INSTALLATION AND MAINTENANCE MANUAL

Similar documents
MAX-VH. Vertical Hollow Shaft Motors

NEMA Premium, High, and Standard Efficiency Vertical Hollow Shaft Pump Motors RELIABILITY MATTERS

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

Vertical Pump Motors

W22 Medium Voltage Motors TEFC - Severe Duty

56 mm sq. (2.20 inch sq.)

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Powerful + Efficient + Reliable

AC Induction Motors. Installation and operating instructions

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Severe Duty is Standard with WEG W22 motors

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

INSTALLATION, OPERATION AND CARE OF INTEGRAL HORSEPOWER INDUCTION MOTORS ( FRAMES) NAVY A-C MOTORS

56 mm sq inch sq.

Medium Voltage Motors and Soft Starters

NIDEC MOTOR CORPORATION

W22 NEMA Brake Motors - NEMA Premium

THE INNOVATIVE TEAM IN POWER TRANSMISSION

Installation and Operating Manual

Vertical HOLLOSHAFT High Thrust Motors - P Base, Single Phase Weather Protected Type I (WPI) Standard Efficient

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

NEMA Premium. Efficiency Motors SIE series EISA Product Catalogue

NIDEC MOTOR CORPORATION

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

Quick Engineering Facts Decimal Metric

Dimensions WxHxD [mm] Weight [kg]

Northern Pump A Division of McNally Industries, LLC

Fire Protection. FP-XA End Suction

Modifiable TITAN Horizontal Motors Accessories and Modifications

42 mm sq inch sq.

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

5. CLOSED SESSION: None

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

SECTION MOTOR REQUIREMENTS for HVAC

Ultra Series. Vertical Pump Motors HP. Durability, Reliability and Efficiency at the Heart of Industrial Operations

AE Installation Operation & Maintenance Instructions

Updated: October 2012

OPERATION & MAINTENANCE MANUAL

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

Operators Manual. Recirculating Chiller /06/08

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

QUANTUM PARALLEL SHAFT FAN DRIVE by Amarillo Gear Company

Installation and Maintenance Manual

Installation and Operating Manual

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

1/3-3 HP 1PH & 3PH TEFC 60 Hz NEMA AC Foot Mounted and Round Body C-Face Motors

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

PC-C5 DE RAN INDUSTRIAL & UTILITY GEAR DRIVES PAT.PEND. DE RAN GEAR, INC. Telephone A DON RANDOLPH COMPANY Fax

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

OTEC Transfer switch open transition

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

Contents. Identification

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

ECONOMIZER FAN. Receiving and Inspection

Installation, Maintenance and Operation Manual

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

PC-C5 DE RAN INDUSTRIAL & UTILITY GEAR DRIVES PAT.PEND. DE RAN GEAR, INC. Telephone A DON RANDOLPH COMPANY Fax

Centrifugal Constant Pressure Control

Operating Manual. High Performance Vacuum Pump Models and 15600

Installation and Operating Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Brushless DC Motor Systems FBL2 Series

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Series 2000 Inline Helical Gear Drives & Gear Motors

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

GE 8000-Line Motor Control Centers

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Our brand names are known as both Cantoni Motor (CC045A) and Elektrim (CC025A).

Centrifugal Constant Pressure Control

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

UD SERIES COMPRESSORS

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

: B3; B5; B14; B34; B35; V1

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

13,000 Watt Diesel Generator AGi13P E

Disconnect negative battery cable and remove coolant bottle cap.

