MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

Similar documents
MODEL Q-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

Model L-5 & L-5SS LIQUID LEVEL SWITCH. Specific Gravity Compensating

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

SOLAR BOLT CHARGING SYSTEM INSTALLATION GUIDE

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Push Button Pendants Manual 80 Series

QSI (Q-Star) Electronics Owner s Manual

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

ASSEMBLY OF TROLLEY TO HOIST

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Electric Pilot System Assembly, Operation, & Maintenance

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

MODEL 5120 Tire Repair Station

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Parts Manual Vermeer/ McLaughlin V750 Vacuum Machine (Serial #7G G )

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS

JD2800 Module Installation Guide

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

CRD600 Automatic Fitting Inserter

7430 Series Hastelloy / Monel / Stainless Steel Installation Instructions

10 S e r i e s PRESSURE SWITCH. features

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

20250 Module Installation Guide

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

SERIES 1000 ELECTRIC ACTUATORS

VL Series. General Purpose Compact Limit Switches. Sensing and Control

onlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control

CORN HEADER MANUAL: CNH PRE-2012

Hot Dog Roller Grills Instruction Manual Model #8023, Model #8024 and Model #8025 Model #8023SL, Model #8024SL and Model #8025SL

RDN4 - RDN8 Differential pressure switch

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

80PK-2A Type K Immersion Probe

TAPS AND DIES. American Made American Owned

MULTIPOSITION AIR CYLINDER

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

AGCO. Corn Header Manual d HEADSIGHT.COM

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

Model 809 Diaphragm Gauge Controller

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

RK Standby Battery Operator s Manual

Cincinnati, OH USA

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

RP-1350 Rev. 1. Parts List. Model 441-S Regulator. Parts List. Copyright 1999 Invensys Energy Metering

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

PRO REMOTE Series CAPACITANCE PROBE

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

RPPN3 - RPPN7 Industrial pressure switch

Installation / Operation Instructions Sunnex ORION Series Exam Lights

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

iq360xr - Dust Control Chop Saw Parts Manual 1 iq360xr 004 PM1218

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

PS11 Ultra-Long Life OEM Pressure Switches

Operation and Maintenance Manual for. Joyce/Dayton Linear Actuator Pound Capacity DC Actuator, LA152L, and LA152C

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)


I N S T R U C T I O N M A N U A L

CU6703 Module Installation Guide

CRD610 Automatic Fitting Inserter

Electric Pilot System

BUNN CDS-2 ILLUSTRATED PARTS CATALOG

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Installation, Operating & Maintenance Instructions

AFE8B BATTERY POWERED CRIMP TOOL

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

ME310B BATTERY POWERED CRIMP TOOL

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

INSTALLATION MANUAL. TORQ Locker TL GM 14 Bolt Installation Instructions. Made in USA By: Page 1 of 8

GERINGHOFF. Corn Header Manual f HEADSIGHT.COM

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

Transcription:

INSTALLATION INSTRUCTION SHEET GROMMET 'A' GROMMET 'AA' GROMMET 'B' GROMMET 'C' LEADSCREW LEADSCREW NUT STRAIN RELIEF NUT COVER 4 RETAINING SCREWS (NOT SHOWN) MICROSWITCH COMPLETE WITH 2 TERMINALS ADJUSTING SPRING MICROSWITCH BRACKET WITH SPRING LEVER BODY, COMPLETE WITH: A) SEAL SHAFT B) DIAPHRAGM C) DIAPHRAGM WASHER D) FEEDTHRU SHAFT E) PIVOT PIN F) CAP (SONICALLY WELDED) 1¼ x 1 BUSHING OPTIONAL 2 SCREWS 2 NUTS 2 SPLIT LOCKWASHERS 1 PLAIN WASHER O-RING 2 SCREWS DO NOT ATTEMPT TO REMOVE FLOAT OR FLOAT SHAFT WITHOUT FIRST GRIPPING SEAL SHAFT (A) TO PREVENT BREAKING OF SEAL BY UNTHREADING FROM FEEDTHRU SHAFT (D) FLOAT SHAFT NOTE GRIPPING FLATS F COVER TO SUIT ½ ELECTRICAL CONNECTOR FOR FLEXIBLE CONDUIT FLOAT UP ULTRA RELIABLE SINCE 1956 P. 1

