Installation & Operation

Similar documents
PowerAir Compressor Installation

PRE-INSTALLATION GUIDE

ClassicSeries Compressor Installation

Dental Dry Suction. Installation/User Guide

HALLMARK INDUSTRIES INC

PowerMax Surgical Suction Producers

LAWN SPRINKLER, IRRIGATION PUMP

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Users Manual Certified Series Direct Drive Pump 1-7 LPM

DIAMOND P R O D U C T S

STAR STOP SHALLOW WELL JET PUMP

PowerVac. Service and Parts Manual P3 P5 P7. Single Vac Units. Twin Vac Units P6 P10 P14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY.

QUALITY MISTING PUMPS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual

SHALLOW WELL JET PUMP

QUALITY MISTING PUMPS

TECH WEST INC. Manufacturers of Dental Vacuum and Air Systems N. Argyle Ave. Fresno, CA (559) (800) FAX (559)

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

ULTRA CLEAN OILLESS COMPRESSOR

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Dental Compressed Air System

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Dispenser & Warmer RIC-1909 RIC-1909EXP

DECADE 1021 SOLO CHAIR

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Reverse Osmosis System

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION, OPERATING AND SERVICE MANUAL

PowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Atomizer 36-DC User Guide

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

PRE-PLUMBED SEWAGE SYSTEM

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

COOL DRAFT INSTRUCTIONS OWNER S MANUAL CONTENTS. Cool Draft MiniMister 14 Misting Fan CDMP1420BLU

HEAVY DUTY ONBOARD AIR SYSTEM

Congratulations PRE-OPERATION SETUP

Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

Cascade Owners Manual

SUPER PUMP OUT SYSTEM

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

CAT PUMPS (7.5 HP) Pump Stations DU PS1901C-PG & DU PS1901CPG2 DU PS1903C-PG & DU PS1903CPG2

Scale Feeder Manifold Water Filtration System Instruction Manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

Items # and #

Manual Concentrate Management System

Material required for drilled well application (indoor use only)

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

PPM EO-100 TM. Operation Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Operators Manual. Recirculating Chiller /06/08

Artesian2 Owners Manual

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

DEMA Pro-Fill II Sink Dispenser

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

AQUA-LAB Chemical Dispensing System. Operating Manual REV L

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Active Evacuation System (AES)

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Artesian2 Owners Manual

PowerFLO 5800/5900 Series

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Surface Mounted Bottle Fillers

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

SUBMERSIBLE SUMP PUMPS

AD-830. Parts Manual thru 1997

SUBMERSIBLE SUMP PUMPS

GARDEN HOSE UTILITY PUMP

ProFlo FatBoy

Modular Outdoor Fountain System

VT Oil-Free Range Operators Handbook

Model 8346/8346CRP Shower & Eye/Face Wash

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Rock Compressors. Service and Parts Manual. Twin R22 Triple R42 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers: R42 Shown

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

SPC-PANEL Simplex, Single Phase Pump Control Panel

Kit Drain Water Tempering Kit

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

ESE Series Cast Iron Sewage Pumps

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

ArtesianPro Owners Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

400 Series Spin-on Fuel Filter/Water Separators

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

KLW4000D Multi-Port Power Pack

Transcription:

