The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

Similar documents
The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

Igniter, BMS & Valve Parts Directory Contact Us Toll Free:

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

Start-up Instructions

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Page 1 sur 5. Diagnostic Trouble Code Diagnosis Charts. Sportage [AL] > 2000 > Engine > 2.0 DOHC

GEMINI GAS CONTROL PRODUCT INFORMATION

MODEL G300 BRAKE BLEEDER

ARGONITE Fire Protection Systems

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Stock Pot Range. Gas & Electric Models. Parts List. GAS Models: ELECTRIC Models: G20-SP G20-SPH E20-SP E20-SPH. G20 shown

Water Valve Shutoff. WVS Water Valve Shutoff

Design and Application Details

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

Stock Pot Range. models (Electric) E20-SP, E20-SPC (Gas) G20-SP, G20-SPH.

Design and Application Details

Model 5000 Level Controller

Applies to: Models F, B, FE, and BE with spark pilot

Eclipse AutoTite Automatic Gas Shut-Off Valves

Design and Application Details

Heating and Gas Installations - December 2014

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

G76x Direct Spark Ignition Controls

E Series CE Approved Intermittent Pilot Ignition Control

Seismic Sensor Accessories SA, SV & ST 6000 Series

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

47 SERIES GAS FRYERS PARTS LIST

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Martin Tornado Retrofit Valve

FUEL KITS P/N & 526-4

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

Gas Convection Ovens UP TO

Eclipse AutoTite Automatic Gas Shut-Off Valves

HIGH QUALITY GAS PRODUCTS SINCE 1957

Hydro-Flow Model 2200 Installation and Operation Guide B

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

36H Gas Control Product Information

PT-M90 Automatic Full-Sequence Modulation Gas Control System

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

IGNITION FLAME SAFETY CONTROLLER

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

H280-series Valve Overheat / Relocation Kit Instructions: Standard Oven. Instructions for Applying Kit #

PARTS LIST GAS TILTING SKILLETS MODELS: GLTS-30 GLTS-40

High Tension Spark Igniter (HTSI)

B21 Series BASOTROL Gas Valve

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

SECTION 6 PARTS LIST

BG1600M Intermittent Pilot Ignition Control

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Nordson Airless Nozzle Tester

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

SCC Inc. FLMTR Series. Installation Instructions Document No. LV February 21, KT-BMK-PLC Gas Flow Meter Kits for Flow Totalization

Tuffy Liquid Level Switches

type 630r relief Valve

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Operating Manual. Safety/Process Flare Pilot

Voltmaster Centrifugal Trash Pumps

6 Gauge Box Set IS0332

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Type 289P Pilot-Operated Relief Valve

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

2.0 Burner Operating Parameters and Requirements

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

Weld Preheating and Stress Relieving. Process. Induction Heating. Input Power VAC, 3-Phase, 60 Hz

Type MR108 Direct-Operated Backpressure Regulators

Bourdon Tube Pressure Switches

Type MR108 Direct-Operated Backpressure Regulators

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

PF 3100 ION PILOT CARD PRO.FIRE

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

TFL Gas Log Lighter (TFLGLL)

RED DRAGON ELECTRONIC PROPANE FLARE

18SP653 EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation

Type 289P Pilot-Operated Relief Valve

Installation Manual. ACL3200 Flare Stack / Incinerator Ignition Systems

Built-In Temperature Controller

LVDT/HC PILOT BURNER. External raw gas pilot burner

Spring-Loaded RTD/Thermowell Assemblies with Connection Heads (GP03, XP03, XP05)

Level Measurement Point level measurement - RF Capacitance switches

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors

Signet 2517 Brass Paddlewheel Flow Sensor * *

TECHNICAL MANUAL WENDY'S RANGE MODEL: C0300HT AND C0301 HT

Transcription:

OPERATIONS MANUAL The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor The CSA approved alternative ignition system delivering safety, reliability and versatility.

KEY FEATURES Unique 316 SS Pilot Head Assembly. Hot Electronic Ignition. Retractable assembly easily installs through a standard 2 or 3 nipple. Easily removed for inspection. High temperature ignition lead is fully protected with 316 SS conduit. Local or remote spark ignition. Low fuel gas consumption. Easily incorporated system flame status reporting for burner management. TECHNICAL SPECIFICATIONS Electrical Environment Power Supply Current Draw Ignition Fuel Gas Fuel Type Working Pressure Maximum Test Pressure Fuel Consumption Physical Operating Temperature Materials and Parts Supply Port Mounting Insertion Length CSA C22.2 Class 1 Div. 2 Groups B, C and D Hazardous Locations 12-30 VDC 40mA (ignition) 0mA (normal operation) 25 KV Natural Gas or Propane 1 Psi (Natural Gas), 0.5 Psi (Propane) 25 Psi 8 SCFH, 22000 BTU/Hr. -40 to +40 C Aluminum, SS 3/8 Tubing 2 or 3 NPT Nipple 12 through 72

