Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight

Similar documents
N2MV Series W Non-metallic

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Applications. Standard Materials

DMV Series W For Combustible Dusts

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Steel Outlet Boxes 4 11 /16" Welded

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Lighting: Explosionproof Area HID. Applications. Standard Materials

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

AFL FLOODLIGHT SERIES

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Applications. Standard Materials. Certifications and Compliances

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

Applications. Standard Materials. Certifications and Compliances

Champ NVMV Series Ex-Protected Luminaire for IEC and ATEX Applications

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Champ MLL LED luminaires

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Areamaster LED Flood/High Bay Luminaires

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

LED lighting for hazardous areas Champ MLL LED Luminaires. Champ MLL. LED luminaires for hazardous areas

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

ACE Series Explosionproof Variable Frequency Drives

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Applications. Illustrated Features

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations


SXPJ SERIES S X azz.com/rigalite

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

KAD250MR3TBSPD04 Wall Fixture

80 Watt Multi-Purpose LED Area Light

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Overall Dimensions. Specifications

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

PGL350P W PS Wallpack

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Standard Grade 14 Inch Reflector. Ordering Information

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

EDS / EFS Series Control Stations

VINCI-LED Wall/Area/Flood Lighting

KH Series Kemlux III Enclosed/Gasketed

GHG43 Series Control Stations

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

150W Explosion Proof Telescoping Anodized Aluminum Pole Mount LED Light Tower ' -Surface Mount

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

Overall Dimensions. Specifications

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

ORDERING INFORMATION: 120 Volts (120)

LED lighting for land-based rigs Pauluhn DLL Series LED Luminaires. Pauluhn DLL Series. LED luminaires for land-based drilling

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

Explosion Proof Quadpod Mount - Single 150 Watt Led Light foot cord

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

OP2 CosmoPolis Series

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

HOLOPHANE Outdoor Lighting

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

COMPACT FLUORESCENT EMERGENCY FIXTURES

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord

EDS / EFS Series Control Stations

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

Transcription:

Champ Fixtures Class I, Division Class I, Zone Floodlight

Champ Floodlight Fixtures Whenever Cooper Crouse-Hinds develops a new product, system, or procedure, we focus on one overriding question: Will it lower the total cost of ownership for our customers? With our new expanded line of Champ Floodlights, the answer is most definitely, Yes. Cooper Crouse-Hinds utilized more than 00 years of hazardous lighting expertise to design a global floodlight line of unmatched reliability, quality, and performance for your area lighting needs. Energy efficient with optimal light output and beam distribution The most accessible ballast assembly in the industry Restricted breathing is standard on all floodlights Offered with both North American ballast (made to ANSI standard) and European style IEC ballast gear (pending) UL Marine rated, NEMA Type 4X and IP66 CHAMP FLOODLIGHT FAMILY Champ FMV nr Series Floodlight The Champ FMV nr Series floodlight offers exceptional indoor and outdoor illumination in industrial areas. Because of its superior corrosion resistance and restricted breathing being standard, the FMV floodlight is the ideal choice for diverse industrial applications that include wet and marine environments. NEW Differentiations: Full frame trunnion mounting bracket Restricted breathing standard 55 C and 65 C ambient air suitability Standard with terminal blocks Class I, Division /Zone Removable ballast tray Champ FMV Mini-Floodlight The FMV is a compact floodlight that consists of a Corro-Free epoxy coated copper-free aluminum enclosure with stainless steel external hardware and an impact-resistant glass lens. It is suitable for marine and wet locations and is ideal where space constraints restrict the use of larger floodlights. Differentiations: Small compact size Easy mounting installation only bolts! Powerful light distribution for floodlight and task applications Rated for use in 65 C ambient air for hazardous location applications PHOTOMETRICS ARE AVAILABLE ONLINE