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Torque Motors 3 W, 6 W, 10 W, 20 W

Series CC Condensate Units

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Linear Valve Electric Actuator

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Transcription:

VHSINSTALL.09 INSTALLATION AND MAINTENANCE MANUAL WORLDWIDE ELECTRIC VERTICAL HOLLOW SHAFT MOTORS WorldWide Electric Corporation Phone: 1-800-808-2131 Ext. 3 Fax: 1-800-711-1616fffffgff Website: www.worldwideelectric.net

VHSINSTALL.09 TABLE OF CONTENTS SECTION 1: General Introduction 1.1 Main Specifications Page 1 1.2 Operating Conditions Page 1 1.3 Motor Construction Features Page 2 1. Motor Dimensions Page 3 1.5 Coupling Dimensions Page 1.6 Bearing Types / Sizes and Max. Thrust Loads Page 5 SECTION 2: Operating Instructions 2.1 Inspection Before Operation Page 6 2.2 Filling With Oil Page 6 2.3 Electrical Connections Page 7 2. Lead Wire Information Page 8 2.5 Pre-Installation Test Page 9 SECTION 3: Installation Page 9 SECTION : Decibel Levels (Sound Levels) Page 10 SECTION 5: Warranty Policy Page 11 SECTION 6: On-Going Inspection and Maintenance Page 12 SECTION 7: Storage Page 12 SECTION 8: Shipping Dimensions Page 13 WorldWide Electric Corporation Phone: 1-800-808-2131 Ext. 3 Fax: 1-800-711-1616fffffgff Website: www.worldwideelectric.net

SECTION 1: General Introduction 1.1 Main Specification: Vertical hollow shaft motors are three-phase squirrel cage induction motors specially designed for driving deep-well turbine pumps. The motors have been designed according to NEMA standards with the following standard specifications: Power Supplied 60 Hz, 230/60V or 60V (Suitable for use at 50 Hz, 380V) Insulation Class: F Protection Grade: WPI (IP23) With Rodent Screens 1.2 Operating Conditions: Duty Type: Continuous (SI) Ambient Temp.: -10 C to 0 C Max. Altitude: Not more than 3300 F.A.S.L. (1000 M) above seal level (Contact WorldWide Electric for suitability at higher altitudes) Suitable For Operation In : Indoor / Outdoor Locations Installation & Maintenance Manual Page 1

1.3 Motor Construction Diagram: The following diagram shows the 280~0 (WPI IP23) Construction Features: (1) Top Cover (2) Coupling (3) Non-Reversing Ratchet () Ratchet Plate (5) Lifting Ring (6) Thrust Bearing (7) Cover (8) Oil Pump (9) Air Inlet Mesh (10) Seclusion Sleeve (11) Junction Box (12) Stand Pipe (13) Sight Gage Window (1) Oil Plug (15) Air Outlet Mesh (16) Ball Bearing (17) Lower Cover Mesh (18) Breather Bolt (Inside Of Top Cover Outside Of Ratchet) Installation & Maintenance Manual Page 2

1. Motor Dimensions: DIMENSIONS - INCHES FRAME P AA AB AC AF AG BE BV CD EO AJ AK 28TPH 286TPH 28TPA 286TPA 32TP 326TP 32TPH 326TPH 36TP 365TP 0TP 05TP 0TPA 05TPA TP 5TP TPA 5TPA BB MIN. BD MAX. 15.59 3NPT 13.15 10.29 5.02 31.30 0.95 12. 26.56.0 1.75 13.5 0.25 16.5 0.69 15.59 3NPT 13.15 10.29 5.02 31.30 0.95 12. 26.56.0 9.125 8.25 0.19 12.0 0. 17.32 3NPT 1.57 11.10 5.67 33.06 0.69 11.06 28.22.69 1.75 13.5 0.25 16.5 0.69 17.32 3NPT 1.57 11.10 5.67 33.06 0.69 11.06 28.22.69 9.125 8.25 0.19 12.0 0. 21.26 3NPT 19.06 15.59 5.91 36.00 0.69 1.00 31.16.69 1.75 13.5 0.25 16.5 0.69 21.26 3NPT 19.06 15.59 5.91 2.69 0.75 18.13 36.9 5.50 1.75 13.5 0.25 16.5 0.69 21.26 3NPT 19.06 15.59 5.91 2.69 0.75 18.13 36.9 5.50 1.75 13.5 0.25 20.0 0.69 23.62 3NPT 2.65 19.13 6.2 50.06 0.75 21.19.78 5.13 1.75 13.5 0.25 16.5 0.69 23.62 3NPT 2.65 19.13 6.2 50.06 0.75 21.19.78 5.13 1.75 13.5 0.25 20.0 0.69 BF Installation & Maintenance Manual Page 3

