1 Table of Contents Section Page Equipment Summary Performance and Value Vs. New Equipment Reliability.. 3 Steam Turbine Design Details and Capabilities....5 Steam Turbine Application and Reapplication Summary Gearbox Design Details...6 Generator Design Details....6 Turbine Control System...7 Unit Supervisory Instrumentation. 7 Generator Control System..7 Auxiliary Systems. 8 Technical Support and Contact Information....8 Appendix 1- Unit Data..9 Appendix 2- Unit Pictures.. 25
2 e Page 2 Equipment Summary This unit for sale is a 2005 vintage 6,957 kw Dresser Rand steam turbine generator set with a Flender reduction gearbox and GE 4 pole, synchronous generator. The unit started operation in 2007 and was operated only until 2009 when it was shut down due to economic reasons. Pictures of the installed unit are located in Appendix 2 of this report. Performance and Value Vs. New Equipment Based on the performance table supplied, with the unit new and clean overall turbine generator efficiency of the unit at its max output point of 6,957 kw s is calculated to be 74.5%. This efficiency is what would be expected of any modern non-condensing steam turbine of this size, energy range, and steam path design. A new unit would not yield any more significant performance improvements over this unit design to warrant the huge price increase for new equipment over this used steam turbine generator For example, if new equipment could get a 1% increase in performance over this used unit (a larger than expected increase over this used unit) that would equate to a gain of 70 kw s. At $.05/kw-hr that would equal about $30,000/year in extra generation from increased efficiency. The price difference between new and this used unit is $2,750,000. Therefore it would take 91.7 years to recover the extra cost of the new unit to gain the more than expected 1% in performance! Reliability As with any piece of equipment the incidents of failures and failure rate are highest at both the beginning and at the end of its life as shown below in a typical bath tub curve and cumulative failure rate curve. Since this unit was in operation for 3-4 years, the unit would fall into the lowest potential failure rate bracket due to its age and actual years of service. Based on these typical curves, and the design life of a steam turbine of years, the reliability should be better than a new unit since its past its formative years for failures and at the lowest instantaneous failure rate.
3 Figure 1-Typical Equipment Reliability and Life Cycle Curves e Page 3
4 e Page 4 Steam Turbine Design Details and Capabilities Inlet Section The steam turbine was designed and built by Dresser Rand and is a 7 stage impulse design straight non condensing steam turbine This unit has a unique 2 pressure level induction, but this feature allows flexibility for multiple steam inlet conditions for reapplication. The main steam inlet is 850psig/902F and the inlet sized for 130,000 pph of steam flow. The inlet flange is 8-900# and is oversized such that it could be upgraded to pass up to 260,000 pph of 850psig/902F steam, a 100 % increase over design, if needed for reapplication. If your application has steam up to 850psig/902F the unit could be operated without 600 psig induction steam to run at the full generator capability at this inlet pressure and temperature. Induction Section Directly after stage 2, there is a second pressure level induction at 620 psig/835f with a design flow into the unit of 90,000 pph through a second inlet nozzle with 4 control valves and its own trip throttle valve. The inlet flange on this induction section is rated for 6-600# and is oversized such that if the unit was upgraded it could potentially pass up to 130,000 pph of 620 psig/835f or an increase of 44% over design induction conditions. A more typical industrial main steam header/boiler will run at 600 psig/750f. With these steam contains the unit could pass about 95,000 pph through the existing design induction nozzle. If you required more 600 psig/750f steam, the unit could be made to pass up to 140,000 pph of 600 psig/750f steam through the induction or 47% increase in flow. The unit can be operated solely on 600 psig steam if required for reapplication. In most any reapplication situation the inlet steam would be introduced into the inlet section of the unit, rather than the induction section of this unit, and the induction would be removed from service. The inlet flow passing area of the unit is larger than the induction and could pass more flow, more efficiently than the induction section. Exhaust Section The exhaust section of this machine is designed to pass approx. 217,000 pph at an exhaust pressure of between psig. The total flow is a combination of inlet and induction steam flow that goes to the exhaust and then to satisfy plant process. The exhaust flange of this unit is a # rating. If required, the exhaust section could pass up to about 420,000 pph of 220 psig steam or approx. 94% increase over design exhaust flow. So the exhaust is well oversized for most any inlet flow that could be put to this unit. This exhaust section, although designed for psig can be modified to run at a multitude of pressures, such as 150 psig or less to suit your process steam requirements in your facility. team Turbine Application and Re-application Summary As you can see in the above evaluation this unit can run from an inlet of 850psig/902F to 620psig/835F or lower inlet conditions. The multiple inlets, with materials to suit these higher
