Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Similar documents
Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

k VS DN (mm) Connections ( C) (m 3 /h)

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Pressure relief controller AVA (PN 25)

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Differential pressure relief controller AFPA / VFG 2 (VFG 21)

Pressure relief controller for oil V22D28 (PN 16, 25)

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Differential pressure controller AFP / VFG 2 (VFG 21)

Differential pressure controller AFP / VFG 2 (VFG 21)

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Pressure independent balancing and control valve

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Differential pressure controller AFP / VFG 2 (VFG 21)

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Pressure independent balancing and control valve AB-QM DN

Flow-compensated temperature controller AVTQ DN 15

Pressure independent balancing and control valve AB-QM DN

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

Automatic balancing valves ASV-PV DN (3rd gen.)

2, 3 and 4 - way valves VZL

ZONE CONTROLE / 2-WAY

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

3-port seat valves PN16 with flanged connection

Series 240 Pneumatic On-off Valve Type 3351

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

3-port seat valves PN6 with flanged connection

DA 50. Differential pressure controllers Adjustable set-point

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

Fan-coil valves Series

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Pressure relief controller V22 D28

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

ANSI version. The valve closes when the differential pressure rises

Static Balancing Valve

3-port valves vxf42..

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

Combi valves PN 16 with flanged connections

3-port seat valves PN16 with flanged connection

Butterfly valves PN6, PN10, PN16

Ball Valves JIP (PN 16, 25, 40)

Butterfly valves, PN6, PN10, PN16

ARI-STEVI 470 / 471 (DN15-150)

3-Port Seat Valves with Male Thread, PN 16

3-port seat valves, external thread, PN16

Butterfly valves PN 16

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

3-port seat valves PN10 with flanged connection

Combined Self-operated Regulators Regulators for Differential Pressure, Flow Rate and Temperature

2-Port Seat Valves with Flange, PN 25

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

3 & 4-Way Rotary Valves

Pressure independent balancing and control valve For ON/OFF control

Butterfly valves PN6, PN10, PN16

Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244

CONTROL EQUIPMENT STAZ-16, STBZ-16

2-port seat valves PN16 with flanged connection

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Valve Series V2001 Three-way Valve Type 3323

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

2-port ball valves with flanged connection, PN25

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Series 240 Type 3351 Pneumatic On/off Valve

ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn

Data Sheet T EN

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

2- and 3-port valves with flanged connections, PN 16

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

High Temperature Valve 8024

Transcription:

Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with integrated control valve primarily for use in district heating systems or in secondary district heating systems as well. The controller closes when set max. flow is exceeded. In combination with Danfoss electrical actuators AMV(E) can be controlled by ECL electronic controllers. The controllers have a control valve with adjustable flow restrictor, connection neck for electrical actuator, and an actuator with one control diaphragm. Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13 with spring return function - AMV(E) 130, AMV(E) 140 - AMV(E) 130H, AMV(E) 140H with manual operation DN 40-100 with - AMV(E) 435 - AMV(E) 438 SD spring return function (spring down) DN 125-150 with - AMV(E) 55/56 DN 200-250 with - AMV(E) 85/86 Main data: DN 15-250 k vs 1.0-400 m 3 /h Flow range 0.035-310 m 3 /h PN 16 Flow restrictor Δp b : - 0.12 bar for DN 15-20 - 0.14 bar for DN 25-32 - 0.2 bar for DN 40, 50-0.3 bar for DN 65-100 - 0.2 bar for DN 125-250 Temperature: - Circulation water / glycolic water up to 30%: 2 120 C Connections: - Ext. thread (weld-on, thread and flange tailpieces) - Flange AHQM, DN 15-32 combined with AMV(E) 13 has been approved according to DIN EN 14597. DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 1

