In-line Twin Pump. Etaline Z PumpDrive 2/ Etaline Z PumpDrive 2 Eco. Type Series Booklet

Similar documents
Standardised Water Pump. Etanorm. Type Series Booklet

Etaprime B Type Series Booklet

Etaline MN. In-line Pumps

Self-priming Pump. Etaprime B. Type Series Booklet

Etanorm SYT Type Series Booklet

Standardised Water Pump. Etanorm. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Boiler Feed Booster Pump YNK. Type Series Booklet

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Etanorm GPV-D/CPV-D Etanorm GPV-W/CPV-W

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet

Designation. Accessories Drive

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

Closed-coupled Pump. Etachrom B. 50 Hz - 60 Hz. Type Series Booklet

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Waste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet

BOA-Compact EKB. Type Series Booklet

BOA-H Mat E Type Series Booklet

BOA-Compact. Type Series Booklet

Strainer BOA-S PN 6/16/25 DN Type Series Booklet

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

BOA-SuperCompact. Type Series Booklet

Non-return Valve BOA-R. PN 6/16 DN Flanged. Type Series Booklet

Movitec VCI Type Series Booklet

Data sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.

Thermal Oil / Hot Water Pump. Etanorm SYT. General Arrangement Drawings

BOA-Control IMS. Type Series Booklet

RDLO / RDLO V Type Series Booklet

3 Specification Magneta Smedegaard

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Norm-Centrifugal Pumps PN 10

Process Pump RPH. Type Series Booklet

High-pressure In-line Pump. Movitec. 50 Hz. Type Series

4 Specification Magneta Smedegaard twin pumps

TPED /4-S-A-F-A-BAQE 3X400 50HZ

Contents. Identification

RDLO / RDLO V Type Series Booklet

TP /2-A-F-A-BAQE 400D 50HZ

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

MegaCPK Type Series Booklet

Double Mechanical Seals

TPED /4-A-F-A-BQQE 3X400 50HZ

CONDA-VRC Type Series Booklet

SMARTRONIC AS-i. Type Series Booklet

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

VERTICAL IN-LINE PUMP

NB /438 A-F1-A-GQQE

High-pressure pumps Series HP45

TP /2-A-F-A-BQQE 400D 50HZ

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

NB80-160/161 A-F2-A-BQQE

TP /2-A-F-A-BQQE 400D 50HZ

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E:

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

TPE /2-S-A-F-A-BAQE 3X400 50HZ

ECOLINE GTC Type Series Booklet

TPE /4-A-F-A-BAQE 3X400 50HZ

NK40-160/172A1F2AE-SBAQE

CRE15-01 A-F-A-E-HQQE 1x HZ

NBE50-250/205 A-F2-A-BAQE

BOAX-B Mat E. Type Series Booklet

CRI10-14 A-FGJ-I-E-HQQE 3x400D 50 HZ

NBE40-125/139 AS-F2-A-BAQE

TP /4-A-F-A-BUBE 400Y 50HZ

SIE BV/ED EVS. SINGLE HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 et 60 Hz. operating limits SIE BV/ED

Vertical multi-stage pumps

Strainers BOA -S. PN 6/16/25 DN Flanged. Type Series Booklet

NB /263 AS-F2-A-BAQE

In-line Pump. Etaline. Installation/Operating Manual

High-pressure pumps Series HP49

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

Volute Casing Centrifugal Pumps of Inline Design Series NI

CRN15-09 A-P-G-V-HQQV 3x400/ HZ

AKG-A/AKGS-A. Type Series Booklet

CRE20-08 A-F-A-E-HQQE 3x HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

The e-nsc End Suction Pump Series

CR45-10 A-F-A-E-HQQE 3x400/ HZ

NK /310A2F1AE-SBAQE

CRN15-12 A-P-G-E-HQQE 3x400/ HZ

TP /2-A-F-A-BUBE 1X230 50HZ

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL

Transcription:

In-line Twin Pump Etaline Z PumpDrive 2/ Type Series Booklet

Legal information/copyright Type Series Booklet Etaline Z PumpDrive 2/ All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 02.03.2015

Contents Contents Heating / Air-conditioning / Ventilation...4... 4 Etaline Z PumpDrive 2 /... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Coating and preservation... 5 Product benefits... 5 Certifications... 5 Product information as per Regulation No. 547/2012 (for water pumps with a maximum shaft power of 150 kw) implementing "Ecodesign" Directive 2009/125/EC... 5 Acceptance tests / warranty... 6 Project planning information... 6 Programme overview / selection tables... 10 Pressure and temperature limits... 13 Materials... 14 Technical data of the pump set... 14 Technical data of the pump... 16 Selection charts... 16 Dimensions and connections... 18 Flange design... 22 Flange dimensions... 22 Typical installation positions... 23 Accessories... 24 Detailed designation... 25 PumpMeter... 27 General description... 27 Main applications... 27 Technical data... 27 Materials... 27 Product benefits... 27 Functions... 28 Design variants... 29 Electrical connections... 30 Dimensions... 30 3

Heating / Air-conditioning / Ventilation In-line Twin Pumps with Motor-mounted Variable Speed System Etaline Z PumpDrive 2 / Main applications Heating systems Air-conditioning systems Cooling circuits Water supply systems Service water supply systems Industrial recirculation systems Fluids handled Fluids not chemically or mechanically aggressive to the materials Table of fluids handled ( Page 10) Operating data Operating properties Characteristic Value Single-pump operation Parallel operation Flow rate Q [m 3 /h] 602.5 1095 Q [l/s] 167 304.5 Head H [m] 38.5 Fluid temperature T [ C] -30 to +140 Operating pressure p [bar] 16 1) Pressure and temperature limits ( Page 13) Designation Example: ETLZ 032-032-160 GG X AA 06 D 2 PD2E M Key to the designation Code Description ETLZ Pump type ETLZ Etaline Z 032 Nominal suction nozzle diameter [mm] 032 Nominal discharge nozzle diameter [mm] 160 Nominal impeller diameter [mm] G Pump casing material G Grey cast iron EN-GJL-250/A48CL35 G Impeller material G Grey cast iron EN-GJL-250/A48CL35 B Bronze CC480K-GS/B30 C90700 C Stainless steel 1.4408/A743CF8M X Design - Standard X Special design BT3D, BT3 A Casing cover A Conical seal chamber A Type of seal V Conical seal chamber with vent A Conical seal chamber 06 Seal code 06 Mechanical seal material U3BEGG (shaft units 25, 35) 09 Mechanical seal material U3U3VGG 10 Mechanical seal material Q1Q1X4GG 11 Mechanical seal material BQ1EGG 22 Mechanical seal material AQ1EGG (shaft unit 55) D Scope of supply A Pump without motor D Pump with motor 2 Shaft unit 2 Shaft unit 25 3 Shaft unit 35 5 Shaft unit 55 PD2E Drive type series M M PumpMeter Further information on the designation ( Page 25) Design details Design In-line twin pump in closed-coupled design Single-stage Horizontal/vertical installation Rigid connection between pump and motor Pump casing Drive Radially split volute casing KSB SuPremE motor: Surface-cooled KSB SuPremE motor, IEC-compatible, magnetless synchronous reluctance motor (PumpDrive required) 1) The sum of inlet pressure and shut-off head must not exceed the value indicated. 4 Etaline Z PumpDrive 2 /