MODEL L-8N Noryl body, float and bushing; Hypalon diaphragm, 316 stainless steel float shaft and screws. FOR Mild acids and bases, inorganics, some alcohols, some hydrocarbons, water, etc. SPECIFICATIONS (Same for all models except where shown) MODEL L-8R Fortron (PPS) body, float, and bushing; Viton diaphragm, 316 stainless float shaft and screws. FOR Medium acids and bases, inorganics, alcohols, most hydrocarbons. MODEL L-8CR Fortron (PPS) body, float, and bushing; Viton diaphragm, Hastelloy C float shaft, and Teflon screws. FOR Concentrated acids and bases, inorganics, alcohols, hydrocarbons, chlorinated organics, phenols, etc. WORKING FLUID SPECIFIC GRAVITY RANGE ADJUSTABLE BETWEEN 0.6 AND 1.5 AND UP. NOMINAL WORKING TEMPERATURE/PRESSURE: 180 F at 75 psig LIQUID LEVEL CHANGE TO ACTIVATE SWITCH: ¼ max. travel WEIGHT: 0.5 lb. INSTALLATION DIMENSIONS 1½ A/F HEX 1 NPT ELECTRICAL SWITCH CHARACTERISTICS SPDT UL and CSA listed 15 AMP, ½ HP at 125 or 250 VAC ½ AMP at 125 VDC, ¼ AMP at 250 VDC 5 AMP at 125 VAC (Tungsten lamp load) 10,000,000 mechanical operations median SPDT DRY CIRCUIT UL & CSA LISTED Gold cross bar contacts for computer/plc interface. 1.0 AMP or less, 5 24 VAC/DC WIDTH 1¾ 1¼ TO 1 BUSHING 2 1/32 1.350 ¼ LIQUID LEVEL DIFFERENTIAL 3 1/8 ¼ 15/16 3¼ 4 13/16 9 1/8 O.D. Grommet Size Cable OD Grommet Size Cable OD A 0.25 B 0.37 AA 0.30 C 0.50 ½ 90 F90 ½ STRAIGHT F P. 2 ULTRA RELIABLE SINCE 1956

ELECTRICAL WIRING Model L-8 is supplied with a strain relief cable fitting for use with round or plastic jacketed power cable. 1. Remove strain relief nut, grommet, and cover. 2. Strip the outer jacket of the cord back approximately 1¼, stagger ½, and strip leads ¼. 3. Remove slip-on connectors from microswitch and crimp or solder to the leads. 4. Feed the cable through the strain relief nut, grommet, and cover. NOTE: Check match of outside diameter of cable with inside diameter of grommet. No more than 0.20 of play should be evident. 5. Apply slip-on connectors to appropriate terminals of the microswitch. Slide the cover down the cable and fasten it to the body with four screws. Slide the grommet down the cable until the small end is level with the outer jacket. Push the grommet into the tapered hole of the cover, hold the jacket to prevent rotation, and tighten the strain relief nut firmly. Model L-8 supplied with F Cover F Cover allows the use of standard ½ electrical connectors to suit flexible conduits, such as Sealflex, plastic Spiraduct, etc. Attach slip-on connectors to leads and appropriate terminals of microswitch and complete wiring to electrical code. Microswitch activation may be monitored by an audible click or with and ohmmeter prior to connecting line power to the switch terminals, or by monitoring the voltage supplied to the load through the microswitch. Fig 1: Wiring schematic for power applied to load when liquid level is less than set point (power to load interrupted when level increases to above set point). Decreasing liquid level moves actuator in direction shown. Fig 2: Wiring schematic for power applied to load when liquid level is greater than set point (power to load interrupted when level decreases to below set point). Increasing liquid level moves actuator in direction shown. COM COM NO NO NC LOAD NC LOAD DECREASING LIQUID LEVEL BELOW SET POINT MOVES ACTUATOR IN DIRECTION SHOWN HOT LINE INCREASING LIQUID LEVEL ABOVE SET POINT MOVES ACTUATOR IN DIRECTION SHOWN HOT LINE ULTRA RELIABLE SINCE 1956 P. 3

Model L-8 liquid level switch is provided with a continuous adjustable float buoyancy control to allow use in fluids with specific gravity down to 0.6. BUOYANCY OF FLOAT SWITCH WEIGHT OF FLOAT CONTINUOUS FORCE/BALANCE FLOAT SPRING ADJUSTMENT BEST ADJUSTMENT POINT (CENTERED) REMOVE COVER LEADSCREW ADJUST LEADSCREW SPRING POSITION WHEN DELIVERED MICROSWITCH SWITCH POINT ADJUSTMENT 1. Remove cover. 2. All units are delivered with the spring in the fully relaxed condition (A), which corresponds to the maximum specific fluid condition. ADJUSTING SPRING 3. Insert blade type screw driver in the slotted end of the adjusting screw and turn it in a clockwise direction. This extends the length of the adjusting spring, which in turn adjusts the float net effective buoyancy to respond to lower specific gravity fluids. P. 4 ULTRA RELIABLE SINCE 1956

