PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Similar documents
PT9420. Heavy Industrial mA, mA ma*

SR1V. Industrial Low Cost String Pot

SG1 SG1-120 SG SG Voltage Divider Output Signal

HX-P420 SERIES 4 to 20 ma OUTPUT

LBB ULTRA-PRECISION GAGE HEADS

SP1 SP1-4 SP1-12 SP1-25 SP1-50 SP1-4-3 SP SP SP Compact String Pot Voltage Divider Output

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

SP1. Compact String Pot Voltage Divider Output SP1-25 SP1-50 SP SP1-50-3

MS4525 SPECIFICATIONS

SP1 SP1-4 SP1-12 SP1-25 SP1-50 SP1-4-3 SP SP SP Compact String Pot Voltage Divider Output

HCA & HCA-RA SERIES Hermetically Sealed AC LVDT

SUBMERSIBLE TRANSDUCER CABLE REPAIR

M150. Cable-Extension Position Transducer. World s Smallest Stringpot Range: inches High-Cycle Space-Critical Applications .

ECONOMY POWER 2.5 CONNECTORS

PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS

Termination Procedures for Triaxial Connectors D , D , and D

C Power Connection Kit

Type Type 1001 Transducers. I/P & E/P Transducers

PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS

POLAMCO HIGH POWER CONNECTORS STYLE

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

MS52XX SMD Pressure Sensor

C3000 SIGNAL TRANSMITTER. Introduction

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

CTRC Series Flexible Rogowski Current Transformer - Installation Guide

Control Valves Positioner

Control Valves Positioner

EB100 High Accuracy Miniature Pressure Transducer

MS52XX SMD Pressure Sensor

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

HTP PTP/ PTJ Power Connection Kit for Pipes

Pro-Series/ Electromechanical Linear Actuator

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

AMPLIMITE Cable Connector Accessories

Position Control Hard chrome-plated carbon steel piston rod with blackened threads and wrench flats Sintered bronze rod bushing Internally lubricated

More Precision. Draw-wire displacement sensors

19 1HU Splicing and Front Patching Shelf

Electronic Sensors Solid State, Reed and Proximity Sensors Feedback Packages

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

TABLE OF CONTENTS 6.0 WARRANTY

Catalog Issued 3-03 (PDF Rev )

WEB CONTROL PRODUCTS

OM Field-Type I/P Converter Model : KUX113 User's Manual

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Avtron Model M3. Rotary Pulse Generator. Easy to Install Cost Effective Rugged Construction High Resolution Versatile

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

KD45 ±20N. Description

CTE7000 / CTU7000 Series Miniature pressure transmitters

Kompensator External Low Voltage Heating Cable System

Splice Only Sub Assembly. Follow all local safety regulations related to optical fibre plant elements

User Guide. Model Insulation Tester / Megohmmeter. Introduction

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

U5200 Industrial Pressure Transducer

Valtek XL Series High Performance Positioner. for Control Valves

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

What is the secret to our success?

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

CAL. + 3½ DIGIT A/D CONVERTER +V V LED DISPLAY PRECISION FULL-WAVE RECTIFIER POWER CONVERTER TB1. AC or DC INPUT POWER

Unimotor fm 230 V 460 V Unimotor fm 230 V / 460 V

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor

Fisher 546 Electro Pneumatic Transducer

MS5201-XD SMD Gage Pressure Sensor

CTE8000 / CTU8000 Series

Electropneumatic Transducer

Installation Manual Model 3800/3810

SSI Technologies MediaSensor

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Fisher i2p 100 Electro Pneumatic Transducer

User s Manual. Model MDS-30. User s Manual. A Portable Actuator for Remotely Operating Cutler Hammer Magnum DS Breakers.

Linear Valve Electric Actuator

MYSTR ELEMENTS. % Eo/Ein % TRAVEL % TRAVEL. Examples of monotonic functions. Examples of non-monotonic functions TECHNICAL SPECIFICATIONS DIMENSIONS

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

CORCOM /// EMI FILTERS FOR MEDICAL APPLICATION - PRODUCT OVERVIEW. CORCOM EMI Filters for Medical Application - Product Overview

Model 3400 Intrinsically Safe Load Cell

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

VA9203-AGx / VA9203-Bxx / VA9203-GGx

ProCS and ProC Series Heat Trace Panelboards

DC-132 Non Spring Return Electronic Actuator Series

SRS SEALED ROTARY SENSORS

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

WLA General Purpose LED Light - PWM Dimmable

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Displacement Sensor. Model 8739, 8740, 8741

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

MS-13SR series Spring Return Linear Potentiometers

Extruded Positioning Stage

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Transcription:

PT8 Cable ctuated Sensor Industrial.. m..m bsolute Linear Position to 6 inches (5 mm) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification GENERL.6 [9 mm] Output Signal 5.6 [ mm] The PT8 with its - m feedback signal, is ideal for monitoring the stroke of a hydraulic cylinder and other applications requiring position data acquistion in harsh environments. s a member of our family of NEM -rated cable-extension transducers, the PT8 provides a feedback signal that is proportional to the linear movement of a traveling stainless-steel extension cable. Simply mount the body of the transducer to a fixed surface and attach the extension cable to the moving object. Full Stroke Range Options - to -6 inches Output Signal Options... m (-wire) and... m (-wire) ccuracy see ordering information Repeatability ±.5% full stroke Resolution essentially infinite Measuring Cable Options stainless steel or thermoplastic Enclosure Material powder-painted aluminum or stainless steel Sensor plastic-hybrid precision potentiometer Potentiometer Cycle Life see ordering information Max. Retraction cceleration see ordering information ELECTRICL Input Voltage see ordering information Input Current m max. Max. Loop Resistance (Load) (loop supply voltage - 8)/. Circuit Protection 8 m max. Impedance M ohms@ VDC, min. Signal djust, Zero from factory set zero to 5% of full stroke range Signal djust, Span to 5% of factory set span Thermal Effects, Zero.% f.s./ F, max. Thermal Effects, Span.% f.s./ F, max. spring loaded cable reel... m* (% fs.) (% fs.) cable extension ENVIRONMENTL Enclosure NEM /X/6, IP 67/68 Hazardous rea Certification see ordering information Operating Temperature - to F (- to 9 C) Vibration up to g s to Hz maximum Weight, luminum Enclosure lbs. max. Weight, Stainless Steel Encl. 6 lbs. max. *Optional -wire,...m output signal available. SENSOR SOLUTIONS /// PT8 PGE

PT8 Industrial m / m Output Signal Outline Drawing: see eyelet detail eyelet detail.99 [5,] Ø.9 [,9]* Ø.75 [9,5]**.8 [5,7].65 [,9]**.8 [,].5 [88,9].9 [6,].5 [7,6].6 [9,]. [,] 5.56 [,] max..6 [5,] RNGE,.6 [9,5] 5, 5, 5.66 [6,8] 5.99 [5,7],.85 [,6], 6.5 [,]. [76,] DIMENSIONS RE IN INCHES [MM] tolerances are ±. in. [±,5 mm] unless otherwise noted note: *tolerance = +.5. [+..] **tolerance = +.5.5 [+..] Ordering Information: Ø.7 [6,8] thru ( places).6 [,6] Model Number: Full Stroke Range: R order code: full stroke range, min: accuracy (% of f.s.): potentiometer cycle life*: PT8- - - order code: R B C D E F G order code: enclosure: cable tension: max. acceleration: Sample Model Number: PT8 - - - R range: inches enclosure/cable tension: aluminum/standard ( oz.) B measuring cable:. nylon-coated stainless E output signal:...m, -wire F electrical connection: 6-pin plastic connector G cable guide option: standard nylon cable guide 5 5 5 5 6 in. 5 in. in. 5 in. in. 5 in. in. in. 5 in. 6 in..%.%.8%.8%.8%.8%.8%.5%.5%.5%.5 x 6.5 x 6 5 x 5 5 x 5 5 x 5 5 x 5 5 x 5.5 x 5.5 x 5.5 x 5 * cycle is defined as the travel of the measuring cable from full retraction to full extension and back to full retraction Enclosure Material and Measuring CableTension: 5 6 8 7 9 aluminum stainless 6 stainless standard medium high standard medium high standard medium high 5 g 5 g g 6 g g 8 g 6 g g 8 g cable tension option specifications Range: in. 5 in. in. 5 in. in. 5 in. in. in. 5 in. 6 in. Standard: 9 oz. 6 oz. 9 oz. 6 oz. oz. 6 oz. oz. oz. 6 oz. oz. Medium: 65 oz. 6 oz. 65 oz. oz. oz. 6 oz. oz. oz. 6 oz. oz. High: 6 oz. 7 oz. 6 oz. 77 oz. 6 oz. 7 oz. oz. 6 oz. 7 oz. oz. tension tolerance: ± 5% SENSOR SOLUTIONS /// PT8 PGE

