RAFTERS. Single and Continuous Spans

Similar documents
LINTELS WITH TG. Single Spans. Lintels Supporting Truncated Girder Truss INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2

INDEX OF W.T.I. BEAMS

Span guide for residential framing. September Fully supported by

Strutting Beams Supporting Underpurlins Only

01 CONTENTS. e-beam. e-beam. Technical Information 03

Product grading of all members is compliant with AS1720: Timber Structures.

SPAN TABLES SPAN TABLES

Prolam LVL 15 Design Guide. Register Free for our Beam Calculator

Meypine. Handy Span Guide

JD3 rated for greater connection strength. makes it easy to spot in the warehouse or on site

Rosboro TM. Next-Generation Glulam. n Architectural Appearance. n Full Framing-Width Stock. Glulam. n I-Joist and Conventional.

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

SmartFrame Product Warranty*

SmartLam GL18 Design Guide

Purlins and Girts. A division of Canam Group

SPAN TABLES FOR RESIDENTIAL BUILDING NOW AVAILABLE H2-S TREATED TO PROTECT AGAINST TERMITES

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

SmartLVL 18 Design Guide

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension

DESIGN CHART # 1: Lamit Basic S.I.P Properties

Rosboro Manufactured Timber. Preferred lengths Dry stable timber Full-Framing Width

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

Design principles and Assumptions

Requirements for Use of Allowable Load Tables

Swifts XRF extra heavy duty return flange straight lengths

WESTERN SPECIFIER GUIDE. for products manufactured in White City, Oregon

Scope : Steel Beam Design. Pinned-Pinned Bm Wt. Added to Loads LL & ST Act Together # 1 # 2 # 3 # 4 # 5 # 6 # Start Location End Location

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

SmartLam GL 17 Design Guide

LP SolidStart Engineered Wood Products

PLANK-AND-BEAM FRAMING FOR RESIDENTIAL BUILDINGS

BOISE GLULAM Beam and Column Specifier Guide

GENERAL INFORMATION FEATURES.

Premium Structural Engineered Wood Products. Technical Data for. LVL Flange and MSR Flange I-Joists

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension

Allowable Holes in VERSA-LAM Beams

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

December 1, Table of Contents. TABLE TOPIC PAGE General TABLE TOPIC PAGE. Roof Decks (continued) (Diaphragm Shear Values)

Pipe Strut vs. Laced Strut

Multideck 50-V2 Features and Applications

TAS. Fire Design Example Based on European Standard ENV (Eurocode 9) TALAT Lecture pages. Advanced Level

STRUCTURAL EDGE ENGINEERING, PLLC

Quick Selection Guide

2.0E ES LVL U.S. Design Manual

DESIGN TABLE OF PURLIN, GIRT, EAVE BEAM, TIE RUNNER

APPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

Design Guide Standard Joists INTERACTIVE PDF

DeltaStud - Lightweight Steel Framing

western for products manufactured in White City, Oregon

Load Bearing Capacity lb kg. Type of Surface Fibreglass bonded on steel. Clearance (Inclined roof) 22 9 to to 7.

Multideck 80-V2 Features and Applications

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

BOISE GLULAM 24F-V4 IJC

STANDARD SPECIFICATIONS

Multideck 60-V2. Contents

Length and Depth 42 4 x x m Clearance (Inclined roof) 22 9 to to 7.76 m Maximum Height from Banners

Behavior & Design. Curved Girder. Curved Steel Girder Bridges. PDF Created with deskpdf PDF Writer - Trial ::

Bridge Overhang Brackets

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts...