5 e Page 5 temperatures and pressures suit the unit to a variety of inlet conditions and allow the unit to run efficiently throughout these large range of conditions. The unit can be solely operated from 850 psig steam, 600 psig steam, or most any other steam conditions below 850 psig/902f. As long at the inlet pressure and temperature stay at or below 850 psig/902f (casing design and material limits) the turbine is suitable for those or lower conditions for a wide variety of flows. Some of the increased flows or changed inlet conditions may or may not require unit modifications (not every application change requires hardware changes) but rather a quick review by an experienced engineer to determine the output and suitability at these off design conditions. All steam condition changes can be evaluated on a case by case basis. In most every case the potential turbine uprate capability is always larger than the generator capacity. The maximum generator operating condition for this unit is 8,235 kw at a 1.0 PF. If you can operate at unity power factor in your facility the generator can generate 8,235 kw based on the design data provided. The turbine flows could be increased to max out the generator at its unity power factor rating. Gearbox Design Details The gearbox was designed and built by Flender. This gearbox is a single helical, high speed reduction gear which reduces the turbine operating speed from 6,000 rpm to 1,800, or a 3.33:1 gear ratio, for use with the 4 pole generator. The driver rating for this gear is 7,350 kw s with a max power rating of 9,604 kw s and has an AGMA service factor of 1.3 and a full load efficiency of 98.6%. The gearbox is full instrument with modern supervisory instrumentation. The gearbox design data is located in the Appendix 1 of to this report. Generator Design Details The generator is an 8,235 kva, 60 HZ, 13,800 volt, 1,800 RPM, 4 pole generator designed and built by General Electric. The generator is a TEWAC type with a design cooling water temperature of 30 C. The generator field is a salient 4 pole design. The unit is rated at 7,000 kw at.85 power factor but can be operated at unity power factor to create up to 8,235 kw of real power. The unit is VPI treated to ensure maximum resistance to moisture intrusion, void free insulation, and the ultimate in reliability. The unit is full instrumented to allow for monitoring, alarming and tripping as required. The exciter for the unit is also a GE deign, brushless excitation system for which simplifies design and eliminates the need for brush and collector ring maintenance and changes. The generator design data and performance information is located in the Appendix 1 of this report. The data provided should be sufficient for any request by your utility for their transmission study. Turbine Control System This unit has a modern Woodward 505E digital turbine control system and a 2 of 3 voting Woodward ProTech 203 for additional overspeed protection. The inlet control valves are
6 operated by an 8 Woodward EHPC while the induction control valves are individually operated by 4 Valtek pneumatic control valves that are integrated into the Woodward 505E controller to control the 620 psig second pressure level induction into the turbine. The unit also has an Allen Bradley SLC 500 programmable logic controller and a Panelview HMI for logic, monitoring and control of the turbine auxiliary systems and operation. The turbine control system is integrated into the PLC controller for full operational capability of the unit from the panel and HMI. There is also a local control panel. A full bill of materials and P&ID is available if you would like to see all the controls and instrumentation included with this unit Unit Supervisory Instrumentation The set includes full unit supervisory instrumentation using a Bently Nevada 3300 series supervisory system for monitoring alarm and tripping and is integrated into the PLC and turbine-generator controls. There are both x and y vibration probes on all bearings, axial position, turbine keyphasor and bearing RTD s for bearing temperature monitoring. There are also local sight flows and temperature and pressure indicators in the required locations. A list of all supervisory instrumentation and devices included is available if requested. Generator Control System The generator has a brushless exciter with full excitation and control panel with Basler digital automatic voltage regulator. It also includes full generator, surge, neutral, and protection panels. Auxiliary Systems The combined turbine lube and control oil system is a modern design with (2) AC main oil pumps that provide lube and control oil and a DC emergency oil pump providing only lube