Portable Oil Free Silent Series Compressor Operating Instructions

Similar documents
Portable Electric/Gas Compressor Operating Instructions

Iron Horse Air Compressor part breakdown - IHD6160V1 Item Description IHD6160V1 IHD6160V1 Call for the Customer Service Department.

MODEL HP MAXIMUM RECEIVER MOTOR DIMENSIONS WEIGHT 100 PSI RATED PSI CAPACITY L-W-H (ins) (lbs) Toll Free

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

NOTICE Carefully read this instruction manual and the engine manual before attempting to operate this compressor.

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

6 Litre Oil-Less Air Compressor

DISCLAIMER: SPECIFICATIONS:

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 -

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

6L Oil-less Air Compressor 53103

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

Routine Compressor Maintenance

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

OPERATING SERVICE MAINTENANCE MANUAL

Air Compressor PP10ND PPH10ND PP15ND PPH15ND. Operating & Maintenance Instructions

AIR COMPRESSOR AC5161B AC5161BP. User Manual

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

HEAVY DUTY ONBOARD AIR SYSTEM

MEDIUM DUTY ONBOARD AIR SYSTEM

OPERATING MANUAL AND PARTS LIST

Air Compressor. Models: CFP9HND. Operating & Maintenance Instructions

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Pump Owner s Manual. PLEASE! Read All Instructions Carefully Before Installing Pump

CAUTION READ THIS MANUAL CAREFULLY

AC3020B AC3030B PORTABLE AIR

SECTION AIR INTAKE SYSTEM

AIR COMPRESSOR IDENTIFICATION

CAUTION READ THIS MANUAL CAREFULLY

RANGER 45 / 65 AIR COMPRESSOR

See Warranty on page 6 for important information about commercial use of this product.

AIR COMPRESSOR IDENTIFICATION

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

MODEL EGA200 OWNERS MANUAL

ROYCE AIR COMPRESSOR 415VOLT/3 PHASE OPERATIONS MANUAL

WS2H/ WS3 Error Codes

INSTRUCTION MANUAL. Premium Submersible. IMPORTANT: Please read this manual carefully before running this air compressor and save it for reference.

ULTRA QUIET & OIL FREE MP100LF MP120LF

CONSTANT DUTY ONBOARD AIR SYSTEM

HEAVY DUTY ONBOARD AIR SYSTEM

MODEL EGA220 OWNERS MANUAL

TURBOCHARGER Toyota Celica DESCRIPTION OPERATION TURBOCHARGING SYSTEMS All Models

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

C T h e A d va n t a g e

Trouble Shooting Guide for WS1 - WS2 Control Valves

Tools Required. Metric Wrench Set Screwdriver Set Metric Socket Set Pliers Heavy duty hydraulic Jack and Car Stands Box knife or similar Hacksaw WD40

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

1. GENERAL INFORMATION WARRANTY- PARTS - SERVICE SERIAL # ITEM # Printed in Canada Issue Date: October 2010 Revision 12

USER MANUAL BEPOWEREQUIPMENT

AIR COMPRESSOR INSTALLATION AND START-UP MANUAL. Table of Contents. Page# 1. INTRODUCTION 2. OWNER'S OBLIGATIONS 3. INSTALLATION AND START UP

1/4 ANGLE DIE GRINDER

VT Oil-Free Range Operators Handbook

MODEL EGA130 OWNERS MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Troubleshooting 3Z8 038 Rev B

PA-C1503 PORTABLE AIR. operation manual

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

Customer Support

PRODUCT NUMBERING SYSTEM SERIES PHASE. HD: Heavy Duty (15,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (2,000+ hour life)

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Installation & Operating Manual

AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

Single Stage Wheelbarrow Air Compressor

Thank you for selecting the GD submersible grinder pump.

