V500 and V510 VERIS Verabar Installation and Maintenance Manual

Similar documents
V150 VERIS Verabar Installation and Maintenance Manual

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

PT-516 Pumping Trap Installation and Maintenance

CV Control Valves Installation and Operation Manual

Digital-Flo TM Boiler Water/Water Plate & Frame Heat Exchanger

Armstrong Steam Filters (ASF)

V550 Spring Lock Flanged Connection with Packing Gland

Regular Models. V150 Spring Lock Threaded Components

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

ActuLink ABS Module - ABS-MOD-400

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

HR-20P Pneumatically Controlled Pressure Regulator

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

DeZURIK 2 20" BOS BUTTERFLY VALVES

Rosemount 485 Annubar Pak-Lok Assembly

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Rosemount 285 Annubar Pak-Lok Assembly

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Harley Davidson FL Touring Current Xtreme

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

DODGE CUMMINS MK-2 Micro-Kleen System

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING

HPx-JDx3-xx HARNESS INSTALLATION

TBM Series 3-Way Ball Valve

DeZURIK KUL KNIFE GATE VALVES

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Scale Feeder Manifold Water Filtration System Instruction Manual

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

INSTALLATION INSTRUCTIONS

EWS FLUID END PARTS LIST

StormPro BA Series Sump Pump

PREMIER, MARINE, & STANDARD

SUNTURA SOLAR TRACKER

MEX (55) QRO (442) Web Controls

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

Rosemount 485 Annubar Flanged Assembly

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

APCO CSV-1600 SURGE CHECK VALVE

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Annubar Flowmeter Series

V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

Dual/Triple Manifold Water Filtration Systems Instruction Manual

INSTALLATION INSTRUCTIONS

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

INSTALLATION INSTRUCTIONS

EZ-IN Series Turbine Flowmeter

Flange Spreader Parts and Operating Manual

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

A Member of the. Integrated Metering Technologies

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Installation, Operation, and Maintenance Manual

SUNTURA HD SOLAR TRACKER

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Dual Port Manifold Water Filtration Systems Instruction Manual

INSTALLATION INSTRUCTION & OWNER S MANUAL

AGCO. Corn Header Manual d HEADSIGHT.COM

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Breeder Control Installation Manual

Fifth Wheel Power Hitch Operations Manual

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Installation / Operation Instructions Sunnex ORION Series Exam Lights

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

GDP STREET-GATE 38mm Wastegate System

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

TITAN FLOW CONTROL, INC.

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

DeZURIK KGC-MD KNIFE GATE VALVES

AutoSparge. Lauter Tun Level Control. Operation, Assembly & Maintenance Manual

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Installation Instructions

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

Installation Instructions

INTRODUCTION INSTALLATION

The Annubar Flowmeter Series

3M Housings CH Series

Reference Manual FM-200 Series

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Installation Instructions PART NUMBERS: 76192, 84192, CQT76192

Grinnell Grooved Fire Protection Products Grooved Fittings

Installation Instructions

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Transcription:

V500 and V510 VERIS Verabar Installation and Maintenance Manual 167-EN Please read and save these instructions

Contents General Safety Information...3 Product Information...3 Section 1: Scope...3 Purpose of this Manual... 3 Section 2: Receiving and Inspecting Receiving and Inspecting the Verabar... 3 Section 3: Safety Precautions...3 Safety Messages and Application Requirements... 3 Section 4: Installation Preparations... 3-5 Location... 3 Orientation... 4 Horizontal Piping... 4 Vertical Piping... 5 DP Transmitter/Local Indicator Location... 5 Installation Drawings and Bill of Materials... 5 Section 5: Installation Procedure... 5-8 Preparing the Pipe... 5 Weld Mounting Flange to Pipe... 6 Insert Sensor... 7 Insert Instrument Vales or Manifold... 7 Installed V500 & V510... 8 Section 6: Periodic Maintenance...9 Limited Warranty and Remedy... 11 2 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

