09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

Similar documents
30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Installation, Start-Up and Service Instructions

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

RCD Air Cooled Condensing Unit (50/60 Hz)

DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

GSC13 Split System Air Conditioner

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

HCH6. Product Specifications

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

WCA4**4. Product Specifications

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

CSA6. Product Specifications. SoftSound SXC 2600

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h

Outreach Innovation Building Penn State Research Park State College, PA. Appendix E. Scroll Chiller Data. The Pennsylvania State University

Bosch BOVA Split System Heat Pump

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

Bosch BOVA Split System Heat Pump

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Standard features. Optional features

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

LUI / LUO. Condensing Units

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

Product Data FEATURES/BENEFITS. 575J 6 to 20 TONS HEAT PUMP OUTDOOR UNIT SPLIT SYSTEM with PURONr REFRIGERANT 60 Hz

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

PHR5. Product Specifications

CAS. Product Specifications

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Standard features. Optional features

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

TECHNICAL SPECIFICATIONS WSH2BF

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

C O I L M A S T E R CMC-110

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

N4A6. Product Specifications

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

CAC SERIES 12-1/2 Thru 20 Ton

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

REPLACEMENT PARTS MANUAL

Product Data. Features/Benefits. 30GXN,R ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz. 80 to 450 Tons (267 to 1511 kw)

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

Enhanced Air Conditioning

Product Catalog TSE Series Scroll Central Chillers

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

13 SEER Light Commercial 3 Phase

TECHNICAL SPECIFICATIONS

Transcription:

09DK-4SB 09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS PERFORMANCE DATA CERTIFIED DIMENSION PRINT 1994 Carrier Corporation Syracuse, New York 13221 Form 09DK-4SB Supersedes 09DK-3SB Printed in U.S.A. 199 2-94 Catalog No. 510-932

Date: Supersedes: 09DK054,064,074,084,094 AIR-COOLED CONDENSERS 09DK Rev.: -4SB JOB NAME: LOCATION: BUYER: BUYER P.O. # CARRIER # UNIT NUMBER: MODEL NUMBER: PERFORMANCE DATA CERTIFIED BY: DATE: DESCRIPTION These units are used as remote air-cooled condensers with vertical package units, liquid chilling packages or compressor units. The unit is constructed of pre-painted steel that meets 500 hour salt spray requirements. Condenser fan motors are 3 phase and are protected against single-phasing conditions. Condenser coils have an integral subcooling circuit. Standard one-year warranty. UL and CSA listed. Pre-painted steel cabinet meets 500 hour salt spray requirement. 3-phase condenser fan motors have internal overload protection. Hinged doors for control box access. All refrigerant connections are on one side of the unit. FEATURES Coils constructed of aluminum lanced sine-wave fins on mechanically expanded internally enhanced copper tubes. Base rail construction provides lifting holes and does not require field-installed mounting legs. Fan cycling head pressure control. Small unit footprint for minimal space requirements. Refrigerant Total Heat of Rejection Saturated Condensing Temperature (SCT) PERFORMANCE DATA Ambient Air Temperature Discharge Line Loss Minimum Ambient Air Temperature ELECTRICAL DATA Unit Power Supply Volts Ph Hz Condenser Fan Motor Input kw Minimum Circuit Amps Maximum Overcurrent Protection Amps OPTIONS (Factory Installed) Copper/Copper Condenser Coil ACCESSORIES (Field Installed) Motormaster III Low Ambient Head Pressure Controls to 20 F Ambient Fan Sound Reduction Kit Condenser Coil Coastal Filter Security Grille Packages Condenser Coil Hail Guard Package Accessory Control Transformer Accessory Fan Control Kit Motormaster III Relay/Sensor Kit 2

