Similar documents
The Use of Conduction Tracers Vs Bare Tracers Metric Version

Vacuum gearbox HET Gear

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Improve Steam Turbine Efficiency

Energy Saving by Implementation of Intelligent Systems in Lighting Abstract 2. Analysis of Outdoor Lighting Systems 1.

Hot Gas Stand durability tests for Turbine Housing design validation

The Pivotrol Pump Patented Selection and Sizing

Variable Air Volume (VAV) Pressure Independent Control

Table of Contents. Equipment Summary...3. Performance and Value Vs. New Equipment...3. Reliability.. 3

Waste Lubricating Oil Purification and Recovery

Delayed Coking. Process Overview

NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India.

SOAPP-CT.25 WorkStation 11/1/00. Equipment List Project: Sample Outputs Conceptual Design: Cogen, 1 x 27 MW, NG, Quarterly

A Guide to the medium General Service. BC Hydro Last Updated: February 24, 2012

COST ANALYSIS FOR BRIDGE AND CULVERT. Essam A. Mostafa

ELECTRIC POWER RESEARCH INSITUTE (EPRI) 2011 CONDENSER TECHNOLOGY CONFERENCE AUGUST 3-4, 2011, CHICAGO, ILLINOIS

TECHNICAL MANUAL MT064

Wagon repair workshop Jhansi Under North Central Railway. Workshop budget Rs Crores. Established in year 1889

Conventional Steam tracing

Delayed coking process as a way to increase crude conversion at JSOC Bashneft. Dmitry Maltsev Arthur Galiakbirov Gennady Valyavin April 2015

Energy Conservation Opportunities in Steam & Condensate Network. Forbes Marshall Pvt Ltd 1

On-Line Process Analyzers: Potential Uses and Applications

Increased flexibility of refineries by O 2 enrichment. Sulphur recovery and new opportunities.

The Enhanced Platform

FUEL EFFICIENCY CASE STUDY

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

LED lighting of Residential Areas - The economical option for Local Authorities. By Daniel Kasper and Johann Schleritzko

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

LIQUID MEASUREMENT STATION DESIGN Class No

PEIRCE SMITH CONVERTER HOOD IMPROVEMENTS AT BHP COPPER

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070

L.A. Maritime describes the operation of Aquametro Fuel-Switching Devices

Final Written Examination.

Level 7 Post Graduate Diploma in Engineering Power System Economics and Planning

ECTOS Deliverable 4. European Commission. Fifth Framework For Research And Development

DESIGN GUIDE FOR STEAM TRACING APPLICATIONS. THERMON The Heat Tracing Specialists

Gauges, Sight Glasses and Vacuum Breakers

In-House paper on Implementation of Telescopic Tariffs in LMV-6 category

Introduction to Condition-Based Maintenance Best Practices

Relative Power Factor Correction costs

ExxonMobil SYU LFC Interim Trucking Industrial Risk Analysis

Kapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing

Southern California Edison Rule 21 Storage Charging Interconnection Load Process Guide. Version 1.1

When should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy

Converting Visbreakers to Delayed Cokers - An Opportunity for European Refiners

Top Mount Installation for DP Flowmeters in Steam Service

Commissioning and Initial Shipboard Operation of Hydrocurrent 125 KW Marine Heat Recovery System

Electrical Depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC CURRENT SYSTEM

Alfa Laval s new FCM One is a single answer to today s fuel conditioning challenges

All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines

CATERPILLAR 3516B DP2 System

Уверенная модернизация

MANUFACTURER OF INDUSTRIAL STEAM BOILER

Docket No EI Date: May 22, 2014

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS

PLACE FOR TITLE. Improving Reliability and Reducing Steam Leakage in General Purpose AUTHORS Steam Turbines with Floating Brush Seals

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

Generator Efficiency Optimization at Remote Sites

USES FOR RECYCLED OIL

Less Emissions Through Waste Heat Recovery

Thermodynamic comparison and Dynamic Simulation of Direct and Indirect Solar ORC system with PCM storage

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Technologies & Economics

Contact person: Pablo Taboada Mobile:

SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) QUESTION BANK UNIT I I.C ENGINES

Mini refinery feasibility study

MHI Integrally Geared Type Compressor for Large Capacity Application and Process Gas Application

WM2015 Conference, March 15-19, 2015, Phoenix, Arizona, USA

As diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.