4.5 COMPOSITE STEEL AND CONCRETE

Cladding Profiles. Technical Specifications

FireFree ScandiBoard 850 Passive Fire Protection of Steel Constructions R30 - R180

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM

2013 IOWA FFA AGRICULTURAL MECHANICS CAREER DEVELOPMENT EVENT WRITTEN EXAMINATION

Mid-States Concrete Industries flexicore

EXAMPLES GEARS. page 1

WARRANTY AND LIMITATIONS

Submittal Data. Fiberglass Bondstrand 3000A Pipe

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

1¾" BEAMS & HEADERS. [1¾" THICKNESS] NER F b E Design Values LAMINATED VENEER LUMBER. Finnforest USA, Engineered Wood Division

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS CANADA

2250 FT FLAT TOP BELTS (Pitch mm)

Lifting Capacity 8000 lb 3626 kg. Type of Surface Fibreglass bonded on steel. Clearance (Inclined roof) 18 1 to m to 5.

Bending strength, density and modulus of elasticity of BauBuche laminated veneer lumber in comparison with other materials.

Light gage steel framing

NEW ZEALAND GLULAM SPAN TABLES

LYSAGHT SELECT SEAM Series

COMPOSITE FLOOR SYSTEM

The Entice System is intended for exterior installations requiring the use of insulating glass.

I-Beam Festoon Instruction Manual

Structurlam Mass Timber Corporation Revised October 11, 2018

PIPINGSOLUTIONS, INC.

PD Thrust Restraint Design Equations and Tables

Design & Manufacturing of an Effective Steering System for a Formula Student Car

Submittal Data. Fiberglass Bondstrand 2000 Pipe pe

Lenght and Depth 34 5 x x 8.41 m Clearance (Inclined roof) 20 to m to 5.42 m Maximum Height with Banner

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

National Evaluation Service, Inc.

MECO OMAHA CANTILEVER RACK

Length and Depth 31 8 x x 8.26 m Clearance (Inclined roof) 14 6 to to 5.15 m Maximum Height from Ground

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version

SmartLVL15 Design Guide

Spruce Line photovoltaic modules

Gantry Girders in India

QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems

Transcription:

7

Single and Continuous Spans Restraint value for slenderness calculations is 1200 mm, in 10, 20, 40( kg/m 2 ) (Restraint may be by Roof Battens) Restraint value for slenderness calculations is 600 mm, in 70, 90 ( kg/m 2 ) (Restraint may be by Tile Battens) K6 factor of 1.0 used. K23 factor applied to bending strength. INCLUDES J2 value of 1.5 used for DL Deflection. 10 kg/m 2 Pre-camber radius of 0m used. 20 kg/m 2 Roof Pitch of 25.0 deg used in load calculations. 40 kg/m 2 N3 WIND AREAS Downdrag loads were ignored. 70 kg/m 2 Total Uplift coefficient was 1.6 90 kg/m 2 1: Dead Load = Span / 300 or maximum 20 mm. 2: Roof Live Load = Span / 250 3: Wind Uplift = Span / 150. Timber Properties: Fb = 11 MPa, Elasticity = 13300 MPa Density = 600 kg/m3, Fs = 1.25 MPa Ft = 5.2 MPa, Fc = 11 MPa. Timber Properties: Fb = 11 MPa, Elasticity = 13300 MPa Density = 600 kg/m3, Fs = 1.25 MPa Ft = 5.2 MPa, Fc = 11 MPa. Load Cases: 1: Dead Load 2: Roof Live Load 3: Wind Uplift MAX ROOF PITCH = 25 DEGREES Roof pitch used in calculations is 25 degrees for Roof pitches greater than 25 degrees but not exceeding 45 degrees you may multiply rafter span (Plan View ) x 1.28 then use answer to read rafter span as normal. CONTINUOUS SPAN RAFTERS Continuous Rafter may have unequal spans, provided major span does not exceed 1.25 times the length of the minor span, major span length should be used in determining rafter size. 8

Diagrams for use in determining rafter span ( plan width) for use in rafter tables. Max roof pitch 25 degrees. Single Span Rafter OH OH SPAN SPAN Birdsmouth and overhang details For Rafters Birdsmouthed up to 1/3 of their depth reduce Max Overhang as read from table by 35%. Maximum Overhang Figure 16 Continuous Span Rafter OH SPAN SPAN Major Minor Span 9