Frequency 50/60 Hz (PumpDrive input) Voltage 380/480 V (PumpDrive input) Type of construction IM V15 IP55 enclosure Mode of operation: continuous operation S1 Thermal class F with temperature sensor; 3 PTC thermistors Efficiency class IE4 in compliance with IEC/CD 60034-30 Ed. 2 KSB SuPremE B1: With terminal box for connection to wall- or cabinetmounted PumpDrive S, PumpDrive 2 or PumpDrive R KSB SuPremE B2: Equipped for being fitted with a motor-mounted PumpDrive 2 Shaft centreline height 71 mm - 225 mm Rated power 0.55 kw - 45 kw Types of construction Type of construction Flange type 2) With foot Shaft centreline height [mm] Mounting arrangement IM... None 71-225 B3 3), B6, B7, B8, V5, V6 Flange with 71-225 V15 3), V35, B35 clearance holes (FF) - 71-160 V1 3), V3, B5 Flange with tapped holes (FT) Asynchronous motor: - - - 132 V18 3), B14, V19 KSB/Siemens surface-cooled IEC frame three-phase squirrel-cage motor Winding 220-240 V / 380-420 V 2.20 kw Winding 380-420 V / 660-725 V 3.00 kw Type of construction IM V1 4.00 kw Type of construction IM V1 5.50 kw IP55 enclosure Mode of operation: continuous operation S1 Thermal class F with temperature sensor; 3 PTC thermistors Efficiency class IE2 or IE3 PumpDrive: Mains voltage: 3 ~ 380 V AC -10 % to 480 V AC +10 % Mains frequency 50-60 Hz ± 2 % IP55 enclosure Shaft seal Standardised mechanical seal to EN 12756 Shaft equipped with a replaceable shaft sleeve in the shaft seal area Impeller type Closed radial impeller Bearings Radial ball bearings in the motor housing Grease lubrication Twin pump Two separate centrifugal pump hydraulic systems in one pump casing with a spring-loaded changeover flap located in the discharge nozzle. On twin pumps of sizes DN 32 to 80, the changeover flap housing is made of Rilsan. On sizes from DN 100 up to and including DN 200, the changeover flap housing is made of bronze. The flaps, springs and stems etc. are made of chrome steel. Two integrated vent valves ensure that the mechanical seal chamber can be vented manually. Single-pump operation (one pump on stand-by) and parallel operation (additional pump start-up in case of peak load) can be selected as operating modes. The M12 module (accessory) enables redundant dualpump operation without the need for a higher-level controller. Coating and preservation Coating and preservation to KSB standard Product benefits Maximum energy efficiency through demand-driven operation in combination with KSB SuPremE IE4 motor PumpDrive perfectly matched to pump and motor by default factory parameter settings Space-saving owing to motor-mounted variable speed system up to 45 kw Pump operation made fully transparent with PumpMeter Certifications This product is subject to the provisions of the "Ecodesign" Directive 2009/125/EC and meets, as a minimum, the ecodesign requirements established in 2013 for water pumps with a maximum nominal shaft power of 150 kw as per Regulation (EU) No. 547/2012. Product information as per Regulation No. 547/2012 (for water pumps with a maximum shaft power of 150 kw) implementing "Ecodesign" Directive 2009/125/EC Minimum efficiency index: see data sheet The benchmark for the most efficient water pumps is MEI 0.70. Year of construction: see data sheet Manufacturer s name or trade mark, commercial registration number and place of manufacture: see data sheet or order documentation Product s type and size identificator: see data sheet Hydraulic pump efficiency (%) with trimmed impeller: see data sheet Pump performance curves, including efficiency characteristics: see documented characteristic curve 2) Designations to EN 50347 3) Standard mounting arrangement Etaline Z PumpDrive 2 / 5

The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with full impeller diameter. Trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. Operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system. Information relevant for disassembly, recycling or disposal at end of life: see installation/operating manual Information on benchmark efficiency or benchmark efficiency graph for MEI = 0.7 (0.4) for the pump based on the model shown in the Figure are available at: http:// www.europump.org/efficiencycharts Acceptance tests / warranty The following acceptance tests may be performed at a surcharge: Materials testing Test report 2.2 Final inspection Inspection certificate 3.1 to EN 10204 Hydraulic test The duty point of each pump is guaranteed according to ISO 9906/2B or ISO 9906/3B. NPSH test Other inspections/tests on request Warranties Warranties are given within the scope of the valid delivery conditions. Project planning information Selecting power/connection cables Unshielded cables can be used as power cables. The power cables must be designed with a cross-section suitable for the nominal mains current. If a mains contactor is used in the power cable (before the frequency inverter), this must be configured for an AC1 duty rating; the rated current values of the frequency inverters used are added and the result is increased by 15 %. 6 Etaline Z PumpDrive 2 /

Power/connection cable properties Size Power Cable gland for Nominal current 4) Mains power cable Sensor cable Motor cable PTC thermistor, mains [kw] [A] [mm²] A.. 000K37.. 0,37 M25 M16 M25 M16 1,4 2,5 1,5.. 000K55.. 0,55 2,0.. 000K75.. 0,75 2,7..001K10.. 1,1 3,7 B.. 001K50.. 1,5 M25 M16 M25 M16 5,2 2,5.. 002K20.. 2,2 6,3.. 003K00.. 3 8,4.. 004K00.. 4 10,4 1 2 3 Maximum core cross-section Cable cross-section KSB motor cable Structure of electric cable 1 Wire end sleeve 2 Core 3 Cable Cable cross-section, control terminals Control terminal Core cross-section [mm²] Cable diameter 5) Rigid cores Flexible cores Flexible cores with wire end sleeves [mm] Terminal strip A, B, C 0,2-1,5 0,2-1,0 0,25-0,75 M12: 3,5-7,0 M16: 5,0-10,0 Length of motor connection cable If the frequency inverter is not mounted on the motor to be controlled, longer motor connection cables may be required. The stray capacitance of the connection cables may result in high-frequency discharge currents flowing to ground. The sum of the discharge currents and motor current may exceed the output-side rated current of the frequency inverter. This will activate the frequency inverter's protection equipment and the motor will be stopped. The following motor connection cables are recommended depending on the power range: Length of motor connection cable Power range [kw] Maximum cable length [m] Stray capacitance [nf] 7.5 (Class B) 5 5 Output filter If longer connection cables than those listed above are required or the connection cable's stray capacitance value exceeds the above values, we recommend installing a suitable output filter between the frequency inverter and the motor to be controlled. These filters reduce the voltage ramp-up time of the frequency inverter output voltages and limit their peaks. Electrical protection device Back-up fuses Provide three fast-acting fuses in the mains power supply line to the frequency inverter. The fuse size must be suitable for the nominal mains current supplied to the frequency inverter. 4) Observe the information on the use of line chokes provided in the Accessories and Optional Equipment section. 5) Impairment of protection provided by enclosure when cable diameters other than those specified are used. Etaline Z PumpDrive 2 / 7

R L PE R' Heating / Air-conditioning / Ventilation Motor protection switch Separate motor protection is not required because the frequency inverter has its own safety devices (e.g. electronic overcurrent trip). Set any motor protection switches to a minimum of 1.4 times the nominal motor current. Residual current device If fixed connections and appropriate supplementary earthing are used (cf. DIN VDE 0160), RCDs are not mandatory for frequency inverters. If residual current devices (RCDs) are used, three-phase frequency inverters in accordance with DIN VDE 0160 must be connected via universal AC/DC-sensitive residual current devices (RCDs) as potential direct-current components may cause standard AC-sensitive RCDs to either fail to respond or respond erroneously. Residual current devices to be selected Size A and B Rated current 150 ma If you use a long shielded cable for the mains/motor connection, the residual-current monitoring device may be triggered by the discharge current that flows to earth (triggered by the carrier frequency). Remedies: Replace the RCD (residual current device) or lower the response limit. Information on electromagnetic compatibility Electromagnetic interference from other electrical devices can affect the frequency inverter. Interference can also be generated by the frequency inverter itself, however. Interference emitted by the frequency inverter is generally conducted through the motor connection cables. The following measures are proposed for RFI suppression: Shielded motor connection cables for line lengths > 70 cm (especially recommended for frequency inverters with low power ratings) Made from a single piece of formed metal cable ducting with a minimum coverage of 80 % (if shielded connection cables cannot be used) Use different earth bus bars for the control cable and mains power/motor connection cables. The shield on the power cable/connection cable must consist of a single piece and be earthed at both ends either just on the appropriate earth terminal or on the earth bus bar (do not connect it to the earth bus bar in the control cabinet). The shielded cable ensures that the high-frequency current, which normally flows as a discharge current from the motor housing to earth or between the individual conductors, flows through the shielding. The shield for the control cable (connection on the frequency inverter side only) also serves as protection against radiated emission. If using shielded cables, use a wide contact face for the different earth connections to ensure greater interference immunity. In applications with long shielded motor cables, provide additional reactive resistors or output filters to compensate the capacitive stray current to earth and reduce the rate of voltage rise on the motor. These measures help reduce radio interference further. Using just ferrite rings or reactive resistors does not ensure compliance with the limit values defined in the EMC directive. NOTE! If you are using shielded cables that are longer than 10 m, check the stray capacitance to ensure that the diffusion between the phases or to earth is not excessive, which could cause the frequency inverter to stop. Route control cable and mains power/motor connection cables in separate cable ducts. When routing the control cable observe a minimum distance of 0.3 metres between the control cable and the mains power/ motor connection cables. If you cannot avoid crossing control and mains power/motor connection cables, you should cross them at 90 degrees to each other. Earth connection The frequency inverter must be properly earthed. To ensure greater interference immunity, a wide contact face is required for the different earth connections. In the case of cabinet mounting, use two separate copper earth bus bars (mains power supply/motor connection and control connection bar) with a suitable size and cross-section for earthing the frequency inverter. All the earth connections are connected to these. The bars are connected to the earthing system at one point only. The control cabinet is then earthed via the mains earthing system. Output filter L1 L2 L3 Installing the line choke and output filter Transformer Line choke C X C Y R L C X C Y PE R' Output filter Motor The maximum cable lengths must be observed in order to meet RFI suppression requirements to DIN 55011. Output filters are required if the maximum cable lengths are exceeded. IGBT switchgear is suitable for achieving high power. This, however, can result in faults due to the rapid switching operations, particularly if you are using long motor/drive control cables: Electromagnetic interference Damage to the motor winding insulation Voltage peaks due to high stray capacitance on the cable connections Damage to the short-circuit protective devices Output filters can be used to remedy these situations: When a filter is used, the peak voltage (V peak ) and its rate of rise (dv/dt) can be reduced. The peak voltages can also be seen as a function of the stray capacitance induced by the power circuits. The stray capacitance for frequency inverter sizes A, B, C and D must be below 5 nf. If long cables are required for installation reasons, for example, for wall or control cabinet mounting, and the stray capacitance value exceeds the maximum permissible value, a dv/dt limiting filter or sine filter must be installed. Connect the filter at the output of the 8 Etaline Z PumpDrive 2 /

