1-106-EN Chain lubrication, accessories Nozzles, oiling brushes, reservoirs and other accessories for chain lubrication
Oil projection nozzle AC-A Compact design, pinpoint accuracy, and high temperature resistant, the projection nozzles AC-A are perfectly suited to aggressive surroundings. These nozzles spray, straight and without air, microdosis of oil under pressure, which are delivered by pneumatic or electromagnetic micropumps. The spray distance can vary from a few centimeters up to several decimeters. AC-A nozzles spray mineral or synthetic oil with a viscosity of 100 mm 2 /s at 0 C. The metered volumes range from 10 to 60 mm, according to the model. Nozzles have a metallic casing and are equipped with a check valve. They have fluorocarbon seals (FPM), although not in high temperature applications. They are fed via tubes Ø 0,75 with a max. length of m. Note The tubes have to be imperatively metallic, as direct as possible, and without connectors on the pump/nozzle line. The inner diameter of the tube shall not exceed mm. Order information Order No. Volume possible [mm /stroke] Number of outlets Valve* [bar] Temperature [ C] Seal Fixing Weight [g] AC-A-0 0/60 2 6 10 to 220 FPM Ø / Ø 8 1 52 AC-A-06 20/0 1 6 10 to 220 FPM M 8 1,25 22 AC-A-16 0/60 1 6 10 to 220 FPM M 8 1,25 25 AC-A-06-BP 20/0 1 10 to 250 M 8 1,25 21 *) Valve setting at 20 C for an oil with recommended viscosity AC-A-0 AC-A-06 (17,) () Ø2,5 (Ø0,5) Ø2,5 (Ø0,5) H.10 H.12 (M8 1) H.10 ~57,5 H.10 H. 16,5 0,8 Ø 7 ~ 0 H.9 H.10 H.1 1 10 6 12,5 M8 max. 2 1-106-EN
AC-A-16 AC-A-06-BP () () Ø2,5 (Ø0,5) Ø2,5 (Ø0,5) H.10 H.9 H.10 H.9 H.10 H.10 ~ H.1 ~ 0 H.1 1 10 M8 max. Fixation support Fixation support (nut and adjustable support for threaded nozzles) Order No.... UC-1065 UC-1065 (Ø) (Ø) (9) (27) (M8) (M8) (27) (12) (2,) (M6) 28 (1) 56 12 1 25 10 8,5 (10) 6,5 10 160 16 10,5 M8 max. (AC-A-06) (AC-A-06-BP) (AC-A-16) (8,5) 1-106-EN
Oiling brushes Oiling brushes UC are used to apply lubricant to a chain. They ensure a constant lubricant film on the chain. These brushes are available in different shapes and sizes and with different materials (bristle, brass or polyamide) in order to better meet the customers chain needs and specifications. The brushes are fed with tubes Ø x 0,75. Brushes are delivered without bracket supports, which have to be ordered separately. Order information Order No. Shape Sizes [mm] Temperature [ C] Brush material Fixing [mm] Weight [g] Bracket support Order No. UC-1066-01 55 16 10 to 60 Bristle Ø 8,5 110 AC.2879 UC-1066-02 55 16 10 to 200 Brass Ø 8,5 160 AC.2879 UC-1066-0 Ø 0 10 to 60 Bristle Ø 19 85 UC.1010.100 UC-1066-0 Ø 10 to 60 Bristle Ø 12,5 5 AC.98 UC-1066-05 Ø 10 to 80 Polyamide 6.6 Ø 12,5 5 AC.98 UC-1066-06 55 16 10 to 80 Polyamide 6.6 Ø 12,5 5 AC.2879 UC-1066-01 ; UC-1066-06 UC-1066-02 6 Ø5,5 Ø6 5,5 101 25 ~55 ~17 85 min. / max. 70 ~55 ~17 85 min. / max. 70 7 109 25 1-106-EN