SECTION Pressure & Temperature Control

CYCLO OIL LLC Used Oil Re-refining Plant

Power Interchange System for Reuse of Regenerative Electric Power

Document Code: 1 (8) Issuing date: Status:

Switchgear and Distribution Systems for Engineers and Technicians

Utilisation of High CO2- Content Flare Gas for Steam and Electricity Generation. Santiago Pástor Technical Manager PETROBRAS Ecuador December 2008

Economics of Steam Traction for the Transportation of Coal by Rail. Chris Newman Beijing, China

opportunities and costs to upgrade the quality of automotive diesel fuel

USP&E Item # Manufacturer Model Year Hours Wattage(kW) Frequency Fuel Type Quantity Less Than Selling for Scope of Supply Notes

Method to tie feeding cables for energy conservation

ENERGY MANAGEMENT 4/22/2014. What are your approximate yearly energy costs? (Electricity, natural gas, etc.)

PUBLIC SERVICE COMMISSION OF WEST VIRGINIA %% CHARLESTON

D^r i^k_hkfzg\^ bg]b\zmhkl _hk <hgl^i mkzrl IZkZf^m^kl =^lb`g M^lm kng <hg\enlbhgl MZ[e^, DZnlabd Fhl\Z K^_^k^g\^l D^gm FZahg

STUDY TO COMPARE TANK CAR ON SPOT LOADING SYSTEMS WITH SERIAL LOADING SYSTEMS. Dipl.-Ing. SCHERZER GmbH LOADING YOUR FUEL

Installation manual. Cooling system. Industrial engines DC09, DC13, DC16 OC16. 01:05 Issue 12 en-gb. Scania CV AB 2018, Sweden

USP&E Item # Manufacturer Model Year Hours Wattage(kW) Frequency Fuel Type Quantity Less Than Selling for Scope of Supply Notes

PERFORMANCE AND EMISSION ANALYSIS OF DIESEL ENGINE BY INJECTING DIETHYL ETHER WITH AND WITHOUT EGR USING DPF

TECHNICAL REFERENCE CLEANING POWER GUIDELINES TANKJET TANK CLEANER OVERVIEW BY TANK DIAMETER OPTIMIZING TANK CLEANING OPERATIONS

NUMBER: S.M. REF.: Listed in Table 1 ENGINE: DD13 DATE: July 2009

UPGRADER FOR HEAVY, EXTRA-HEAVY CRUDE/BITUMEN AND RESIDUAL FRACTIONS

For Sale: Used Steam Turbine Generator Sets. Offer Ref. STG MW Steam Turbine Genset Condensing-Extraction type

Current State of the Renewable Energy in Kyushu Electric Power and Our Future Plan. Kyushu Electric Power Co. Inc. June 8, 2017

KNOWLEDGE

The Role of a New FCC Gasoline Three-Cut Splitter in Transformation of Crude Oil Hydrocarbons in CRC

Routine Compressor Maintenance

Operation and Maintenance of different valve types

LEISTRITZ PUMPEN GMBH. Screw Pumps & Systems. Oil & Gas

Increased recovery of straight-run

A Recommended Approach to Pipe Stress Analysis to Avoid Compressor Piping Integrity Risk

Transcription:

Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System For SUITED COSTAL / EXPORT REFINERY PROJECTS 5-Km 450 NB (18 Dia.) Long Pipe Line From SEZ Tank-farm to DTA Tank-farm for Maintaining Vacuum Residue (VR) Fluid at 200 deg.c, Prepared By Homi R. Mullan March 02, 2008