frequency inverter. The filter protects the frequency inverter against excessive discharge currents and prevents the protective equipment from being deactivated as a result. Line chokes The line input currents indicated in the project planning information are for orientation purposes only; they refer to operation at nominal rating. These currents may vary depending on the actual line impedance. In low-impedance mains, higher currents may occur. To limit the line input current, external line chokes can be used alongside the integrated line chokes (in the power range up to and including 45 kw). Line chokes also reduce mains feedback and improve the power factor. The scope of DIN EN 61000-3-2 must be heeded. Line chokes connected in series in the line to the consumer ensure that the typical requirement of a short circuit voltage of 4 % to the mains is complied with and reduce the mains feedback (in the form of harmonics) that may cause problems in the public power supply mains. Another benefit is the limitation of the charge currents of the DC link capacitors, which will increase the service life of these primary components. Line chokes also reduce the reactive power component and thus contribute to a significantly improved effective power factor. The scope of DIN 1000-3-2 must be heeded. Three-phase (3~) line choke: IP 00 enclosure Thermal class F Max. ambient temperature 40 C Line chokes (overview) Size Power Line choke inductance l n Nominal current I Nominal motor current Maximum current I sat L B H Mat. No. Weight [kw] [mh] [A] [mm] [mm] [mm] [kg] A..000K55.. 0,55 kw 2,0 11 1,5 I n 150 85 150 01093105 3.6..000K75.. 0,75 kw..001k10.. 1,1 kw..001k50.. 1,5 kw..002k20.. 2,2 kw..003k00.. 3 kw B..004K00.. 4 kw..005k50.. 5,5 kw 1,1 28 1,5 I n 180 120 178 01093106 8.3..007K50.. 7,5 kw C..011K00.. 11 kw..015k00.. 15 kw 0,5 51 1,5 I n 180 135 178 01093107 10.5..018K50.. 18,5 kw..022k00.. 22 kw D..030K00.. 30 kw 0,1 100 1,5 I n 180 180 180 01093108 10.8..037K00.. 37 kw..045k00.. 45 kw Etaline Z PumpDrive 2 / 9

Programme overview / selection tables Overview of fluids handled Table of fluids handled and associated material combinations = standard Fluid handled Casing/impeller materials Shaft seal mechanical seal Comments Water Application limit Temperature Grey cast iron/ grey cast iron Grey cast iron/ stainless steel Grey cast iron/ bronze U3BEGG (SU 25, 35) AQ1EGG (SU 55) Q1Q1EGG U3U3VGG Q1Q1X4GG [ C] G GC GB 6 22 7 6) 9 10 11 Service water 110 CrNiMo cast steel can be used Fire-fighting water 7) 60 Contact KSB for supply to VdS guideline. Heating water 8) 110 If used as a circulating pump to DIN 4752: p maximum 10 bar Heating water 140 Heating water 110 Condensate 110 Cooling water 60 Open circuit: GB 10 required (without antifreeze) Cooling water ph 7.5-30 Open loop: use GB (with antifreeze 9) ) 60 Cooling water ph 7.5 60 Open loop: use GB (with antifreeze 9) ) 110 Slightly contaminated water 60 Pure water 10) 60 Raw water 60 Swimming pool water (fresh water) Swimming pool water 11) : filtration Swimming pool water 11) : water features; without turbulences and/or air content 60 Also applies to requirements as per DIN 19643 BQ1EGG 40 Variant GB Shaft C45+N, shaft sleeve CrNiMo steel, nut A4/AISI 316, key A2, casing wear ring (suction and discharge side) grey cast iron JL 1040/ CI 40 Variant GB Shaft C45+N, shaft sleeve CrNiMo steel, nut A4/ AISI 316, key A2, casing wear ring (suction and discharge side) CC495K- GS Dam water 60 If solids are contained, contact KSB. Drinking water 12) 60 Partly desalinated water 120 Fully desalinated water as boiler feed water Refrigerants, cooling brines Cooling brine; inorganic, ph value > 7.5, inhibited Water with antifreeze, ph value 7.5 Water with antifreeze, ph value 7.5 Oils/emulsions 110-30 25-30 60 60 110 6) Not for Etaline Z 7) General evaluation criteria for results of water analysis: ph value 7; chlorides content (Cl) 250 mg/kg. Chlorine (Cl2) 0.6 mg/kg. 8) Treatment to VdTÜV 1466; additional requirement: O2 < 0.02 mg/l 9) Antifreeze on ethylene glycol basis with inhibitors. Content: >20 % to 50 % (e.g. Antifrogen N) 10) No ultra-pure water! Conductivity at 25 C: 800 μs/cm, neutral with regard to chemical corrosion 11) For France, observe the applicable rules as per ministerial order dated 18 January 2002. 12) For France, ACS approval is required. 10 Etaline Z PumpDrive 2 /

Fluid handled Casing/impeller materials Shaft seal mechanical seal Comments Application limit Temperature Grey cast iron/ grey cast iron Grey cast iron/ stainless steel Grey cast iron/ bronze U3BEGG (SU 25, 35) AQ1EGG (SU 55) Q1Q1EGG U3U3VGG Q1Q1X4GG [ C] G GC GB 6 22 7 6) 9 10 11 Drilling/grinding emulsion 60 Oil-water emulsion 60 BQ1EGG Functional overview Functional overview Functions/firmware PumpDrive 2 Eco 13) PumpDrive 2 Protective functions Thermal motor protection Measuring and monitoring mains voltage Phase failure on motor side Short-circuit monitoring, motor side Dynamic overload protection by speed limitation (i 2 t control) Suppression of resonant frequencies Cable integrity monitoring (live zero) Protection against dry running and hydraulic blockage (sensorless via - learning function) Dry running protection (external control signal) Operating point estimation and characteristic curve control Open-loop control Open-loop control mode Closed-loop control Closed-loop control mode via integrated PID controller Pressure/differential pressure control ( p const) Pressure/differential pressure control with dynamic pressure compensation ( p var) Flow rate control - Sensorless differential pressure control ( p const) Sensorless differential pressure control with dynamic pressure compensation ( p var) Level control - Temperature control Operation and monitoring Display Display of measured values such as pressure, head, speed, electric power, motor voltage, motor current, torque Fault history Operating hours counter Fault reporting via relay PumpDrive functions Programmable start and stop ramps Field-oriented control (vector control), V/f control Configurable motor control method (asynchronous motor, KSB SuPremE) Automatic Motor Adaptation (AMA) Manual-0-Automatic mode External OFF External minimum speed Sleep mode (stand-by mode) 6) Not for Etaline Z 13) Some functions can only be parameterised or displayed using the Service Tool (see operating manual). Etaline Z PumpDrive 2 / 11