Installation & Maintenance Manual Page 1.5 Coupling Dimensions: DIMENSIONS - INCHES FRAME COUPLING NO. BX BY BZ XB XE XF SQ KEY (EW) 28/6TP WCK280-.75 WCK280-.875 WCK280-1 WCK280-1.0625 WCK280-1.1875 WCK280-1.25-.25 WCK280-1.25-.375 3/ 7/8 1 1-1/16 1-3/16 1-1- 10-32 10-32 10-32 10-32 1-1- 1-1- 2-9/16 2-9/16 2-9/16 2-9/16 2-9/16 2-9/16 2-9/16 2-2- 2-2- 2-2- 2-1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 3/16 3/16 32/6TP WCK320-1 WCK320-1.1875 WCK320-1.25-.375 WCK320-1.25-.25 WCK320-1.3125 WCK320-1.375 WCK320-1.5 1 1-3/16 1-1- 1-5/16 1-7/16 1-1/2 36/5TP WCK360-1 WCK360-1.1875 WCK360-1.25-.25 WCK360-1.25-.375 WCK360-1.3125 WCK360-1.375 WCK360-1.5 1 1-3/16 1-1- 1-5/16 1-7/16 1-1/2 0/5TP WCK00-1.1875 WCK00-1.25-.25 WCK00-1.25-.375 WCK00-1.375 WCK00-1.5 WCK00-1.5625 WCK00-1.6875 WCK00-1.8125 1-3/16 1-1- 1-7/16 1-1/2 1-9/16 1-11/16 1-13/16 /5TP WCK0-1.375 WCK0-1.5 WCK0-1.3125 WCK0-1.6875 WCK0-1.75 WCK0-1.9375 WCK0-2.1875 1-7/16 1-1/2 1-5/16 1-11/16 2-3/16 3-3-11/16 3-11/16 3-11/16 3-11/16 3-11/16 3-11/16 1/2 1/2

1.6 Bearing Types Sizes and Max Thrust Loads: MODEL NUMBER HP UPPER THRUST BEARING MAX. DOWN THRUST (LBS.) LOWER RADIAL BALL BEARING VHS25-18-2/-28TPA VHS25-18-2/-28TPH VHS30-18-2/-286TPA VHS30-18-2/-286TPH 25 30 7315B 370 6212Z VHS0-18-2/-32TP VSH0-18-2/-32TPH 0 VHS50-18-60-326TP VHS50-18-60-326TPH 50 7318B 5000 6213Z VHSN60-18-60-36TP 60 VHS75-18-60-365TP 75 VHS100-18-60-0TP VHS100-18-60-0TPA 100 7322B 8800 6317Z VHS125-18-60-05TP VHS125-18-60-05TPA 125 VHS150-18-60-TP VHS150-18-60-TPA 150 VHS200-18-60-5TP VHS200-18-60-5TPA 200 7328B 11600 6318Z VHS250-18-60-5TP VHS250-18-60-5TPA 250 Installation & Maintenance Manual Page 5