UC-1066-0 UC-1066-0 ; UC-1066-05 Ø9 Ø9 Ø0 5 65 1 60 Ø 50 6 25 0 min. 1 / max. 80 85 min. / max. 70 Retractable oiling brushes AC-A-216 Retractable brushes with volumetric oil supply are driven by a motor pump. These brushes, which are controlled by a control unit, are only in contact with the chain during lubrication. This control unit can set the brushes contact time with the chain, the oil injection frequency and the time between two lubrication phases. When paused, the brushes are lifted up to limit wear. Model AC.A.210: retractable brushes without metering unit. Order information Order No. Shape Volume [mm ] Quantity Sizes [mm] Temperature [ C] Brush material Fixing [mm] Ø tube [mm] Weight [g] AC.A.216.20 20 2 55 16 10 to 60 Bristle 2 Ø 6,5 8 1 90 AC.A.216.0 0 2 55 16 10 to 60 Bristle 2 Ø 6,5 8 1 90 AC.A.210 55 16 10 to 60 Bristle 2 Ø 6,5 8 1 and 0,75 600 1-106-EN 5
Oil reservoirs These reservoirs, with a capacity of, l to 20 l, supply lubricant to the pneumatic or electromagnetic pumps of the chain lubrication system. They can be equipped with a stopcock valve to be used during maintenance on the lubrication system. The lubricant minimum level can be visually (sight glass) or electrically (level switch) monitored. As an option, reservoirs can include an electric preheating device to maintain the lubricant at the optimal operating temperature. It is also possible for reservoirs to come with level switches with two switching points (warning and minimal). Order information Order No. Capacity [l] Material Min. Level switch Stopcock valve Filter [µm] Service temperature [ C] Weight (ca.) [kg] TK-0-VMC, PE 200 (outlet) 10 to +60 1,2 TK-80-V 10 aluminum 00 (inlet) 10 to +60 6,255 TK-80-VM 10 aluminum 00 (inlet) 10 to +60 6,0 TK-90 20 aluminum 00 (inlet) 10 to +60 TK-0-VMC TK-0-VMC 1. Filling plug with filter 2. Min. level switch (with connector), NO, when the min. level is reached, the contact opens. Stopcock valve. Outlet port with filter G 1/, max. depth 9 mm 28 ~27 1 178 16 210 2 PG9 5 H.21 16 Ø7 7 16 168,5 200 16 56 127 6 1-106-EN
TK-80-V / -VM TK-80 1. Min. level switch (with connector), changeover switch 2. Breather. Filling port Ø RP 1/. Filling plug with filter 5. Sight glass 6. Outlet port G 1/ 7. Stopcock valve 25 10 286 2 Ø11 50 255 PG11 19 Level switch When min. filling level is reached. contact 1 2 opens contact 1 closes 278 (5) (22) 5 7 5 266 (~298) 6 1 2 2 1 option (60) TK-90 TK-90 1. Breather 2. Filling plug with filter. Sight glass. Min. level switch (with connector), changeover switch 5. Outlet port G 1/, max. depth 9 mm 6. Stopcock valve Level switch When min. filling level is reached. contact 1 2 opens contact 1 closes 2 1 02 90 12 66 102 286 PG11 60 280 2 8 Ø11 6 1 6 19 5 1-106-EN 7
Proximity switches The inductive proximity switches are essential for chain lubrication systems. They accurately detect, without any mechanical contact with the chain, the position of the lubrication points on the running chain. When a lubrication point has been detected, the proximity switch sends a signal to the control unit, which triggers a lubrication impulse (actuation of the pump). The proximity switches are delivered with a connector or a cable, and a bracket support. Order information Order No. Type Nominal sensing distance (Sn) Operating voltage Service temperature [ C] Housing UC-1060-11 