2" PVC Vent Pipe (Provided By Plumber) 2" PVC Vent Connection (Vent To Outdoors) 1/4" x 8' High Pressure Water Inlet Hose with Water Control Valves Located On Platform (1/2" or 1/4" MPT Fittings Provided) See Note On Local Codes 1 1/2" P-Trap With 1" Air Gap (Provided By Plumber) (Refer To Local Plumbing Codes) Low Voltage Wires For 24V Remote Operation ( and e Switching) White = Light "ON/OFF" 1/2 Amp Circuit Breaker Switches (Provided) Lifting Handle Receiver Optional Wall Mounting (Extra Hose Provided) Air / Water Separator (Provided With Separator Models) Disconnect Box (Provided By Electrician) (1 Circuit Per Pump) 6' Conduit (Provided) 1" x 4' Flex PVC Inlet Tubing (Do Not Cement) (1 1/4" x 4' Flex PVC On Twin 2 Or 3 HP Models) (Provided) 1" PVC Slip Coupling and MPT Adapter (Provided) NOTE: Some Local Codes Require A uced Pressure (RP) Backflow Preventor On The Incoming Water Line. (Not Provided) Description: Apollo by Midmark V acuum Systems have been tested and approved by various regulatory test agencies. The following list contains Apollo File Numbers that may be helpful if questions arise regarding installation inspections. Underwriter s Laboratories (UL) (cul)... File Number: MH13627 U.S. Food and Drug Administration (FDA)... File Number: 2937927 City of Los Angeles Mechanical Test Labs... File Number M880066 This dental vacuum system should only be installed by qualified personnel. Should any questions arise during the installation, call Apollo by Midmark Technical Support between the hours of 8:00 a.m. to 5:00 p.m. (Eastern Standard Time). Unpacking The System: Place the Vacuum System in a clean, dry, well ventilated area, on a solid, level surface. Consider sound level and insulate as needed. Be sure that adequate ventilation is available as the Vacuum System is air-cooled. Ambient temperature in the equipment room should be within the temperature range of 40 degrees Fahrenheit (4 o C) minimum to 100 degrees Fahrenheit (38 o C) maximum. Do Not Allow The Vacuum To Freeze. 1. Remove the cardboard from the shipping platform. 2. Inspect pump for freight damage and confirm that the Pump Installation Kit is in the box. 3. Remove the pump from the shipping platform. Apollo by Midmark 60 Vista Drive Versailles, Ohio 45380-0286 Technical Support 1-800- Midmark Fax 877-249-1793 www.midmark.com Page 1

Vacuum Pump Specifications: Model Max Width Depth Height Shipping Total Volt Amperage Hz Wire Breaker Users *** Weight HP (Per Pump) GA* Size** AVG10TNFX / AVU10TNFX 6 66 cm 44 cm 76 cm 64 kg 2 220 8.1 50 14 2@20 AVG10TNX / AVU10TNX 6 26 in 18 in 30 in 140 lb 2 115/208-230 16.2/8.1 60 10/14 2@30/2@20 AVB10TN* 5 26 in 18 in 20 in 140 lb 2 115/208-230 16.2/8.1 60 10/14 2@30/2@20 AVB10TNFX 5 66 cm 44 cm 76 cm 66 kg 2 220 8.1 50 14 2@20 AVB10TNX 5 26 in 18 in 30 in 145 lb 2 115/208-230 16.2/8.1 60 10/14 2@30/2@20 AVG15TNFX / AVU15TNFX 7 66 cm 44 cm 76 cm 70 kg 3 220 11 50 14 2@20 AVG15TNX / AVU15TNX 7 26 in 18 in 30 in 115 lb 3 208-230 11 60 14 2@20 AVB15TN* 6 26 in 18 in 20 in 155 lb 3 208-230 11 60 14 2@20 AVB15TNFX 6 66 cm 44 cm 76 cm 73 kg 3 220 11 50 14 2@20 AVB15TNX 6 26 in 18 in 30 in 160 lb 3 208-230 11 60 14 2@20 AVB20TNX 8 26 in 18 in 32 in 165 lb 4 208-230 12.4 60 14 2@20 AVG20TNFX / AVU20TNFX 10 66 cm 44 cm 81 cm 75 kg 4 220 12.4 50 14 2@20 AVG20TNX / AVU20TNX 10 26 in 18 in 32 in 165 lb 4 208-230 12.4 60 14 2@20 AVG30TNFX / AVU30TNFX 12 66 cm 44 cm 81 cm 80 kg 6 220 14 50 14 2@30 AVG30TNX / AUG30TNX 12 26 in 18 in 32 in 175 lb 6 208-230 14 60 14 2@30 For Recycler option, add R to last prefix only. Example: AVB10TNR. *Non separator models, VB10TN and VB15TN, are not recommended for single pump operation. ** Each pump requires a separate electrical circuit. *** Height with Exhaust Separator Dual Voltage Models Remote Lighted Switch LOW VOLTAGE CONTROL 2 3 5 6 7 8 115 Volt Supply To Terminals 1 and 4 Install Jumpers From Terminals: 3 to 4 5 to 6 7 to 8 3 4 5 6 7 8 (FACTORY SETTING) 230 Volt Supply To Terminals 1 and 2 Install Jumpers From Terminals: 2 to 3 6 to 7 Third Jumper Not Required See Low Voltage Control See Low Voltage Control Solenoid Coil 1/2 Amp ON / OFF Circuit Breaker Switch 1/2 Amp ON / OFF Circuit Breaker Switch Solenoid Coil 24VAC Secondary Transformer 115 or 230V Primary Motor Leads Motor Leads 115 or 230V Primary Transformer 24VAC Secondary IMPORTANT: All Vacuum Systems are to be installed according to local plumbing and electrical codes. Never operate the equipment without complete and proper grounding. Page 2