Technical & Commercial Evaluation Study Of Steam Tracing System V/s Skin Effect Heating System Electric Heat Tracing SECT, System Useful For Refinery Projects For 5-Km 450 NB (18 Dia.) Long Pipe Line from SEZ Tank-farm to DTA Tank-farm for maintaining Vacuum Residue (VR) Fluid at 200-deg.C, TABLE OF CONTENT PAGE 1.0 Introduction... 4 General...4 Summary of Total Installed Cost (TIC) and Total Operating Cost (TOC) of Steam Tracing System and SECT Electric Heat Tracing System...4 Total Installed Cost (TIC)...4 Total Operating Cost (TOC)...5 Energy Consumption Rate...5 2.0 Total Installed Cost (TIC) of Steam Tracing System... 7 2.1 Steam Tracers...7 2.2 Manifolds and Branch Connection Pipes...7 2.3 Steam Feeding Header...8 2.4 Steam Transport Header...8 2.5 Thermal Bonding Material for Steam Tracers...9 3.0 Total Operating Cost (TOC) of Steam Tracing System... 10

3.1 Steam Consumption from Steam Tracer circuits...10 3.2 Steam Consumption from Manifolds and Branch Lines....11 3.3 Steam Consumption from 5,000 M Steam Feeding Header...11 3.4 Steam Consumption Due to Steam Leakages...11 3.5 Maintenance Cost for Steam Tracing System...12 3.6 Replacement Cost for Steam Tracing System...12 3.7 Summary of Operating Cost for Steam Tracing System...12 4.0 Energy Consumption Comparison and Cost... 13 4.1 Energy Consumption for SECT Electric Heat Tracing...13 4.2 Energy Consumption for Steam Tracing System...13 5.0 Conclusion Summary... 14 6.0 Reference... 15 1. Total Installed Cost for Steam Tracing System: Annexure-4...15 2. Total Operating Cost for Steam Tracing System: Annexure-5...15 3. Operating Energy & Cost for SECT Electric Heat Tracing system: Annexure-6...15 4. The Energy Requirements of Steam Traps. [Spirax-Sarco Publication]...15 5. Steam Condensed and Watt Heat Loss per Meter of Tracer,Table 36, page 328, ThermalInsulation Handbook- by Turner & Malloy...15 6. Designing Steam Tracing, April 3, 1972/ Chemical Engineering by Carl G. Bertram, Vikram J. Desai & Edward Interess, The Bedger Co....15 7. Steam Tracing pages 32 to 37, Steam In The Oil & Chemical Industries...15

Page 4 1.0 Introduction General For High Temperature (200 O C or thereabout) long transfer lines carrying high viscosity and high pour point fluids such as Vacuum Residue, as a norm worldwide, uses Steam Tracing by and large, and Electric heat Tracing System where Steam is not available and/or it is difficult to carry at long distances. This Study presents economics of Skin Effect Electrical Tracing System (SECT), over the Steam Tracing option. This study presents the options for Coastal Refineries undergoing modernization and entering into export of High Pour Point and High Viscosity Fluids such as hot Vacuum Residue (VR) Refineries have availability of High Pressure Steam at 42.2 kg/cm 2 (g), the option of using steam tracing is primarily explored on the basis of perceived Reliability, and Technical & Economic consideration. For this, a selective study is prepared for the 5,000 M section running from Special Export Zone (SEZ) tank-farm to Duty Tariff Area (DTA) tank-farm, a line which will run outside of refinery battery limits and which has to cross below the railway tracks and road crossings, at several locations along the route. The Installation Cost and Energy Consumption cost for this section are summarized below. Summary of Total Installed Cost (TIC) and Total Operating Cost (TOC) of Steam Tracing System and SECT Electric Heat Tracing System. Total Installed Cost (TIC) STEAM TRACING Rs. Lacs SECT ELECTRIC Rs. Lacs 654 285 (Add Cost of Power Cable to Transformers)

Page 5 Total Operating Cost (TOC) (8,000 operating hours /year) STEAM TRACING Rs. Lacs/Year SECT ELECTRIC Rs. Lacs/Year 658 112 [CONSULTANT Steam Cost Ref.: @ USD 15.8 per MT; and Power Cost @USD 67 MW] Energy Consumption Rate (* At Annual mean average ambient temperature of 25 O C) STEAM TRACING * SECT ELECTRIC Kg. Steam / hour kwh 11,586 469 The Total Installed Cost (TIC) figures shown above are suggestive that the SECT Electric Tracing System will cost less than half the Steam Tracing Total Installed Cost. Again, on the Total Operating Cost, the figures shown are suggestive that even if the installed cost for Steam Tracing System was Nil, the SECT Electric Tracing Cost would be recovered within the first year of operation, based on the Total Operating Cost Savings. From the Energy angle, 11.586 MT of Steam from a Thermal Power Plant would generate 811 kwh of Power (@ 1 MT Steam generates 70kW); of which 70%, i.e. 567.7 kwh would be generated in a Condensing Turbine cycle. Accordingly, there would be substantial savings in Power if SECT Electric Heat Tracing system is opted over Steam Tracing System. Furthermore, it is increasingly being established worldwide to Electrically Heat Trace long transfer lines carrying High viscosity and High Pour Point fluids at around 200 O C.