Roof load of Light Sheet (10kg/m2) Maximum Permissible Span (m) Single Span Continuous Span Beam Rafter Spacing (m) Beam Rafter Spacing (m) Size 0.45 0.60 0.90 0.12 Size 0.45 0.60 0.90 0.12 126 x 38 4.7 4.2 3.7 3.4 126 x 38 6.4 5.6 4.7 4.1 168 x 38 6.2 5.7 5.2 5.0 168 x 38 8.1 7.3 6.4 5.5 210 x 38 7.4 7.2 6.7 6.4 210 x 38 9.4 9.0 8.0 6.9 252 x 38 8.3 8.0 7.6 7.2 252 x 38 10.5 10.1 9.2 7.9 126 x 42 4.9 4.4 3.9 3.5 126 x 42 6.5 6.0 5.0 4.3 168 x 42 6.4 5.9 5.4 5.2 168 x 42 8.2 7.9 6.7 5.8 210 x 42 7.5 7.3 6.8 6.5 210 x 42 9.5 9.1 8.5 7.3 252 x 42 8.4 8.1 7.7 7.4 252 x 42 10.6 10.2 9.7 8.6 294 x 42 9.2 9.0 8.5 8.2 294 x 42 11.6 11.3 10.7 9.6 126 x 65 5.6 5.1 4.5 4.4 126 x 65 7.6 7.0 6.3 5.4 168 x 65 7.4 6.9 6.5 6.3 168 x 65 9.3 9.0 8.5 7.3 210 x 65 8.5 8.2 7.8 7.5 210 x 65 10.6 10.3 9.9 9.1 252 x 65 9.4 9.2 8.8 8.5 252 x 65 11.8 11.5 11.1 10.7 294 x 65 10.3 10.1 9.7 9.3 294 x 65 12.9 12.7 12.2 11.7 336 x 65 11.1 10.9 10.5 10.1 336 x 65 14.0 13.7 13.2 12.8 378 x 65 11.9 11.6 11.2 10.9 378 x 65 14.9 14.6 14.2 13.7 420 x 65 12.6 12.4 12.0 11.6 420 x 65 15.8 15.6 15.1 14.7 126 x 85 6.1 5.5 5.0 4.9 126 x 85 8.0 7.8 7.2 6.2 168 x 85 7.6 7.4 7.0 6.8 168 x 85 9.5 9.3 8.9 8.4 210 x 85 8.6 8.4 8.1 7.8 210 x 85 10.9 10.6 10.2 9.8 252 x 85 9.6 9.4 9.0 8.8 252 x 85 12.1 11.8 11.4 11.0 294 x 85 10.5 10.3 9.9 9.6 294 x 85 13.2 12.9 12.5 12.1 336 x 85 11.3 11.1 10.7 10.5 336 x 85 14.2 13.9 13.5 13.2 378 x 85 12.0 11.8 11.5 11.2 378 x 85 15.1 14.9 14.5 14.1 420 x 85 12.7 12.6 12.2 12.0 420 x 85 16.0 15.8 15.4 15.0 462 x 85 13.4 13.2 12.9 12.6 462 x 85 16.9 16.7 16.3 15.9 504 x 85 14.1 13.9 13.6 13.3 504 x 85 17.7 17.5 17.1 16.7 Bearing Lengths: 35mm for single span supports, or end supports for continuous members. 45mm for internal supports on continuous members or cantilever supports. 10