SECTION 2: Operating Instructions 2.1 Inspection Before Operation: The following steps should be followed carefully before operation: 1. Check nameplate data to make certain that the motor matches requirements. 2. Inspect the general condition of the motor, making certain there are no loose fasteners. Turn the motor in the correct direction of operation to ensure that the motor turns freely and that there was no damage during shipment. 3. Measure the insulation to ground with a megger capable of at least 500 megohms. (Reading should be at least 500 megohms.). Remove top cover and inspect non-reversing ratchet to ensure pins move freely and that it was not damaged during shipment. Lubricate pins if they are sticking at all. 2.2 Filling With Oil: 1. Remove the vent plug (flat head screw), located just outside of the nonreversing ratchet inside of the motor top cover, to prevent a vacuum inside the oil reservoir. 2. Remove the fill plug and fill with ISO VG 32 Turbine Oil to 1/2 up the sight glass. DO NOT OVERFILL!! 3. Replace the fill plug and the vent plug. Check for oil leaks.. For Transportation or storage, oil should be removed and the oil reservoir should be drained and cleaned prior to filling again. Installation & Maintenance Manual Page 6

2.3 Electrical Connections: 1. Connect leads according to the following diagrams: Sketch # 1 is for 60V motors (50 HP and above). Start connection is provided ONLY if using a part-wind starter. Wire as per run connection for across-the-line, soft start or for VFD starting. Sketch # 2 is for 230V / 60V motors (25 HP to 0 HP). 2. The motor must be grounded properly. A grounding terminal is located inside the terminal box. 3. Motors are fitted with 120VAC space heaters. Small gauge leads are in the main terminal box. Installation & Maintenance Manual Page 7

2. Lead Wire Information: HP VOLTAGE LEAD SIZE LEAD LENGTH (Inches) 25 230/60 10 AWG 8 30 230/60 8 AWG 8 0 230/60 6 AWG 8 50 60 10 AWG 8 60 60 10 AWG 8 75 60 8 AWG 8 100 60 6 AWG 8 125 60 AWG 8 150 60 AWG 8 200 60 2 AWG 8 250 60 1/0 AWG 8 Installation & Maintenance Manual Page 8

2.5 Pre-Installation Test: 1. Check Rotation When connected correctly, the rotation will be counterclockwise looking from the top of the motor. 2. Check Voltage Voltage at the motor leads should be measured to ensure that actual voltage matches the motor s rated voltage with little imbalance (less than 2.5% imbalance between phases). 3. Motor Protection It is necessary to provide over current or short circuit protection devices in the control panel or motor starter, which should be sized in accordance with the motor s full load current.. Test Running After visually inspecting, filling with oil and the electrical connections are complete, the motor can be test run. If the phase sequence is incorrect, the non-reversing ratchet will stop the motor from running in the wrong direction. Shut off power and switch any two line leads to reverse the motor rotation. Monitor the motor during this test run to make certain there is no noise, vibration or high current to indicate a potential problem. SECTION 3: Installation 1. Make sure that the motor specifications match that of the pump (i.e. RPM, HP, etc ) 2. During the course of installation, the motor should never be in any position other than vertical. If the motor is tipped more than 10 from vertical, oil will spill from the reservoir. 3. The motor base must be structurally sound to prevent vibration or misalignment. If significant vibration is present following the installation, check the base and alignment for potential problems and contact your installation company. Installation & Maintenance Manual Page 9

SECTION : Decibel Levels (Sound Levels) Decibel levels (sound levels) should be measured on motor start-up, after thirty (30) days and after six (6) months. Decibel levels are also an indication as to the vibration levels of an electric motor. A decibel chart has been provided here for your convenience. If the measured motor decibel levels exceed the listedlevels by more than ten percent (10%), please consult the motor manufacturer and/or your motor repair center. MODEL NUMBER VHS25-18-2/-28TPA VHS25-18-2/-28TPH VHS30-18-2/-286TPA VHS30-18-2/-286TPH VHS0-18-2/-32TP VSH0-18-2/-32TPH VHS50-18-60-326TP VHS50-18-60-326TPH HP 25 30 0 50 DECIBEL LEVEL 80 db VHSN60-18-60-36TP 60 VHS75-18-60-365TP 75 VHS100-18-60-0TP VHS100-18-60-0TPA 100 85 db VHS125-18-60-05TP VHS125-18-60-05TPA VHS150-18-60-TP VHS150-18-60-TPA VHS200-18-60-5TP VHS200-18-60-5TPA VHS250-18-60-5TP VHS250-18-60-5TPA 125 150 200 250 90 db Installation & Maintenance Manual Page 10

