Medium Voltage Outdoor Apparatus Portfolio 2009

Similar documents
AutoLink Frequently Asked Questions

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Padmount Solid Dielectric Switchgear Catalog

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Disconnect & ByPass Switches

solutions RUS accepted

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Outdoor Padmount Switching Products

GROUP D. Switch & Protective device.

Cobra-S. Catalog Cobra-S

Type ICX Outdoor open type cutout

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

ABB Automation & Power World: April 18-21, 2011 WPO MV outdoor products for smart grid demands. ABB Inc. April 19, 2011 Slide 1

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Air-insulated switchgear UniGear type ZS1

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Solid Dielectric, Single Phase Recloser

Solid Dielectric, Single Phase Reclosers

Solid Dielectric, Three Phase Reclosers CATALOG VS11

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

David Park, EPMV ABB South Africa / Africa Channel Partner event, 2016 ABB Africa Channel Partner event Medium Voltage Apparatus

Medium Voltage Products Table Of Contents

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Three-Phase Pole Mounted Recloser

FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation

Medium Voltage Products Table Of Contents

ABB Medium Voltage Products. ABB Group June 15, 2015 Slide 1

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

SWITCHGEAR DIVISION PRODUCT PROFILES

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

C1000 Series Automatic Cap Bank

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Typical Specification

OHB Outdoor sulphur Hexafluoride circuit-breaker

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

TECHNOLOGY REVIEW. NPS Modular outdoor switch-disconnectors

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

Typical installations of the NPS modular outdoor switch disconnector

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

S&C Loadbuster Disconnects

Switchgear and Distribution Systems for Engineers and Technicians

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Horizontal Circuit Switchers

Metal Clad VCBs ~ Mk1

Overhead Switching Devices

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

EMPAC Metal enclosed capacitor bank for wind applications

Electronic Resettable Sectionalizer

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

Substation Concepts for the Future

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

EE 741 Over-voltage and Overcurrent. Spring 2014

RUS accepted Catalog O-vst18

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

PRODUCT SELECTION GUIDE

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

CATALOG. Elastimold Reclosers, switches and switchgear

ZX-Family Gas-insulated medium voltage switchgear

Q pole Pole Mounted Capacitor System

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Medium Voltage Metal-Enclosed Switches

Horizontal Circuit Switchers

Medium Voltage Metal-Enclosed Switches

NXPLUS C Single busbar. Maintenance-free for lifetime

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

100 / 110 DRYWELL FUSE SPECIFICATION

Transmission Switching

OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

When power interruptions happen.

CATALOG. Joslyn Hi-Voltage Overhead reclosers & switches

Power IT Air Insulated Cubicle Uniswitch

10DD 10DD-1. Section CAUTION:

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Advance 27 ANSI 27 kv switchgear

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

ELASTIMOLD MOLDED VACUUM SWITCHGEAR

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

Pretest Module 29 High Voltage Unit 1

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

NPS modular outdoor switch-disconnectors

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Product Group Brochure. PS Range Capacitor Vacuum Switches

Transcription:

PPMV, April/May 2009 Medium Voltage Outdoor Apparatus Portfolio 2009 May 5, 2009 Slide 1

Summary Reclosers Outdoor dead tank vacuum circuit breakers Outdoor live tank circuit breakers Pole mounted circuit breakers SF6 insulated load break switches Single phase electronic sectionalizers Three phase air insulated switches Fuse cutouts Single phase air insulated switches Padmount Switches May 5, 2009 Slide 2

Reclosers OVR-3 & PCD Control Factory: Lake Mary, FL, U.S. No electronics in HV compartment HCEP insulation material Encapsulated vacuum interrupters and sensors Magnetic actuator per phase Single-phase tripping option Superior life rated for 10,000 operations Max Design Voltage, KV 15.5 27 38 Current, A 630 / 800 / 1000 630 / 800 / 1000 630 / 800 / 1250 BIL, kv 110/ 125 Interrupting Current, ka 12 125 12 170 16 May 5, 2009 Slide 3

Reclosers OVR-3SP & PCD Control Factory: Lake Mary, FL, U.S. Utilizes similar technology as OVR-3 Individual pole design allows for flexible mounting arrangements Phase-over-phase / Wrap-around / Cross arm Substation replacement of small profile devices Seamless transition of replacing 3 hydraulic units One PCD control for operating all three recloser poles Available in rack mount for substation mounting or standard cabinets Max Design Voltage, KV 15.5 27 38 Current, A 630 / 800 / 1000 630 / 800 / 1000 630 / 800 / 1250 BIL, kv 110/125 12 125 12 170 16 Interrupting Current, ka May 5, 2009 Slide 4