The Standard for Safety & Reliability Product Selector Chart Hazardous Class I, Division Class I, Zone FMV MINI FMV nr FMV000 nr VOYAGER nr Hazardous Restricted Breathing (Ex nr) Atex certification with IEC ballast and lamp socket NEC/CEC: Class I, Division Class I, Zone IEC Zone IEC Zone Ex nr II ATEX pending pending Wet Marine NEMA Type 4, 4X NEMA 7x6 Corrosion Resistant Confined Areas Wattage High Pressure Sodium Metal Halide 5050 7075 50400 75400 600, 750, 000 000, 500 50400 75400 Champ FMV000 nr High Wattage Floodlight The Champ FMV000 nr prides itself on offering restricted breathing and easy-to-wire terminal blocks as standard components. It is NEMA Type 4X and IP66 watertight and due to its heavy-duty vapor-tight, copper-free aluminum housing and stainless steel hardware, it is exclusively designed for harsh and industrial areas requiring broad area lighting. The Champ FMV000 nr provides a robust design for optimal use in the most corrosive/marine environments. Differentiations: NEW Hazardous location high wattage floodlight for Class I, Division, Zone Restricted breathing standard rating in Class I, Zone 40 C and 55 C ambient air suitability Hinged removable door Available in 600, 750, 000 and 500W systems Champ Voyager nr Stainless Steel Floodlight The Champ Voyager nr Floodlight offers the industry's coolest temperature rating and is the only mogul-base Class I, Division and Zone stainless steel floodlight with restricted breathing as standard construction. It boasts a wide, powerful beam to deliver more light to your process, and with the standard terminal block and removable ballast-component tray, the Champ Voyager is perfect for outdoor, marine, corrosive, and high temperature locations. Differentiations: Housing, door and external parts are all 36 stainless steel Restricted breathing standard with T-ratings of and T4 Pre-wired with terminal blocks for easy wiring Hinged door and removable ballast tray PHOTOMETRICS ARE AVAILABLE ONLINE 3

Champ FMV nr Floodlights NEW The Champ FMV nr Series floodlight offers exceptional illumination in industrial areas, both indoors and out. And, it comes standard as a restricted breathing luminaire. The Champ FMV nr Series Floodlight is easily adjusted to aim light where it s needed and is available in a wide variety of energy-saving mogul base HID light sources and wattages including: The FMV is made with heavy-duty, die-cast aluminum components and stainless steel hardware. It offers superior corrosion resistance to ensure longer life, which makes the FMV floodlight the ideal choice for a wide variety of industrial applications including wet and marine environments. The only full frame trunnion mount floodlight with a rating and a removable ballast tray assembly. Key Features & Benefits: AEx nr, Ex nr restricted breathing rating is standard a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability NEMA 7x6 butterfly beam floodlight pattern wide, uniform and far reaching to provide excellent efficiency and more light where you need it NEMA Type 4X and IP66 construction is designed for use indoor and outdoors in marine and wet locations with stainless steel external hardware suitable for saltwater and corrosive applications Easy wiring standard terminal block with marked terminals saves time and eliminates wiring errors Vapor tight sealing cable connector standard Will accommodate existing mounting hardware SFA6 slipfitter for pole and SWB6 wall mount Optional metric machining will accept M0 or M5 (must be specified on order) 40 C, 55 C and 65 C ambient suitability addresses high ambients common at industrial facilities Low ambient capability to -40 C perfect for colder climates Heavy-duty, die-cast copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance Hinged door frame assembly has captive cover screws for ease of relamping Yoke mount design standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor) or any angle in between 3-axis resonance withstand and UL844 vibration compliant can stand up to the tough jobs Precision formed aluminum reflector superior beam control, distribution and efficiency offering a choice of 0, 08, 40 and 77V; 0V 50Hz, 40V 50Hz, Tri-Tap (0, 77 and 347) and 480V ballasts are also available cost-effectiveness in a high-wattage floodlight Mount Bracket accessories further enhances mounting flexibility 4 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV nr Floodlights Ratings (Electrical/Size): SOURCES/WATTAGES (MOGUL BASE LAMPS) Industry Best for Ease of Installation:. Removable ballast tray. Prewired to terminal blocks 3. Substantial room for wiring Standard Materials: aluminum Standard Finishes: Certifications & Compliances: NEC/CEC (NEC ballast gear and socket) IEC (IEC ballast gear and socket) UL/cUL STANDARDS for installation on marine vessels IEC STANDARDS VOLTAGES Standard voltage ballasts Optional voltage ballasts Isolated ballasts HUB SIZE Ordering Information for Floodlight with NEC Ballast: LAMP TYPE WATTS YOKE MOUNT 3/4" NPT HUB High Pressure Sodium Metal Halide 50 50 400 75 50 400 FMVSY50 76 FMVSY50 76 FMVSY400 76 FMVMY75 76 FMVMY50 76 FMVMY400 76 VOLTAGE SUFFIXES Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 To complete Catalog Number, add Voltage and Options suffix(es). Example: FMVMY400/MT 76 M5 VPC0 Series Lamp Type Yoke Watt Voltage Beam Spread Metric Entry Options Photocell 50W HPS fixtures are furnished with ANSI spec/s55 ballasts for 55V lamps. PHOTOMETRICS ARE AVAILABLE ONLINE 5