Single Voltage Models Remote Lighted Switch 230 Volt Supply To Terminals LOW VOLTAGE CONTROL See Low Voltage Control See Low Voltage Control Solenoid Coil 1/2 Amp ON / OFF Circuit Breaker Switch 1/2 Amp ON / OFF Circuit Breaker Switch Solenoid Coil Motor Leads Motor Leads 230V Primary 24VAC Secondary Transformer 230V Primary Transformer 24VAC Secondary A. Electrical Hook-Up Requirements: Low Voltage Line (24V) 18-3 Thermostat wire from each remote control switch to each vacuum; if low voltage remote control switching is desired. and e wires are for switching, the White wire is for a lighted switch, paired with. Line Voltage (60 Hz) Two, single-phase, 115 or 208-230 volt, 60 Hz, supply circuit with approved ground connection required. The 1HP units are dual voltage 115/208-230 volt. The 1 1/2, 2 and 3HP units are 230 volts only. All units are factory wired for 208-230 volt operation: 208-230 volt operation is recommended for maximum efficiency. Line Voltage (50 Hz) Two, single phase, 220 volt, 50 Hz., supply circuit with approved ground connection is required. All units are factory wired for 220 volt operation: 220 volt operation is recommended for maximum efficiency. B. Plumbing Hook-Up Requirements: (See Illustration on Page 1) Water Line 1/2 inch (13mm) cold water supply line with shut off valve terminating in 1/2 inch (13mm) FPT. The line must be flushed out with 5 gallons of water prior to connection to vacuum. IMPORTANT: Water is essential for the operation and longevity of the pump. The supply must not be restricted or interrupted during operation. Water with high mineral content may cause mineral build-up and create water starvation, leading to seal failure. A water softener and filter are recommended for this situation. (*To prevent gradual buildup, use StayClean Mineral Deposit Remover) Waste Line Water drains to sewer terminating in: Option A - Floor sink. Option B - P-trap adapted to 3/4 inch (19mm) PVC slip connection, A 1 inch (25mm) air gap may be required by local code. Page 3