Ordering Example AHQM controller: Flow controller with integrated control valve, DN 15, k vs 1.6, PN 16, flow restrictor Δp 0.12 bar, t max 120 C, ext. thread - 1 AHQM DN 15 controller Code No.: 003L3594 Option: - 1 Weld-on tailpieces Code No.: 003H6908 Electrical actuator AMV(E) must be ordered separately. AHQM Controller Picture DN (mm) 15 kvs (m 3 /h) 1.0 Connection Code No. 003L3592 1.25 G ¾ A 003L3593 1.6 003L3594 20 2.5 G 1 A 003L3595 Cylindr. ext. thread acc. to ISO 228/1 25 4.0 G 1¼ A 003L3596 32 6.3 G 1¾ A 003L3597 40 12.5 G 2 A 003L3601 50 20 G 21/2 A 003L3602 50 20 003L3603 65 50 003L3604 80 63 003L3605 100 90 003L3606 Flange EN 1092-2 125 160 003L3611 150 280 003L3612 200 320 003L3613 250 400 003L3614 Accessories Picture Type designation DN Connection Code No. 15 003H6908 20 003H6909 Weld-on tailpieces 25 003H6910-32 003H6911 40 003H6912 50 003H6913 15 R ½ 003H6902 20 R ¾ 003H6903 External thread tailpieces 25 Conical ext. thread acc. to R 1 003H6904 32 EN 10226-1 R 1¼ 003H6905 40 R 11/2 065F6061 50 R 2 065F6062 15 003H6915 Flange tailpieces 20 Flanges PN 25, acc. to EN 1092-2 003H6916 25 003H6917 2 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Technical data Valve (thread version) Nominal diameter DN 15 20 25 32 40 50 k VS value Flow range 1.0 1.25 1.6 2.5 4.0 6.3 12.5 20 Q m 3 min /h 0.035 0.11 0.2 0.25 0.43 0.65 1.5 2.5 Q nom 1) 0.43 0.7 1.0 1.2 2.2 3.4 7.5 12.5 Stroke mm 5.5 5 10 Control ratio > 1:30 > 1:50 > 1:100 > 1:200 Control characteristic Leakage acc. to standard IEC 534 Linear 0.05 % of k VS Nominal pressure PN 16 Min. differential pressure see remark 2) bar Max. differential pressure 4 Medium Circulation water / glycolic water up to 30% Medium ph Min. 7, max. 10 Medium temperature C 2 120 Connections Materials Valve body Valve seat DP, CV Valve cone DP Valve cone CV Sealing DP Sealing CV 1) At differential pressure across the controller Δp AHQM 0.5 bar 2 2) Q Depends on the flow rate and valve k VS ; nom pmin p k 3) vs Depends on DN Note: DP - diff. pressure controller, CV - control valve External thread DZR CW602N (CuZn36Pb2As) 3) b EPDM Grey cast iron EN-GJL-250 (GG25) St. steel, mat. No.1.4404 St. steel, mat. No.1.4404 DZR CW602N (CuZn36Pb2As) EPDM Metal Actuator For valve DN 15 20 25 32 40 50 Actuator size cm 2 8.5 13 20 32 64 Nominal pressure PN 16 Flow restrictor diff. pressure Δp b bar 0.12 0.14 0.2 Materials Housing* Diaphragm DZR CW602N (CuZn36Pb2As) Impulse tube - * Actuator housing is part of valve body. EPDM Grey cast iron EN-GJL-250 (GG25) DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 3

AHQM (flange version) Nominal diameter DN 50 65 80 100 125 150 200 250 k vs value Flow range 20 50 63 90 160 280 320 400 Q m 3 min /h 2.5 4.0 5.6 7.6 16 32 41 62 Q nom 1) 12.5 20 28 38 82 160 208 310 Stroke mm 10 15 30 27 Control ratio > 1:200 > 1:30 > 1:300 Control characteristic Leakage acc. to standard IEC 534 0.05 % of k VS 0.01 % of k VS Nominal pressure PN 16 Linear Min. differential pressure see remark 2) bar Max. differential pressure 4 Medium Circulation water / glycolic water up to 30 % Medium ph Min. 7, max. 10 Medium temperature C 2... 120 Connections Materials Valve body Valve seat DP, CV Valve cone DP Valve cone CV Sealing DP Sealing CV St. steel, mat. No.1.4404 1) At differential pressure across the controller Δp AHQM 0.5 bar 2 2) Q Depends on the flow rate and valve k VS ; nom pmin p k 3) vs Depends on DN Note: DP - diff. pressure controller, CV - control valve Actuator St. steel, mat.no.1.4305 DZR CW602N (CuZn36Pb2As) 3) b EPDM Metal Flange Grey cast iron EN-GJL-250 (GG25) St. steel, mat. No.1.4027 St. steel, mat. No.1.4404NC St. steel, mat.no.1.4021 For valve DN 50 65 80 100 125 150 200 250 Actuator size cm 2 64 143 169 227 250 Nominal pressure PN 16 Flow restrictor diff. pressure Δp b bar 0.2 0.3 0.2 Materials Housing Grey cast iron EN-GJL-250 (GG25) St. steel, mat.no.1.0335 Diaphragm Impulse tube - Stainless steel tube Ø10 0.8 mm EPDM EPDM 4 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Application principles - Return mounting Direct-connected heating system Indirectly connected heating system - Flow mounting Direct-connected heating system Indirectly connected heating system Installation positions DN 15-32 The controllers can be installed in horizontal or vertical pipes with (connection neck for) electrical actuator oriented upwards. DN 15-32 DN 40-80 The controllers can be installed with (connection neck for) electrical actuator oriented horizontal or upwards. DN 100-250 The controllers can be installed with (connection neck for) electrical actuator oriented upwards. DN 40-80 Electrical actuator Note! Installation positions for electrical actuators AMV(E) have to be observed as well. Please see relevant Data Sheet. DN 100-250 DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 5