Page 6 For better understanding of the Steam Tracing System Design & Costs, the following section deals with the basic logical steps and criteria considered in arriving at these Total Cost concepts towards Installation and Operating aspects of the Two Heat Tracing Options, Steam and SECT Electric.

Page 7 2.0 Total Installed Cost (TIC) of Steam Tracing System The installation cost for Steam Tracing system for a 5,000 M 450NB (18 dia.) pipeline at maintain temperature of 200 O C, considers the costs towards: a) Steam tracers along with its Steam Trap assemblies. b) Steam Manifolds and steam supply connection from manifold to tracer inlet; and, Condensate discharge manifolds and connections from the tracer steam trap discharge to the condensate Manifold. c) Steam Header, which runs parallel to VR pipeline, to feed steam supply for the steam tracing system along the 5,000 M run. d) Steam Header to transport Steam from Refinery battery limit to the SEZ tankfarm at a distance of 2,500 M length at 42.2 Kg/cm 2 (g) e) Cost of Thermal bonding material, for the required heat output from steam tracers. The standards and data considered for the above stated components of the steam tracing system are explained below. 2.1 Steam Tracers The standards / norms considered for steam tracer installation are: a. Operating Steam Pressure of 42.2 Kg/cm 2 (g) [by CONSULTANT] b. Steam Tracer size 15NB carbon steel c. Ratio of number of thermally BONDED Steam tracers to a unit meter length of 450 NB VR pipe is Six (6) [by CONSULTANT, as the best judgment, since the BARE steam tracers standards available were for maximum maintain temperature of around 149 O C only] d. Steam Trapping distance interval at every 60 M [by CONSULTANT] e. Cost of 15 NB tracer CS pipe at Rs.300/= per meter [by CONSULTANT] f. Condensate to be discharged to open French Drains. Hence, no closed loop with a by-pass required for steam trap assembly. Thus, the total requirement is of 30,000 M of 15 NB Steam tracers for a 5,000 M of 450NB (18 dia) VR pipe line. 2.2 Manifolds and Branch Connection Pipes a. Manifold of 40NB pipe to feed 12 nos. of steam tracing circuit is considered [handbook standards / industry practice] b. Each Steam supply manifold will have a steam trap assembly.

Page 8 c. Branch line connections from the steam manifold to steam tracer inlet; and branch connection from steam trap outlet to condensate manifold, each of which has been considered to be of 2 M. d. Each manifold shall be at every 60 M interval. e. Thermal insulation cost for the manifold and branch connecting pipes has been considered. 2.3 Steam Feeding Header a. Steam feeding header of 150NB (6 dia.) to carry estimated 11.5 MT steam per hour at 42.2 Kg/cm 2 (g) has been considered and found suitable [by CONSULTANT b. Steam feeding header shall also be drained every 6M [by CONSULTANT] c. The condensate discharge from steam strap on steam header is considered to be led into a French Pit [by CONSULTANT] 2.4 Steam Transport Header The steam shall be transported from the Refinery battery limit to the SEZ tank farm. a. Steam transport header of 150NB (6 dia.) to carry estimated 11.5 MT steam per hour at 42.2 Kg/cm 2 (g) has been considered and found suitable [by CONSULTANT] REFINERY BATTERY LIMIT Steam transport header 150NB at 42.2 kg/cm 2 (g) [2,500 M] Steam transport header 150NB at 42.2 kg/cm 2 (g) [5,000 M] SEZ Tank Farm VR Steam Traced Pipe 450 NB at 200 O C [5,000 M] DTA Tank-farm Figure-1: General routing of Steam Headers & VR Line

Page 9 2.5 Thermal Bonding Material for Steam Tracers For an effort to possibly maintain VR pipe at 200 O C, thermally bonding material between steam tracer and VR pipe, would be desirable.