SECTION 5: Warranty Policy 1. Warranty Length The warranty length for WorldWide Electric Vertical Hollow Shaft Motors shall be one year from the date of sale (invoice). Discrepancies and allowances on length of warranty or warranty decisions to be made by WorldWide Electric Corporation. 2. Where To Warranty / By Whom WorldWide Electric Motors may be warranted and serviced by any EASA (Electrical Apparatus Service Association) Shop / Member in and outside of the United States. non-easa Shops may be considered for warranty, but must be approved by WorldWide Electric Corporation in advance. 3. Procedure All Motors must be inspected by a UL Certified EASA or other approved motor shop for determination of cause of failure. If the failure is determined to be warrantable, WorldWide Electric shall either repair or replace the motor. The service station must contact WorldWide Electric Corporation with an estimate of repair. The warranty repair must be approved before the repair may be performed. Installation & Maintenance Manual Page 11

SECTION 6: On-Going Inspection and Maintenance 1. In the course of operation, current and voltage should be measured from time to time to ensure it matches the motor specifications. Whenever abnormal noise occurs during operation, immediate shut-down and inspection is required. 2. The non-reversing ratchet should be checked yearly to ensure no build-up of dirt or debris has occurred that could prevent its proper operation. This should be checked when the oil is being changed. 3. The oil level should be checked through the oil sight gauge periodically to ensure no oil is being lost. The level should be just at or below the center-line of the gauge with a motor at standstill. THE LEVEL WILL DROP BELOW THE CENTER WHEN THE MOTOR IS IN OPERATION. THIS DOES NOT INDICATE A PROBLEM, IT INDICATES THE OIL PUMP IS WORKING PROPERLY. SECTION 7: Storage 1. When storing the motor(s) for an extended period of time (6 months or more), the following steps should be taken: A. Clean the exterior and interior (inside of top cover) of the motor thoroughly. B. Cover the air inlets and outlets (mesh) of the motor to prevent the entrance of dust. 2. The motor should be stored in a clean and dry environment. The storage are should be free from vibration and be low in humidity. The temperature of the storage area should be between 0 F and 80 F. If the motor is to be stored outdoor or even installed outdoors without running for a period of one week or more, please energize the space heaters to prevent condensation inside the motor. Installation & Maintenance Manual Page 12

SECTION 8: Shipping Crate Dimensions / Weights HP FRAME SIZE NET WEIGHT (Lbs.) 1800 RPM GROSS WEIGHT (Lbs.) L x W x H (Inches) 25 30 0 50 28TPA 96 595 2.8 x 2.8 x 37.8 28TPH 515 615 2.8 x 2.8 x 37.8 286TPA 507 606 2.8 x 2.8 x 37.8 286TPH 526 626 2.8 x 2.8 x 37.8 32TP 656 773 26.2 x 26.2 x 39. 32TPH 639 756 26.2 x 26.2 x 39. 326TP 667 78 26.2 x 26.2 x 39. 326TPH 652 769 26.2 x 26.2 x 39. 60 36TP 960 108 26.8 x 33.7 x.3 75 365TP 996 1119 26.8 x 33.7 x.3 100 0TP 1238 1363 26.8 x 33.7 x 50 125 05TP 1278 103 26.8 x 33.7 x 50 150 200 TP 1738 189 29.9 x 0.9 x 57.9 TPA 1762 1919 29.9 x 0.9 x 57.9 5TP 1872 2029 29.9 x 0.9 x 57.9 5TPA 1896 2053 29.9 x 0.9 x 57.9 250 5TPA 2053 2209 58.3 x 50. x 58.3 Installation & Maintenance Manual Page 13