General Safety Information Instructions and procedures listed in this manual may require special precautions to ensure the safety of the individuals performing the operations. Review the entire manual, taking note of safety messages prior to performing any operations listed in the manual. Product Information The VERIS Verabar averaging pitot flow sensor provides unsurpassed accuracy and reliability. With its solid, one-piece construction and bullet shape the VERIS Verabar makes flow measurement reliable and precise. The unique sensor shape reduces drag and flow induced vibration. The location of the low-pressure ports eliminates the potential for clogging and improves signal stability. The V500 model features flanged mounting components. The V510 model includes additional support on the opposite wall of the pipe. Section 1 Scope These instructions provide a description of procedures for installing the V500 and V510 Verabar model flow sensors. Procedures are given for all industrial flow measurement applications including liquid, steam and gas, for both horizontal and vertical piping configurations. Section 2 Receiving and Inspection The following tasks should be performed as part of the receiving inspection procedure: Check items received against the packing list. Check sensor nameplate for proper model number, serial number and tag number. Verify the actual pipe diameter matches the ID stated on the sensor nameplate. Check the bullet shaped sensor tube for any signs of damage. Damage to the sensor tube may result in erroneous flow readings. Section 3 Safety Precautions The following process should be conducted prior to installing the Verabar flow sensor: Check the maximum operating conditions on the flow sensor nameplate. Verify that the maximum operating conditions of the application do not exceed the parameters stated on the nameplate. If any pressure, temperature, or flow limits will be exceeded, contact the factory before proceeding. Check to ensure the pipe is depressurized and drained prior to installation. Verify all pressure containing components are properly installed and tightened prior to pressurizing the system. Section 4 Installation Preparations 4.1 Location For the most accurate flow measurement, a minimum straight run of pipe is required. Table 1 shows the minimum straight run requirements. If longer straight runs are available, position the Verabar such that the ratio of upstream straight run to downstream straight run is approximately 4 to 1. If straight run lengths are less than the values stated in Table 1, consult the factory for additional accuracy and location information. For additional piping configuration, see Table 1. Straightening vanes should be positioned such that the end closest to the Verabar is half way between the Verabar and the closest upstream configuration. For elbow installations, mount the Verabar in the same plane as the closest upstream elbow. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 3

Table 1. Straight Run Requirements 4.2 Orientation Verify the proper sensor orientation by checking for an -H (horizontal piping) or a -V (vertical piping) in the model number on the Verabar sensor nameplate. Deviation from the following mounting location instructions may cause inaccuracy in the flow measurement. 4.2.1 Horizontal Piping For air or gas installations, mount the Verabar in the upper 160 of the pipe to allow any condensate to drain into the pipe (Figure 1). For liquid or steam installations, mount the Verabar in the lower 160 of the pipe. This allows any entrained air to bleed back into the pipe for liquid applications and allows condensate to collect in the instrument piping for steam applications. 4 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

160 AIR AND GAS LIQUID AND STEAM 160 Figure 1. Verabar Orientation in Horizontal Pipe 4.2.2 Vertical Piping The Verabar may be mounted in any location around the circumference of the pipe for vertical piping applications. 4.3 DP Transmitter/Local Indicator Location When choosing a Verabar location, consider the DP transmitter/local indicator location: The transmitter must be mounted below the Verabar for liquid and steam applications. The transmitter must be mounted above the Verabar for air and gas applications. 4.4 Installation Drawings and Bill of Materials Additional information is available in the Installation Drawings and Bill of Materials VB-7061 (Contact factory for access information). It contains standard and alternate transmitter locations and a complete bill of materials based on the fluid type and sensor orientation on the pipe. Section 5 Installation Procedure 5.1 Preparing the Pipe Completely depressurize and drain pipe prior to installation of the Verabar. Mark the location of the hole through which the Verabar will be mounted. For V510, mark the location of the hole for the opposite end support 180 from the first hole. Use a center punch to mark the hole to prevent the drill bit from walking on the pipe. Drill the pipe with the proper sized hole per the following table (Important: Do not torch cut hole(s): Sensor Size Hole(s) Diameter V500-05 & V510-05 ½ (13mm) V500-10 & V510-10 1 (25mm) V500-15 & V510-15 1-1/2 (38mm) IMPORTANT: Deburr the hole(s) on the inside of the pipe. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 5