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor OPERATIONS MANUAL Combustex recommends that this manual be read thoroughly before attempting installation or operation of the Pilot Pro 500. SAFETY FIRST. Operational Description Parts List & Diagram Installation Guidelines Operating Procedure Maintenance Requirements p 1 p 2 p 3 p 8 p 8 The Pilot Pro 500 Electronic Ignition Assembly provides the three primary functions required to establish and maintain pilot flames reliably and safely: Pilot flame ignition Thermocouple flame sensing Contained and non-intrusive lighting This unit is normally installed with a Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. The Pilot Pro Series igniters have been designed and built around the features of the BMS-2000. All Pilot Pro 500 units are function tested on a BMS- 2000 sequencer prior to shipment from the factory. A clean natural gas or propane supply is required on the supply port. When the pilot fuel gas valve is opened supplying the igniter with fuel gas, an ignition signal is sent to the electronic ignition assembly from a controller for a 15 second (max.) period. When the pilot gas ignites, a thermocouple provides a signal for flame detection. This signal should be used to establish a threshold to indicate flame or flame failure.

2 of 9 DETAIL C 15 12 11A 11B 16 21 8 1 11C 14 11D 5 6 Item Qty. Description Part No. 1 1 Type K Thermocouple 1008 2 1 Flange - Instrument Connection 1009 19 13 2 18 17 3 1 Flange - 2 NPT Female 1010 3 1 Flange - 3 NPT Female (optional) 1011 4 1 Flange Gasket 1013 5 1 1/2 Aluminum Seal 1014 4 6 2 1/2 x 2 Aluminum Nipple 1015 7 1 Ignition Lead Wire Assembly 2005 3 8 3 Gas Pipe - 3/8 (SS Pipe) 1023 9 1 Conduit - 3/8 (SS Pipe) 1023 10 1 Slide Protector 2002 9 11 1 Pilot Head Assembly (includes 11A through 11D) 2003 11A 1 Pilot Head 500 1026 11B 1 #8-32 x 1/4 Thermocouple Set Screw - SS 1299 20 11C 1 Deflector Plate 1027 11D 1 #10-24 x 3/8 Deflector Plate Set Screw - SS 1299 12 1 Spark Plug 1029 13 1 3/8 Elbow Tube Fitting 1030 14 1 Cl. 1, Div. I & II Enclosure Base 1031 15 1 Enclosure Cap 1032 10 16 1 Ignition Module 2007 17 4 5/16 Lock Washer - Zinc 1300 18 4 5/16-18 x 1 Bolt - Zinc 1301 19 4 5/16-18 Wing Nut - Zinc 1302 20 1 5/8 ID External Snap Ring 1025 21 2 10-24 x 5/16 Screw 1058 DETAIL C 7

3 of 9 MOUNTING The mounting location chosen on the vessel should be determined by Operator accessibility and visibility Entry into the fire tube Ease of tubing installation The recommended mounting configurations of the Pilot Pro 500 are Side Angle Mount - (see drawing p. 4). Parallel Mount - Front side of the fire tube directly below the main burner with the tip of the pilot vertically aligned with the tip of the main burner. (See drawing p. 5) Side angle entry has the advantage of a shorter pilot assembly, making maintenance easier and tending toward a more stable flame in the fire tube. However, the welding procedure in this configuration is more difficult. The Pilot Pro 500 is stocked and available in standard lengths of 12, 18, 24, 36, 48 60 and 72. Custom lengths can be manufactured by special order. A 2 or 3 nipple welded squarely to the fire tube end plate or side is required for mounting with the length adjusted to match standard A dimensions (see drawings) wherever possible. Where the igniter length exceeds 48, it should be supported at about midpoint within the fire tube with either a J bracket or cross support. When threading the Pilot Pro 500 body onto the mounting nipple, ensure that an approved aluminum thread lubricant is used. Rotate the body until it sits snug against the supply port on the bottom.

4 of 9 Combustex Pilot Pro 500 Side Angle Mount Pilot Burner Installation Top View Side View A A Notes A dimension (length from outside end of 2 or 3 nipple to tip of main fuel nozzle) required when ordering prefabricated units. Size to standard lengths where possible. Installed 2 nipples must be sch. 40. End of Pilot Pro 500 igniter unit should be approximately 1.5 behind main burner.

5 of 9 Combustex Pilot Pro 500 Parallel Mount Pilot Burner Installation Back View Side View A Notes A dimension (length from outside end of 2 or 3 nipple to tip of main fuel nozzle) required when ordering prefabricated units. Size to standard lengths where possible. Installed 2 nipples must be sch. 40. End of Pilot Pro 500 igniter unit should be approximately 1.5 behind main burner.