Champ FMV nr Floodlights Options: DESCRIPTION Instant Restrike And Ballast Guard Instant Restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Factory assembled w/hid lamp installed Fused (not suitable for marine applications) 0mm metric thread for conduit opening 5mm metric thread for conduit opening Furnished with lamps (not installed) Retention chain Pulse-Start Metal Halide Enclosure machined for conduit/cable entries SUFFIX TO ADD TO CATALOG NO. TIR FA S658 M0 M5 NPT75 S74 S83 S88 S886 Options for Photocell: Accessories (Order Separately): Slipfitter Adapter To be mounted to yoke mount fixture Wall Bracket DESCRIPTION Photocell 0V, 50/60Hz installed Photocell 08-40V, 50/60Hz installed Photocell 77V, 50/60Hz installed Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability SUFFIX TO ADD TO CATALOG NO. VPC0 VPC VPC7 SFA6 SWB6 Photometric Data: 5 4 3 Lamp: 400W Clear HPS Lumen rating: 50,000 For 50W HPS, multiply footcandles by.3. 0 For 50W HPS, multiply footcandles by 0.6. Fixture located at 0, 0 aiming angle at 45 4 3 0 3 4 (Note: See Figures and on page 7.) Isofootcandle chart FMV 400W High Pressure Sodium (HPS) Catalog Number: FMVSY400-76 Effective Projected Area (EPA): AIMING ANGLE EPA 0 30.5 FT 45. FT Footcandle Table: MOUNTING HEIGHT FOOTCANDLE VALUES FOR ISOFOOTCANDLE LINES A B C D E 5 4 3 0 4 3 0 3 4 Isofootcandle chart FMV 400W Metal Halide (MH) Catalog Number: FMVMY400-76 Lamp: 400W Clear MH Lumen rating: 34,000 For 50W MH, multiply footcandles by 0.6. Fixture located a 0, 0 aiming angle 45 (Note: See Figures and on page 7.) 5' 8.00 4.00.00 0.80 0.40 0' 4.5.3. 0.50 0.3 5'.4 0.7 0.30 0.4 30'.0.0 0.5 0.0 0.0 35'.5 0.7 0.4 0.5 0.07 40'. 0.6 0.3 0. 0.06 6 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV nr Floodlights Weight and Dimensions: 6.8 [73.9] 8.0 [458.0] NET FIXTURE WEIGHTS (LBS.): FIXTURES FMVS FMVM 50W 37 37 7550W 40 4 400W 44 44 0.0 [508.0] 3.6 [600.] SFA6 (Slipfitter Adapter) Add 4 lbs., SWB6 (Wall Bracket) Add 6 lbs. 30 90 60 30 0 90 9. [485.8] Figure Figure 4.8 [0.7].6 DIA. [4.3] Temperature Performance Data: CATALOG SERIES FMVS FMVM TYPE High Pressure Sodium Metal Halide Pulse- Start Metal Halide Lamp Selection (Mogul Base): FIXTURE LAMP FMVSY50 FMVSY50 FMVSY400 WATTS 40 C AMBIENT 55 C AMBIENT 65 C AMBIENT TEMPERATURE CODE TEMPERATURE CODE TEMPERATURE CODE ZONE WATTS TYPE 50 HPS 50 HPS 400 HPS DIV. SUPPLY WIRE C ZONE BULB G.E. OSRAM PHILIPS ED3 / BT5 ED8 / OR ET8 ED37 / B7 DIV. SUPPLY WIRE C LU50/55 LU50 LU400 ZONE DIV. LU50/55 LU50 LU400 SUPPLY WIRE C FIXTURE AIMING RANGE FIGURE 50 T4 35 T4 35 35 05 T4 35 35 05 35 05 0 50 T4 35 T4 35 35 05 T4 35 35 05 35 05 0 400** 35 T 05 35 05 T 5 0 75 T4 35 T4 35 35 05 T4 35 T4 35 05 35 05 0 50* T4 35 T4 35 35 05 T4 35 T4 35 05 35 05 0 400** 35 35 05 35 05 35 5 0 75 T4 35 35 05 35 05 T4 35 35 05 35 05 0 50* T4 35 35 05 35 05 T4 35 35 05 35 05 0 400** 350 05 350 05 350 05 T 5 0 *Suitable for use in 65 C ambient without optional fuses. **Suitable for use in 55 C ambient without optional fuses. C50S55 C50S50 C400S5 FMVMY75 FMVMY50 FMVMY400 75 MH 50 MH 400 MH ED8 OR BT8 ED8 OR BT8 ED37 OR B7 MVR75/U MVR50/U MVR400/U M75/U M50/U M400/U MH75/U MH50/U MH400/U PHOTOMETRICS ARE AVAILABLE ONLINE 7