oil to the unit in case of loss of AC power. The system has both duplex oil coolers and 10 micron stainless oil filters, both with isolation/transfer valves for serviceability while operating. The system has both stainless steel feed and drain piping for resistance to corrosion and the ultimate in oil delivery cleanliness to the unit. The unit is full instrumented for monitoring, operation and control. The unit piping has built in oil flushing provisions with blind flanges mounted on the feed pipes at the bearings to simplify setting up the unit for oil flushes. The gland seal condenser system is included with the unit and uses a steam jet ejector to maintain the vacuum in the end glands of the unit to eliminate steam leakage from the ends of the machine. The condenser is a shell and tube heat exchanger with manual control valves to set and maintain system vacuum for leak free operation. The GSC is instrumented to allow for proper operation and control. Technical Support and Contact Information The price of the unit includes limited technical support and engineering services to any potential buyer e Page 6
7 e Page 7 Appendix 1 Unit Data
8 Unit Nameplate e Page 8
9 Steam Turbine Data Sheets e Page 9
10 Steam Turbine Data Sheets e Page 10
11 Steam Turbine Data Sheets e Page 11
12 3D Model of Steam Turbine e Page 12
13 Unit Mechanical Outline e Page 13
14 STG Performance Table e Page 14
15 STG Performance Curve e Page 15
16 Steam Turbine Cross Section e Page 16
17 Reduction Gear Data e Page 17
18 Generator Data e Page 18
19 Generator Data e Page 19
20 Generator Data e Page 20
21 Generator Data e Page 21
22 Generator Data e Page 22
23 e Page 23 Appendix 2 Unit Pictures
24 e Page 24
25 e Page 25
26 e Page 26
27 e Page 27
28 e Page 28
29 e Page 29
30 e Page 30
31 e Page 31
32 e Page 32
Document Code: 1 (8) Issuing date: Status:
Document Code: 1 (8) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Employer: JJA Document title: SYSTEM DESCRIPTION TURBINE CONTROL Submitted for: Employer reference: Other information: Document
More informationSynchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd
Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan presenter Nathan Schachter SLC PLC Lubrication units Cooling Water DCS SUB BD Breaker SR469 GE STAT-XTOR PLC Field Application
More informationSynchronous motor control. 8/15/2007 Powerflow Technologies Inc 1
Synchronous motor control 8/15/2007 Powerflow Technologies Inc 1 PLC Lubrication units Cooling Water DCS PLC Dampers SUB BD Breaker Protection relay Field Application Kiln System Fan Hydraulic Unit Instrumentation
More informationMaintenance Differences Between Single Stage and Turbo Blowers. Proprietary Information
Maintenance Differences Between Single Stage and Turbo Blowers Objective: To give an overview on the maintenance requirements between the following blower Technologies Integral Geared Blowers Magnetic
More informationFor Sale: Used Steam Turbine Generator Sets. Offer Ref. STG MW Steam Turbine Genset Condensing-Extraction type
Sonnenberger Str.16 Tel. +49 (0) 611-701888 www.lohrmann.com 65193 Wiesbaden - Germany Fax +49 (0) 611-701895 info@lohrmann.com For Sale: Used Steam Turbine Generator Sets Offer Ref. STG - 25.02 10 MW
More information5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection
Bargh afshan alborz Amol Mazandaran Iran Tel: +98 (0)1212229599 Fax: +98 (0)1213239001 Email: ba_alborz@yahoo.com www.alborzgenerator.com 5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD)
More informationCCHMP Comments on ConocoPhillips Incident Report For 10/22/10 Flaring Event
CCHMP Comments on ConocoPhillips Incident Report For 10/22/10 Flaring Event The following comments relate to reviewing ConocoPhillip s RCA report received on 12/21/10. 1. The report identified that operators
More informationKARL SCHNELL GRINDER SPECIFICATION: KS Process Automat B 22 Type l
KARL SCHNELL GRINDER SPECIFICATION: KS Process Automat B 22 Type 250 300l Execution - total volume mixer bowl approx. 380 l, nominal volume approx. 300 l - stationary design, with four height adjustable
More informationROGERS MACHINERY COMPANY, INC
KOBELCO KNW SERIES Sample Specifications ROGERS MACHINERY COMPANY, INC WATER-COOLED, OIL-FREE AIR COMPRESSOR Frame 00 20-50 HP 2110_00.doc Effective: 03/24/17 Supersedes: 10-11-13 Page 1 of 8 1. SPECIFICATION
More informationSample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP
KOBELCO KNWA00 SERIES 1 of 8 1. SPECIFICATION SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all
More informationTECHNICAL SPECIFICATIONS DESCRIPTION: - CENTAC COMPRESSOR 2
TECHNICAL SPECIFICATIONS DESCRIPTION: - CENTAC COMPRESSOR 2 Description: The Centac 2 compressor is a multi-stage (3-stage) centrifugal air compressor. It has an output of approx 5000 to 6000 m 3 /hr (actual
More informationUD SERIES COMPRESSORS
UD SERIES COMPRESSORS INDUSTRIAL AIR COMPRESSOR 40-400 HP UPDRAFT MODELS Electric Motor - 460/575/3/60 standard (208/230/3/60 optional on most models) Motor Starter - 460 volt, full voltage magnetic starter
More informationabc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.
CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage
More informationWhen should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy
When should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy TMEIC Corporation Roanoke, VA, and Houston, TX 2/8/2013 When should
More informationAPPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS
APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS 29 JOB NO. GENERAL-PURPOSE STEAM TURBINE PURCHASE ORDER NO. DATA SHEET SPECIFICATION NO. SI UNITS REVISION NO. DATE PAGE 1 OF 3 BY ITEM NO. 1 APPLICABLE
More informationSteam Turbine Seal Rub
Steam Turbine Seal Rub Date : November 19, 2014 Steam Turbine Seal Rub Vibration data helps to identify a steam turbine seal rub. Sotirios Christofi Deputy Manager, Head of Mechanical Maintenance, Thessaloniki
More informationCATERPILLAR 3516B DP2 System
CATERPILLAR 3516B DP2 System CONTENTS System Overview 3 Offshore Rig or Ship DP2 Package 3 Main Generator Diesel Skid 3 Main Generator Diesel Engines 3 Instrument, Alarms and Automatic Start/Stop System
More informationPOWER FACTOR IMPROVEMENT CONCEPT FOR LARGE MOTORS
POWER FACTOR IMPROVEMENT CONCEPT FOR LARGE MOTORS POWERFLOW TECHNOLOGIES Inc 4031 FAIRVIEW ST, Burlington,Ontario, CANADA, L7L-2A4 905-336 2686, www.powerflowtechnologies.com 1 POWER FACTOR REQUIREMENTS
More informationHigh Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)
High Voltage Generators TM21-TG Series 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP) TMEIC has a proud and rich history of providing the latest generator technology for a broad range
More informationTurbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators
Turbogenerators With Top Performance for Steam and Gas Applications Specifically tailored 4-pole Synchronous Turbogenerators siemens.com / automation 2 Top Performance Turbogenerators for Steam and Gas
More informationMotor Protection Fundamentals. Motor Protection - Agenda
Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection
More informationTURBO-AIR 2000 Centrifugal Compressor
TURBO-AIR 2000 Centrifugal Compressor 100% oil-free air* *Per ISO 8573-1 certification Benefits of TURBO-AIR Compressors ISO 8573-1 CERTIFIED OIL-FREE AIR Prevents oil contamination of your system Limits
More informationGE Power Conversion. N3 Series Model N37 MV Induction Motor 4 Pole, 50Hz
GE Power Conversion N3 Series Model N37 MV Induction Motor 4 Pole, 50Hz High Power Density High Efficiency Low Vibration Low Noise More power in a smaller package. Built on extensive rotating machine experience.