Reclosers OVR-1 & ICD Control Factory: Lake Mary, FL, U.S. Similar pole design as OVR-3 ICD Control - Fully integrated magnetic actuator-based control including energy storage capacitors Fault current indication self-diagnostics of power supply, memory elements and microprocessors All basic recloser functions AC powered electronic control eliminates need for maintaining batteries Max Design Voltage, KV Current, A BIL, kv Interrupting Current, ka 15.5 800 110/125 10 27 800 125 10 May 5, 2009 Slide 5

Outdoor dead tank vacuum circuit breakers Factory: Lake Mary, FL, U.S. R-MAG Breaker 15kV & 27kV Magnetic actuator No maintenance on operating mechanism Five year warranty R-MAG Type V Breaker 38kV Two bottle per phase design Spring charged mechanism All breakers vacuum interruption & rated for back to back capacitor switching R-MAG 15 Voltage, kv Current, A 1200 / 2000 / 3000 / 3700 Interrupting, ka R-MAG 27 1200 / 2000 12-25 Type V 38 1200 / 2000 25-40 BIL 12-25 110 125-150 150-200 Type V May 5, 2009 Slide 6

Outdoor live tank circuit breakers Factory:, Nashik India OHB VBF Telescopic structure to meet the statutory requirement of minimum height from ground level Superior life: Tested for 10,000 operations Re-strike free: Tested for C2 class Capacitor switching duty Suitable for operating in temperatures ranging from -40 deg C to + 45 deg C. SDB OVB- SDB OHB OVB- VBF Voltage, kv Current, A Interrupting, ka (3 sec) BIL 15 2000 25 110 24 / 36 / 40.5 2500 31.5 200 36 / 40.5 2000 / 2500 25 / 31.5 175 /195 May 5, 2009 Slide 7

Pole mounted circuit breaker Factory:, Xiamen China Encapsulated vacuum interrupters with HCEP insulation material Breaking current in vacuum interrupters environmentally Spring mechanism with auti-pumping function needs low operating power and easily being upgraded Superior life Rated for 10,000 operations Combined the functions of protection, monitoring and control Different optional DA schemes PCD control or REF615 Rated Voltage, kv Current, A BIL, kv Interrupting Current, ka Rated Voltage, kv 12 630 75/85 20 12 May 5, 2009 Slide 8

SF6 load breaking switches Factory: Xiamen China NXB NXBD NXA DTU Sectos Complete sealed stainless steel tank 2-position (ON-OFF) or 3-position (ON OFF - EARTH) Reliable spiral spring operation mechanism with light reflecting and clear position indicator Stable gas density switch and temperature compensated gauge Distribution automation solution with remote communication and current and voltage sensing availability Mechanical manual locking device or low gas locking device Easily upgraded from manual to motor operation Sectos Max Design Voltage, KV Current, A BIL, kv Short time withstand current NXB 24 630 125/145 20KA / 3s NXBD 24 630 125/145 20KA / 3s NXA 36 630 170/195 12.5KA / 3s May 5, 2009 Slide 9

Electronic sectionalizer Factory: Buenos Aires, Argentina Autolink Improves reliability on overhead feeders by sectionalizing feeder in conjunction with upstream recloser or breaker Customer settable current and counts Settable actuating current Manually resettable after operation Inrush detection feature Fits into standard fused cutout bodies Max Design Voltage, KV Number of counts Current settings, A BIL, kv 15-33 1-4 6 to 215 95-170 May 5, 2009 Slide 10

3 Phase air insulated switches R, S, U Factory: Moorebank Australia U Series Side break operating contacts Mounting options: Pole top & mid pole Disconnector or load break interrupter options Vertical or rotary operating handle S Series Side break operating contacts Mounting options: Pole top, mid pole, vertical & horizontal Disconnector or load break interrupter options Porcelain or polymeric insulator options R Series Vertical break operating contacts Mounting options: Pole top, mid pole, vertical & horizontal Disconnector or load break interrupter options Porcelain or polymeric insulator options Voltage, kv Current, A Series U 12-36 630 20 Short Time Withstand, ka BIL 150 & 200 Series R 12-36 800-2000 up to 31.5 up to 225 Series S 12-36 630 20 150 & 200 May 5, 2009 Slide 11

3 Phase air insulated switches NPS Factory: Vaasa Finland Vertical breaking contacts Gang operated manual or motor. Horizontal or vertical mounting Wide range of optional accessories - fuses, earthing switches, CT s Cycloaliphatic epoxy insulators (CEP) on NPS24B Standard silicone rubber insulators on NPS24A..36A (Isoelectric) used Load breaking and making capacity Whips for 25A and new design for 50A K4/K5 air breaking chambers for 250 and 630A Unique K5 chamber with also 8..12,5 ka making capacity Voltage, kv Current, A Short Time Withstand, ka BIL NPS24B 12-24(25,8) 630 16 125 NPS24A 12-24(25,8) 630 20 125 and 150 NPS36A 24-36 630 21 170 and 200 May 5, 2009 Slide 12

