Designing a Mechanically Adjustable Speed Drive for AC Motor Applications to Eliminate Vibrations Without Additional Harmonics

Similar documents
Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Steve Schouten. Donna Densmore

Jeff Fehr, Senior Application Engineer. ACH550 Flux Optimization White Paper

Product Testing: Magna Drive, Report No.1 Prepared by:

Full Voltage Starting (Number of Starts):

Variable Frequency Drives

AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING. An introduction to reduced voltage starting of three phase induction motors

Single-Phase AC Induction Squirrel Cage Motors. Permanent Magnet Series Wound Shunt Wound Compound Wound Squirrel Cage. Induction.

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

MAGNETIC DRIVE TECHNOLOGY WHEN APPLIED TO BELT CONVEYORS

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

Variable Speed Drives in Electrical Energy Management. Course Content

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

A Practical Guide to Free Energy Devices

How to Select a Variable Frequency Drive Based on Load Characteristics

PI Electrical Equipment - Course PI 30.2 MOTORS

ECE1750, Spring Motor Drives and Other

Efficient Variable Speed Pumping: A Low Cost Approach to Green Energy

Aspects of Permanent Magnet Machine Design

ENERGY EFFICIENCY MADE EASY. Flux Drive FAQs. Frequently Asked Questions VERSION 2.0 GENERAL PRODUCT QUESTIONS... 2 COMPLIANCE AND DESIGN...

CHAPTER 1 INTRODUCTION

Technology Demonstration of Magnetically-Coupled Adjustable Speed Drive Systems

ESO 210 Introduction to Electrical Engineering

VFD Best Practices: Getting the Most from Your VFD Investment

1.1 Block Diagram of Drive Components of Electric Drive & their functions. Power Processor / Modulator. Control. Unit

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

AC Adjustable Speed Drives (ASD s)

MULTIOPERATIONAL ELECTROMAGNETIC FORMING MACHINE

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Getting the Speed Right. Voith Variable Speed Fluid Couplings

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

Model Dual Function Planetary Gear Reducer

INTRODUCTION. I.1 - Historical review.

You have probably noticed that there are several camps

Modern Design for Variable Speed Motor-Generators:

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

Motor Basics AGSM 325 Motors vs Engines

Chapter 3.2: Electric Motors

Armature Reaction and Saturation Effect

How flexible shafts. improve flight. inside: Leadersh Winners Pages December Motion Control: p.

Common recommendations

VARIABLE SPEED DRIVES AND MOTORS

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

2014 ELECTRICAL TECHNOLOGY

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Introduction. Upon completion of AC Motors you should be able to: Explain the concepts of force, inertia, speed, and torque

Regulation: R16 Course & Branch: B.Tech EEE

A Practical Primer On Motor Drives (Part 11): AC And DC Motor Types

Lower-Loss Technology

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Motor Protection Fundamentals. Motor Protection - Agenda

PAC TRAINING PUMP MOTORS

Motors and Variable Speed Drives for Pumps and Fans. Reid Hart, PE

SUPPRESSING ACOUSTIC NOISE IN PWM FAN SPEED CONTROL SYSTEMS APPLICATION NOTE 58 SUPPRESSING ACOUSTIC NOISE IN PWM FAN SPEED CONTROL SYSTEMS AN-58

VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS

PRODUCT SPECIFICATIONS

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

ECET Industrial Motor Control. NEMA Ratings. National Electrical Manufacturers Association

Lab Electrical Power Engineering I

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Lecture PowerPoints. Chapter 21 Physics: Principles with Applications, 7th edition, Global Edition Giancoli

OVERSIZED DERAILLEUR PULLEY EFFICIENCY TEST

Project Summary Fuzzy Logic Control of Electric Motors and Motor Drives: Feasibility Study

Single Phase Induction Motors

Chapter 3.1: Electrical System

Technical Guide No. 7. Dimensioning of a Drive system

The Advantages of Rotary Direct Drives

It s What s Inside that Counts

Stray Losses in Power Transformers

Industrial Motors. But first..servos!

Cooling Enhancement of Electric Motors

Generating Set considerations. AGN Motor Starting and Generating Set Considerations

Advantages of a Magnetically Driven Gear Pump By Steven E. Owen, P.E.