Pressure temperature diagram PN 16 working area DN 15-32 CuZn36Pb2As (DZR) PN 16 working area DN 40-250 EN-GJL-250 (GG-25) Maximum allowed operating pressure as a function of medium temperature (according to EN 1092-2 and EN 1092-3). 6 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Flow diagram Sizing and setting diagram Relation between actual flow and number of revolutions on flow restictor. Values given are approximate. DN 32 k VS 6.3 DN 25 k VS 4.0 DN 20 k VS 2.5 DN 15 k VS 1.6 DN 15 k VS 1.25 DN 15 k VS 1.0 1 = 360º DN 100 k VS 90 DN 50 k VS 20 (flange) DN 50 k VS 20 (thread) DN 80 k VS 63 DN 65 k VS 50 DN 40 k VS 12.5 1 = 360º DN 250 k VS 400 DN 200 k VS 320 DN 150 k VS 280 DN 125 k VS 160 1 = 360º Flow can be adjusted by turning flow restrictor screw counter-clockwise as shown in this diagram Water flow shown at differential pressure across the controller from 0.5 bar (50 kpa) to 4 bar (400 kpa). DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 7

Sizing - Directly connected heating system Example 1 Motorised control valve (MCV) for mixing circuit in direct-connected heating systems requires differential pressure of 0.12 bar (12 kpa) and flow less than 600 l/h. Given data: Q max = 0.6 m 3 /h (600 l/h) p min = 0.8 bar (80 kpa) * p circuit = 0.1 bar (10 kpa) p MCV = 0.12 bar (12 kpa) selected * Remark: p circuit corresponds to the required pump pressure in the heating circuit and is not to be considered when sizing the AHQM. The total (available) pressure loss across the controller is: p AHQM,A = p min p AHQM,A = 0.8 bar (80 kpa) Possible pipe pressure losses in tubes, shut-off fittings, heatmeters, etc. are not included. Select controller from flow diagram, page 5, with the smallest possible k vs value considering available flow ranges. k vs = 1.6 m 3 /h The min. required differential pressure across the selected controller is calculated from the formula: Δp 2 2 Q max. 0.6 AHQM, MIN = + ΔpMCV = + kvs 1.6 p AHQM,MIN = 0.26 bar (26 kpa) p AHQM,A > p AHQM,MIN 0.8 bar > 0.26 bar 0.12 Solution: The example selects AHQM DN 15, k vs value 1.6, flow setting range 0.06-0.79 m 3 /h. 8 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Sizing (continuous) - Indirectly connected heating system Example 2 Motorised control valve (MCV) for indirectly connected heating system control requires differential pressure of 0.14 (14 kpa) bar and flow less than 1500 l/h. Given data: Q max = 1.5 m 3 /h (1500 l/h) p min = 0.8 bar (80 kpa) p exchanger = 0.1 bar (10 kpa) = 0.14 bar (14 kpa) selected p MCV The total (available) pressure loss across the controller is: p AHQM,A = p min - p exchanger = 0.8-0.1 p AHQM,A = 0.7 bar (70 kpa) Possible pipe pressure losses in tubes, shut-off fittings, heatmeters, etc. are not included. Select controller from flow diagram, page 5, with the smallest possible k vs value considering available flow ranges. k vs = 4.0 m 3 /h The min. required differential pressure across the selected controller is calculated from the formula: Δp 2 2 Q max. 1.5 AHQM, MIN = + ΔpMCV = + kvs 4.0 p AHQM,MIN = 0.28 bar (28 kpa) p AHQM,A > p AHQM,MIN 0.7 bar > 0.28 bar 0.14 Solution: The example selects AHQM DN 25, k vs value 4.0, flow setting range 0.13-2.13 m 3 /h. DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 9

Design 1. Valve body 2. Control valve insert 3. Adjustable flow restrictor 4. Control valve stem 5. Valve seat 6. Differential pressure actuator 7. Control diaphragm 8. Built-in spring for flow rate control 9. Pressure relieved valve cone 10. Valve stem 11. Control drain 12. Control diaphragm cover 13. Spring cover DN 15-32 DN 40, 50 DN 50-100 10 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Design (continuous) 1. Valve body 2. Control valve insert 3. Adjustable flow restrictor 4. Control valve stem 5. Valve seat 6. Differential pressure actuator 7. Control diaphragm 8. Built-in spring for flow rate control 9. Pressure relieved valve cone 10. Valve stem 13. Impulse tube 14. Bellows for pressure relief of valve cone 15. Diaphragm for pressure relief of valve cone 16. Safety valve DN 125 DN 150 DN 200, 250 16 DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 11