Functions/firmware PumpDrive 2 Eco 13) PumpDrive 2 Pump functions PumpMeter bus connection (single pump) Operation Control panel Commissioning wizard - Favourites list - Service interface Protective functions Sensorless protection against dry running and hydraulic blockage Dry running of the pump is detected and the pump set is stopped before components are damaged. Hydraulic blockage is also detected and initially a warning is displayed. If the blockage persists for a prolonged period of time, the pump set is stopped. These protective functions do not require sensors. They are based on an automatic learning function which needs to be run once during commissioning. Dynamic overload protection by speed limitation (I 2 t control) The frequency inverter is equipped with current sensors that record and limit the motor current. When the defined load or temperature limit is reached, the speed is lowered in order to reduce the power (I 2 t control). The frequency inverter then no longer operates in closed-loop control mode but maintains the operative function at a lower speed. Characteristic curve control The frequency inverter indicates continuous operation outside the permissible range, such as extremely low flow or extreme overload. The frequency inverter monitors the current operating point on the basis of the motor input power and the speed. In the case of extremely low flow or overload a message is output and, depending on the settings, the pump set is stopped as required. Open-loop and closed-loop control Sensorless differential pressure control for single-pump configurations The configurable differential pressure is kept almost constant over a broad operating range without the need for sensors. This can also be achieved using the dynamic pressure compensation function. The speed is adjusted as a function of the power input so that the required differential pressure is maintained. Dynamic pressure/differential pressure compensation The dynamic pressure/differential pressure compensation function compensates for pipe friction losses, which need to be considered if the pressure/differential pressure sensor is installed close to the pump or if sensorless differential pressure control is used. This ensures a virtually constant pressure/ differential pressure at the consumer (e.g. heating) regardless of the flow. The dynamic pressure compensation function requires signals from two pressure sensors or one differential pressure sensor. Alternatively, sensorless dynamic differential pressure compensation can be used. The differential pressure setpoint is increased as a function of the (estimated or measured) flow rate or the speed. Operation and monitoring Display Various physical data, such as the pressure, flow rate, speed, motor voltage, motor current, electric power, torque and others, can be displayed using the control panel or the service software. Message history The last 100 messages of the frequency inverter can be viewed. All messages are provided with a time stamp (real-time clock). Statistics function The frequency inverter generates utilisation statistics on the operating hours to date, runtime and number of start-ups. Frequency inverter functions Motor control method The frequency inverter's motor control method can be set for either an asynchronous motor or the KSB SuPremE motor. Automatic motor adaptation Automatic motor adaptation (AMA) is a method for measuring the electric parameters of the motor with the motor at a standstill. The frequency inverter's motor control method is optimised to ensure optimum motor performance and efficiency. Stand-by mode (sleep mode) Sleep mode allows the single or multiple pump system to be started and stopped in line with demand. If sleep mode is activated, the frequency inverter stops the pump in the case of low flow rates, i.e. when the low flow limit or stop speed is reached. In pressure control applications, an accumulator can be filled during brief operation with an increased setpoint prior to stopping. If a drop in pressure and, thus, a flow rate requirement are detected, the pump restarts. Pump functions Direct connection of PumpMeter In single-pump configurations, PumpMeter can be connected to the frequency inverter via the Modbus interface using the M12 connector. Once they are connected, the frequency inverter and PumpMeter can automatically exchange all the data required for initialisation (pump characteristic curve, sensor data, etc.). This enables easy and straightforward commissioning/start-up, even in retrofit applications. Dual pump operation Dual pump operation serves to control two pumps of identical design. Two operating modes can be set: In "1 pump" operating mode, the dual pump system is designed to achieve the setpoint with one pump operating at rated values (2 x 100 %). 13) Some functions can only be parameterised or displayed using the Service Tool (see operating manual). 12 Etaline Z PumpDrive 2 /

In "2 pumps" operating mode, the dual pump system is designed to achieve the setpoint with both pumps operating at rated values (2 x 50 %). Design variants for dual pump operation Basic / Basic with DPM module per PumpDrive 14) PDBB (with PumpMeter) Advanced / Basic PDAB (with PumpMeter) Advanced / Advanced PDAA (with PumpMeter ) Operating mode 2 x 100 % Operating mode 2 x 50 % Pump changeover 24 h Redundancy - 2 PumpDrive Basic PDBB (with PumpMeter): The dual pump module (DPM) set of accessories is available for controlling redundant variable speed twin pumps (e.g. Etaline Z PumpDrive) or two identical variable speed pumps operating in parallel. The dual pump module (DPM) incorporates all functions required for operation of redundant dual pumps or two identical variable speed pumps. The dual pump module (DPM) can only be used in combination with PumpDrive Basic and the standard control panel. The DPM module cannot be used in combination with the blanking plate or the graphical control panel. 2 PumpDrive Advanced PDAA (with PumpMeter): Redundant operation is also possible with a configuration of 2 PumpDrive Advanced. 1 PumpDrive Advanced and 1 PumpDrive Basic PDAB (with PumpMeter): If PumpDrive Advanced (Master) fails, PumpDrive Basic assumes a default status (for example operation at maximum speed), which can be set during commissioning. Control is no longer possible if PumpDrive Advanced fails. Pressure and temperature limits Pressure and temperature limits of the pump Pressure and temperature limits of the pump Material variant Fluid temperature [ C] 15)16) Test pressure [bar] 17) G, GC,GB -30 to +140 Up to 21 14) Only with standard control panel 15) For hot water heating systems to DIN 4752, Section 4.5, application limits must be observed. 16) For fluid temperatures >140 C use Etanorm SYT. 17) The casing components are checked for leakage by means of internal pressure tests to ZN 1650 with water. Etaline Z PumpDrive 2 / 13

Pressure and temperature limits of pump with flanges to EN 1092-2 and drilled to ASME B 16.1 18) p 2 [bar] DN 32-200 16 JL1040/A48 CL 35B 14 12 10 8-30 20 70 T [ C] 120 140 Pressure and temperature limits of the pump Materials Overview of materials available for Etaline Part No. Description Material variant G GB GC 102 Volute casing Grey cast iron EN-GJL-250/ A 48 CL 35B 161 Casing cover, conical Grey cast iron EN-GJL-250/ A 48 CL 35B 210 Shaft Tempered steel C45+N Stainless steel 1.4571 (optional) 230 Impeller Grey cast iron EN-GJL-250/ A 48 CL 35B - - Bronze CC480K-GS/ B30 C90700 - - Stainless steel 1.4408/ A743 Gr CF8 M 19) - - 341 Drive lantern Grey cast iron EN-GJL-250/ A 48 CL 35B 400 Sealing elements DPAF, asbestos-free 502.01 Casing wear ring, suction side Grey cast iron EN-GJL-250/ CI Bronze CC480K-GS - - 502.02 Casing wear ring, discharge side Grey cast iron EN-GJL-250/ CI Bronze CC480K-GS - - 523 Shaft sleeve Stainless steel (CrNiMo steel) 902 Studs Steel 8.8 903 Plug Steel 920 Nut 8+A2A/ 8+B633 SC1 TP3 920.95 Impeller nut Stainless steel (CrNiMo steel) Steel 8 - Technical data of the pump set n = 1450 rpm Size KSB SuPremE motor [kg] Size P2 [kw] 400 V [A] 20) 032-032-160 080M 0,55 1,6 87,9 032-032-160 080M 0,75 2,1 91,9 032-032-160 090S 1,10 3,0 95,9 032-032-160 090L 1,50 4,0 101,9 032-032-200 080M 0,55 1,6 108,7 032-032-200 080M 0,75 2,1 112,7 032-032-200 090S 1,10 3,0 116,8 032-032-200 090L 1,50 4,0 122,8 032-032-200 100L 2,20 5,7 142,5 Size KSB SuPremE motor [kg] Size P2 [kw] 400 V [A] 032-032-200 100L 3,00 7,8 142,5 032-032-200 112M 4,00 9,6 166,5 040-040-160 080M 0,55 1,6 89,4 040-040-160 080M 0,75 2,1 93,4 040-040-160 090S 1,10 3,0 97,4 040-040-160 090L 1,50 4,0 103,4 040-040-250 080M 0,55 1,6 127,9 040-040-250 080M 0,75 2,1 131,9 040-040-250 090S 1,10 3,0 136,0 040-040-250 090L 1,50 4,0 142,0 040-040-250 100L 2,20 5,7 161,7 040-040-250 100L 3,00 7,8 171,7 040-040-250 112M 4,00 9,6 185,7 040-040-250 132S 5,50 13,5 238,7 18) Not valid for sizes 125-125-200 and 125-125-250 19) Size Etaline GC 125-125-250 not available in Europe. 20) Basis: Etaline PumpDrive 2 14 Etaline Z PumpDrive 2 /