Instrument Head Cover Tube Nut Stud Sensor Flange Gasket Sensor Mounting Flange and Weld Coupling Weld Coupling Weld Cap V510 Only Figure 2. Verabar Model V500 & V510 Assembly 5.2 Weld Mounting Flange to Pipe Loosely bolt together (hand tight) the sensor, gasket and mounting flange. Insert the assembly into the pipe. Align the head of the sensor so that the arrow labeled flow on the head is in the direction of the flow to within 3 (degree symbol). The contour of the weld coupling should match the contour of the pipe. Check that the bottom of the weld coupling is in contact with the pipe wall. Using the appropriate weld gap (1/16 [1.5mm] typical), tack weld the mounting flange into position (see Figure 3). Gap (1/16 [1.55mm] Typical) Tack weld Protect threads Complete weld Figure 3. Weld Gap Note the flange orientation per Figure 4. The bolt holes on the flange should straddle the centerline of the pipe (2-holing pattern). For V510 models, slide the opposite end weld coupling over the tip of the sensor and tack weld into position. 6 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

4-Hole Bolt Pattern Pipe Wall Bolt holes on flange to straddle the centerline of the pipe (2 holing pattern) 8-Hole Bolt Pattern Pipe Wall Bolt holes on flange to straddle the centerline of the pipe (2 holing pattern) Figure 4. Flange Orientation Remove the sensor and sensor flange, and finish welding the weld coupling to the pipe per applicable piping codes. For V510 models, weld the weld coupling and weld cap into position. 5.3 Insert Sensor Install the sensor with the gasket between the flanges such that the flow arrow on the head of the sensor is in the direction of the flow (Figure 5). The nuts should be tightened until the gasket is completely crushed (the gasket thickness should be approximately 1/8 [3mm]). 5.4 Insert Instrument Vales or Manifolds 5.4.1 Valves If the Verabar does not have a valve head, install instrument valves using proper thread sealant. Be sure instrument shut-off valves are installed and shut prior to re-pressurizing the pipe. 5.4.2 Manifold If the Verabar has a direct or integral manifold, be sure the high and low pressure block valves are shut off prior to re-pressurizing the pipe. Vertical Pipe Orientations Direction of Flow Direction of Flow Direction of Flow Direction of Flow Horizontal Pipe Orientations Figure 5. Orientation of Flow Arrow Designs, materials, weights and performance ratings are approximate and subject to change without notice. 7

The Verabar is now properly installed (Figure 6). V500 V510 Figure 6. Installed V500 & V510 8 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

Section 6 Periodic Maintenance The assembly should be periodically checked. Verify that no leaks are present. Inspect sensor for wear or damage. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 9

Notes 10 Designs, materials, weights and performance ratings are approximate and subject to change without notice.

VERIS, Inc. Limited Warranty and Remedy VERIS, Inc. ( VERIS ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended shall be free from defects in material and workmanship for a period of five (5) years from the date of installation, but not longer than 63 months from the date of shipment from the VERIS factory, unless a Special Warranty Period applies, as noted below. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the VERIS factory. Except as may be expressly provided in a written agreement between VERIS and the user, which is signed by both parties, VERIS DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by VERIS, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to VERIS repair or replacement of the part or product, or, at VERIS option, to repayment of the purchase price. In addition to replacing any part of parts found to VERIS satisfaction to be defective, VERIS will pay the cost of shipment of both the defective part to the VERIS plant and the replacement part to the original user. As a condition of enforcing any rights or remedies relating to VERIS products, notice of any warranty or other claim relating to the products must be given in writing to VERIS: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL VERIS BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by VERIS. Special Warranty Periods are as follows: Electronic components, including without limitation, differential pressure transmitters, multivariable transmitters, flow computers, rate or totalizer displays: one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the VERIS factory. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 11

V500 and V510 VERIS Verabar Installation and Maintenance Manual Designs, materials, weights and performance ratings are approximate and subject to change without notice. Armstrong VERIS Flow Measurement Group 6315 Monarch Park Pl, Niwot, CO 80503 - USA Phone: 303-652-8550 Fax: 303-652-8552 armstronginternational.com 167-EN Printed in U.S.A. - 1/29/16 2016 Armstrong International, Inc.