Champ FMV000 nr High Wattage Floodlights NEW The Champ FMV000 Series high wattage floodlight is the best in its class with heavy-duty vapor-tight housing designed exclusively for harsh industrial areas requiring broad area lighting. The FMV000 Series floodlight boasts restricted breathing and easy-to-wire terminal blocks as standard. It is available in the following HID lamp sources and wattages: The Champ FMV000 Series is NEMA Type 4X and IP66 watertight, and its heavy-duty aluminum housing and stainless steel hardware provide a robust design suitable for the most corrosive/marine environments. Industry Best for Ease of Installation:. Removable ballast tray. Prewired to terminal blocks 3. Substantial room for wiring Restricted breathing comes standard with this NEMA Type 4X and IP66 rated floodlight. Key Features & Benefits: standard a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability wide, uniform and far reaching to provide excellent efficiency and more light where you need it for use indoor and outdoors in marine and wet locations with stainless steel external hardware suitable for saltwater and corrosive applications standard terminal block with marked terminals saves time and eliminates wiring errors standard 3/4 inch Myers hub (Myers hub is an option). Optional metric machining will accept M0 or M5 (must be specified on order) perfect for colder climates, 50ºC workhorse in hot climates with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance superior beam control, distribution and efficiency cost-effectiveness in a high-wattage floodlight Standard Materials: Standard Finishes: Certifications & Compliances: NEC/CEC (NEC ballast gear and socket) IEC (IEC ballast gear and socket) pending 8 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV000 nr High Wattage Floodlights Ratings (Electrical/Size): SOURCES/WATTAGES (MOGUL BASE LAMPS) VOLTAGES Standard Voltage Ballasts Optional Voltage Ballasts Isolated Ballasts HUB SIZE Temperature Performance Data: 30 75 45 CATALOG SERIES TYPE LAMP WATTAGE Ordering Information for Floodlight with NEC Ballast: LAMP TYPE WATTS BASE CATALOG NUMBER* High Pressure Sodium Metal Halide 600 750 000 000 500 FMVSY600 76 FMVSY750 76 FMVSY000 76 FMVMY000 76 FMVMY500 76 VOLTAGE SUFFIXES Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 *To complete Catalog Number, add Voltage and Options suffix(es). Options 40 C AMBIENT 50 C AMBIENT TEMPERATURE CODE ZONE Example: FMVS Y000/MT 76 M5 S88 DIV. Series Lamp Type SUPPLY WIRE C Yoke Watt TEMPERATURE CODE ZONE Voltage DIV. Beam Spread Metric Entry SUPPLY WIRE C Pulse-start Metal Halide Only FIXTURE AIMING RANGE FIGURE Figure FMVS High Pressure Sodium 600 750 000 T T T TS T T T 05 05 05 30 90 60 Metal Halide 000 T T 05 Figure FMVM Pulse-Start Metal Halide 750 750 000 000 T T T T T T 05 05 75 75 Accessories (Order Separately): Slipfitter Adapter: SFA6 Wall Bracket: Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability SWB6 Photocell in DS cover for use with FS/FD box: 0V, 50/60Hz DS0 08-40V, 50/60Hz DS 77V, 50/60Hz DS7 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV 000 High Wattage Floodlights Options: DESCRIPTION 0mm metric thread for conduit opening 5mm metric thread for conduit opening SUFFIX TO ADD TO CATALOG NO. M0 M5 NPT75 Effective Projected Area (EPA): AIMING ANGLE EPA 0 3.5 FT 30 3.6 FT 60 Pulse-start metal halide only Retention chain S88 S83 540.3 79..0 Enclosure machined for conduit/cable entries S886 Factory assembled, lamp installed in lampholder FA 557.5.9 30. Weight and Dimensions: NET FIXTURE WEIGHTS (LBS.): FIXTURE SERIES FMVSY600 78 FMVSY750 76 FMVSY000 83 FMVMY000 76 FMVMY500 84 Photometric Data: 3.5 Ø.5 MTG HOLES 0.7 4.8 5 4 3 0 4 3 0 3 4 Isofootcandle chart FMV 000W High Pressure Sodium (HPS) Catalog Number: FMVSY000-76 Lamp: 000W Clear HPS Lumen rating: 40,000 Fixture located at 0, 0 aiming angle at 45 5 4 3 0 4 3 0 3 4 Isofootcandle chart FMV 000W Metal Halide (MH) Catalog Number: FMVMY000-76 Lamp: 000W Clear MH Lumen rating: 0,000 For 500W MH, multiply footcandles by.4 Fixture located a 0, 0 aiming angle at 45 Lamp Selection (Mogul Base): FIXTURE WATTS TYPE BULB G.E. OSRAM PHILIPS FMVSY600 600 HPS T5 LU600/T C600S06 FMVSY750 750 HPS ED37 LU750 FMVSY000 000 HPS E5 LU000 C000S5/ED37 FMVMY000 000 MH BT56 MVR000/U MH000/U FMVSY500 500 MH BT56 MVR500/U/SPORTS MH500/BD 0 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ Voyager nr Stainless Steel Floodlight At last, a hazardous-area luminaire with complete stainless steel exterior, low temperature ratings and standard with the restricted breathing rating (vapor-tight design). Cooper Crouse-Hinds Champ Voyager nr Stainless Steel Floodlight offers the industry s coolest temperature ratings so it can operate below the ignition temperature of vapors and gases in your classified area. The Champ Voyager nr floodlight boasts a wide, powerful beam to deliver more light to your process or pathway. Standard terminal blocks and a removable ballast-component tray bring you the best combination of easy wiring and simple maintenance in one rugged package. This unique combination of features makes the Champ Voyager nr Floodlight ideal for outdoor, marine, corrosive, and high temperature locations. And because the Champ Voyager nr Floodlight meets international standards, you can install it anywhere in the world. Key Features & Benefits: AEx nr, Ex nr restricted breathing rating is standard a hazardous location luminaire with excellent and T4 ratings without additional accessories or options NEMA 7x6 butterfly beam floodlight pattern wide, uniform and far reaching to reduce the number of luminaires you need providing excellent luminaire efficiency more light where you need it Easy wiring standard terminal block with marked terminals saves time and eliminates wiring errors Removable ballast-component tray for capacitor, igniter and terminal block to simplify maintenance and save money Housing, hinges, door frame and mounting yoke are all 36 stainless steel for marine and wet locations robust construction suitable for saltwater and corrosive applications Now available with IEC Gear and certified to the IEC Ex ATEX Directive. The only mogul-base Class I, Division and Zone stainless steel floodlight with restricted breathing (vapor-tight design) as standard construction. Industry Best for Ease of Installation:. Removable ballast tray. Prewired to terminal blocks 3. Substantial room for wiring PHOTOMETRICS ARE AVAILABLE ONLINE