Fused cutouts Factory: Greensboro NC, U.S / Moorebank Australia ICX LBU ICX cutouts: interchangeable fuse holder NCX cutouts: non-interchangeable fuse holder LBU-II loadbreak cutouts: non-interchangeable fuseholder EU: Enclosed fuse holder Series V: non-interchangeable fuse holder, IEC 129 / AS 1306 All fused cutouts are available with silicone, polymer concrete, or porcelain insulators NCX V Type Standard Voltage (kv) Current (A) Interrupting Current (ka) BIL ICX ANSI 7.8,15, 27, 38 100-300 8, 10, 12, 16, 40 110, 125, 150, 170 NCX ANSI 7.8,15, 27, 38 100-300 8, 10, 12, 16, 40 110, 125, 150, 170, 180 LBU-II ANSI 7.8, 15, 27, 20, 34.5 100-300 8, 10, 12, 16, 20, 40 110, 125, 150, 170, 180 Series V IEC 12 36 100 (6-8) - ( 2-4) 125, 150, 170 May 5, 2009 Slide 13

Single-phase disconnectors Factory: Greensboro NC, U.S / Moorebank Australia SID LSID DCD SLS Visible disconnect for maintenance of line equipment Support insulator: porcelain polymer concrete or silicone Type Standard Voltage (kv) Current (A) Momentary Rating (ka) BIL Number of Insulators SID/LSID ANSI 15-38 600 / 900 40 110-170 1 SLS IEC 12-36 630 / 800 16 / 25 125-170 1 DCD ANSI 15-38 600 / 900 40 110-150 2 SLD IEC 12-36 630 / 800 16 / 25 125-200 2 May 5, 2009 Slide 14

Single phase by-pass switch Factory: Greensboro NC, U.S / Moorebank Australia Normal operating mode Bypassing or disconnecting reclosers or regulators; Allows quick system reconfiguration or maintenance without interrupting service Support insulators: porcelain or silicone Mounting configurations: vertical, underhung, pole mount, or crossarm Blade stop prevents switch from closing under high momentary current. Holds the blade in the 90º or 160º position Type Standard Voltage (kv) Current (A) Momentary Rating (ka) BIL RBD ANSI 15, 27, 38 600 / 900 40 110, 125, 150 By-pass mode SLDT IEC 12-36 630 25 150, 200 May 5, 2009 Slide 15

Single-phase by-pass disconnector Factory: Moorebank Australia / Greensboro NC, U.S. FBS (Fused By-pass Switch) Used to disconnect and isolate circuit reclosers while performing repair and maintenance functions Support insulator: silicone The standard arc chute allows opening of the fuseholder under load without the need for a portable loadbreak tool SLSB Single-phase by-pass disconnector Integrated fused cutout for fault protection Type Standard Voltage (kv) Current (A) Momen-tary Rating (ka) BIL FBS ANSI 15 200 40 110 SLSB IEC 12-24 630 25 125, 150 May 5, 2009 Slide 16

Inline tension single-phase disconnect switch Factory: Greensboro, NC U.S. ITD Used for manual switching of de-energized or parallel circuits of overhead distribution lines Installed directly in the distribution line Support insulator: silicone Blade stop: prevents switch from closing under high momentary current. Holds the blade in the 90 or 160 position Type Standard Voltage (kv) Current (A) Momentary Rating (ka) BIL ITD ANSI 27, 38 600/900 40 150, 200 May 5, 2009 Slide 17

Padmount switches Factory: Lake Mary, FL U.S. Live front (MES) and dead front (MDS) switches Used to isolate an underground line or allow reconfiguration of the system to feed from other directions Live front - Energized parts are exposed when doors are open Dead front - Energized parts are completely enclosed within a grounded steel compartment for increased personnel safety, electrical isolation and protection from contamination Utilizes ABB NAL switch Various switch / fuse configurations available Max Voltage, KV Current, A Load Interrupting, A Momentary and fault closing, ka 15-27 600 600 40 May 5, 2009 Slide 18

Padmount switches Factory: Lake Mary, FL U.S. ME fused sectionalizing enclosures Designed for 200 A circuits to protect and sectionalize a system 15 and 25 kv dead-front with multiple mounting options Power fusing Load break or non-load break S&C and Cutler Hammer compatible Current limit fusing Cooper and Hi-TECH Bushing wells for 200 A standard with 600 A source bushings optional Single and three phase configurations Radial or loop feed with one, two or three fused loads Max Design Voltage, KV Current, A 15 27 200 May 5, 2009 Slide 19

May 5, 2009 Slide 20