Air Vent 2 inch PVC air vent to outdoors. Do not cap vent, serious back pressure may result in pump failure. Vacuum Line (Do Not Cement) 1 inch (25mm) PVC female slip connection. 2 and 3 HP models require a 1 1/4 inch (38mm) PVC slip connection. Guidelines for the proper design of a vacuum piping system are given in the following sections. IMPORTANT: Continuosly running sinks or cuspidors must NEVER be connected to the vacuum piping system as pump failure may result. C. Vacuum Piping System Guidelines: The design of the vacuum piping can have a large effect on the efficiency and reliability of the dental vacuum system. Experience has shown that the most effective vacuum piping designs are based on the air velocity that will occur in the lines. The velocity must be high enough to entrain all liquids and sediment in the air flow so that they do not accumulate in the lines. At the same time; the velocity must not be so high as to cause unacceptable vacuum losses. The Vacuum Line Sizing chart is based on maintaining an optimum air flow velocity according to the criteria described above. Use of single size pipe will result in poor performance. D. Vacuum Line Sizing Chart: Number Of Operatories Supplied Through Line Pipe Diameter In Inches (MM) 1 3/4 (19) 2 1 (25) 3 1 (25) 4 1 1/4 (32) 5 1 1/4 (32) 6 1 1/2 (38) 7 1 1/2 (38) 8 1 1/2 (38) 9 2 (50) 10 2 (50) 11 2 (50) 12 2 (50) Floor Piping Level To Vacuum Pump From Vacuum System Line Termination At Vacuum Pump (Low Restriction Trap) To Vacuum Pump Y Tee (Flow Diagram) 1/2" (13MM) Pipe Main Vacuum Line 1 1/2" Pipe 38MM 1 1/4" Pipe 32MM 1 1/4" Pipe 32MM 1" Pipe 25MM Vacuum System 1" Pipe 25MM 3/4" Pipe 19MM Sample Vacuum Piping Installation For 7 Operatory System 3/4" (19MM) Branch Line To Junction Box (7 Places) 3/4" Pipe 19MM 1" Pipe 25MM NOTE: Use the number of operatories being supplied, not the number of outlets within the operatories to determine line size at any given point. Branch lines to individual operatories off of the main suction line should be 3/4 inch diameter. Overhead System Line Termination (Floor Level Junction Box) 1/2" (13MM) Line To Floor Level Junction Box 45 Els 1/2" (13MM) Pipe From This Bushing To Junction Box Main Vacuum Line Overhead System Line Termination (In Wall Junction Box) 1/2" (13MM) Line To Junction Box On Wall A Trap Is Required Here To Prevent Backflow A Trap Is Required Here To Help Prevent Backflow The vacuum lines should be supported to prevent sag and should be sloped 1/4 inch (6 mm) for every 10 feet (3m) towards the vacuum pump. Page 4

It is of primary importance to minimize 90 degree turns in the system. These will not only cause vacuum losses, but will also provide areas where sediment can accumulate. A combination of two 45 degree elbows are preferable to a 90 degree elbow. Restrictions in the line will also cause vacuum loses. Y -tee fittings should be used whenever possible. Overhead systems require the use of the next largest size vacuum pump. Overhead systems also require a 1/2 inch (13mm) line rather than 3/4 inch (19mm) from the operatories to the main line, and special provisions to ensure that liquids do not travel back into the operatories. A sample vacuum piping diagram is shown. Consult Apollo Technical Support for further information regarding vacuum line sizing. Typical Installation Air / Water Separator (Provided With Separator Models) 2" PVC Vent To Outside Of Building (Provided By Plumber) *Do Not Cap 1 1/2" P-Trap With 1" Air Gap (Provided By Plumber) Fresh Water Line 32" Max. Operatory Piping Termination Or 6" Floor Sink 2' Max. 5' Max 3' Max. E. Installing Vacuum System With Exhaust Separator: 1. Place the vacuum unit on a solid level floor within 2 feet (0.6m) of waste line P-trap or floor sink. 2. The exhaust separator comes premounted to base. Should it need to be remotely wall mounted, simply glue in provided hose using 3/4 couplings (provided). Next, remove holding pins and wall mount the separator utilizing the holes in the extension tubing as mounting holes. Remember, the separator should be located at least 2 inches (5cm) above a waste connection and within 3 feet (1m) of the vacuum exhaust. 3. Connect operator y vacuum line to intake strainer using the provided suction hose. Do not cement the suction line. 4. Attach provided 3/4 inch (19mm) drain hose to P-trap or floor sink from bottom drain fitting of exhaust separator and CEMENT with PVC glue. 5. Install 2 inch (5cm) PVC vent line off the top of the exhaust separator and vent to the outdoors. *Failure to do so will result in moist air in the room. 6. Connect the provided water hose to a 1/4 or 1/2 inch (13mm) water supply line with the provided hose fittings. NOTE: It is recommended to purge at least 5 gallons of water through water line before attaching to vacuum. (Sediment in water lines of new buildings is common.) 7. Connect high voltage electrical supply lines as indicated in the electrical diagram. 8. For low voltage remote control, connect low voltage wires of corresponding color from the Apollo Master Control Panel vacuum switches. Page 5

