemblies (CAT# AKREGDRMOD) can also be ordered for each modified breaker door. Below is a picture demonstrating how to locate and drill holes in an existing 30S, 75/100 or 125 breaker door. A picture demonstrating how to locate and drill the holes for a 30/50 breaker door is located on the next page. Refer to page 14 for remote racking flag details. Existing breaker compartment door. 2. Align inside edge of template with outer edge of door. 4. Drill (1) 0.251 diameter hole through the door. 3. Drill (1) 1.75 diameter hole through the door. 1. Insert bushing of template into the existing racking hole. Figure 7 Door drilling template for AKR 30S, 75/100 and 125 doors 12

Existing AKR 30/50 breaker door. 3. Drill (1) 0.251 diameter hole through the door. 2. Drill (1) 1.75 diameter hole through the door. 1. Place the bottom flange of the template above the bottom edge of the door cutout. Both press studs will be on the inside of the cutout. Figure 8 Door drilling template for AKR 30/50 doors. 13

Top of Door Figure 9 Flag Assembly 14

Aftermarket Solutions available from GE Energy - Industrial Solutions WavePro/EntelliGuard (Entellisys) Remote Racker GEK-99986 EntelliGuard G Remote Racker DEH-41467 EntelliGuard TU Trip Unit Conversion Kits DET-722 Power Break II into a Power Break I Retrofit Kit DEH-41502 EntelliGuard G AK/AKR Retrofills Coming soon 15

These instructions do not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, the matter should be referred to the General Electric Company. GE Industrial Systems 41 Woodford Ave. Plainville, CT 06062 www.geindustrial.com 2010 General Electric Company All Rights Reserved DEH - 41482 16