Champ Voyager nr Stainless Steel Floodlight Standard Materials: (dimpled glossy surface) aluminum polyamide 6, neoprene bushing Standard Finishes: Certifications & Compliances: NEC/CEC (NEC ballast gear and socket) IEC (IEC ballast gear and socket) UL/cUL STANDARDS for installation on marine vessels. Ratings (Electrical/Size): SOURCES/WATTAGES (MOGUL BASE LAMPS) VOLTAGES Standard Voltage Ballasts Optional Voltage Ballasts: (for export) Isolated Ballasts HUB SIZE Ordering Information for Floodlight with NEC Ballast: LAMP TYPE High Pressure Sodium WATTS 50 50 400 CATALOG NUMBER* SSFMVSY50 76 SSFMVSY50 76 SSFMVSY400 76 Ordering Information for Floodlight with IEC Ballast: LAMP TYPE IEC REF. WATTS CATALOG NUMBER* Metal Halide VOLTAGE SUFFIXES 75 50 400 SSFMVMY75 76 SSFMVMY50 76 SSFMVMY400 76 HPS MH HST HIE *Uses IEC lamp socket E40 50 50 400 50 50 400 NSSFMVSY50/0 NSSFMVSY50/0 NSSFMVSY400/0 NSSFMVMY50/0 NSSFMVMY50/0 NSSFMVMY400/0 Voltage Suffix Voltage Suffix Tri-Tap (0, 77, /TT 0 50Hz /0 50 347V, 60Hz) Multi-Tap (0, 08, 40, /MT 0 60Hz /0 77V, 60Hz) 480V, 60Hz /480 40 50Hz /40 50 NSSFMV Floodlights are designed with IEC ballast gear and lamp socket, providing certification to the IEC Ex ATEX Directive. 40V, 60Hz /MV 40 60Hz /40 60 * To complete catalog number, add voltage and options suffix(es) Example: SSFMVSY50/MT 76. PHOTOMETRICS ARE AVAILABLE ONLINE