Size KSB SuPremE motor [kg] Size P2 [kw] 400 V [A] 20) 040-040-250 132M 7,50 17,6 252,7 050-050-160 080M 0,55 1,6 95,5 050-050-160 080M 0,75 2,1 99,5 050-050-160 090S 1,10 3,0 103,6 050-050-160 090L 1,50 4,0 109,6 050-050-160 100L 2,20 5,7 129,3 050-050-160 100L 3,00 7,8 139,3 050-050-160 112M 4,00 9,6 153,3 050-050-250 090S 1,10 3,0 138,9 050-050-250 090L 1,50 4,0 144,9 050-050-250 100L 2,20 5,7 164,6 050-050-250 100L 3,00 7,8 174,6 050-050-250 112M 4,00 9,6 188,6 050-050-250 132S 5,50 13,5 241,6 050-050-250 132M 7,50 17,6 255,6 050-050-250 160M 11,00 24,2 302,0 065-065-160 080M 0,55 1,6 103,1 065-065-160 080M 0,75 2,1 107,1 065-065-160 090S 1,10 3,0 111,2 065-065-160 090L 1,50 4,0 117,2 065-065-160 100L 2,20 5,7 136,9 065-065-160 100L 3,00 7,8 146,9 065-065-160 112M 4,00 9,6 160,9 065-065-250 090L 1,50 4,0 158,2 065-065-250 100L 2,20 5,7 177,9 065-065-250 100L 3,00 7,8 187,9 065-065-250 112M 4,00 9,6 201,9 065-065-250 132S 5,50 13,5 254,9 065-065-250 132M 7,50 17,6 268,9 080-080-160 080M 0,55 1,6 110,9 080-080-160 080M 0,75 2,1 114,9 080-080-160 090S 1,10 3,0 119,0 080-080-160 090L 1,50 4,0 125,0 080-080-160 100L 2,20 5,7 144,6 080-080-160 100L 3,00 7,8 154,6 080-080-160 112M 4,00 9,6 168,6 080-080-160 132S 5,50 13,5 221,7 080-080-250 100L 2,20 5,7 203,7 080-080-250 100L 3,00 7,8 213,7 080-080-250 112M 4,00 9,6 227,7 080-080-250 132S 5,50 13,5 279,7 080-080-250 132M 7,50 17,6 293,7 100-100-200 100L 2,20 5,7 237,1 100-100-200 100L 3,00 7,8 247,1 100-100-200 112M 4,00 9,6 261,1 100-100-200 132S 5,50 13,5 313,1 100-100-200 132M 7,50 17,6 327,1 100-100-200 160M 11,00 24,2 373,5 100-100-200 160L 15,00 33,0 423,5 100-100-200 180M 18,50 42,0 561,5 100-100-250 112M 4,00 9,6 289,9 100-100-250 132S 5,50 13,5 341,9 100-100-250 132M 7,50 17,6 355,9 100-100-250 160M 11,00 24,2 402,3 100-100-250 160L 15,00 33,0 452,3 100-100-250 180M 18,50 42,0 590,4 100-100-250 180L 22,00 48,5 638,4 100-100-250 200L 30,00 65,4 775,0 125-125-200 100L 2,20 5,7 253,6 Size KSB SuPremE motor [kg] Size P2 [kw] 400 V [A] 125-125-200 100L 3,00 7,8 263,6 125-125-200 112M 4,00 9,6 277,6 125-125-200 132S 5,50 13,5 329,6 125-125-200 132M 7,50 17,6 343,6 125-125-200 160M 11,00 24,2 390,0 125-125-200 160L 15,00 33,0 440,0 125-125-200 180M 18,50 42,0 578,0 125-125-200 180L 22,00 48,5 626,0 125-125-250 112M 4,00 9,6 306,8 125-125-250 132S 5,50 13,5 358,8 125-125-250 132M 7,50 17,6 372,8 125-125-250 160M 11,00 24,2 419,2 125-125-250 160L 15,00 33,0 469,2 125-125-250 180M 18,50 42,0 607,2 125-125-250 180L 22,00 48,5 655,2 150-150-250 132M 7,50 17,6 434,7 150-150-250 160M 11,00 24,2 481,2 150-150-250 160L 15,00 33,0 531,2 150-150-250 180M 18,50 42,0 669,2 150-150-250 180L 22,00 48,5 717,2 150-150-250 200L 30,00 65,4 853,8 150-150-250 225S 37,00 80,9 1127,8 150-150-250 225M 45,00 99,3 1228,6 200-200-250 160M 11,00 24,2 603,0 200-200-250 160L 15,00 33,0 653,0 200-200-250 180M 18,50 42,0 791,0 200-200-250 180L 22,00 48,5 839,0 200-200-250 200L 30,00 65,4 975,6 200-200-250 225S 37,00 80,9 1249,6 200-200-250 225M 45,00 99,3 1350,4 200-200-315 200L 30,00 65,4 1067,1 200-200-315 225S 37,00 80,9 1340,8 200-200-315 225M 45,00 99,3 1441,6 20) Basis: Etaline PumpDrive 2 Etaline Z PumpDrive 2 / 15

Technical data of the pump Technical data of an Etaline Z pump Pump size Shaft unit Impeller Speed limit Impeller outlet width Impeller inlet diameter Impeller diameter Maximum Minimum Maximum Minimum [mm] [mm] [mm] [mm] [rpm] [rpm] 032-032-160 WS_25 5,7 52,7 170 112 4200 800 032-032-200 WS_25 5,6 54,0 204 165 3800 800 040-040-160 WS_25 8,5 60,6 174 136 4200 800 040-040-250 WS_25 7,5 62,6 261 197 3000 800 050-050-160 WS_25 13,0 70,0 174 120 4200 800 050-050-250 WS_25 8,4 74,1 260 198 3000 800 065-065-160 WS_25 16,9 86,9 174 108 4200 800 065-065-250 WS_25 10,5 84,0 260 196 3000 800 080-080-160 WS_25 21,0 92,0 174 132 3900 800 080-080-250 WS_35 15,1 101,0 260 190 2100 800 100-100-200 WS_35 24,5 115,0 219 178 2100 800 100-100-250 WS_35 19,0 115,0 269 215 2100 800 125-125-200 WS_35 32,5 142,0 219 179 3300 800 125-125-250 WS_35 27,0 145,0 269 210 2100 800 150-150-250 WS_35 37,0 162,4 269 218 2000 800 200-200-250 WS_35 48,8 191,0 269 220 1800 800 200-200-315 WS_55 39,7 191,5 334 264 1700 800 Selection charts Etaline Z, n = 1450 rpm (single-pump operation) 5 US.gpm 10 20 30 40 50 100 200 300 400 500 1000 2000 3000 40 4 5 IM.gpm 10 20 30 40 50 100 200 300 400 500 1000 2000 30 100 200-200-315 20 100-100-250 125-125-250 50 65-65-250 150-150-250 40 10 32-32-200 40-40-250 50-50-250 80-80-250 100-100-200 200-200-250 30 20 5 4 3 50-50-160 40-40-160 65-65-160 80-80-160 125-125-200 10 2 32-32-160 ft H [m] 5 4 1 1 Q[m³/h] 2 3 4 5 10 20 30 40 50 100 200 300 400 500 700 0.3 0.4 0.5 l/s 1 2 3 4 5 10 20 30 40 50 100 16 Etaline Z PumpDrive 2 /

Etaline Z, n = 1450 rpm (parallel operation) 5 US.gpm 10 20 30 40 50 100 200 300 400 500 1000 2000 3000 40005000 40 4 5 IM.gpm 10 20 30 40 50 100 200 300 400 500 1000 2000 3000 40005000 30 100 20 200-200-315 10 40-40-250 65-65-250 80-80-250 100-100-250 150-150-250 125-125-250 200-200-250 50 40 30 32-32-200 50-50-250 100-100-200 125-125-200 20 5 4 80-80-160 65-65-160 50-50-160 3 40-40-160 10 2 32-32-160 ft H [m] 5 4 1 1 Q[m³/h] 2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 2000 0.3 0.4 0.5 l/s 1 2 3 4 5 10 20 30 40 50 100 200 300 400 500 Etaline Z PumpDrive 2 / 17