R PT8 Industrial m / m Output Signal Ordering Information (cont.): Measuring Cable: B order code: cable construction: available ranges: general use: Ø.-inch nylon-coated Ø.7-inch bare Ø.58-inch PVC jacketed vectra fiber rope Ø.-inch bare all ranges 5, 5,, 5, -inch only thru inches only, 5, 6-inch only indoor outdoor, debris, high temperature high voltage or magnetic field outdoor, debris, high temperature Output Signals: E order code: output signal options: 5* 6*... m... m... m... m... m... m sensitivity: 6 m/full stroke ±.5% m/full stroke ±.5% 6 m/full stroke ±.5% wiring configuration: wire wire wire input voltage: 8 vdc 9 vdc vdc hazardous area certification: not certified CS Example: { Hazardous rea Certification: ordercode = =... m CS Standard. Class = m = m Groups, B, C and D *IMPORTNT: intrinsically safe when powered from a CS certified zener barrier rated 8 VDC max, m max per installation drawing#67798 Electrical Connection: F order code: -ft. [ M] 6-pin metal connector w/mating plug 6-pin plastic connector w/mating plug 5-ft. [7.5 M] instrumentation cable IP 67, NEM X**,6 IP 67, NEM X**, 6 IP 65, NEM IP 67, NEM 6. in. [78 mm]. in. [6 mm] / - 5/6" [ - 8 mm] cable dia. 6 WG max conductor size connector: MSE-S-6P mating plug: MS6E-S-6S ft. x.-in. dia. [ M x mm dia.] -conductor, 8 WG /8-in. [9 mm] max cable dia. 6 WG max conductor size connector: MSE-S-6P mating plug: MS6E-S-6S 5 ft. x.-in. [7,5 M x 5 mm] dia. 6-conductor, WG shielded F order code: 5 6 7 -ft. [ M] -ft. [ M] pressure tested* -ft. [ M] pressure tested* IP 67, NEM X**,6 IP 68, NEM X**, 6P IP 68, NEM X**, 6P ft. x.-in. dia. [ M x mm dia.] 8 WG, ft. x.-in. dia. [ M x mm dia.] -conductor, 8 WG ft. x.-in. dia. [ M x mm dia.] -conductor, 8 WG 6-pin Mating Plug Waterproof Cable Instrumentation Cable pin -wire -wire 8... vdc***...9 vdc B... m out common C... m out D case ground B C D F E contact view color code -wire -wire WHITE 8... vdc***...9 vdc BLCK... m out common GREEN case ground... m out color code -wire -wire RED 8... vdc***...9 vdc BLCK... m out common GREEN case ground... m out Note: WHITE, BLUE, BROWN are not used. * Test pressure: feet [ meters] H O ( PSID) Test Medium: ir; Duration: hours. ** applies to stainless steel enclosure only. ***- VDC for hazardous area option. SENSOR SOLUTIONS /// PT8 PGE

PT8 Industrial m / m Output Signal Ordering Information (cont.): Cable Guide Options: G order code: * standard cable guide stainless steel cable guide polyurethane cable bellows integral cable brush.87 in..87 in..75 in..88 in. *note: all ranges up to 5 inches only Output Signal Selection: The output signal direction can be reversed at any time by simply changing the dip-switch settings found on the internal signal board. fter the settings have been changed, adjustment of the Zero and Span trimpots will be required to precisely match signal values to the beginning and end points of the stroke.... m or... m... m or... m output signal switch setting signal board dip-switch location internal dip switches & signal board To gain access to the signal board, remove four llen-head Screws and remove rear cover. SENSOR SOLUTIONS /// PT8 PGE

VLS Option - Free Release Protection The patented Celesco Velocity Limiting System (VLS) is an option for PT8 Series cable extension transducers that limits cable retraction to a safe to 55 inches per second. The VLS option prevents the measuring cable from ever reaching a damaging velocity during an accidental free release. This option is ideal for mobile applications that require frequent cable disconnection and reconnection. It prevents expensive unscheduled downtime due to accidental cable mishandling or attachment failure. VLS is NOT available for medium and high cable tension options, stainless steel enclosure, cable bellows or, 5 and 5-inch stroke ranges. How To Configure Model Number for VLS Option: VLS8 - = available options** - - 5 5 5 6 R B C D E F G 5 6 5 6 7 creating VLS model number (example):. select PT8 model. remove PT from the model number. add VLS. completed model number! PT8-6-- PT 8-6-- VLS + 8-6-- VLS8-6-- **Note: please contact factory for a solution to options not supported. te.com/sensorsolutions Measurement Specialties Inc. a TE Connectivity company Measurement Specialties, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. ll other logos, products and/ or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 6 TE Connectivity Ltd. family of companies ll Rights Reserved. SENSOR SOLUTIONS /// PT8 version:. // January, 7 PGE 5