wires, PNP, NO mm 12 to 2 V DC 25 to +80 plastic, IP67 UC-1060-1 wires, PNP, NO 5 mm 10 to 0 V DC 0 to +175 metal, IP67 UC-1060-16 wires, PNP, NO 5 mm 12 to 8 V DC 25 to +80 metal, IP68 UC-1060-17 2 wires, NO 5 mm 2 to 20 V AC / 2 to 210 V DC 25 to +80 metal, IP68 UC-1060-19 wires, PNP, NO 10 mm 10 to 0 V DC 25 to +70 metal, IP67 UC-1060-11 washer M6 HALFEN 8,5 0 rail HALFEN 28 (welded on the machine) 77 (60) UC-1060-1 washer M6 HALFEN 8,5 7,5 25 160 (28) 19 9 (28) 19 1 2 Connector PG7 5 58 (M0 1,5) (1,5) 6 50 20 72 110 PNP NO wiring diagram brown/1 (BN) (power) black/ (BK) (Signal) blue/ (BU) (power) load + Ø,7 - rail HALFEN 28 5 m 80 10 70 58 (M18 1) (28) (2) 20 72 110 wiring diagram brown/1 (BN) (power) black/ (BK) (Signal) load blue/ (BU) (power) 8 1-106-EN
UC-1060-16 0 washer M6 HALFEN (28) 8,5 19 rail HALFEN 28 (welded on the machine) 100 82 50 58 (M18 1) (27) (2) 20 72 110 wiring diagram brown/1 (BN) (power) black/ (BK) (Signal) load blue/ (BU) (power) Connector PG7 washer M6 HALFEN 8,5 0 UC-1060-17 (28) 19 rail HALFEN 28 (welded on the machine) 60 58 (M18 1) (27,7) 20 72 110 brown/2 (BN) blue/ (BU) load,8 51,5 wiring diagram Ø cable 2 0,5 mm², 2m UC-1060-19 washer M6 HALFEN 8,5 0 (28) 19 rail HALFEN 28 (welded on the machine) ~88 (~71) 5 50 58 (M0 1,5) (1,5) 6 50 20 72 110 wiring diagram brown/1 (BN) (power) black/ (BK) (Signal) load blue/ (BU) (power) connector PG7 1-106-EN 9
Connection kits: reservoir / pump SKF offers several kits to connect the reservoir to the pump(s) PE. These kits differ differ depending on the outlet G 1/ used (straight or elbow) and the number of pumps. Order information Order No. Reservoir outlet Pump(s) Description UC-1070-1 straight 1 straight connector ( 1), copper seal ( 1), steel tube (1 m), banjo fitting ( 1) UC-1070-2 straight 2 straight connector ( 1), copper seal ( 1), steel tube (1 m), banjo fitting ( 2), tee connector ( 1) UC-1070- straight straight connector ( 1), copper seal ( 1), steel tube (1 m), banjo fitting ( ), cross connector ( 1) UC-1070- straight straight connector ( 1), copper seal ( 1), steel tube (1 m), banjo fitting ( ), tee connector ( ) UC-1071-1 elbow 1 elbow connector ( 1), steel tube (1 m), banjo fitting ( 1) UC-1071-2 elbow 2 elbow connector ( 1), steel tube (1 m), banjo fitting ( 2), tee connector ( 1) UC-1071- elbow elbow connector ( 1), steel tube (1 m), banjo fitting ( ), cross connector ( 1) UC-1071- elbow elbow connector ( 1), steel tube (1 m), banjo fitting ( ), tee connector ( ) UC-1070- (for reservoir with straight outlet connector) UC-1071- (for reservoir with elbow outlet connector) Connection kit for pumps PE reservoir straight outlet TK-... 508-108 ( 1) 10-0W ( 1) TK-... 10-05W ( 1) reservoir elbow outlet WV-RO10x1VERZI (x1m) oil 10-07 ( ) oil Ø 8 10 pumps (PE--...) 5-516-101 ( ) (PE--...) (PE--...) (PE--...) Connectors and tubes for the connection reservoir / pump Order No. Copper washer... 508-108 Straight screw-in connector... 10-0W Elbow screw-in connector... 10-05W Steel tube Ø 8 10... WV-RO10x1VERZI Banjo fitting... 5-516-101 Tee connector... 10-07 Cross screw-in connector... 6-10-001 Straight connector* for tube OD 10.......... 10-10 Flange* for tube OD 10... 610-001 *) These parts are not included in the kits 10 1-106-EN