Dimensions and connections Connections Connections Connection types Connection Description Configuration Position 1M Pressure gauge connection Drilled and closed, or pressure sensor for PumpMeter (if selected) Suction and discharge flanges 5B.1, 5B.2 Vent connection for the mechanical Plugged with vent plug Casing cover seal chamber 6B, 6B.1, 6B.2 Fluid drain Drilled and closed Volute casing 6D, 6D.1, 6D.2 Fluid priming and venting Drilled and closed Volute casing Connection 21) [mm] Size 1M, 6B, 6D 5B 32-32-160 Rc 1 / 4 G 1 / 4 32-32-200 Rc 1 / 4 G 1 / 4 40-40-160 Rc 1 / 4 G 1 / 4 40-40-250 Rc 1 / 4 G 1 / 4 50-50-160 Rc 1 / 4 G 1 / 4 50-50-250 Rc 1 / 4 G 1 / 4 65-65-160 Rc 1 / 4 G 1 / 4 65-65-250 Rc 1 / 4 G 1 / 4 80-80-160 Rc 3 / 8 G 1 / 4 80-80-250 Rc 3 / 8 G 1 / 4 100-100-200 Rc 3 / 8 G 1 / 4 100-100-250 Rc 3 / 8 G 1 / 4 125-125-200 Rc 1 / 2 G 1 / 4 125-125-250 Rc 1 / 2 G 1 / 4 150-150-250 Rc 1 / 2 G 1 / 4 200-200-250 Rc 1 / 2 G 1 / 4 200-200-315 Rc 1 / 2 G 1 / 4 21) Rc = ISO 7/1 18 Etaline Z PumpDrive 2 /

n = 1450 rpm, sizes 032-032-160 to 080-080-250 (a) (b) (a) Foundation fastening elements Ø 11.5 1M.1./2 Pressure gauge connection (b) Pump fastening elements M10 6B.1/.2 Drain connection 6D.1/.2 Vent/drain connection 5B Vent connection for the mechanical seal chamber Dimensions Size Motor DN 22) a b c d 23) d 1 e f 23) g 23) h h 1 k k 1 L 23) L 1 23) p 23) s 23) t x z [kw] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 32-32-160 0,55 32 75 140 70 162 M10 235 236 236 170 150 235 117,5 498 255 120 294 13 100 190 32-32-160 0,75 32 75 140 70 162 M10 235 236 236 170 150 235 117,5 498 255 120 294 13 100 190 32-32-160 1,1 32 75 140 70 190 M10 235 236 236 170 150 235 117,5 525 282 128 299 13 100 190 32-32-160 1,5 32 75 140 70 190 M10 235 236 236 170 150 235 117,5 551 308 128 299 13 100 190 32-32-200 0,55 32 105 180 70 162 M10 285 287 287 190 190 285 142,5 516 255 120 294 13 100 190 32-32-200 0,75 32 105 180 70 162 M10 285 287 287 190 190 285 142,5 516 255 120 294 13 100 190 32-32-200 1,1 32 105 180 70 190 M10 285 287 287 190 190 285 142,5 543 282 128 299 13 100 190 32-32-200 1,5 32 105 180 70 190 M10 285 287 287 190 190 285 142,5 569 308 128 299 13 100 190 32-32-200 2,2 32 105 180 70 213 M10 285 287 287 190 190 285 142,5 622 347 135 338 13 100 211 32-32-200 3,0 32 105 180 70 213 M10 285 287 287 190 190 285 142,5 657 382 135 338 13 100 211 32-32-200 4,0 32 105 180 70 234 M10 285 287 287 190 190 285 142,5 646 371 148 353 13 100 211 40-40-160 0,55 40 99 140 70 162 M10 250 243 243 170 150 250 125 510 255 120 294 13 100 190 40-40-160 0,75 40 99 140 70 162 M10 250 243 243 170 150 250 125 510 255 120 294 13 100 190 40-40-160 1,1 40 99 140 70 190 M10 250 243 243 170 150 250 125 537 282 128 299 13 100 190 40-40-160 1,5 40 99 140 70 190 M10 250 243 243 170 150 250 125 563 308 128 299 13 100 190 40-40-250 0,75 40 101 224 70 162 M10 330 310 360 220 220 330 190 521 255 120 294 13 100 190 40-40-250 1,1 40 101 224 70 190 M10 330 310 360 220 220 330 190 548 282 128 299 13 100 190 40-40-250 1,5 40 101 224 70 190 M10 330 310 360 220 220 330 190 574 308 128 299 13 100 190 40-40-250 2,2 40 101 224 70 213 M10 330 310 360 220 220 330 190 627 347 135 338 13 100 211 40-40-250 3,0 40 101 224 70 213 M10 330 310 360 220 220 330 190 662 382 135 338 13 100 211 40-40-250 4,0 40 101 224 70 234 M10 330 310 360 220 220 330 190 651 371 148 353 13 100 211 40-40-250 5,5 40 101 224 70 266 M10 330 310 360 220 220 330 190 716 413 167 374 13 100 255 40-40-250 7,5 40 101 224 70 298 M10 330 310 360 220 220 330 190 744 441 167 374 13 100 255 50-50-160 0,55 50 110 160 70 162 M10 270 254 253 180 160 270 135 522 255 120 294 13 100 190 50-50-160 0,75 50 110 160 70 162 M10 270 254 253 180 160 270 135 522 255 120 294 13 100 190 50-50-160 1,1 50 110 160 70 190 M10 270 254 253 180 160 270 135 549 282 128 299 13 100 190 50-50-160 1,5 50 110 160 70 190 M10 270 254 253 180 160 270 135 575 308 128 299 13 100 190 50-50-160 2,2 50 110 160 70 213 M10 270 254 253 180 160 270 135 628 347 135 338 13 100 211 50-50-160 3,0 50 110 160 70 213 M10 270 254 253 180 160 270 135 663 382 135 338 13 100 211 50-50-160 4,0 50 110 160 70 234 M10 270 254 253 180 160 270 135 652 371 148 353 13 100 211 50-50-250 1,1 50 110 220 70 190 M10 380 361 360 220 220 380 190 548 282 128 299 13 100 190 50-50-250 1,5 50 110 220 70 190 M10 380 361 360 220 220 380 190 574 308 128 299 13 100 190 50-50-250 2,2 50 110 220 70 213 M10 380 361 360 220 220 380 190 627 347 135 338 13 100 211 22) DN = EN 1092-2, PN 16 23) For the exact motor-related dimensions refer to the general arrangement drawing in KSB EasySelect. Etaline Z PumpDrive 2 / 19

Size Motor DN 22) a b c d 23) d 1 e f 23) g 23) h h 1 k k 1 L 23) L 1 23) p 23) s 23) t x z [kw] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 50-50-250 3,0 50 110 220 70 213 M10 380 361 360 220 220 380 190 662 382 135 338 13 100 211 50-50-250 4,0 50 110 220 70 234 M10 380 361 360 220 220 380 190 651 371 148 353 13 100 211 50-50-250 5,5 50 110 220 70 266 M10 380 361 360 220 220 380 190 716 413 167 374 13 100 255 50-50-250 7,5 50 110 220 70 298 M10 380 361 360 220 220 380 190 744 441 167 374 13 100 255 50-50-250 11,0 50 110 220 70 325 M10 380 361 360 220 220 380 190 882 546 197 405 13 100 255 65-65-160 0,55 65 133 170 70 162 M10 285 263 260 180 160 285 142,5 544 255 120 294 13 100 190 65-65-160 0,75 65 133 170 70 162 M10 285 263 260 180 160 285 142,5 544 255 120 294 13 100 190 65-65-160 1,1 65 133 170 70 190 M10 285 263 260 180 160 285 142,5 571 282 128 299 13 100 190 65-65-160 1,5 65 133 170 70 190 M10 285 263 260 180 160 285 142,5 597 308 128 299 13 100 190 65-65-160 2,2 65 133 170 70 213 M10 285 263 260 180 160 285 142,5 650 347 135 338 13 100 211 65-65-160 3,0 65 133 170 70 213 M10 285 263 260 180 160 285 142,5 685 382 135 338 13 100 211 65-65-160 4,0 65 133 170 70 234 M10 285 263 260 180 160 285 142,5 674 371 148 353 13 100 211 65-65-250 1,5 65 110 220 70 190 M10 350 339 366 265 210 330 165 599 308 128 299 13 100 190 65-65-250 2,2 65 110 220 70 213 M10 350 339 366 265 210 330 165 652 347 135 338 13 100 211 65-65-250 3,0 65 110 220 70 213 M10 350 339 366 265 210 330 165 687 382 135 338 13 100 211 65-65-250 4,0 65 110 220 70 234 M10 350 339 366 265 210 330 165 676 371 148 353 13 100 211 65-65-250 5,5 65 110 220 70 266 M10 350 339 366 265 210 330 165 741 413 167 374 13 100 255 65-65-250 7,5 65 110 220 70 298 M10 350 339 366 265 210 330 165 769 441 167 374 13 100 255 80-80-160 0,75 80 120 175 70 162 M10 324 290 280 195 165 324 162 546 255 120 294 13 100 190 80-80-160 1,1 80 120 175 70 190 M10 324 290 280 195 165 324 162 573 282 128 299 13 100 190 80-80-160 1,5 80 120 175 70 190 M10 324 290 280 195 165 324 162 599 308 128 299 13 100 190 80-80-160 2,2 80 120 175 70 213 M10 324 290 280 195 165 324 162 652 347 135 338 13 100 211 80-80-160 3,0 80 120 175 70 213 M10 324 290 280 195 165 324 162 687 382 135 338 13 100 211 80-80-160 4,0 80 120 175 70 234 M10 324 290 280 195 165 324 162 676 371 148 353 13 100 211 80-80-160 5,5 80 120 175 70 266 M10 324 290 280 195 165 324 162 741 413 167 374 13 100 255 80-80-250 2,2 80 109 224 70 213 M10 345 333 364 290 210 345 172,5 667 347 135 338 13 140 211 80-80-250 3,0 80 109 224 70 213 M10 345 333 364 290 210 345 172,5 702 382 135 338 13 140 211 80-80-250 4,0 80 109 224 70 234 M10 345 333 364 290 210 345 172,5 691 371 148 353 13 140 211 80-80-250 5,5 80 109 224 70 266 M10 345 333 364 290 210 345 172,5 756 413 167 374 13 140 255 80-80-250 7,5 80 109 224 70 298 M10 345 333 364 290 210 345 172,5 784 441 167 374 13 140 255 22) DN = EN 1092-2, PN 16 23) For the exact motor-related dimensions refer to the general arrangement drawing in KSB EasySelect. 20 Etaline Z PumpDrive 2 /