TTM-04: The relationship of system efficiency and speed control using VSDs vs. EC motors

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

The development of a differential for the improvement of traction control

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

Effect of Permanent Magnet Rotor Design on PMSM Properties

GNS Series & GNP Series of High-Efficiency IPM Motors

COMPARISON OF ENERGY EFFICIENCY DETERMINATION METHODS FOR THE INDUCTION MOTORS

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Electric Motors and Drives

AGN 041 Alternator Operating Speed

Diesel Generator Set S3.8 Series Engine

IT 318 SUPPLEMENTARY MATERIAL CHAPTER 4

Almost 200 years ago, Faraday looked for evidence that a magnetic field would induce an electric current with this apparatus:

PM Assisted, Brushless Wound Rotor Synchronous Machine

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

Traditional AC Motors: Beyond NEMA Premium Efficiency

Step Motor Lower-Loss Technology An Update

Permanent Magnet Motors for ESP Applications Updating the Track Record of Performance. Lorne Simmons VP Sales & Marketing

Building Bridges to Net Zero Adjustable Speed Motor and VFD Applications and Opportunities in Multifamily Buildings

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

FRENIC-Mega Series of High-performance Multi-function Inverters

Application Information

Hydraulics in building systems. siemens.com/buildingtechnologies

AC Line / Load Reactors

Transcription:

Designing a Mechanically Adjustable Speed Drive for AC Motor Applications to Eliminate Vibrations Without Additional Harmonics Philip Corbin III, Flux Drive Founder/CEO 1. INTRODUCTION: With the advent of high performance permanent magnets, there is a new non-eddycurrent option to achieving adjustable speed control when matching the AC motor output speed to the requirements of the load. This option is cheaper to install, maintain and operate without introducing damaging harmonic frequencies to the motor. The Flux Drive technology utilizes portions of induction motor theory and combines it with recent improvements in permanent magnets to develop a simple but unique magnetic adjustable speed drive (ASD) and soft-start coupling. The following presentation will outline the technology and describe two applications in which this drive was installed. 2. TECHNOLOGY OVERVIEW: This technology demonstrates the efficient use of the highest energy rare earth magnetic materials available (i.e., Neodymium-iron-boron). The robust design is characterized by a primary member populated by easily assembled permanent magnets, and a secondary member relying on casting techniques of an aluminum cage that have been highly refined over a century of induction motor development. The Flux Drive ASD, shown in Figure 1, achieves adjustable speed of the output shafting, by controlling the overlap of a Can containing an optimized array of rare earth magnets, as it spins around a magneto-conductive Rotor. As the Can and Rotor are disengaged, the slip increases, and thus allows the output speed to decrease proportionally. The alignment between the Can and Rotor allows for greater transfer of torque and change in speed as the Rotor enters into the Can. 1 of 19

Figure 1 View of a Flux Drive ASD In Figure 2 a Flux Drive coupling is configured by simply leaving the Rotor fully engaged within the magnet Can. During the motor starting event, the motor shaft commences rotation before the start-up of the Flux Drive coupling, thereby allowing the motor to breakaway from the load and accelerate to full motor speed without locked rotor current. The motor only experiences reduced in-rush current due to the absence of the load and the resulting locked rotor current. This initial quick start of the motor prevents the locked rotor currents from developing in the motor windings since the coupling is spinning freely at this point in time. As a result of these two time-varying events, the motor current is limited to well below the locked rotor value. Testing of the coupling on a 25 HP motor reported in Section 4 Figure 13a shows that the maximum torque developed is 76 ft-lb during the start-up event. In the event that the motor experiences a sudden obstruction to the output rotor, 2 of 19

the maximum torque that it can develop would be no more than the maximum amount that the coupling can transmit. In this case, therefore, the motor torque (and consequently, the current) is limited to the safe value of 134% of its full load rating. This unique feature of the Flux Drive coupling provides an added safety feature to installations that are susceptible to temporary overloads. This feature also reduces torque spikes and torsional vibration that can often be created by the load and therefore protects the motor from damage that often results from a load shaft seizure event. Figure 2 View of a Flux Drive coupling 3. PERFORMANCE: In order to achieve the optimum selection of the Flux Drive products and the particular application, it is important to be familiar with the performance characteristics of this drive s design. The following sections discuss various parameters that constitute the specifications of this adjustable speed drive or coupling. i. Speed/torque characteristics: Both the coupling and ASD have characteristics that are similar in appearance to induction motors but are unlike those of eddy-current couplings. Figure 3 shows the changes in maximum torque capability of these two drives with the slip-speed. The load speed is inversely proportional to the slip-speed since the motor is running at a constant speed. The speed/torque characteristics in Figure 4 were obtained from a test on a Flux Drive coupling and show characteristics similar to those of induction motors. The starting and peak torque values are the familiar saddleback shape that can be modified with appropriate Rotor design changes, as is the case with induction motors. 3 of 19

8 7 6 Torque (ft.lb) 5 4 3 2 1 5 1 15 2 Slip Speed (rpm) FluxDrive Eddy Current Coupling Figure 3 Calculated speed / torque characteristics of a Flux Drive product 12 1 Torque (ft lb) 8 6 4 2 5 1 15 2 Slip Speed (rpm) Figure 4 Experimental speed / torque characteristics of a Flux Drive product 4 of 19