Page 10 3.0 Total Operating Cost (TOC) of Steam Tracing System The Operating cost for Steam Tracing system for a 5,000 M 450NB (18 dia.) at maintain temperature of 200 O C, considers the costs towards: a) Steam consumption due to heat transferred to process fluid by thermally bonded Steam tracer; heat loss from the steam tracer to ambient through thermal insulation; steam required for operation of steam trap; and radiation loss from valves and fittings. b) Steam consumption due to Radiation losses to ambient from Steam & Condensate Manifolds; and steam & condensate connection pipes to respective manifolds. c) Radiation losses Steam Feeding Header, which runs parallel to VR pipeline, to transport steam supply for the steam tracing system along the 5,000 M run; losses through the steam trap assemblies. d) Radiation losses from Steam Transport Header to transport Steam from Refinery battery limit to the SEZ tank-farm of 2,500 M length at 42.2 Kg/cm 2 (g) e) Steam Leakages from the entire steam supply and steam tracing network. f) Maintenance Cost g) Replacement Cost. The standards and data considered for the above stated components for Operating Costs of the steam tracing system are explained below. 3.1 Steam Consumption from Steam Tracer circuits. a) Steam consumption from steam tracer forms the major component of the total steam tracing operating energy cost. Steam consumption towards uncontrolled heat to process fluid is the most significant component. b) This study has considered steam consumption from thermally bonded 15 NB steam tracer at near about 42.2 Kg/cm 2 (g) at 0.33991 KG-HR- MTR [.09442 G/S-M] from near to similar conditions corresponding to pipe maintain temperature at 137.6 O C from Thermal Insulation Handbook by Turner & Malloy. Research figures from similar study shows steam consumption from thermally bonded steam tracer at 0.34898 KG-HR-MTR [0.234 lb/(hr) (ft)] for a 10-inch PAN line maintenance at 149 O C, ref. Design Steam Tracing Carl Bertram, Vikram Desai and Edward I- CHEMICAL ENGINEERING April 03, 1972. Basic heat transfer study shows similar steam consumption from thermally bonded steam tracer.

Page 11 c) The energy requirement of Thermodynamic steam trap considered under reasonable load is at 0.25 Kg/hour Steam. Under No-load condition, the energy requirement would be 0.75 kg/hour Steam. [Ref. A Spirax-Sarco guide on Steam and Steam Trapping ] 3.2 Steam Consumption from Manifolds and Branch Lines. a) Radiation Losses from an insulated: 40 NB Manifold considered is at 0.052 Kg/(hr)(mtr) steam; 15 NB connecting lines at.047 Kg/(hr) (mtr) steam; 15NB Valves at.023 Kg/(hr) (mtr) steam; 3.3 Steam Consumption from 5,000 M Steam Feeding Header a) Radiation heat loss from an Insulated 150 NB Steam feeding header is considered at 0.106 Kg/(hr)(mtr) steam. b) Likewise the losses from steam trap assemblies, as explained above are also considered. 3.4 Steam Consumption Due to Steam Leakages Steam leakages are synonymous with Steam Systems. The industry norm is that one leak would occur from Steam lines at an average of every 30 meters once a year, and the same has been considered. Accordingly, the study considers the following. a) Steam leak at 14 kg/cm 2 (g) from a 1.5 mm diameter leak, from available chart, is considered at 14 kg/hr steam per leakage. Considering the project operating pressure at 42.2 kg/cm 2 (g), the steam loss due to steam leakages would be higher than the estimated quantity for this study. b) The average time allowed for steam leakage to continue before the steam leak is fixed, is considered as 96 hours (4 days). The actual steam leakage considered could be much higher than the estimated steam leakage considered for this study, as it may take a longer period to detect and rectify for a remotely located line, such as this one.