Champ Voyager nr Stainless Steel Floodlight 30 90 60 Temperature Performance Data: 40 C AMBIENT 55 C AMBIENT Figure 30 Figure 90 CATALOG SERIES SSFMVS SSFMVM TYPE High Pressure Sodium LAMP Metal Halide WATTS TEMPERATURE CODE ZONE **Suitable for use in 55 C ambient without optional fuses. DIV. SUPPLY WIRE C TEMPERATURE CODE ZONE DIV. SUPPLY WIRE C FIXTURE AIMING RANGE FIGURE 50** T4 TB T4 TB 05 0 50** T4 350 350 05 400 T 75** T T 05 0 50** 35 35 05 400 35 05 Accessories (Order Separately): Stainless Steel Slipfitter Adapter Stainless Steel Wall Mount Bracket Standard Slipfitter Adapter (cast aluminum) Standard Wall Mount Bracket (cast aluminum) Photocell in DS cover for use with FS/FD box: 0V, 50/60Hz 08-40V, 50/60Hz 77V, 50/60Hz SFA6 SS SWB6 SS SFA6 SWB6 DS0 DS DS7 Effective Projected Area (EPA): AIMING ANGLE EPA 0.5 FT 30.86 FT 60.07 FT Weight and Dimensions: NET FIXTURE WEIGHTS (LBS.): LUMINAIRE HPS MH 50W 75W 50W 43 4 400W 45 43 Holes PHOTOMETRICS ARE AVAILABLE ONLINE 3

Champ Voyager nr Stainless Steel Floodlight Options: Options: DESCRIPTION SUFFIX TO ADD TO CATALOG NO. DESCRIPTION SUFFIX TO ADD TO CATALOG NO. INSTANT RESTRIKE AND BALLAST GUARD Instant Restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Factory assembled w/hid lamp installed Fused (not suitable for marine applications) TIR FA S658 0mm metric thread for conduit opening 5mm metric thread for conduit opening Furnished with lamps (not installed) Pulse-start metal halide only Enclosure machined for conduit/cable entries Yoke mount and slip fitter M0 M5 NPT75 S74 S88 S886 SFA6 Photometric Data: MH WIDE BEAM REFLECTOR HPS WIDE BEAM REFLECTOR ISO FOOTCANDLE CHART 400W Metal Halide (MH) Catalog Number: SSFMVMY400/MT Lamp: 400W Clear MH Lumen Rating: 34,000 Luminaire located at 0,0 aiming angle at 45 down from horizontal For 75W MH, multiply footcandles by 0.4. For 50W HPS, multiply footcandles by 0.65. ISO FOOTCANDLE CHART 400W High Pressure Sodium (HPS) Catalog Number: SSMVSY400/MT Lamp: 400W Clear HPS Lumen Rating: 50,000 Luminaire located at 0,0 aiming angle at 45 down from horizontal For 50W HPS, multiply footcandles by 0.3. For 50W HPS, multiply footcandles by 0.57. MOUNTING HEIGHT FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES MOUNTING HEIGHT FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES A B C D E F 0' 0 4.8.4 5' 3.555.778.356.78 0' 5.5.. 5' 3..8.64.3.8.064 30'..444..044 35'.633.653.37.63.065.033 40'.50.5.5.5.05.05 A B C D E F 0' 40 0 8 4.8 5' 7.778 3.555.778.356 0' 0 5.5. 5' 6.4 3..8.64.3.8 30' 4.444..444. 35' 3.65.633.653.37.63.065 40'.5.5.5.50.5.05 4 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV Mini-Floodlights FMV is a compact floodlight consisting of a Corro-Free epoxy coated copper-free aluminum enclosure, with stainless steel external hardware and impact-resistant glass. It is available for use with the following energy-saving mogul base HID lamp types and wattages: Available in a variety of voltage ratings, this compact floodlight is suitable for marine and wet locations. The FMV floodlight is: This floodlight adds to the ever growing line of Cooper Crouse-Hinds products that are truly North American with the ability to address overseas applications as well. The result: the FMV a world-class product with global acceptance. Key Features & Benefits: Small compact size easy to install and maintain 40 C, 55 C and 65 C ambient suitability addresses high ambients common at industrial facilities Low ambient capability to 40 C perfect for colder climates Heavy-duty, copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance Continuous silicone gasketing ensure wet and marine locations integrity Stainless steel tether chain and captive cover screws secure cover to housing ensures ease of maintenance Trunnion (yoke) mount design standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor) or any angle in between Requires only two bolts to mount simplifies installation Heat- and impact-resistant tempered glass lens provides exceptional stability Shock-absorbing mogul base lamp socket cushions lamp, improves lamp life in harsh environments 3-axis resonance withstand and UL844 vibration compliant stands up to the tough jobs Precision formed aluminum reflector superior beam control, distribution and efficiency NEMA 7x6 floodlight pattern with lamp orientation base down the ideal light distribution for industrial applications Multi-tap ballasts offering a choice of 0, 08, 40 and 77V; 0V, 50Hz, 40V 50Hz, Tri-Tap (0, 77 and 347) and 480V ballasts are also available High light output with a low cost of operation a costeffective, high-wattage floodlight For use with SFA6 Slipfitter Adapter and SWB6 Wall Mount Bracket accessories further enhances mounting flexibility Restricted breathing compliance cooler T-numbers for increased hazardous locations suitability PHOTOMETRICS ARE AVAILABLE ONLINE 5