Function Flow controller with integrated control valve Flow volume causes the pressure drop across the adjustable flow restrictor. Resulting pressures are being transferred through external impulse tubes or control drains within valve body to the actuator chambers and act on control diaphragm. The flow restrictor diff. pressure is controlled and limited by means of built-in spring for flow rate control. Additionally the electrical actuator will operate from zero to set max. flow according to the load. Settings Flow setting Flow setting is being done by the adjustment of the flow restrictor position. The adjustment can be performed on the basis of flow adjustment diagram (see relevant instructions) and/or by the means of heat meter. Dimensions DN 15-32 DN 15 20 25 32 L 65 82 104 130 H mm 24 31 39 49 H1 57 59 72 84 D (ISO 228/1) G ¾A G 1A G 1¼A G 1¾A Valve weight kg 0.51 0.67 1.47 2.23 DN 15 20 25 32 SW 32 (G ¾A) 41 (G 1A) 50 (G 1¼A) 63 (G 1¾A) d 21 26 33 42 R 1) ½ ¾ 1 1 ¼ L1 2) 130 150 160 - L2 mm 131 144 160 177 L3 139 154 159 184 k 65 75 85 - d 2 14 14 14 - n 4 4 4-1) Conical ext. thread acc. to EN 10226-1 2) Flanges PN 25, acc. to EN 1092-2 12 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Dimensions (continuous) DN 15-32 AMV(E) 10 + AHQM AMV(E) 13 + AHQM DN 15 20 25 32 AMV(E) 10 137 137 153 172 L* AMV(E) 13 147 147 164 183 AMV(E) 10 178 186 204 224 L** AMV(E) 13 188 196 214 234 mm AMV(E) 10 195 201 223 245 H* AMV(E) 13 210 216 238 260 AMV(E) 10 174 184 202 222 H** AMV(E) 13 180 190 208 228 DN 15 20 25 32 L* 118 125 141 160 L** 148 156 174 194 mm H* 168 178 196 216 H** 152 162 180 200 AMV(E) 130(H)/140(H) + AHQM DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 13

Dimensions (continuous) DN 40, 50 L 1 H 2 b H 1 H 3 AMV(E) 435 + AHQM AMV(E) 438 SD + AHQM DN L 1 H 1 H 2 H 3 H 4 b Valve weight mm ISO 228/1 (kg) 40 110 141.5 141 247.5 272.5 G 2 5.4 50 130 141.5 141 247.5 272.5 G 2½ 6.2 DN 40 50 H 1 SW 1 H 1 SW 2 R 11/2 2 SW 1 64 80 R d SW 2 70 82 d 48.3 60.3 H 2 H 2 L 1 mm 200 244 L 2 204 234 H 1 141.5 141 DN 50-100 H 2 H 1 a H 3 L 1 L 2 H 2 141.5 141 H 4 H 4 L 1 AMV(E) 435 + AHQM AMV(E) 438 SD + AHQM L 1 H 1 H 2 H 3 H 4 a Valve weight DN mm (EN 1092-2) (kg) 50 230 141.5 141 247.5 272.5 165 12.7 65 290 187 132 293 318 185 31.0 80 310 190 139.5 296 321 200 37.5 100 350 202 152 308 333 220 51.0 14 VD.LR.J2.02 Danfoss 06/2011 DEN-SMT/SI

Dimensions (continuous) DN 125, 150 H 2 H 1 H 2 H 1 a a L 1 L 1 AHQM DN 125 AHQM DN 150 H 3 H 3 AMV(E) 55/56 + AHQM DN 125 AMV(E) 55/56 + AHQM DN 150 DN L 1 H 1 H 2 H 3 a Valve weight mm (EN 1092-2) (kg) 125 400 267 540 576 250 126 150 480 303 472 612 285 151 DEN-SMT/SI VD.LR.J2.02 Danfoss 06/2011 15

Dimensions (continuous) DN 200, 250 a H 2 H 1 H 3 L 1 AHQM DN 200, 250 AMV(E) 85/86 + AHQM DN 200, 250 DN L1 H1 H2 H3 a Valve weight mm (EN 1092-2) (kg) 200 600 344 483 656 340 219 250 730 340 533 652 405 342 16 VD.LR.J2.02 Produced by Danfoss A/S 06/2011