SPECIFIC GRAVITY FLUIDS LOW MEDIUM SPRING EXTENSION HIGH Microswitch actuation point may be monitored during the adjustment procedure detailed in (2 and 3) above by an audible click or with an ohmmeter before connecting line power to the terminal strip, or by monitoring the voltage supplied to the load through the microswitch. ULTRA RELIABLE SINCE 1956 P. 5

L-8N (Series 65600) 1 STRAIN RELIEF NUT (1) 60127 2 GROMMET #A (OPTIONAL) (1) 10440 #AA (OPTIONAL) (1) 10441 #B (OPTIONAL) (1) 10442 #C (OPTIONAL) (1) 10443 3 COVER (MALE) (OPTIONAL) (1) 60125 4 COVER (FEMALE) (OPTIONAL) (1) 60126 5 SCREW (4) 109-S 6 MICROSWITCH (1) 20103 7 BRACKET (COMPLETE ASSEMBLY) (1) 65201 #A CROSS PIN (1) 65215 #B SPRING LEVER (1) 65216 8 TERMINALS (3) 706-T 9 SCREW (1) 133-S 10 SCREW (1) 116-S 11 NUT (2) 219-N 12 WASHER (2) 311-W 13 WASHER (2) 301-W 14 SCREW (2) 118-S 15 LEAD SCREW NUT (1) 65214 16 SPRING (1) 65202 17 SCREW (2) 123-S 18 O-RING (1) 65110 19 BODY (ASSEMBLY ONLY) (1) 65203 CLAMP RING (SONIC WELD) (1) 65102 20 BUSHING REDUCER (OPTIONAL) (1) 65204 BUSHING REDUCER (OPTIONAL) (1) 65205 21 FEED THRU SHAFT (ASSEMBLY ONLY) (1) 65103 A) SEAL SHAFT (1) 65104 B) DIAPHRAGM (1) 65105 C) DIAPHRAGM WASHER (1) 65106 D) PIVOT PIN (1) 65107 E) CROSS PIN (1) 65108 22 FLOAT SHAFT ARM #2-B (1) 65208 23 FLOAT (FORTRON) (1) 65601 24 FLOAT (POLYPROPYLENE) (OPTIONAL) (1) 65602 18 19 20 11 12 13 16 15 14 3 7 6 2 1 10 9 17 8 23 22 5 21 24 4 P. 6 ULTRA RELIABLE SINCE 1956

L-8R (Series 65800) 1 STRAIN RELIEF NUT (1) 65301 2 GROMMET #A (OPTIONAL) (1) 10440 #AA (OPTIONAL) (1) 10441 #B (OPTIONAL) (1) 10442 #C (OPTIONAL) (1) 10443 3 COVER (MALE) (OPTIONAL) (1) 65302 4 COVER (FEMALE) (OPTIONAL) (1) 65303 5 SCREW (4) 109-S 6 MICROSWITCH (1) 20103 7 BRACKET (COMPLETE ASSEMBLY) (1) 65201 #A CROSS PIN (1) 65215 #B SPRING LEVER (1) 65216 8 TERMINALS (3) 706-T 9 SCREW (1) 133-S 10 SCREW (1) 116-S 11 NUT (2) 219-N 12 WASHER (2) 311-W 13 WASHER (2) 301-W 14 SCREW (2) 118-S 15 LEAD SCREW NUT (1) 65214 16 SPRING (1) 65202 17 SCREW (2) 123-S 18 O-RING (1) 65110 19 BODY (ASSEMBLY ONLY) (1) 65304 CLAMP RING (SONIC WELD) (1) 65305 20 BUSHING REDUCER (OPTIONAL) (1) 65306 BUSHING REDUCER (OPTIONAL) (1) 65307 21 FEED THRU SHAFT (ASSEMBLY ONLY) (1) 65103 A) SEAL SHAFT (1) 65104 B) DIAPHRAGM (1) 65105 C) DIAPHRAGM WASHER (1) 65106 D) PIVOT PIN (1) 65107 E) CROSS PIN (1) 65108 22 FLOAT SHAFT ARM #2-B (1) 65208 23 FLOAT (FORTRON) (1) 65601 24 FLOAT (POLYPROPYLENE) (OPTIONAL) (1) 65602 18 19 20 11 12 13 16 15 14 3 7 6 2 1 10 9 17 8 23 22 5 21 24 4 ULTRA RELIABLE SINCE 1956 P. 7