Champ FMV Mini-Floodlights Standard Materials: aluminum Standard Finishes: Certifications & Compliances: NEC/CEC IEC/NEC/CEC (Ex nr) Option UL STANDARDS CSA STANDARDS IEC STANDARDS Ratings (Electrical/Size): SOURCES/WATTAGES (MOGUL BASE LAMPS) VOLTAGES Standard Voltage Ballasts Optional Voltage Ballasts (Consult Cooper Crouse-Hinds) Isolated Ballasts (Consult Cooper Crouse-Hinds) HUB SIZE Ordering Information: LAMP TYPE High Pressure Sodium Metal Halide WATTS 50 70 00 50 70 00 75 VOLTAGE SUFFIXES Voltage (60Hz) Dual- Tap BASE CATALOG NUMBER* 3/4" NPT HUB 5 mm HUB FMVSY050 FMVSY070 FMVSY00 FMVSY50 FMVMY070 FMVMY00 FMVMY75 FMVS5Y050 FMVS5Y070 FMVS5Y00 FMVS5Y50 FMVM5Y070 FMVM5Y00 FMVM5Y75 Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 * To complete catalog number, add voltage and options suffix(es) Options Example:FMVSY070/MT VPC0 Series Yoke Voltage Lamp Type Watt Photocell For 0mm metric threads, change 5 to 0 in catalog number. Ex. FMVS0Y050/MT 6 PHOTOMETRICS ARE AVAILABLE ONLINE

Champ FMV Mini-Floodlights Options: Options: DESCRIPTION SUFFIX TO ADD TO CATALOG NO. DESCRIPTION SUFFIX TO ADD TO CATALOG NO. INSTANT RESTRIKE AND BALLAST GUARD Instant Restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. TIR Furnished with lamps (not installed) Pulse-start metal halide only Photocell 0V, 50/60Hz installed Photocell 08-40V, 50/60Hz installed Photocell 77V, 50/60Hz installed S74 S88 VPC0 VPC VPC7 Factory assembled w/hid lamp installed FA Fused (not suitable for marine applications) S658 RATIO OF DISTANCE TO MOUNTING HEIGHT RATIO OF DISTANCE TO MOUNTING HEIGHT RATIO OF DISTANCE TO MOUNTING HEIGHT Photometric Data: 4 3 0 A B C 4 3 0 3 4 4 3 0 C B A 4 3 0 3 4 4 3 0 4 3 0 3 4 A D E C B D E Isofootcandle chart FMV 50W High Pressure Sodium (HPS) Catalog Number: FMVSY50 Lamp: 50W Clear HPS Lumen rating: 6,000 For 00W HPS, multiply footcandles by.55. For 70W HPS, multiply footcandles by.40. For 50W HPS, multiply footcandles by.4. Isofootcandle chart FMV 75W Mercury Vapor (MV)* Catalog Number: FMVCY75 Lamp: 75W MV Lumen rating: 8,600 Fixture located a 0, 0 aiming angle 45 (Note: Fixture aiming angle limited to 30 past vertical through 60 before vertical.) Isofootcandle chart FMV 75W Metal Halide (MH) Catalog Number: FMVMY75 Lamp: 75W Clear MH Lumen rating: 4,000 For 00W MH, multiply footcandles by.58. For 70W MH, multiply footcandles by.37. *Mercury Vapor only available in the United States until December 3, 007 D Accessories (Order Separately): Slipfitter Adapter To be mounted to yoke mount fixture Wall Bracket Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability Effective Projected Area (EPA): AIMING ANGLE EPA 0.6 FT 30.6 FT 60. FT Footcandle Table: MOUNTING HEIGHT FOOTCANDLE VALUES FOR ISOFOOTCANDLE LINES SFA6 SWB6 A B C D E 0' 8.00 4.00.00 0.80 0.40 5' 3.56.78 0.36 0.8 0'.00.00 0.50 0.0 0.0 5'.8 0.64 0.3 0.3 0.06 30' 0.44 0. 0.04 PHOTOMETRICS ARE AVAILABLE ONLINE 7