6 of 9 PIPING The Pilot Pro 500 is normally installed with a Combustex BMS-2000 Series Burner Management System or other similar type of sequencing apparatus. P&ID drawings for the igniter unit are included in the BMS-2000 literature. Installation as per these Combustex-approved drawings is recommended. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for proper piping arrangements. Where there may be a concern that the main fuel gas control valve could leak, it is recommended that the double block and bleed piping arrangement be installed. A clean, steady gas supply is required for optimum reliable operation. It is recommended that a filtered instrument regulator be installed upstream of the unit directly at the point where the instrument gas is tapped off of the main fuel gas line. The Pilot Pro 500 is rated for sour gas service, with higher maintenance requirements expected when operated on this type of gas. Where only sour or extreme wet gas is available for fuel, it may be advantageous to operate the pilot and instruments from an auxiliary propane source. For installations where only wet fuel gas is available, it is recommended that a coalescing filter be installed on the pilot gas at a point before the gas leaves the heated building, or in cases where no building exists, directly after the filter regulator. Where concerns of freezing exist, keep the lines as short as possible and slope them back towards a drip pot located in a heated enclosure. Insulating the pilot supply and output lines along with heat tracing where possible will help in solving freeze-up problems. On new installations, freeze-up problems can be minimized if the supply line can be located under the vessel insulation. 3/8 cadmium plated or stainless steel tubing, supported adequately, is recommended. Ensure that when installing the tubing, adequate flexibility is provided, allowing for removal and insertion of the unit during maintenance. Use an approved aluminum thread lubricant on the fittings inserted into the supply and output ports. Avoid stresses created by improperly installed tubing.

7 of 9 Wiring The Pilot Pro 500 is normally installed with a Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for proper wiring schematics. STEADY STATE INPUT JUMPER BMS CONFIGURATION AUX STEADY IGN. OUTPUT MUST BE SET TO YES GND -24 +24 R1 R2 IGN TC+ TC- TC+ TC- BMS-2000 TS7 or TS9* 1 2 3 4 IGNITOR - OUTPUT + 5 6 7 8 CONNECT TO CORRESPONDING T/C INPUTS (BMS-2000; TS6) NOTE * TS7 - SINGLE BURNER ONLY * TS7 & TS9 - DUAL BURNER The Pilot Pro 500 is CSA approved for Class 1, Div. 2 Group ABC or D hazardous locations. Interconnecting wiring between the pilot / igniter assembly and Combustex BMS-2000 Series Burner Management System must be minimum (1) 2 conductor pair and (1) 3 conductor #18 shielded Belden with shields tied to ground at the BMS-2000 end only. An additional #14 XL Green conductor is used to ensure proper grounding between the BMS-2000 and igniter module, and is run with the Belden cables. The preferred location for flex entry is the bottom of the Pilot Pro 500, between the pilot / igniter assembly and the rigid conduit leading from the BMS-2000. It is highly recommended that a length of seal tight flex long enough to extract the pilot assembly is used. This will enable maintenance personnel to remove the assembly without having to disconnect the wiring.

8 of 9 The Pilot Pro 500 is controlled by the Combustex BMS-2000 Series Burner Management System or similar type of sequencing apparatus. Operating instructions and safety information are included in the BMS-2000 literature. If the unit is to be installed with a controller other than the BMS-2000, consult the manufacturer s literature for operating information. Note: It is the responsibility of the operator or controller to ensure that the fire tube has had enough time to be purged of combustible mixtures prior to attempting to relight the unit. Due to the possibility of a control valve leak, the main fuel gas valve should be closed for a period of time to ensure air purging of the fire tube. The main gas valve should not be reopened until a pilot flame has been confirmed. For trouble free operation, a maintenance and inspection schedule should be set up. Every 3 months, test the ignition and shutoff features by manually closing the fuel gas valves to simulate a flame failure condition. The unit should lockout the pilot and main gas within two minutes. Once a year remove the assembly and inspect the condition of the thermocouple, ignition wire an spark plug for excessive corrosion and carbon buildup. Ensure that the orifices in the pilot tip are clear of any particulate as well. All seams and seals around the flame arrester and igniter body should be free of cracks or holes that might allow a flame to escape. If any of these conditions are found, the element should be cleaned or replaced prior to returning to service. Inspect, clean and replace all components as required. Reassemble the unit and test after inspection and maintenance. Combustex offers a service kit for the Pilot Pro 500 complete with 1 year recommended spare parts. This package contains the following items: # 1 - Type K Thermocouple (P/N 1008) # 7 - Ignition Lead Wire Assembly (P/N 2005) # 10 - Slide Protector (P/N 2002) # 11 - Pilot Head Assembly (P/N 2003)* # 12 - Spark Plug (P/N 1029) # 16 - Ignition Module (P/N 2007) * Refer to assembly drawing p. 2

9 of 9 The Canalta, Combustex Burner Ignition & Control Systems and Pilot Pro names and logos are trademarks of Canalta Controls Ltd. All other trademarks are the property of their respective owners. Due to Canalta s commitment to quality and innovation, all product designs, specifications and information materials, including the contents of this publication, are subject to change without notice. Responsibility for the proper selection, maintenance and use of any product remains with the customer. SAFETY FIRST. 2011-2015 Canalta Controls Ltd. All rights reserved. Unauthorized reproduction in whole or in part is prohibited.