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

PORTABLE AIR COMPRESSOR

PORTABLE AIR COMPRESSOR

INSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA

PNEUMATICS CONTENTS HST-TAMPER

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

Belt Driven Compressor Operation Manual Model No. SACBD-100

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

SAFETY AND OPERATING MANUAL

M-3025CB-AV Fuel Pump

810201,810202,810203,810204

Electric Compressors US7580V B6000 FS002 MM36H675 SV25200 PS10M FIB02DC CV22 DT023 BG31184 BA67(2) S2AK61H

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

HYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS

WELDING FUME EXHAUSTERS & ARMS

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

HYDRAULIC PALLET TRUCKS

TECH WEST INC. Manufacturers of Dental Vacuum and Air Systems N. Argyle Ave. Fresno, CA (559) (800) FAX (559)

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

ASSEMBLY and OPERATING INSTRUCTIONS Mission Oaks Blvd. / Camarillo, CA 93011

D-Series Blowers and Exhausters

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

OPERATIONS MANUAL LEVER CHAIN HOIST

GARDEN HOSE UTILITY PUMP

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Transcription:

Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL #

1-800-551-2406 www.eaglecompressor.com

TABLE OF CONTENTS Safety Precautions 4 Cautions 4 Extension Cords.. 4 Air Receiver. 4 Safety Valve.. 5 Installation and Operating Instructions 5 Installation. 5 Break-In Procedure. 5 Before Operating the Air Compressor 5 Maintenance. 6 Operating Your Air Compressor 6 Electric Drive 6 Compressor Maintenance Schedule 7 Troubleshooting 8 Warranty. 10 Carefully read this instruction manual before attempting to operate this compressor.

SAFETY PRECAUTIONS Please familiarize yourself with the following information to prevent damage to your compressor unit and injury to the operator. The air compressor motor and/or engine will get hot while in operation. Never touch the discharge tubing, motor, or compressor pump while in operation. The compressor operates automatically while the power is connected and turned on, or the motor is running. Compressed air from the unit may contain hazardous fumes. Air produced by this compressor is not suitable for breathing purposes. Always use a respirator when spraying paint or chemicals, or when sandblasting. Always wear safety glasses or goggles when using compressed air. It is not practical or possible to warn you about all of the hazards associated with operating or maintaining this equipment. You must use your own good judgement. EXTENSION CORDS The use of extension cords is not recommended. Plug directly into a dedicated circuit. If the use of an extension cord is unavoidable then make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table 1 shows the correct size to use depending on cord length and nameplate amperage rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. AIR RECEIVER Over pressurizing the air receiver could cause personal injury or material damage. To protect from over pressurizing, a factory pre-set safety valve is installed. Page 4

NEVER WELD, DRILL, OR CHANGE THE AIR RECEIVER IN ANY WAY. Any replacement parts should be purchased with the same specifications as the original equipment. Please contact the authorized dealer for replacement parts or specifications. SAFETY VALVE This valve is factory installed to prevent over pressurizing of the air receiver. It is factory set at a specific limit for your particular model, and should never be tampered with. Adjustment by user will automatically void the warranty. DO NOT REMOVER, MAKE ADJUSTMENTS TO OR SUBSTITUTE THIS VALVE! INSTALLATION 1. INSTALLATION Proper care and maintenance ensure longevity. Do not over tighten foot bolts as excessive vibration may occur. Use only in a clean, dry, and well-ventilated area. The compressor has heat dissipation fins for proper cooling. Keep the fins and other parts that collect dust clean. Do not place rags or other materials on top of the compressor, as this obstructs cooling and can be a fire hazard. 2. BREAK-IN PROCEDURE Before anything is hooked up, run the compressor 15 minutes with the drain valve open. After the compressor has run for 15 minutes continuously, the unit is ready to use. 3. BEFORE OPERATING THE AIR COMPRESSOR, PLEASE CHECK THE FOLLOWING CAREFULLY: 1. Check to see that nuts and bolts are all snug. 2. If the intake filters are dirty, they should be replaced or cleaned. 4. COMPRESSOR LUBRICATION These units are oil free. Lubrication is not required. Page 5