Roof load of Sheet (20kg/m2) Maximum Permissible Span (m) Single Span Continuous Span Beam Rafter Spacing (m) Beam Rafter Spacing (m) Size 0.45 0.60 0.90 0.12 Size 0.45 0.60 0.90 0.12 126 x 38 4.4 4.1 3.6 3.3 126 x 38 6.0 5.2 4.3 3.9 168 x 38 5.7 5.4 4.8 4.4 168 x 38 7.3 6.6 5.9 5.4 210 x 38 6.7 6.4 5.9 5.4 210 x 38 8.5 8.1 7.4 6.7 252 x 38 7.6 7.2 6.7 6.4 252 x 38 9.6 9.1 8.5 7.8 126 x 42 4.5 4.2 3.8 3.5 126 x 42 6.1 5.6 4.7 4.3 168 x 42 5.9 5.5 5.0 4.5 168 x 42 7.4 7.0 6.5 6.0 210 x 42 6.8 6.5 6.0 5.6 210 x 42 8.6 8.2 7.6 7.2 252 x 42 7.7 7.4 6.9 6.5 252 x 42 9.7 9.3 8.6 8.2 294 x 42 8.5 8.2 7.6 7.2 294 x 42 10.7 10.3 9.6 9.1 126 x 65 5.5 5.1 4.5 4.4 126 x 65 7.1 6.7 6.2 5.6 168 x 65 6.8 6.5 6.0 5.7 168 x 65 8.5 8.2 7.6 7.2 210 x 65 7.8 7.5 7.0 6.7 210 x 65 9.9 9.5 8.9 8.4 252 x 65 8.8 8.5 8.0 7.6 252 x 65 11.1 10.7 10.0 9.5 294 x 65 9.7 9.3 8.8 8.4 294 x 65 12.2 11.7 11.1 10.6 336 x 65 10.5 10.1 9.6 9.2 336 x 65 13.2 12.8 12.1 11.6 378 x 65 11.2 10.9 10.4 9.9 378 x 65 14.2 13.7 13.1 12.5 420 x 65 12.0 11.6 11.1 10.7 420 x 65 15.1 14.7 14.0 13.4 126 x 85 5.9 5.5 5.0 4.7 126 x 85 7.4 7.0 6.6 6.2 168 x 85 7.0 6.8 6.3 6.0 168 x 85 8.9 8.5 8.0 7.6 210 x 85 8.1 7.8 7.4 7.0 210 x 85 10.2 9.8 9.3 8.8 252 x 85 9.0 8.8 8.3 7.9 252 x 85 11.4 11.0 10.4 10.0 294 x 85 9.9 9.6 9.2 8.8 294 x 85 12.5 12.1 11.5 11.1 336 x 85 10.7 10.5 10.0 9.6 336 x 85 13.5 13.2 12.6 12.1 378 x 85 11.5 11.2 10.7 10.3 378 x 85 14.5 14.1 13.5 13.0 420 x 85 12.2 12.0 11.5 11.1 420 x 85 15.4 15.0 14.4 13.9 462 x 85 12.9 12.6 12.2 11.8 462 x 85 16.3 15.9 15.3 14.8 504 x 85 13.6 13.3 12.8 12.4 504 x 85 17.1 16.7 16.1 15.6 Bearing Lengths: 35mm for single span supports, or end supports for continuous members. 45mm for internal supports on continuous members or cantilever supports. 11