Champ FMV Mini-Floodlights Weight and Dimensions: Fixture Weight: 6 LBS. 30 60 30 PAST VERTICLE 60 BEFORE VERTICLE Temperature Performance Data: CATALOG SERIES FMVS FMVM TYPE High Pressure Sodium Metal Halide LAMP WATTS 40 C AMBIENT 55 C AMBIENT 65 C AMBIENT TEMPERATURE CODE TEMPERATURE CODE TEMPERATURE CODE ZONE * DIV. SUPPLY WIRE C ZONE * DIV. SUPPLY WIRE C ZONE * DIV. SUPPLY WIRE C FIXTURE AIMING RANGE FIGURE 50 T6 C 75 T6 C 75 B T5 75 70 T6 A 60 T5 A 75 T4 85 00 T4 TD 75 T4 TC 50** T4 TA 75 T4 TA 85 TA 0 70 T6 C 75 T5 A 75 T4 A 85 00 T4 TD 75 T4 TD 75 T4 TC 85 75** TA 75 TA 85 TA 0 *Restricted breathing explosion protection, requires suffix S86 (TB) **Suitable for use in 65 C ambient without optional fuses. Lamp Selection (Mogul Base): FIXTURE WATTS TYPE BULB G.E. OSRAM PHILIPS VENTURE FMVSY050 FMVSY070 FMVSY00 FMVSY50 50 HPS 70 HPS 00 HPS 50 HPS ED3 / OR E / ED3 / OR E / ED3 / OR E / ED3 / OR E / LU50 LU70 LU00 LU50/55 LU50 LU70 LU00 LU50/55 C50S68 C70S6 C00S54 C50S55 FMVMY070 F MVMY00 FMVMY75 70 MH 00 MH 75 MH ED8 ED8 ED8 OR BT8 MVR75/C/U M75/C/U MH75/C/U MH70W/U/ED8 MH00/U/ED8 MH75/C/U 8 PHOTOMETRICS ARE AVAILABLE ONLINE

Inside Back Cover PHOTOMETRICS ARE AVAILABLE ONLINE

For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: U.S. (Global Headquarters): Cooper Crouse-Hinds Wolf & Seventh North Streets Syracuse, NY 3 (866) 764-5454 FAX: (35) 477-579 FAX Orders Only: (866) 653-0640 crouse.customerctr@cooperindustries.com Canada: Cooper Crouse-Hinds Canada Toll Free: 800-65-050 FAX: (800) 63-9504 FAX Orders Only: (866) 653-0645 Mexico: Cooper Crouse-Hinds, S.A. de C.V. 5-555-804-4000 FAX: 5-555-804-400 mxmercadotecnia@cooperindustries.com Latin America/Caribbean: Cooper Crouse-Hinds, S.A. de C.V. 5-555-804-4000 FAX: 5-555-804-400 Singapore: Cooper Crouse-Hinds Pte. Ltd. 65-697-4849 FAX: 65-697-489 sales@cchspore.com.sg Australia: Cooper Electrical Australia 6--8787-777 FAX: 6--9609-34 sales@cooperelectrical.com.au Europe (Germany): Cooper Crouse-Hinds GmbH 49 (0) 67 806-500 49 (0) 67 806-476 info-ex@ceag.de China: Cooper Crouse-Hinds Pte. Ltd. 86--899-3600 FAX: 86--899-4055 cchsales@cooperasia.com India: Cooper Crouse-Hinds India 9--6504-550 FAX: 9--404-8 Middle East (Dubai): Cooper Crouse-Hinds LLC 97-434-578 FAX: 97-434-640 Korea: Cooper Crouse-Hinds Korea 8--3484-6783 8--3484-6778 www.crouse-hinds.com Cooper Crouse-Hinds is a trademark of Cooper Industries, Inc. 007 Cooper Industries, Inc. Your Authorized Cooper Crouse-Hinds Distributor is: Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 7700-00 www.cooperindustries.com Printed in USA