Cisco Power Calculator -Power Results

Similar documents
Cisco Nexus 7700 Switches Environment

Installing and Removing Power Supplies

Switch Installation. Preparing for Installation. Warnings CHAPTER

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide

RS485 Card. User Manual

TOF Low Voltage System Review. October 6, 2006 V. Ghazikhanian 1

Installing the Air Flow Regulator

Cisco ASR 1002 Router Overview and Installation

5 5 Supervisor Engine GE (Active) VS S720 10G SAL1313MAFM

596 Rectifier Retrofit

DPoE Power System. User Manual

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

FE1-FE1*ETH Converter User Manual

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

Installing the Switch

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts V2. Overview. HP Managed and Unmanaged V2 Notebook Charging Carts

Cabinet Control Unit (CCU) User Manual

E-Series and EF-Series Systems

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Discrete Output Modules IC697MDL753

Signal White is standard finish

REMOTE POWERING Central Energy System ( HUB )

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Copyright Exertis Official Spectralink distributor for Netherlands, Belgium & Luxembourg

CHAPTER OUTLINE CHAPTER RESOURCES

POWER DISTRIBUTION UNITS (PDUs)

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

PULSE-8: MASTER PULSATION CONTROL

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

Diversion Manual (Section 6.0): 31 March 03

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Installing Power Components

TENDER DOCUMENT. TENDER No: SRO/CON/ETS/011 dated

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

3 Uninterruptible Power Systems

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

5067 Mini BDFB / BDCBB

GMT Fuse Panel Installation Guide

Installation Guide for AC-5000 V1.0 Fingerprint Identification Terminal. Apr., R&D Center Union Community Co., Ltd.

IBM CMM Quick Reference Guide

Expansion Modules for Dell PowerConnect Switches

QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS

DataCore Virtualization Appliance

HP-4 WW-R. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

SP PRO ABB Managed AC Coupling

Digital/Analog Amplifiers Installation Instructions

Power and Cooling. Chassis Power System

QuickSpecs. HP 480/277 Volt Solutions. Overview

Tip for Compute Blade 500 Power Settings. Preface. Contents

Up to 98% efficient under full load Similar runtimes to the previous 3u model

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

DP140e. Installation & Operations Manual

PV-Wind SOFTWARE for Windows User s Guide

ISA Intimidator. July 6-8, Coronado Springs Resort Walt Disney World, Florida

Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

TPM/GMT Panel Installation Guide

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Fuse / Circuit Breaker Panels

LCU DX Efficient cooling with no loss of space

MOD.15 MAE Flameproof Alternator 500W

S17-LED. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

Power Supply Specifications

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

SteelCentral Product Family Specifications

Quick Start Guide Polaris Snow Sled, and ATV

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

STEP 2 Enter Manage mode and select Discharge from the menu options.

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

UnoDrive Hardware Manual

Installing the ONS M6 Shelf

SteelCentral Product Family Specifications

20 Watt Power Supply Converts 110V AC power to 12 Volts DC for Lights

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

CHAPTER 24 - ELECTRICAL POWER TABLE OF CONTENTS

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

Smart-UPS On-Line Lithium-ion UPS 230V

AT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control

SimpliPhi Power PHI Battery

MODEL NUMBER: APS750. Highlights. Package Includes. Description

Silvertel. Ag5510. PoE Ultra Module. 1. Features. 2. Description. 60 Watt Output Power. Very small size. High efficiency DC/DC converter

Electrical Circuits W.S.

User Manual HomeGrid 5000 HD

TYPE 400, SINGLE-POSITION, GENERAL-PURPOSE O3D3-RT REVB MOUNTING

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

The concentration measurement is based on measuring the speed of sound in the liquid. The speed of sound is measured by generating an ultrasonic signa

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Waterproof DC Power Supply Converts 110V AC (wall outlet) Power to 12 Volts DC for Lights

Transcription:

Cisco Power Calculator -Power Results Disclaimer: The Cisco Power Calculator is intended to be an educational resource and a starting point in planning your power requirement; it is not a final recommendation from Cisco. This tool does not check for software compatibility. To determine the power requirements and software most appropriate for your company we suggest you work with a Cisco representative, Cisco channel partner or a solutions provider. Product Family:Catalyst 4500E Power Consumption/Heat Dissipation Summary Slot Line Card Optional Uplink Module Power Over Ethernet Capabilities 1 WS-X4748-RJ45-E -- -- 2 WS-X4748-RJ45-E -- -- 3 WS-X4748-RJ45-E -- -- 4 WS-X4748-RJ45-E -- -- 5 WS-X45-SUP7-E -- -- 6 --EMPTY-SLOT-- -- -- 7 WS-X4748-RJ45-E -- -- 8 WS-X4748-RJ45-E -- -- 9 WS-X4748-RJ45-E -- -- 10 WS-X4748-RJ45-E -- -- Minimum Power Supply Combined Catalyst 4500 1000 Watt Power Supply - Data Only Percentage Of Power Used Data:77.10% First Alternative Power Supply Combined Catalyst 4500 1300 Watt Power Supply Percentage of Power used Data:77.10%

Current Power Total Typical Output Power Total Heat Dissipation 107.11 Amps 1285.32 Watts 1028.26 Watts 5163.96 BTU/Hr

Quick Facts

Selected Supervisor Engine WS-X45-SUP7-E Selected Chassis WS-C4510R+E Selected Voltage 200-240 Volts AC Chassis Slots 10 Power Supply Options Combined 1000 Watt - Data Only Combined 1300 Watt Single/Redundant 1400 Watt - Data Only Combined 1400 Watt - Data Only Single/Redundant 2800 Watt Combined 2800 Watt 4200W with a Single 220V input 4200W with a dual 220V input Combined PWR-C45-4200W with single 220V inputs on each power supply. Combined PWR-C45-4200W with dual 220V inputs on each power supply. (Up to 5,500Watts protected. See FAQ) Combined PWR-C45-4200W with three 220 volt inputs. (Up to 5,500Watts protected, see FAQ). PWR-C45-1400DC-P 9000W with a Single 220V input 9000W with a Dual 220V input 9000W with a Triple 220V input 6000W with a Single 220V input 6000W with a Dual 220V input Combined PWR-C45-9000W with Single 220V inputs on each power supply Combined PWR-C45-9000W with Five 220V inputs

Combined PWR-C45-9000W with Dual 220V inputs on each power supply Combined PWR-C45-9000W with Triple 220V inputs on each power supply Combined PWR-C45-6000W with Single 220V inputs on each power supply Combined PWR-C45-6000W with three 220V inputs Combined PWR-C45-6000W with Dual 220V inputs on each power supply Line Card Slots 8 Rack Units 14

WARNING : Combined mode does not provide power supply redundancy. In combined mode, if one of the power supplies fails, the system will power down modules until the system power allocation is under the power budget of the remaining power supply NOTE : PWR-C45-1400DC-P supply should be used in conjunction with an AC powered DC UPS. For more information, click <a href= "javascript:openlargepopup('help.jsp#q')">tutorial/q&a</a>

Power Supply Details Minimum Power Supply Percentage of Power used Power Remaining (W) Current for this PSU(A) Current Used (A) Current Remaining (A) Combined 1000 Watt - Data Only Data:77.10% Data:381.68 Data:138.92 Data:31.81 Other Power Supply Options Percentage of Power used Power Remaining(W) Current for This PSU(A) Current Used (A) Current Remaining (A) Combined 1300 Watt Data:77.10% 1667.00 Data:138.92 -- PoE:25.63 Single/Redundant 1400 Watt - Data Only Data:94.51% Data:74.68 Data:113.33 Data:6.22 Combined 1400 Watt - Data Only Data:51.97% Data:1187.68 Data:206.08 Data:98.97 Single/Redundant 2800 Watt Data:94.51% Data:74.68 Data:113.33 Data:6.22 PoE:1400.00 PoE:26.92 PoE:26.92 Combined 2800 Watt Data:51.97% Data:1187.68 Data:206.08 Data:98.97 PoE:2333.00 PoE:44.87 PoE:44.87 4200W with a Single 220V input Data:94.51% Data:74.68 PoE:1850.00 Data:113.33 PoE:35.58 Data:6.22 PoE:35.58 4200W with a dual 220V input Data:94.51% Data:74.68 PoE:3700.00 Data:113.33 PoE:71.15 Data:6.22 PoE:71.15