F. Initial Start-Up: 1. Check that the water supply valves are OPEN. 2. Start the pumps. 3. Check exhaust tubing to ensure that water is flowing through the pumps. IMPORTANT: Do not run pump without full pressure water supply, or serious pump seal damage could result. 4. Check waste drain line to ensure that water is draining properly and that there are no water leaks. 5. Check vacuum gauges to ensure that each pump is functioning properly. Vacuum relief is factor y preset for 10 inches Hg (34 KPa) V acuum. 6. Store this installation manual for future reference. G. Vacuum Level Adjustment: The Vacuum level is adjustable in the range of 8 to 13 inches Hg (27 to 44 KPa). 1. Remove the filter and valve from the PVC elbow. 2. Using a 1/4 nutdriver and a phillips screwdriver adjust the center mounted screw within the valve. Each full clockwise turn increases the vacuum level by approximately 2 Hg. Must Be Removed To Adjust 1" Tee Relief / Regulator Valve Filter / Muffler Maintenance: Maintenance Procedure Daily Weekly Monthly Semi-Annually Annually Cleanse Vacuum Piping System Clean Vacuum Pump Intake Filter Clean In-Operator y Strainers Check Vacuum Level Clean And Dust Off V acuum Pumps Replace Recycler Return Lines Clean Or Replace Relief/Regulator Filter Clean Water Inlet Strainer Page 6

PROBLEM: Motor will not start when turned ON. Trouble-Shooting Guide Installation & Operation Cause: No power to pump motor. Remedy: 1. Check for proper voltage at pump terminal block input terminals(±10% of rated voltage). If proper voltage is not present, check circuit breaker and supply circuit. 2. If low voltage switching is being used, bypass low voltage circuit by connecting the red and blue wires from the top of the electrical box. 3. Reset circuit breaker switches located on top of electrical box. T o reset, momentarily turn OFF then back ON. 4. Check the voltage between the blue and white low voltage wires. If it is not between 20 and 28 V AC the ON/OFF switch or the transformer may be defective, or there is a faulty connection within the box. 5. If the voltage of step 3 is within limits and the relay contacts were not closing, replace relay. PROBLEM: Pump runs but creates insufficient suction. Cause: Vacuum intake filter clogged. Remedy: 1. Clean filter, or replace with Apollo Dispos-A-Bowl. Cause: Faulty vacuum system: Remedy: 1. Remove the vacuum inlet line from the pump. If there is good suction at the pump, but little to none in the system, the system is clogged or contains leaks. Locate the problem and repair. Cause: Low relief/regulator valve setting Remedy: 1. Adjust as illustrated in vacuum adjustment section. * Note: When adjusting be sure to block off inlet for maximum vacuum adjustment. Cause: Inadequate water supply. Remedy: 1. Make sure water supply valve to pump is fully OPEN. 2. Unscrew hex cap from water inlet strainer and check for clogged filter screen. Clean as required. 3. Check for proper voltage at water solenoid coil (115 VAC ±10%). If proper voltage exists replace water solenoid. (208 V AC ±10% on all T win 2 or 3 HP models.) 4. Check water regulator to see if it is plugged. Cause: Inadequately sized pump. Remedy: 1. Check usage chart for maximum number of simultaneous users. Upgrade if necessary. PROBLEM: Pump runs but creates excessive vacuum. Cause: Clogged vacuum relief filter. Remedy: 1. Unscrew filter/muffler from valve. Clean or replace filter media and reassemble. Cause: High relief/regulator valve setting. Remedy: 1. Adjust as indicated in vacuum level adjustment section. *Not recommended higher than 13 HG. PROBLEM: Pump will not run continuously. Cause: Overheating. Thermal protection shutdown. Remedy: 1. Check for adequate ventilation. The motor is air cooled and a ventilation fan may be required. Cause: Circuit breaker tripping. Remedy: 1. Check for incorrectly sized or defective circuit breaker. Cause: Faulty relay. Remedy: 1. Check for proper gauge size. Replace relay if contacts fail to remain closed. Page 7