The percentage engagement (i.e., overlap) of the Can with the Rotor determines the amount of torque transmitted from the motor to the load and the speed at which the load shaft will operate. This is an adaptive situation in which the motor and load achieve a steady-state of operation at all engagement positions. The torque of the motor is transmitted without loss to the load via the Flux Drive magnetic circuit at much higher torques and minimal slip. The rating of a Flux Drive ASD or coupling is based on the combination of two major parameters: 1) the maximum torque transmitted, and 2) the slip-speed corresponding to that torque. Figure 5 shows a family of speed/torque curves of a typical ASD drive at various amounts of engagement between Can and Rotor. The general shape of the curves in Figures 3, 4 and 5 differ from each other because they describe the performance of drives with different Rotor cage designs. 3 25 Torque (ft.lb) 2 15 1 5 5 1 15 2 Slip Speed (rpm) 1% 75% 5% 25% Figure 5 Calculated speed / torque characteristics at various % engagements ii. Soft-start characteristics: As mentioned in Section 2 above, the Flux Drive coupling or ASD can be used to softstart a motor s load as well as to adjust its speed. Various parameters were recorded as a 25 HP motor was started with the Flux Drive coupling compared to a standard flexible 5 of 19

coupling. Figure 6 shows that the duration of the high start-up current is reduced substantially and is only a fraction of the time experienced with a rigid coupling. The power input to the motor is also reduced to approximately a third of its value, as seen in Figure 7. This is primarily because of the lower amounts of current necessary to accelerate the output shaft to full speed. The power factor is also improved as seen in Figure 8. Figure 9 shows that for this motor, even though the energy transferred with the Flux Drive coupling takes more than twice as long to complete than with a rigid coupling, the startup power is reduced during most of that time. Start Up Current (A) 25 225 2 175 15 125 1 75 5 25 5 1 15 2 25 Time (s) Flux Drive Rigid Coupling Figure 6 Start-up current with two couplings Power (kw) 35 3 25 2 15 1 5 5 1 15 2 25 Time (s) Flux Drive Rigid Coupling Figure 7 Input power with two couplings 6 of 19

Power Factor 1.8.6.4.2 5 1 15 2 25 Time (s) Flux Drive Rigid Coupling Figure 8 Power factor with two couplings Cumulative Energy (kjoule) 14 12 1 8 6 4 2 5 1 15 2 25 Time (s) Flux Drive Rigid Coupling Figure 9 Shaft energy required to start load 7 of 19

iii. Efficiency: The two types of loss discussed above constitute the total losses of the Flux Drive products. There are no additional losses (i.e., mechanical or electronic) usually found in other types of drive (i.e., eddy-current or VFDs). This fact allows the Flux Drive products to operate at higher efficiencies than other drives with similar loads. The following Figure 11 shows typical efficiency plots for three types of drive. This information was collected from published reports and studies (Ref. 1 & 2). It is clear from these reports and our tests that the Flux Drive products, particularly when used as couplings, have the highest efficiency of all types of coupling, including VFDs and the most modern types of eddy-current coupling. There are of course, many disadvantages associated with the other drives as noted and discussed in Section 6 below. Efficiency 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% % 5 1 15 2 Slip Speed(rpm) FluxDrive MagnaDrive Eddy Current Coupling Figure 11 Efficiency plots of ASDs iv. Affinity Laws: 8 of 19

Centrifugal loads follow what are called affinity laws. According to these laws, the changes in fluid-flow are proportional to speed. However, the required torque is proportional to the square of the change in speed and the horsepower is proportional to the cube of the change in speed. These relationships are confirmed by test as part of the performance of a Flux Drive product as seen in the following Figure 12. Fan and Pump Load Characteristics vs Law of Affinity 3 25 2 HP 15 1 5 5 1 15 2 Load speed (rpm) Fluxdrive Law of Affinity Figure 12 Flux Drive vs. Laws of affinity 4. COMPARISONS: A 3-phase, 177 rpm, 25 HP induction motor driving a blower was utilized during extensive testing of a Flux Drive ASD. A commercially available VFD of the similar power rating was also tested when connected without the Flux Drive ASD, using the same blower load. The test conditions were similar for both drives as shown in Figures 13 a&b. Torque and percentage slip were plotted against output power indicating that the load characteristics were constant. 9 of 19