INSTALLATION (cont..) 5. MAINTENANCE Before doing any maintenance or adjustments to your air compressor, the following safety precautions should be taken: * TURN OFF AND UNPLUG POWER CORD * DRAIN AIR RECEIVER AND AIR LINES OF AIR PRESSURE OPERATING YOUR AIR COMPRESSOR A) ELECTRIC DRIVE 1) Check unit for any damage. 2) Pressure switch "Off/Auto" switch should be in "Off" position. 3) Plug in power cord to proper electrical outlet. 4) Stop/Start (pressure switch) control Turn pressure switch "Off/Auto" switch to "Auto". Electric motor should now start and fill air receiver(s) with compressed air until cut-out pressure is reached. Compressor should stop and remain stopped until air receiver pressure reaches the cut-in pressure. The unit will continue to cycle in this automatic operation until the pressure switch is turned to the "Off" position. EXTRA CARE SHOULD BE TAKEN TO AVOID PERSONAL INJURIES WITH AUTOMATICALLY CONTROLLED COMPRESSORS Page 6

COMPRESSOR MAINTENANCE SCHEDULE DAILY OR BEFORE EACH USE Drain condensation from air receiver Check for any unusual noise or vibration Be sure all nuts and bolts are tight WEEKLY Turn off power. Clean dust and foreign matter from cylinder head, motor, fan blades, intercooler and air receiver. Clean air filter by opening air filter, removing filter element and cleaning it thoroughly. Worn or dirty filters should be replaced. MONTHLY Inspect unit for leaks. Tighten joints if leaks are observed. QUARTERLY OR 300 HOURS (Whichever comes first) Inspect the air receiver for corrosion or other damage Replace air filter (more often if compressor is used near paint spraying operations or in dusty environments). Page 7

TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Will not start Check power supply Make sure power is turned on Low pressure Safety valve leaks Replace safety valve Drain cock open Close drain cock Loose tubes or fittings Tighten fittings Dirty or plugged air filter Clean or replace as necessary Compressor Clogged inlet filter Clean or replace as necessary Overheats Dirty compressor, head, cylinder, Clean with compressed air intercooler Operating pressure too high Reduce operating pressure Compressor cycle too long. Allow for longer rest between Proper cycle is 50-60% on Stop/ cycles Start operation. Compressor Leaks in air system Replace worn components as Loads and necessary Unloads or Stops Pressure switch differential Make necessary adjustments and Starts adjusted too close Excessively Defective compressor valves Replace valves Compressor too small for Upgrade to larger compressor intended use Automatic Overload Reset Wait 20 minutes and the Automatic Overload will reset Insufficient Clogged inlet filter Clean or replace as necessary output, low Leaks in air lines, air valves, Replace worn components as discharge fittings, etc. necessary pressure Compressor incorrectly sized Upgrade to larger compressor Drain valve left open Close drain valve Defective pressure gauge Replace pressure gauge Leaking head gasket Replace head gasket Pressure switch adjusted too Make necessary adjustments low, or defective Worn or defective compressor Replace worn parts valves Worn piston work out ring Restrictive check valve Replace worn parts Clean check valve and replace if necessary Page 8

TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Motor stalls Faulty unloader / check valve Replace unloader check valve Valves incorrectly installed Install valves correctly Excessive Loose compressor, motor Tighten components Vibration Excessive discharge pressure Reduce operating pressure Leg bolts tightened too Loosen leg bolts tightly to floor Worn rods, wrist pin or main Check and replace worn parts bearings Compressor Compressor valves loose or Check and replace worn or Knocks broken broken valves Inspect check valve, it may Remove and clean check knock at low pressures valve Page 9

Page 10

NOTES 1-800-551-2406 www.eaglecompressor.com Page 11