n = 1450 rpm, sizes 100-100-200 to 200-200-315 (a) (b) (a) Foundation fastening elements Ø 18 1M.1./2 Pressure gauge connection (b) Pump fastening elements M16 6B.1/.2 Drain connection 6D.1/.2 Vent/drain connection 5B Vent connection for the mechanical seal chamber Dimensions Size Motor DN 24) a b c d 25) d 1 e f 25) g 25) h h 1 k k 1 L 25) L 1 25) p 25) s 25) t x z [kw] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 100-100-200 2,2 100 196 280 98 213 M16 410 394 376 280 270 410 205 733 347 135 338 20 150 211 100-100-200 3,0 100 196 280 98 213 M16 410 394 376 280 270 410 205 768 382 135 338 20 150 211 100-100-200 4,0 100 196 280 98 234 M16 410 394 376 280 270 410 205 757 371 148 353 20 150 211 100-100-200 5,5 100 196 280 98 266 M16 410 394 376 280 270 410 205 822 413 167 374 20 150 255 100-100-200 7,5 100 196 280 98 298 M16 410 394 376 280 270 410 205 850 441 167 374 20 150 255 100-100-200 11,0 100 196 280 98 325 M16 410 394 376 280 270 410 205 988 546 197 405 20 150 255 100-100-200 15,0 100 196 280 98 325 M16 410 394 376 280 270 410 205 994 552 197 457 20 150 325 100-100-200 18,5 100 196 280 98 370 M16 410 394 376 280 270 410 205 1052 610 262 509 20 150 325 100-100-250 4,0 100 175 270 105 234 M16 480 453 439 295 255 480 240 760 371 148 353 20 140 211 100-100-250 5,5 100 175 270 105 266 M16 480 453 439 295 255 480 240 825 413 167 374 20 140 255 100-100-250 7,5 100 175 270 105 298 M16 480 453 439 295 255 480 240 853 441 167 374 20 140 255 100-100-250 11,0 100 175 270 105 325 M16 480 453 439 295 255 480 240 991 546 197 405 20 140 255 100-100-250 15,0 100 175 270 105 325 M16 480 453 439 295 255 480 240 997 552 197 457 20 140 325 100-100-250 18,5 100 175 270 105 370 M16 480 453 439 295 255 480 240 1055 610 262 509 20 140 325 100-100-250 22,0 100 175 270 105 370 M16 480 453 439 295 255 480 240 1055 610 262 509 20 140 325 100-100-250 30,0 100 175 270 105 422 M16 480 453 439 295 255 480 240 1114 669 305 558 20 140 325 125-125-200 2,2 125 221 265 95 213 M16 380 394 366 345 275 550 275 758 347 135 338 20 155 211 125-125-200 3,0 125 221 265 95 213 M16 380 394 366 345 275 550 275 793 382 135 338 20 155 211 125-125-200 4,0 125 221 265 95 234 M16 380 394 366 345 275 550 275 782 371 148 353 20 155 211 125-125-200 5,5 125 221 265 95 266 M16 380 394 366 345 275 550 275 847 413 167 374 20 155 255 125-125-200 7,5 125 221 265 95 298 M16 380 394 366 345 275 550 275 875 441 167 374 20 155 255 125-125-200 11,0 125 221 265 95 325 M16 380 394 366 345 275 550 275 1013 546 197 405 20 155 255 125-125-200 15,0 125 221 265 95 325 M16 380 394 366 345 275 550 275 1019 552 197 457 20 155 255 125-125-200 18,5 125 221 265 95 370 M16 380 394 366 345 275 550 275 1077 610 262 509 20 155 325 125-125-200 22,0 125 221 265 95 370 M16 380 394 366 345 275 550 275 1077 610 262 509 20 155 325 125-125-250 4,0 125 226 300 85 234 M16 400 409 389 360 260 400 200 787 371 148 353 20 145 211 125-125-250 5,5 125 226 300 85 266 M16 400 409 389 360 260 400 200 852 413 167 374 20 145 255 125-125-250 7,5 125 226 300 85 298 M16 400 409 389 360 260 400 200 880 441 167 374 20 145 255 125-125-250 11,0 125 226 300 85 325 M16 400 409 389 360 260 400 200 1018 546 197 405 20 145 255 125-125-250 15,0 125 226 300 85 325 M16 400 409 389 360 260 400 200 1024 552 197 457 20 145 325 125-125-250 18,5 125 226 300 85 370 M16 400 409 389 360 260 400 200 1082 610 262 509 20 145 325 125-125-250 22,0 125 226 300 85 370 M16 400 409 389 360 260 400 200 1082 610 262 509 20 145 325 150-150-250 7,5 150 256 320 120 298 M16 600 560 534 400 300 600 300 910 441 167 374 20 155 255 24) DN = EN 1092-2, PN 16 25) For the exact motor-related dimensions refer to the general arrangement drawing in KSB EasySelect. Etaline Z PumpDrive 2 / 21

Motor DN 24) a b c d 25) d 1 e f 25) g 25) h h 1 k k 1 L 25) L 1 25) p 25) s 25) t x z Size [kw] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 150-150-250 11,0 150 256 320 120 325 M16 600 560 534 400 300 600 300 1048 546 197 405 20 155 255 150-150-250 15,0 150 256 320 120 325 M16 600 560 534 400 300 600 300 1054 552 197 457 20 155 325 150-150-250 18,5 150 256 320 120 370 M16 600 560 534 400 300 600 300 1112 610 262 509 20 155 325 150-150-250 22,0 150 256 320 120 370 M16 600 560 534 400 300 600 300 1112 610 262 509 20 155 325 150-150-250 30,0 150 256 320 120 422 M16 600 560 534 400 300 600 300 1171 669 305 558 20 155 325 150-150-250 37,0 150 256 320 120 460 M16 600 560 534 400 300 600 300 1228 695 325 597 20 155 425 150-150-250 45,0 150 256 320 120 468 M16 600 560 534 400 300 600 300 1258 725 325 597 20 155 425 200-200-250 11,0 200 281 410 210 325 M16 600 585 537 530 470 600 300 1073 546 197 405 20 160 255 200-200-250 15,0 200 281 410 210 325 M16 600 585 537 530 470 600 300 1079 552 197 457 20 160 325 200-200-250 18,5 200 281 410 210 370 M16 600 585 537 530 470 600 300 1137 610 262 509 20 160 325 200-200-250 22,0 200 281 410 210 370 M16 600 585 537 530 470 600 300 1137 610 262 509 20 160 325 200-200-250 30,0 200 281 410 210 422 M16 600 585 537 530 470 600 300 1196 669 305 558 20 160 325 200-200-250 37,0 200 281 410 210 460 M16 600 585 537 530 470 600 300 1253 695 325 597 20 160 425 200-200-250 45,0 200 281 410 210 468 M16 600 585 537 530 470 600 300 1283 725 325 597 20 160 425 200-200-315 30,0 200 287 410 220 422 M16 580 593 554 520 480 580 290 1202 669 305 558 20 185 325 200-200-315 37,0 200 287 410 220 460 M16 580 593 554 520 480 580 290 1259 695 325 597 20 185 425 200-200-315 45,0 200 287 410 220 468 M16 580 593 554 520 480 580 290 1289 725 325 597 20 185 425 Flange design Flange design by materials Material variant Standard Nominal diameter Pressure class G, GB, GC EN 1092-2 DN 32 - DN 200 PN 16 Drilled to ASME B16.1 26) DN 32 - DN 100, DN 150 and DN 200 Class 125 Flange dimensions L UG1475402/02 DN / NPS K Flange dimensions Flange dimensions [mm] DN/NPS K Standard EN 1092-2 ASME B 16.1 G Material PN 16 Class 125 Number of holes K G Number of holes 32/NPS 1 1 / 4 100 4 19 88,9 4 15,7 40/NPS1 1 1 / 2 110 4 19 98,6 4 15,7 50/NPS 2 125 4 19 120,7 4 19,1 65/NPS 2 1 / 2 145 4 19 139,7 4 19,1 80/NPS 3 160 8 19 152,4 4 19,1 100/NPS 4 180 8 19 190,5 8 19,1 125/NPS 5 210 8 19 - - 150/NPS 6 240 8 23 241,3 8 22,4 200/NPS 8 295 12 23 298,5 8 22,4 24) DN = EN 1092-2, PN 16 25) For the exact motor-related dimensions refer to the general arrangement drawing in KSB EasySelect. 26) DN 80 machined like DN 100 22 Etaline Z PumpDrive 2 /