Roof load of Sheet & Ceiling (40kg/m2) Maximum Permissible Span (m) Single Span Continuous Span Beam Rafter Spacing (m) Beam Rafter Spacing (m) Size 0.45 0.60 0.90 0.12 Size 0.45 0.60 0.90 0.12 126 x 38 3.6 3.3 3.0 2.7 126 x 38 5.0 4.5 3.8 3.3 168 x 38 4.8 4.4 3.9 3.6 168 x 38 6.4 5.9 5.0 4.5 210 x 38 5.9 5.4 4.9 4.5 210 x 38 7.5 7.0 6.2 5.5 252 x 38 6.7 6.4 5.8 5.3 252 x 38 8.5 8.0 7.2 6.3 126 x 42 3.8 3.5 3.1 2.9 126 x 42 5.1 4.7 4.1 3.7 168 x 42 5.0 4.5 4.1 3.8 168 x 42 6.5 6.1 5.5 5.0 210 x 42 6.0 5.6 5.0 4.7 210 x 42 7.6 7.2 6.6 6.0 252 x 42 6.9 6.5 6.0 5.5 252 x 42 8.6 8.2 7.5 7.0 294 x 42 7.6 7.2 6.7 6.3 294 x 42 9.6 9.1 8.4 7.8 126 x 65 4.7 4.4 3.9 3.5 126 x 65 6.2 5.9 5.3 4.8 168 x 65 6.0 5.7 5.1 4.7 168 x 65 7.6 7.2 6.6 6.2 210 x 65 7.0 6.7 6.2 5.7 210 x 65 8.9 8.4 7.8 7.3 252 x 65 8.0 7.6 7.0 6.6 252 x 65 10.0 9.5 8.8 8.3 294 x 65 8.8 8.4 7.8 7.4 294 x 65 11.1 10.6 9.8 9.3 336 x 65 9.6 9.2 8.6 8.1 336 x 65 12.1 11.6 10.8 10.2 378 x 65 10.4 9.9 9.3 8.8 378 x 65 13.1 12.5 11.7 11.1 420 x 65 11.1 10.7 10.0 9.5 420 x 65 14.0 13.4 12.6 11.9 126 x 85 5.0 4.7 4.2 3.8 126 x 85 6.6 6.2 5.6 5.2 168 x 85 6.3 6.0 5.4 5.0 168 x 85 8.0 7.6 7.0 6.6 210 x 85 7.4 7.0 6.5 6.1 210 x 85 9.3 8.8 8.2 7.7 252 x 85 8.3 7.9 7.4 7.0 252 x 85 10.4 10.0 9.3 8.8 294 x 85 9.2 8.8 8.2 7.8 294 x 85 11.5 11.1 10.3 9.8 336 x 85 10.0 9.6 9.0 8.5 336 x 85 12.6 12.1 11.3 10.8 378 x 85 10.7 10.3 9.7 9.3 378 x 85 13.5 13.0 12.2 11.7 420 x 85 11.5 11.1 10.4 9.9 420 x 85 14.4 13.9 13.1 12.5 462 x 85 12.2 11.8 11.1 10.6 462 x 85 15.3 14.8 14.0 13.4 504 x 85 12.8 12.4 11.8 11.2 504 x 85 16.1 15.6 14.8 14.1 Bearing Lengths: 35mm for single span supports, or end supports for continuous members. 45mm for internal supports on continuous members or cantilever supports. 12

Roof load of Tiles (70kg/m2) Maximum Permissible Span (m) Single Span Continuous Span Beam Rafter Spacing (m) Beam Rafter Spacing (m) Size 0.45 0.60 0.90 0.12 Size 0.45 0.60 0.90 0.12 126 x 38 3.1 2.9 2.5 2.3 126 x 38 4.2 3.9 3.4 3.1 168 x 38 4.1 3.8 3.3 3.0 168 x 38 5.6 5.1 4.5 4.1 210 x 38 5.1 4.7 4.1 3.8 210 x 38 6.6 6.2 5.6 5.1 252 x 38 6.0 5.6 5.0 4.5 252 x 38 7.6 7.1 6.5 6.1 126 x 42 3.2 2.9 2.6 2.4 126 x 42 4.4 4.0 3.5 3.2 168 x 42 4.2 3.9 3.5 3.2 168 x 42 5.7 5.3 4.7 4.2 210 x 42 5.3 4.8 4.2 3.9 210 x 42 6.8 6.4 5.7 5.3 252 x 42 6.1 5.7 5.1 4.7 252 x 42 7.7 7.3 6.6 6.2 294 x 42 6.8 6.4 5.9 5.4 294 x 42 8.6 8.1 7.4 7.0 126 x 65 4.0 3.7 3.3 3.0 126 x 65 5.4 5.0 4.4 4.1 168 x 65 5.3 4.8 4.3 3.9 168 x 65 6.8 6.4 5.9 5.3 210 x 65 6.3 6.0 5.3 4.9 210 x 65 8.0 7.5 6.9 6.5 252 x 65 7.2 6.8 6.2 5.9 252 x 65 9.1 8.6 7.9 7.4 294 x 65 8.0 7.6 7.0 6.6 294 x 65 10.1 9.6 8.8 8.3 336 x 65 8.8 8.3 7.7 7.2 336 x 65 11.1 10.5 9.7 9.1 378 x 65 9.5 9.0 8.3 7.9 378 x 65 12.0 11.4 10.5 9.9 420 x 65 10.2 9.7 9.0 8.5 420 x 65 12.9 12.2 11.3 10.7 126 x 85 4.4 4.0 3.5 3.2 126 x 85 5.9 5.4 4.8 4.4 168 x 85 5.6 5.3 4.7 4.3 168 x 85 7.2 6.8 6.2 5.8 210 x 85 6.7 6.3 5.7 5.3 210 x 85 8.4 8.0 7.3 6.9 252 x 85 7.6 7.2 6.6 6.2 252 x 85 9.5 9.0 8.3 7.8 294 x 85 8.4 8.0 7.4 7.0 294 x 85 10.6 10.1 9.3 8.8 336 x 85 9.2 8.8 8.1 7.6 336 x 85 11.6 11.0 10.2 9.6 378 x 85 9.9 9.5 8.8 8.3 378 x 85 12.5 11.9 11.1 10.5 420 x 85 10.6 10.2 9.5 9.0 420 x 85 13.4 12.8 11.9 11.3 462 x 85 11.3 10.8 10.1 9.6 462 x 85 14.3 13.6 12.7 12.1 504 x 85 12.0 11.5 10.7 10.2 504 x 85 15.1 14.5 13.5 12.8 Bearing Lengths: 35mm for single span supports, or end supports for continuous members. 45mm for internal supports on continuous members or cantilever supports. 13