L-8CR (Series 65900) 1 STRAIN RELIEF NUT (1) 60127 2 GROMMET #A (OPTIONAL) (1) 65701 #AA (OPTIONAL) (1) 65702 #B (OPTIONAL) (1) 65703 #C (OPTIONAL) (1) 65704 3 COVER (MALE) (OPTIONAL) (1) 65302 4 COVER (FEMALE) (OPTIONAL) (1) 65303 5 SCREW (4) 109-S 6 MICROSWITCH (1) 20103 7 BRACKET (COMPLETE ASSEMBLY) (1) 65201 #A CROSS PIN (1) 65215 #B SPRING LEVER (1) 65216 8 TERMINALS (3) 706-T 9 SCREW (1) 133-S 10 SCREW (1) 116-S 11 NUT (2) 219-N 12 WASHER (2) 311-W 13 WASHER (2) 301-W 14 SCREW (2) 118-S 15 LEAD SCREW NUT (1) 65214 16 SPRING (1) 65202 17 SCREW (2) 123-S 18 O-RING (1) 65110 19 BODY (ASSEMBLY ONLY) (1) 65304 CLAMP RING (SONIC WELD) (1) 65305 20 BUSHING REDUCER (OPTIONAL) (1) 65306 BUSHING REDUCER (OPTIONAL) (1) 65307 21 FEED THRU SHAFT (ASSEMBLY ONLY) (1) 65103 A) SEAL SHAFT (1) 65104 B) DIAPHRAGM (1) 65105 C) DIAPHRAGM WASHER (1) 65106 D) PIVOT PIN (1) 65107 E) CROSS PIN (1) 65108 22 FLOAT SHAFT ARM #2-B (1) 65708 23 FLOAT (FORTRON) (1) 65805 24 FLOAT (POLYPROPYLENE) (OPTIONAL) (1) 65602 18 19 20 11 12 13 16 15 14 3 7 6 2 1 10 9 17 8 23 22 5 21 24 4 P. 8 ULTRA RELIABLE SINCE 1956

CERTIFICATE OF CONFORMANCE All Harwil Corporation ( HARWIL ) products are manufactured using new materials and components. Our products meet the applicable performance and materials specifications indicated in our current Specifications Sheets and Parts List. HARWIL endeavors to obtain its materials and components from American Companies. DOMINANCE OF HARWIL LIMITED EXPRESS WARRANTY Each user MUST make appropriate analysis and tests to determine the suitability of the HARWIL product for the intended use prior to purchase. HARWIL warrants that all HARWIL products will be free from defects in material and workmanship for a period of one year from the date of original shipment. This Warranty shall be LIMITED to the replacement and reconditioning of our products and parts. HARWIL reserves the right and sole discretion to modify or change the composition, design and appearance of its products at anytime. THIS WARRANTY SHALL BE IN LIEU OF ALL WARRANTIES OF MERCHANTABILITY AND OF ALL WAR- RANTIES OF FITNESS FOR A PARTICULAR PURPOSE RELATING TO HARWIL PRODUCTS AND PARTS. BUYER S SOLE REMEDY SHALL BE REPLACEMENT OR RECONDITIONING AS SET FORTH HEREIN. HARWIL SHALL INCUR NO OBLIGATIONS HEREUNDER AND NO LIABILITY IN THE EVENT OF (1) BUYER NOT FULFILLING ITS RESPONSIBILITIES; INCLUDING AS SET FORTH HEREIN; (2) NEGLECT, ALTERATION OR IMPROPER PRODUCT USE, INCLUDING USE WITH NON-COMPATIBLE DEVICES OR CHEMICALS; OR (3) REPAIR BY ANOTHER COMPANY OR PERSON THAN HARWIL. ANY LAWSUIT RELATING TO THIS LIMITED EXPRESS WARRANTY MUST BE COMMENCED WITHIN ONE YEAR OF THE DATE THE LAWSUIT ACCRUES. HARWIL provides NO WARRANTY and ASSUMES NO RESPONSIBILITY for corrosive attack on any material, component or design features associated with any of its products. Corrosion resistance information listed in HARWIL specification sheets, information sheets and product brochures is solely for general background information. This information table has been compiled from literature published by various material suppliers and by equipment manufacturers who use these materials in their products. Inasmuch as these data are based on tests by entities over which HARWIL has no control, HARWIL DOES NOT GUARANTEE AND DOES NOT ACCEPT ANY RESPONSIBILITY FOR THE ACCURACY OF SUCH THIRD PARTY TESTING. When using the table, please remember that in any given case several factors such as concentration, temperature, degrees of agitation and presence of impurities influence the rate of corrosion. The information table is intended, in a general way, to rate materials for resistance to chemicals which contain their usual impurities and for types of equipment in common use. Ratings should be used only as a general tool to first approximation of your material requirements rather than as the final answer. WHEN IN DOUBT, TEST MATERIALS BEFORE INSTALLATION. AFTER INSTALLATION, FOLLOW UP WITH SCHEDULED PREVENTATIVE MAINTENANCE AND PERIODIC INSPECTION. ULTRA RELIABLE SINCE 1956 P. 9