Typical installation positions Horizontal installation Examples Special aspects Direction of flow from bottom to top Note: Motors of size 160 (11 kw) and above on pump sets with horizontal motor axis require adequate support! The foot fastening holes on the motor housing can be used for this purpose. Direction of flow from bottom to top If the piping is laid horizontally, the upper pump must be vented through the upper screw plug 6 B.1/.2 and vent valve 5B.1/.2. This will ensure trouble-free operation. Horizontal piping If one of the pumps needs to be serviced, the pump chamber can be shut off by a blind flange so that the system remains operational. Note: Motors of size 160 (11 kw) and above on pump sets with horizontal motor axis require adequate support! The foot fastening holes on the motor housing can be used for this purpose. c = Blind flange d = To be supported Installation with blind flange Vertical installation Examples Special aspects Sizes 032-032-160 to 080-080-350 are fixed in place without feet. Vertical installation without feet Sizes 032-032-160 to 200-200-315 are fixed in place using three angle feet (St 37, accessories depend on the size). Vertical installation, pump mounted with three feet Etaline Z PumpDrive 2 / 23

Examples Special aspects Provide a vent valve to prevent dry running of the mechanical seal. For vertical installation with the motor on top, use connection 5B for venting. 5B Vertical installation Information about vent valve The mechanical seal chamber can be vented with vent valve 5B. 5B Vent, mechanical seal chamber Accessories Pump accessories Overview of pump accessories Component Connection Mat. No. [kg] Pump foot Etaline Z 32-32 160 to 080-080 250 27) 47077960 1.5 for vertical installation Etaline Z 100-100 200 to 200-200 315 27) 47089180 3 Blind flange Etaline Z 32/40/50/65/80/100-160, 100-125 01536669 6.7 comprising blind flange and gasket Etaline Z 32/80/100/125/150-200, 125-160 01536670 12.4 Etaline Z 40/50/65/80/190/125/150/200-250 01536671 14.7 Etaline Z 200-315 01536672 22.2 27) Three pump feet with bolts 24 Etaline Z PumpDrive 2 /

Detailed designation Designation example Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 E T L Z 0 3 2-0 3 2-1 6 0 - G G - A A 0 6 D 2 0 0 3 0 4 e x B S I E I E 3 P D 2 E M See name plate and data sheet See data sheet Key to the designation Position Code Description 1-4 Pump type ETLZ Etaline Z 5-16 Pump size 032 Nominal suction nozzle diameter [mm] 032 Nominal discharge nozzle diameter [mm] 160 Nominal impeller diameter [mm] 17 Pump casing material G Grey cast iron EN-GJL-250/A48CL35 18 Impeller material G Grey cast iron EN-GJL-250/A48CL35 B Bronze CC480K-GS/B30 C90700 C Stainless steel 1.4408/A743CF8M 19 Design - Standard X Special design BT3D, BT3 20 Casing cover A Conical seal chamber 21 Type of seal V Conical seal chamber with vent A Conical seal chamber 22-23 Seal code 06 Mechanical seal material U3BEGG (shaft units 25, 35) 09 Mechanical seal material U3U3VGG 10 Mechanical seal material Q1Q1X4GG 11 Mechanical seal material BQ1EGG 22 Mechanical seal material AQ1EGG (shaft unit 55) 24 Scope of supply A Pump without motor D Pump with motor 25 Shaft unit 2 Shaft unit 25 3 Shaft unit 35 5 Shaft unit 55 26-29 Motor rating 0002 0.25 kw 0003 0.37 kw 0005 0.55 kw 0007 0.75 kw 0011 1.1 kw 0015 1.5 kw 0022 2.2 kw 0030 3.0 kw 0040 4.0 kw 0055 5.5 kw 0075 7.5 kw 0110 11.0 kw 0150 15.0 kw 0185 18.5 kw 0220 22.0 kw 0300 30.0 kw 0370 37.0 kw 0450 45.0 kw 0550 55.0 kw 30 Number of poles Etaline Z PumpDrive 2 / 25

Position Code Description 4 4 poles 31-32 Explosion protection ex 33 Product generation B 34-36 Motor manufacturer KSB 37-39 Efficiency class 40-43 PumpDrive 44 PumpMeter Explosion-proof motor -- Without explosion-proof motor SIE LOH HAL IE1 IE2 IE3 IE4 PDB PDA PD2 PD2E M Product generation Etaline Z KSB Siemens Loher Halter IE1 IE2 IE3 IE4 PumpDrive 1st generation, Basic PumpDrive 1st generation, Advanced PumpDrive 2nd generation PumpDrive 2nd generation, Eco With PumpMeter 26 Etaline Z PumpDrive 2 /

Heating / Air-conditioning / Ventilation PumpMeter Technical data Technical data of the display unit Characteristic Power supply Power input Analog signal output Digital connection Value +24 V DC ±15 % 150 ma 4-20 ma, 3-wire RS485, Modbus RTU (Slave) IP6528) RS232-30 C to +80 C -10 C to +60 C Enclosure Service interface Storage temperature Operating temperature Technical data of the sensors Characteristic Signal Enclosure Fluid temperature Installation torque Ambient temperature Value 4-20 ma IP6728) -30 C to +140 C 10 Nm -10 C to +110 C Sensor pressure limits General description The PumpMeter device is an intelligent pressure transmitter for pumps, with on-site display of measured values and operating data. The device comprises two pressure sensors and a display unit. It records the load profile of the pump in order to indicate any potential for optimising energy efficiency and availability. PumpMeter is supplied completely assembled and parameterised for the pump it is used with. It is ready for operation as soon as the M12 plug connector is plugged in. Sensor measuring range [bar] min -1-1 -1-1 -1-1 -1 max 3 10 16 25 40 65 80 Overpressure range [bar] Burst pressure [bar] 40 40 40 50 80 130 160 60 60 60 75 120 195 240 Materials Main applications Overview of materials Industry: Wetted components Pressure sensor measuring unit Pressure sensor process connection Adapter for fitting a sensor29) Gasket Refrigeration/distribution Heat generation/distribution Water treatment Material 1.4542 1.4301 1.0037 or 1.4571 Centellen Cooling lubricant distribution Water extraction Service water supply Water: Water extraction/withdrawal Water treatment/conditioning Water distribution/transport Building services: Air-conditioning systems Heat generation/distribution Water supply systems 28) 29) Product benefits Transparent pump operation Local output of the relevant operating data, especially the operating point of the pump. Identifies energy saving potentials by recording and analysing the load profile and displaying the energy efficiency icon (EFF), if applicable. Saves time and money The sensors are fitted to the pump at the factory, unlike conventional instruments used in systems. Helps increase pump availability by recognising and avoiding operation outside of the intended operating range. Provided that the connectors are connected correctly Depending on the basic material variant of the pump PumpMeter 27