Roof load of Tiles & Ceiling (90kg/m2) Maximum Permissible Span (m) Single Span Continuous Span Beam Rafter Spacing (m) Beam Rafter Spacing (m) Size 0.45 0.60 0.90 0.12 Size 0.45 0.60 0.90 0.12 126 x 38 2.9 2.6 2.3 2.1 126 x 38 3.9 3.6 3.2 2.8 168 x 38 3.8 3.5 3.0 2.8 168 x 38 5.1 4.7 4.2 3.8 210 x 38 4.7 4.4 3.8 3.5 210 x 38 6.3 5.9 5.1 4.6 252 x 38 5.6 5.1 4.5 4.2 252 x 38 7.2 6.7 6.1 5.4 126 x 42 3.0 2.7 2.4 2.2 126 x 42 4.1 3.7 3.2 3.0 168 x 42 3.9 3.6 3.2 2.9 168 x 42 5.3 4.8 4.3 3.9 210 x 42 4.8 4.5 3.9 3.6 210 x 42 6.4 6.0 5.3 4.8 252 x 42 5.7 5.3 4.7 4.3 252 x 42 7.3 6.9 6.3 5.8 294 x 42 6.5 6.1 5.4 5.0 294 x 42 8.2 7.7 7.0 6.6* 126 x 65 3.8 3.5 3.0 2.7 126 x 65 5.0 4.7 4.1 3.7 168 x 65 4.9 4.5 4.0 3.6 168 x 65 6.5 6.1 5.4 5.0 210 x 65 6.0 5.6 5.0 4.5 210 x 65 7.6 7.1 6.5 6.1 252 x 65 6.9 6.5 5.9 5.4 252 x 65 8.6 8.1 7.4 7.0 294 x 65 7.6 7.2 6.6 6.2 294 x 65 9.6 9.1 8.3 7.8 336 x 65 8.4 7.9 7.3 6.8 336 x 65 10.6 10.0 9.2 8.6 378 x 65 9.1 8.6 7.9 7.4 378 x 65 11.5 10.8 10.0 9.4* 420 x 65 9.8 9.3 8.5 8.0 420 x 65 12.3 11.7 10.8 10.1* 126 x 85 4.1 3.7 3.3 3.0 126 x 85 5.4 5.0 4.4 4.1 168 x 85 5.3 4.8 4.4 3.9 168 x 85 6.8 6.4 5.9 5.4 210 x 85 6.4 6.0 5.4 5.0 210 x 85 8.0 7.6 6.9 6.5 252 x 85 7.2 6.8 6.3 5.9 252 x 85 9.1 8.6 7.9 7.4 294 x 85 8.0 7.6 7.0 6.6 294 x 85 10.1 9.6 8.8 8.3 336 x 85 8.8 8.4 7.7 7.2 336 x 85 11.1 10.5 9.7 9.1 378 x 85 9.5 9.1 8.4 7.9 378 x 85 12.0 11.4 10.5 9.9 420 x 85 10.2 9.7 9.0 8.5 420 x 85 12.9 12.3 11.4 10.7 462 x 85 10.9 10.4 9.6 9.1 462 x 85 13.7 13.1 12.1 11.5* 504 x 85 11.5 11.0 10.2 9.7 504 x 85 14.5 13.9 12.9 12.2* Bearing Lengths: 35mm for single span supports, or end supports for continuous members. 45mm for internal supports on continuous members or cantilever supports. *For continuous spans: denotes member must have a min 65mm bearing length at the internal support, and 45mm for ends supports of continuous members. 14