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CERTIFIED DIMENSION PRINT NOTES: 1. The approximate operating weight of the unit is: 09DK-054--- 1695 Lbs [769 Kg] 09DK-054--C 1983 Lbs [900 Kg] 09DK-064--- 1845 Lbs [837 Kg] 09DK-064--C 2278 Lbs [1033 Kg] 2. Unit must have clearances for airflow as follows: Top Do not restrict in any way. Ends 5ft[1524 mm] Sides 6ft[1829 mm] 3. All units are shipped with a capacity split tubing kit. This kit may be used by the field to obtain 100%, 50%/50% and 67%/33% capacity splits. To obtain a 33%/33%/33% capacity split, coils must be manifolded by the field. Coils are factory circuited for a 33%/33%/17%/17% capacity split. UNIT DIMENSION Y DIMENSION X 09DK-054--- 09DK-054--C 09DK-064--- 09DK-064--C 3-6 11 16 [1084 mm] 3-6 7 8 [1090 mm] 3-6 3 4 [1087 mm] 3-7 1 8 [1095 mm] 4-1 8 [1222 mm] 4-5 16 [1227 mm] 4-3 16 [1224 mm] 4-1 2 [1232 mm] OPERATING CORNER WEIGHTS A B C D 452 Lbs [205 Kg] 524 Lbs [238 Kg] 489 Lbs [222 Kg] 598 Lbs [271 Kg] 425 Lbs [193 Kg] 497 Lbs [225 Kg] 462 Lbs [210 Kg] 571 Lbs [259 Kg] 396 Lbs [180 Kg] 468 Lbs [212 Kg] 434 Lbs [197 Kg] 542 Lbs [246 Kg] 422 Lbs [191 Kg] 494 Lbs [224 Kg] 459 Lbs [208 Kg] 568 Lbs [258 Kg] CAPACITY SPLIT 100% 50%/50% 67%/33% 33%/33%/33% 33%/33%/17%/17% CONNECTIONS Type No. 5 Size Hot Gas 1, 3, 5, 7 1 1 Liquid 2, 4, 6, 8 7 Hot Gas 1, 3 5, 7 1 1 Liquid 2, 4 6, 8 7 Hot Gas 1, 3, 5 7 1 1 Liquid 2, 4, 6 8 7 Hot Gas 1 7 3, 5 1 1 Liquid 2 8 4, 6 7 Hot Gas 1 7 3 5 1 1 Liquid 2 8 4 6 7 3

4 CERTIFIED DIMENSION PRINT NOTES: 1. The approximate operating weight of the unit is: 09DK-074--- 2200 Lbs [998 Kg] 09DK-074--C 2617 Lbs [1187 Kg] 09DK-084--- 2421 Lbs [1098 Kg] 09DK-084--C 3099 Lbs [1406 Kg] 2. Unit must have clearances for airflow as follows: Top Do not restrict in any way. Ends 5ft[1524 mm] Sides 6ft[1829 mm] 3. All units are shipped with a capacity split tubing kit. This kit may be used by the field to obtain 100%, 50%/50% and 67%/33% capacity splits. To obtain a 33%/33%/33% capacity split, coils must be manifolded by the field. Coils are factory circuited for a 33%/33%/17%/17% capacity split. UNIT DIMENSION Y DIMENSION X 09DK-074--- 09DK-074--C 09DK-084--- 09DK-084--C 3-6 1 2 [1080 mm] 3-6 13 16 [1087 mm] 3-6 5 8 [1082 mm] 3-7 [1092 mm] 4-8 11 16 [1440 mm] 4-9 3 8 [1458 mm] 4-9 1 8 [1450 mm] 4-10 1 8 [1476 mm] OPERATING CORNER WEIGHTS A B C D 618 Lbs [280 Kg] 722 Lbs [328 Kg] 673 Lbs [305 Kg] 843 Lbs [382 Kg] 526 Lbs [239 Kg] 630 Lbs [286 Kg] 581 Lbs [264 Kg] 751 Lbs [341 Kg] 486 Lbs [220 Kg] 589 Lbs [267 Kg] 541 Lbs [245 Kg] 709 Lbs [322 Kg] 571 Lbs [259 Kg] 675 Lbs [306 Kg] 626 Lbs [284 Kg] 796 Lbs [361 Kg] CAPACITY SPLIT 100% 50%/50% 67%/33% 33%/33%/33% 33%/33%/17%/17% CONNECTIONS Type No. 5 Size Hot Gas 1, 3, 5, 7 1 3 Liquid 2, 4, 6, 8 7 Hot Gas 1, 3 5, 7 1 3 Liquid 2, 4 6, 8 7 Hot Gas 1, 3, 5 7 1 3 Liquid 2, 4, 6 8 7 Hot Gas 1 7 3, 5 1 3 Liquid 2 8 4, 6 7 Hot Gas 1 7 3 5 1 3 Liquid 2 8 4 6 7

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CERTIFIED DIMENSION PRINT NOTES: 1. The approximate operating weight of the unit is: 09DK-094--- 2850 Lbs [1294 Kg] 09DK-094--C 3560 Lbs [1615 Kg] 2. Unit must have clearances for airflow as follows: Top Do not restrict in any way. Ends 5ft[1524 mm] Sides 6ft[1829 mm] 3. Mounting holes may be used to mount unit to concrete pad. They are not recommended for mounting unit to spring isolators. If spring isolators are used, a perimeter support channel between the unit and the isolators is recommended. UNIT DIMENSION Y DIMENSION X 09DK-094--- 09DK-094--C 5-2 7 8 [1597 mm] 5-2 7 8 [1597 mm] 3-9 3 16 [1148 mm] 3-9 3 16 [1148 mm] OPERATING CORNER WEIGHTS A B C D 769 Lbs [349 Kg] 960 Lbs [436 Kg] 676 Lbs [307 Kg] 845 Lbs [383 Kg] 658 Lbs [299 Kg] 821 Lbs [372 Kg] 747 Lbs [339 Kg] 934 Lbs [424 Kg] 199 HOT GAS 5