8 7 6 Torque (ft lb) 5 4 3 2 1 5 1 15 2 25 3 Output (HP) Flux Drive VFD Slip (%) 5 45 4 35 3 25 2 15 1 5 5 1 15 2 25 3 Output (HP) Figure 13 a&b Load conditions for both drives The VFD rms current plotted in Figure 14 was measured with and without line reactors. The effect of improving the power factor by the line reactors is reflected in the lower values of current. This is confirmed by the comparison in power factor data plotted in Figure 15. When using a Flux Drive ASD, the addition of power factor correction equipment is totally at the discretion of the user. The Flux Drive ASD provides an alternative advantage to the system: the preservation of low % total harmonic distortion (%THD). This is seen in Figure 16. The %THD is 1 of 19

defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency (Ref. 3). It is understood that the power factor is primarily influenced by the motor inductance, in contrast with the %THD which is a description of the harmonic content of the waveform. The measurement technique of these parameters is a complex task and is admittedly beyond the scope of this presentation. 35 3 25 Current (A rms) 2 15 1 5 5 1 15 2 25 3 Output (HP) Flux Drive VFD No Reactors VFD With 1 Reactor Figure 14 RMS current of both drives 11 of 19

Power Factor 1..95.9.85.8.75.7.65.6.55.5 5 1 15 2 25 3 Output (HP) Flux Drive VFD No Reactors VFD With 1 Reactor Figure 15 Power factor of both drives %THD Amp 14 12 1 8 6 4 2 5 1 15 2 25 3 Output (HP) Flux Drive VFD No Reactors VFD With 1 Reactor Figure 16 % THD of both drives 12 of 19

The major pieces of equipment used are as follows: 1. Motor: WEG Model 2518EP3E284T, 284T Frame, 25 HP, 176 RPM, 46 V, 29.6 A,.85 PF 2. Load: Penn and Barry Blower, Size 21-61-AH, Class 15, APR- 1CW, Sheave Ratio 1.38:1 3. Torque Transducer: Binsfield Engineering Inc., Transmitter Model TX1K-S Receiver Model RX1K 4. VFD: Automation Direct - Dura Pulse Drive, Model GS3-425, Rating -48 V, 25 HP, 38 amp, 28.9 KVA, 3 Phase, Frequency Range.1 to 4 Hz 5. Line Reactors: Automation Direct, Model GS-425-LR, Type JR, 3 Phase, Dry Type, Iron Core Reactor 6. Dranetz: Model PowerXplorer PX5 Meter 13 of 19

5. CASE STUDIES: Flux Drive products have been installed in locations where they are relied upon for continuous operation after having shown measurable improvement in the performance compared to previously installed drives. i. Blower Application: A Flux Drive coupling was installed between a 2 HP motor and a blower in a 3-yearold boiler room. Figures 18 a&b below show the old fluid drive coupling and the replacement Flux Drive installation, respectively. This application is a 2hp, 175 rpm motor driving a Forced Draft Fan for a small boiler through a fluid drive for speed control. The fluid drive is controlled by a pneumatic actuator that regulates the fan speed and airflow to the boiler. Figure 18a old boiler coupling 14 of 19

Figure 18b Flux Drive coupling ii. Pump Application: A Flux Drive coupling was installed between a 2 HP motor and a pump at an aquarium. Figures 19 a&b below show the old flexible coupling and the replacement Flux Drive installation, respectively. The pump serves to circulate saltwater to an underwater dome exhibiting marine life that requires reliable operation. 15 of 19

Figure 19a old aquarium coupling Figure 19b Flux Drive coupling 6. CONCLUSION: The goal in developing the Flux Drive technology was to provide an alternative to current speed control options with similar or better performance. The result is a coupling and ASD with the following features: Reduce power required to operate machinery at variable speeds compared to VFDs and eddy current couplings, Eliminate introducing harmonic frequencies that cause distortion in the electrical systems Eliminate the need to install complex electronic filtering systems to reduce %THD to acceptable levels Reduce the ambient noise associated with VFDs and other competitive products, Reduce the life cycle costs of replacing and repairing expensive electronic components of other drives, Reduce peripheral costs (e.g., separate Filter rooms and air conditioning) involved with introducing a single (or multiple) VFDs to a system requiring speed control, Provide cost effective operations in harsh environments (saltwater, gases, etc.). Allow medium and high voltage applications to have an ASD that does not increase in price dramatically due to the higher voltage requirement of electronic drive products. 16 of 19

7. REFERENCES: [1] Product Testing: Magna Drive, Motor Systems Resource Facility, Oregon State University, Report #-48, March 2. [2] Technology Demonstration of Magnetically-Coupled Adjustable Speed Drive Systems, Pacific Northwest National Laboratory, PNNL-13879, June 22. [3] Power Quality Look Beyond the Symptoms, Plant Engineering Web cast, event was broadcast on December 11, 28 17 of 19