RAFTER OVERHANGS Maximum Permissible Overhang (m) Plan Dimension Roof load of Light Sheet (10kg/m2) Roof load of Sheet (20kg/m2) Beam Rafter spacing (m) Beam Rafter spacing (m) Size 0.45 0.6 0.9 1.2 Size 0.45 0.6 0.9 1.2 126 x 38 1.2 1.1 1.1 1.0 126 x 38 1.2 1.0 1.0 1.0 168 x 38 1.9 1.8 1.8 1.7 168 x 38 1.9 1.8 1.6 1.6 210 x 38 2.7 2.6 2.4 2.0 210 x 38 2.7 2.6 2.4 2.2 252 x 38 3.6 3.4 2.8 2.4 252 x 38 3.6 3.4 3.1 2.8 126 x 42 1.4 1.4 1.4 1.4 126 x 42 1.4 1.4 1.4 1.3 168 x 42 2.1 2.0 2.0 2.0 168 x 42 2.1 2.0 2.0 2.0 210 x 42 3.0 2.8 2.8 2.4 210 x 42 3.0 2.8 2.8 2.8 252 x 42 4.0 3.8 3.5 3.0 252 x 42 4.0 3.8 3.6 3.3 294 x 42 4.8 4.4 4.0 3.4 294 x 42 4.8 4.4 4.0 3.8 126 x 65 1.7 1.7 1.7 1.7 126 x 65 1.7 1.7 1.7 1.7 168 x 65 2.6 2.5 2.5 2.5 168 x 65 2.6 2.5 2.5 2.5 210 x 65 3.8 3.6 3.4 3.2 210 x 65 3.8 3.6 3.4 3.2 252 x 65 4.7 4.4 4.0 3.8 252 x 65 4.6 4.4 4.0 3.8 294 x 65 5.3 4.9 4.4 4.4 294 x 65 5.0 4.8 4.4 4.4 126 x 85 1.7 1.7 1.7 1.7 126 x 85 1.7 1.7 1.7 1.7 168 x 85 2.6 2.5 2.5 2.5 168 x 85 2.6 2.5 2.5 2.5 210 x 85 3.8 3.6 3.4 3.2 210 x 85 3.8 3.6 3.4 3.2 252 x 85 4.7 4.4 4.0 3.8 252 x 85 4.6 4.4 4.0 3.8 294 x 85 5.3 4.9 4.4 4.4 294 x 85 5.0 4.8 4.4 4.4 Overhangs from this table, suitable for rafters without birdsmouths only. For rafters with birdsmouths, see figure 16 Maximum Overhang Figure 16 Birdsmouth and overhang details For Rafters Birdsmouthed up to 1/3 of their depth reduce Max Overhang as read from table by 35% 15