Page 12 3.5 Maintenance Cost for Steam Tracing System Checking of Valves, Steam Traps once in a month, and to attend to repairs would involve: a) Estimated maintenance time per Steam Circuits is 12 Man-hours per year. b) Cost per Man-hour considered is Rs.100 per Man-hour. This could vary from organization to organization. 3.6 Replacement Cost for Steam Tracing System The operating life of Steam tracing system is considered as 10-years, and accordingly an average of 10% per year of installed cost is considered as Replacement cost. 3.7 Summary of Operating Cost for Steam Tracing System Steam Consumption Kg/hour Steam Cost Annual Rs. Lacs a Steam Tracer circuits 10,334 587 b Manifolds & Branch Connections 194 11 c Steam and Condensate Lines 565 32 d Steam Leaks 210 12 e Maintenance 8 f Replacement 51

Page 13 4.0 Energy Consumption Comparison and Cost 4.1 Energy Consumption for SECT Electric Heat Tracing a) The Energy consumption for SECT Electric Heat Tracing is considered at Annual Mean Average ambient of 25 O C, to estimate the annual energy consumption. b) Design Margin loading has not been considered for estimating the annual energy consumption. c) The Energy Cost for Electrical Power considered is Rs..3.0 kwh [by CONSULTANT] d) Annual Operating hours is considered at 8000-hours. e) Accordingly, the Rate of Power consumption for 450NB (18 dia.) Pipe of 5,000 M length at 200OC is calculated to be 469 kwh. f) Accordingly, the Annual Power Energy cost is calculated to be at Rs.112 Lacs. g) The installed electric load has been considered with a 25% Design margin, which is very near about the required to be done. Moreover, the SECT Electric Heat Tracing controls the Energy Power input very near to the actual Heat Loss taking place. Thus, the efficiency of an Electric Heat Tracing system is greater than 90%. 4.2 Energy Consumption for Steam Tracing System a) The Energy consumption for Steam Tracing system is calculated based on the estimated / calculated: i) Heat input into the Fluid by thermally bonded steam tracer; ii) Heat loss from the steam tracers to ambient through thermal insulation; iii) Radiation and Steam leakages from the entire steam system i.e. Steam Transport and feeding Headers, Manifolds, Pipes and Fittings. b) The Energy Cost for Steam is considered at Rs..0.71 kg steam/hour [by CONSULTANT @ USD15.8 per MT] c) Steam Tracing is generally not shut off and opened frequently, as starting of the steam supply is an operation in itself. Therefore, efforts in controlling temperature from a steam traced lines can be done only marginally at a very enormous cost. d) Against the work required steam load of 1087 kg steam / hour, the Steam energy expanded to do the work is 11,303 kg steam/hour, thus the Steam Tracing System efficiency would run below 10%.

Page 14 5.0 Conclusion Summary Note, this study has been prepared for Technical and Economic consideration in selection of the choice between Steam Tracing system and an Electric Heat Tracing system. Hence, the design and costs figures considered for a Steam Tracing system are on a conservative side. a) Electric Heat Tracing and in particular the Skin Effect Heating system such as SECT is the proven and established mode of heat tracing High Maintain Temperature (200 O C), High Viscosity and High Pour Point fluids long distance pipelines, worldwide. b) The Electric Heat Tracing system will be quicker to install compared to Steam Tracing system. c) Total Installation Cost of SECT Electric Heat Tracing system will be less than half the cost of a Steam Tracing system. d) Total Operating Cost of SECT electric heat tracing system will be a fraction of cost a Steam Tracing system. e) For SECT Electric Heat Tracing System Design & Cost Refer to SECT Technical Design and Budgetary Estimate Report Rev.02 of October 27, 2006

Page 15 6.0 Reference 1. Total Installed Cost for Steam Tracing System: Annexure-4 2. Total Operating Cost for Steam Tracing System: Annexure-5 3. Operating Energy & Cost for SECT Electric Heat Tracing system: Annexure-6 4. The Energy Requirements of Steam Traps. [Spirax-Sarco Publication] 5. Steam Condensed and Watt Heat Loss per Meter of Tracer,Table 36, page 328, ThermalInsulation Handbook- by Turner & Malloy 6. Designing Steam Tracing, April 3, 1972/ Chemical Engineering by Carl G. Bertram, Vikram J. Desai & Edward Interess, The Bedger Co. 7. Steam Tracing pages 32 to 37, Steam In The Oil & Chemical Industries.