Connection pumps / nozzles or brushes Connectors and tubes for the connection pump / nozzles or brushes Connection pump / nozzle Order No. Steel tube Ø 0,7... WV-ROx0,7VERZI Connector (pump outlet)... 0-002 Double tapered sleeve (pump outlet)... 0-001 Connection pump / brush Steel tube Ø 0,7... WV-ROx0,7VERZI Connector (pump outlet)... 0-002 Double tapered sleeve (pump outlet)... 0-001 Hose, polyamide, Ø 2,5... TU-2.5x-RL Reinforcing socket (pump outlet).... RB.01 Tapered sleeve (pump outlet)... 0-611 Connector (pump outlet)... 0-612 *) Nozzles and brushes are delivered with their own fittings. Connection pumps / nozzles or brushes PE-... RB.01 ( 1) 0-611 ( 1) 0-612 ( 1) TU-2.5X-RL oil Ø8x1 0-001 ( 1) 0-002 ( 1) WV-ROX0.7VERZI NOZZLE AC-A-... Ø BRUSH UC-1066-... Ø 1-106-EN 11
Drip pan The drip pans are designed for the electromagnetic pump PE. They minimize the chance of any pollution in the case of leakage at the connections or during maintenance tasks. Technical data Drip pan SY.9581.1 Drip pan for 1 pump PE* Capacity.... 0,7 l Material... steel 1 Ø11 6 Order No.... SY.9581.1 *) The drip pan is delivered with screws and washers for the fixation of the pump 2 5 2 M8 26 110 0 180 0 = = 25 120,5 200 20 Technical data Drip pan for 2 pumps PE* 1 Ø11 Drip pan SY.9581.2 6 Capacity.... 1, l Material... steel Order No.... SY.9581.2 2 *) The drip pan is delivered with screws and washers for the fixation of the pumps 5 26 5 6 M8 200 20 270 = =,5 25 0 120 200 20 12 1-106-EN
Technical data Drip pan GR.271.7 Drip pan for 1 pump PE* Capacity.... 10, l Material... steel Order No.... GR.271.7 175 Ø11 110 105 *) The drip pan is delivered with screws and washers for the fixation of the pump 2 121 5 = = 25 2 M8 00 0 70 75 0 120 200 0,5 Technical data Drip pan GR.271.8 Drip pan for 2 pumps PE* Capacity.... 10, l Material... steel Order No.... GR.271.8 175 Ø11 110 105 *) The drip pan is delivered with screws and washers for the fixation of the pumps 2 76 5 6 5 = = 25 M8 00 0 70 0 120 75 200 0,5 1-106-EN 1
Notes 1 1-106-EN
1-106-EN
Order No.: 1-106-EN Subject to change without notice! (0/2009) Important product usage information All products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (101 mbars) by more than 0,5 bar at their maximum permissible temperature. Hazardous materials of any kind, especially the materials classified as hazardous by European Community Directive EC 67/58/EEC, Article 2, Par. 2, may only be used to fill SKF centralized lubrication systems and components and delivered and/or distributed with the same after consulting with and receiving written approval from SKF. Further brochures 1-9201-EN Transport of Lubricants in Centralized Lubrication Systems SKF Lubrication Systems France SAS Rue Robert Amy, B.P. 7010 90 Saumur cedex - France Tel. + (0)2 21 0 200 Fax + (0)2 21 0 22 www.skf.com/lubrication This brochure was presented by: SKF is a registered trademark of the SKF Group. SKF Group 2009 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.