RAFTER OVERHANGS Maximum Permissible Overhang (m) Plan Dimension Roof load of Sheet & Ceiling (40kg/m2) Roof loroof load of Tiles (70kg/m2) Beam Rafter spacing (m) Beam Rafter spacing (m) Size 0.45 0.6 0.9 1.2 Size 0.45 0.6 0.9 1.2 126 x 38 1.1 1.0 1.0 1.0 126 x 38 1.2 1.1 1.0 1.0 168 x 38 1.8 1.7 1.5 1.4 168 x 38 2.0 2.0 1.6 1.6 210 x 38 2.7 2.4 2.1 1.9 210 x 38 2.8 2.7 2.4 2.2 252 x 38 3.6 3.0 2.6 2.4 252 x 38 3.2 3.0 2.8 2.6 126 x 42 1.4 1.4 1.2 1.2 126 x 42 1.4 1.3 1.2 1.1 168 x 42 2.1 2.0 2.0 1.8 168 x 42 2.2 2.1 1.9 1.8 210 x 42 3.0 2.8 2.8 2.4 210 x 42 3.0 2.8 2.6 2.4 252 x 42 3.8 3.6 3.3 2.9 252 x 42 3.4 3.2 2.9 2.8 294 x 42 4.2 4.0 3.7 3.4 294 x 42 3.8 3.6 3.2 3.0 126 x 65 1.7 1.7 1.7 1.7 126 x 65 1.8 1.7 1.6 1.6 168 x 65 2.6 2.5 2.5 2.5 168 x 65 2.8 2.6 2.4 2.2 210 x 65 3.6 3.4 3.2 3.0 210 x 65 3.2 3.1 2.8 2.6 252 x 65 4.1 3.9 3.6 3.4 252 x 65 3.7 3.5 3.2 3.0 294 x 65 4.6 4.4 4.0 3.8 294 x 65 4.2 3.9 3.6 3.4 126 x 85 1.7 1.7 1.7 1.7 126 x 85 1.8 1.7 1.6 1.6 168 x 85 2.6 2.5 2.5 2.5 168 x 85 2.8 2.6 2.4 2.2 210 x 85 3.6 3.4 3.2 3.0 210 x 85 3.2 3.1 2.8 2.6 252 x 85 4.1 3.9 3.6 3.4 252 x 85 3.7 3.5 3.2 3.0 294 x 85 4.6 4.4 4.0 3.8 294 x 85 4.2 3.9 3.6 3.4 Roof load of Tiles & Ceiling (90kg/m2) Beam Rafter spacing (m) Beam Rafter spacing (m) Size 0.45 0.6 0.9 1.2 Size 0.45 0.6 0.9 1.2 126 x 38 1.2 1.0 1.0 0.9 126 x 65 1.8 1.7 1.6 1.4 168 x 38 2.0 1.8 1.6 1.4 168 x 65 2.6 2.5 2.2 2.1 210 x 38 2.7 2.6 2.2 2.0 210 x 65 3.1 2.9 2.6 2.5 252 x 38 3.1 2.9 2.6 2.4 252 x 65 3.6 3.4 3.0 2.8 0.45 0.6 0.9 1.2 294 x 65 4.0 3.7 3.4 3.2 126 x 42 1.4 1.2 1.1 1.0 0.45 0.6 0.9 1.2 168 x 42 2.2 2.1 1.8 1.6 126 x 85 1.8 1.7 1.6 1.4 210 x 42 2.8 2.6 2.4 2.2 168 x 85 2.6 2.5 2.2 2.1 252 x 42 3.2 3.0 2.8 2.6 210 x 85 3.1 2.9 2.6 2.5 294 x 42 3.6 3.4 3.1 2.9 252 x 85 3.6 3.4 3.0 2.8 Overhangs from this table, suitable for 294 x 85 4.0 3.7 3.4 3.2 Overhangs from this table, suitable for rafters without birdsmouths only. For rafter with birdsmouths, see figure 16. 16