Technical Service - 1-800-MIDMARK Description Part Number Description Part Number Cover - Electrical Box... ECB-80581 Bushing - 1 MPT x 3/4 FPT... PCV-50992 Dispos-A-Bowl 3/4... AVA60001 Dispos-A-Bowl 1... AVA60011 Dispos-A-Bowl 1 1/4... AVA60021 1/4 MPT x 1/4 Poly-flow... PCB-50450 Elbow - 3/4 MPT x 3/4 SLP... PVC-50207 Elbow - Street 1 NPT PVC... PVC-51021 Filter - Relief Valve 1 FPT... SVA-95819 Gauge - Vacuum... PGA-70415 Jumper - 2 Terminal 115/230 VAC... ECC-10225 Motor - 1 HP (60 Hz.)... HFM-30905 Motor - 1 HP (50 Hz.)... HFM-30915 Motor - 1 1/2 HP (60 Hz.)... HFM-30910 Motor - 1 1/2 HP (50 Hz.)... HFM-30920 Motor - 2 HP (50/60 Hz.)... HFM-30911 Motor - 3 HP (50/60 Hz.)... HFM-30912 Nipple - 3/4 MPT Close (Brass)... PCB-50475 Nipple - 3/4 x 2 (Brass)... PCB-50470 Nipple - 3/4 Close (PVC)... PVC-50520 Nipple - 1 Close (PVC)... PVC-51022 O-Ring - Pump Housing, 1 & 1.5 HP... MRP-70955 O-Ring - Pump Housing, 2 & 3 HP...MRP-70957 Relay - 24 VAC... ETR-10460 Feet - Studded Rubber...MRP-70963 Feet - Rubber Washers...MRP-70964 Seals - Shaft Seal Assembly, 1 & 1.5 HP... SVA-95845 Seals - Shaft Seal Assembly, 2 & 3 HP... SVA-95847 PVC Tee 1 x 1 x 3/4 Slip... PVC-50721 Strainer - 1 FPT Vacuum Inlet... PVC-50706 Strainer - 1 1/4 FPT Vacuum Inlet... PVC-50708 Strainer - 1/4 FPT Water... PCB-50960 StayClean 64 oz. Bottle... ASC00002 StayClean (64) 1 oz. Tubes... ASC00001 StayClean Non-Foaming Cleaner (4) 64 oz... ASC00005 Switch - 1/2 Amp Circuit Breaker... ECS-10422 Transformer - 115/220 Volt 24 VAC... ETR-10500 Tubing - 3/4 PVC (19mm)... PCT-80460 Tubing - 1 1/4 PVC (32mm)... PCT-80461 Tubing - 1/4 Poly-flow 135 psi (6mm)... PCT-80610 Union - 3/4 Slip (PVC)... PVC-50200 Valve - 1/4 FPT Anti-Siphon... PVV-50595 Valve - Check Valve Assembly (Intake)... SVA-95700 Valve - Relief / Regulator 1 MPT... PVV-85981 Valve - Solenoid 1/4 FPT 115 VAC... PVV-10470 Valve - Solenoid 1/4 FPT 230 VAC... PVV-10472 *To order parts, contact your authorized Apollo Dealer. Warranty Information: Classic Bronze = 2 Year Gold Series = 2 Year UltraVac = 3 Year All Apollo by Midmark products are thoroughly inspected and tested in accordance with rigid specifications and standards. Our products are guaranteed against defective material and workmanship from the date of shipment; provided, that the installation, operation, and maintenance is done in accordance with Apollo s procedures as outlined in the provided manuals. No other warranties, or guarantees, expressed or implied are made. Apollo s obligation under the warranty is to provide parts for the repair or, at Apollo s option, provide the replacement product, excluding labor and shipping charges. All special, incidental and/or consequential damages are excluded. Apollo will not issue credit for product without first attempting to correct the problem in the field. Written notice of breach of warranty must be provided to Apollo within the warranty period. The warranty does not cover damage resulting from the use of cleaning, disinfecting or sterilizing chemicals and processes. On vacuum products, the warranty does not cover failures due to hard water deposits. Failure to following installation and operation procedures will void the warranty. Page 8 AMI60333 Rev. 10/03