Combined PWR-C45-4200W with single 220V inputs on each power supply. Data:58.42% Data:914.68 PoE:3100.00 Data:183.33 PoE:59.62 Data:76.22 PoE:59.62 Combined PWR-C45-4200W with dual 220V inputs on each power supply. (Up to 5,500Watts protected. See FAQ) Data:58.42% Data:914.68 PoE:6200.00 Data:183.33 PoE:119.23 Data:76.22 PoE:119.23 Combined PWR-C45-4200W with three 220 volt inputs. (Up to 5,500Watts protected, see FAQ). Data:58.42% Data:914.68 PoE:4700.00 Data:183.33 PoE:90.38 Data:76.22 PoE:90.38 PWR-C45-1400DC-P Data:94.51% Data:74.68 Data:113.33 Data:6.22 PoE:7220.00 PoE:138.85 PoE:138.85 9000W with a Single 220V input Data:88.04% Data:174.68 PoE:2500.00 Data:121.67 PoE:48.08 Data:14.56 PoE:48.08 9000W with a Dual 220V input Data:65.58% Data:674.68 PoE:5000.00 Data:163.33 PoE:96.15 Data:56.22 PoE:96.15 9000W with a Triple 220V input Data:65.58% Data:674.68 PoE:7500.00 Data:163.33 PoE:144.23 Data:56.22 PoE:144.23 6000W with a Single 220V input Data:58.42% Data:914.68 PoE:2400.00 Data:183.33 PoE:46.15 Data:76.22 PoE:46.15

6000W with a Dual 220V input Data:58.42% Data:914.68 PoE:4800.00 Data:183.33 PoE:92.31 Data:76.22 PoE:92.31 Combined PWR-C45-9000W with Single 220V inputs on each power supply Data:48.91% Data:1342.68 PoE:4150.00 Data:219.00 PoE:79.81 Data:111.89 PoE:79.81 Combined PWR-C45-9000W with Five 220V inputs Data:43.72% Data:1654.68 PoE:11250.00 Data:245.00 PoE:216.35 Data:137.89 PoE:216.35 Combined PWR-C45-9000W with Dual 220V inputs on each power supply Data:34.17% Data:2476.68 PoE:8300.00 Data:313.50 PoE:159.62 Data:206.39 PoE:159.62 Combined PWR-C45-9000W with Triple 220V inputs on each power supply Data:34.17% Data:2476.68 PoE:14400.00 Data:313.50 PoE:276.92 Data:206.39 PoE:276.92 Combined PWR-C45-6000W with Single 220V inputs on each power supply Data:32.13% Data:2714.68 PoE:4360.00 Data:333.33 PoE:83.85 Data:226.22 PoE:83.85 Combined PWR-C45-6000W with three 220V inputs Data:32.13% Data:2714.68 PoE:6600.00 Data:333.33 PoE:126.92 Data:226.22 PoE:126.92 Combined PWR-C45-6000W with Dual 220V inputs on each power supply Data:32.13% Data:2714.68 PoE:8700.00 Data:333.33 PoE:167.31 Data:226.22 PoE:167.31

Configuration Details Slot Line Card Output Current (A) Output Power (W) Typical Power Used (W) Heat Dissipation (BTU/Hr) Chassis WS-C4510R+E 21.25 255.00 204.00 1024.50 1 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 2 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 3 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 4 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 5 WS-X45-SUP7-E 23.30 279.60 223.68 1123.33 6 --EMPTY-SLOT-- 0.00 0.00 0.00 0.00 7 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 8 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 9 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 10 WS-X4748-RJ45-E 7.82 93.84 75.07 377.02 Output Current (A) Output Power (W) Typical Power Used (W) Heat Dissipation (BTU/Hr) Total 107.11 1285.32 1028.26 5163.96 NOTE : Output Power is the amount of power delivered from the Power Supply to the Catalyst 4500-E. To figure Input Power, divide output power by.85 (typical efficiency of the power supplies). NOTE : Output Power and Heat Dissipation numbers computed by the Cisco Power Calculator are maximum values and can be used for facility power and cooling capacity planning. These figures are not indicative of the actual power draw or heat dissipation. Typical power draw is about 20% lower than the maximum value shown. Also note that most of power allocated for PoE devices is dissipated at the end points.