More informationApplications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant
Parallex TM Slide System - It s the key to part load efficiencies far superior to twin screw compressors. Capacity and volume slides move independently of each other based on load, eliminating over or
More informationMedium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)
Medium Voltage Induction Motors 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP) series: Combining over 100 years of experience with innovative
More informationAppendix B6 Gas Turbine Unit Cause Codes
Appendix B6 Gas Turbine Unit Cause Codes GAS TURBINE UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Unit Codes 300 399 and 700 799) Cause Code BALANCE OF PLANT Ranges Page No. GENERATOR GAS TURBINE Electrical
More informationSPECIAL PURPOSE STEAM TURBINE SPECIFICATION SHEET ( )
SPECIAL PURPOSE STEAM TURBINE SPECIFICATION SHEET ( ) CLIENT : BY REV. 1 2 3 MADE PROJECT TITL E : CHKD CHKD JOB NO. : APVD APVD DOC. NO. : ( 1 / 6 ) DATE DATE 1 APPLICABLE TO : PROPOSAL PURCHASE AS BUILT
More informationROGERS MACHINERY COMPANY, INC
KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1
More informationIncrease Turbine Output. Gas Turbine Inlet Cooling
Increase Turbine Output Gas Turbine Inlet Cooling AMCO GAS TURBINE DIRECT SPRAY INLET COOLING AMCO provides extensive engineering, manufacturing, and application knowledge of Inlet direct spray cooling
More informationRIKT Isothermal Turbocompressors. With integrated cooling
RIKT Isothermal Turbocompressors With integrated cooling RIKT Isothermal Turbocompressors With integrated coolers MAN Diesel & Turbo s isothermal compressors have been built since 1915 and more than 1,400
More informationPaper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE
Paper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE Mercury 50 Field Evaluation and Product Introduction by David Teraji of Solar Turbines Incorporated San Diego, California, USA 1 AUTHORS
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More informationMSG TURBO-AIR 2000 Centrifugal Compressor
Benefits of MSG TURBO-AIR Compressors ISO 8573-1 CERTIFIED O I L- F R E E A I R E A S Y O P E R AT I O N Prevents oil contamination of your system The MAESTRO Universal control panel provides a built-in
More informationContact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)
Contact-Cooled Rotary Screw Air Compressors Nirvana 190-225 kw (250-300 hp) Ingersoll Rand is well into its second century of building our legacy as a trusted global leader by delivering the innovative
More informationThe Consortium of SKEC and GS E&C
n are the property of SK Engineering & Const. Co. Ltd (SKEC). They are merely loaned and shall not be disclosed to others or reproduced in any manner without written permission of SKEC. PROJECT NO. PROJECT
More informationANNEX A-5 GAS TURBINE JET ENGINE EXPANDER TURBINE STEAM TURBINE GENERATOR
ANNEX A-5 UNITS IN COMBINED CYCLE or CO-GENERATION BLOCKS INDEX TO SYSTEM/COMPONENT CAUSE CODES Inlet Air System and Compressors 5000-5039 Fuel, Ignition and Combustion Systems 5040-5079 Turbine 5080-5099
More informationSample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP
KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all
More informationSTANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 1250 ekw 1562 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
More informationJCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS
JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G2000QX G2000X Powered by MITSUBISHI ELECTRICAL PRIME STAND BY Output Rating kva 1892 2035 kw 1514 1628 Frequency Hz 50 Rated Speed RPM 1500 Standard Voltage
More information60 MW GE LM6000 PC Gas Turbine Power Plant
60 MW GE LM6000 PC Gas Turbine Power Plant The power plant consists of 50 MW GE LM6000 PC gas turbine, Year: 2011, 7000 hrs since new, 3000 rpm, 50 HZ, 13 MW Siemens SST 300 steam turbine with 5000 hours.
More informationQUANTUM PARALLEL SHAFT FAN DRIVE by Amarillo Gear Company
QUANTUM PARALLEL SHAFT FAN DRIVE by Amarillo Gear Company The patented Quantum Parallel Shaft Fan Drive for dry cooling systems reflects a long history of quality workmanship and reliability. Amarillo
More informationINDUSTRIAL GENERATOR SERVICE
INDUSTRIAL GENERATOR SERVICE PREVENTATIVE MAINTENANCE PROGRAM Customer: Date: Contact Person: Work Order #: Contact Number: ( ) Technician: INSPECTION COMPONENTS 1. GENERAL Check fuel tank level. Check
More information300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS
300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS series: Combining over 100 years of experience with innovative new technology makes the 21-L series the right choice for the demanding
More informationProducts & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)
630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup
More informationBHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2
BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR 1.00.00 GENERAL 1.01.00 Make : Jinan Power Equipment Factory 1.02.00 Type : WX21Z-073LLT 1.03.00 Reference Standard : GB/T7064-2002
More informationSynchronous Generators I. Spring 2013
Synchronous Generators I Spring 2013 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is then turned
More informationRoutine Compressor Maintenance
Establishing a regular, well-organized maintenance program and strictly following it is critical to maintaining the performance of a compressed air system. One person should be given the responsibility
More informationAnnex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL
Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL 1 TECHNICAL SPECIFICATION FOR 400V, 750 kva D.G. SET 1.0 SCOPE This specification covers the
More informationAll From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines
All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines 1 Introduction All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines ensuring maximum
More informationTECHNICAL OFFER. 1. CATERPILLAR PACKAGE OVERHAULED GENSET TYPE: C175-16, 2725KVA Prime Power, Build 2007, Original, Serial Number WYB00115, SMU 9725
TECHNICAL OFFER 1. CATERPILLAR PACKAGE OVERHAULED GENSET TYPE: C175-16, 2725KVA Prime Power, Build 2007, Original, Serial Number WYB00115, SMU 9725 1. Engine Technical Data: Maker: Caterpillar Inc. Type
More informationStandby Power Systems
Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to
More informationIntroducing the TM /
Introducing the TM2500+ 8 / What s New? LM2500 PLUS gas turbine Up to 30% more power! Two-trailer design 75% reduction in footprint Improved interconnection design Faster installation and set-up 9 / 31%
More information1x New Siemens SGT MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set
1x New Siemens SGT400 12.9 MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set 1. Scope of Supply Siemens Industrial Turbomachinery Ltd hereinafter Siemens offer to design,manufacture, package and despatch
More informationYR Steam Turbines PRODUCT
YR Steam Turbines PRODUCT Elliott YR Steam Turbines Elliott YR steam turbines are rugged and reliable pieces of precision turbomachinery. These masterpieces of Elliott engineering and craftsmanship serve
More informationBrief Introduction of The Selling Gen-set
Brief Introduction of The Selling Gen-set Ⅰ General Information The power plant started to operate on 29, Sep., 1997 and the stop operation date was 26, Jul., 2007 The gas turbine output is 37MW and steam
More informationProduct Data. Features/Benefits. MICROSTEAM 18MS Power System. Up to 275 kwe
Product Data MICROSTEAM 18MS Power System Up to 275 kwe The Microsteam 18MS power system offers: Energy generation from the steam that was previously wasted Peak shaving High efficiency operation Small
More informationFundamentals of Engineering High-Performance Actuator Systems. Kenneth W. Hummel
Fundamentals of Engineering High-Performance Actuator Systems Kenneth W. Hummel Author Name Chapter 1: Introduction...1 1.1 Fundamentals... 2 1.2 Performance... 2 1.3 Loads... 3 1.4 Constraints... 3 1.5
More informationGenerator and Motor Coolers
Generator and Motor Coolers Enerfin Generator and Motor Coolers (RAM) are manufactured and designed to ASME codes and TEMA standards as required. Our coolers with removable covers can be manufactured using
More informationLegal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:
Generating Facility Level 2 or 3 Interconnection Review (For Generating Facilities with Electric Nameplate Capacities no Larger than 20 MW) Instructions An Interconnection Customer who requests a Utah
More informationMYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent
The Myers heavy-duty series pumps are designed for residential raw sewage and light commercial applications. The non-clogging two-vane impeller delivers high-efficiency pumping and easily handles trashy
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please
More informationTurbine Trip Block. State of the Art Protection System APPLICATION SUMMARY INTRODUCTION TO FSD/IMI DESIGN AND
Turbine Trip Block State of the Art Protection System APPLICATION SUMMARY AND INTRODUCTION TO FSD/IMI DESIGN Turbine Speed Control and Safety System Turbine Tripping Principal Each Steam Turbine Has a
More informationSynchronous Generators I. EE 340 Spring 2011
Synchronous Generators I EE 340 Spring 2011 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is
More informationGlobal VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities
Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities YAMAZAKI Masaru NIIKURA Hitoshi TANIFUJI Satoshi ABSTRACT Fuji Electric
More informationHigh-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION
High-voltage motors series TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION series : Combining over 00 years experience with innovative new technology makes the series the right choice for the
More informationExpert Design...Trusted Power
Expert Design...Trusted Power 350 750 kva Range Performance I Durability I Serviceability A new power standard has arrived. The 350 750 kva range from FG Wilson is designed by our expert engineers to
More informationTechnical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System
Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System For SUITED COSTAL / EXPORT REFINERY PROJECTS 5-Km 450 NB (18 Dia.) Long Pipe Line
More informationROOTS Meters Series B3 Meter Models 8C175-56M175
ROOTS Meters Series B3 Meter Models 8C175-56M175 Refer to IOM-B3 for Complete Instructions IS:B3 3.03 RECEIVING, HANDLING AND STORAGE ROOTS rotary positive displacement gas meters are precision measurement
More informationT5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati
Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati 1 Introduction Ansaldo Energia has recently completed the manufacture, installation and commissioning of two synchronous condenser sets for
More informationAircraft Handling Ground Connections
Aircraft Handling Ground Connections Contents Ground Connections... 2 Electrical Power Connection... 3 Pneumatic Power Connection... 6 Conditioned Air Connection... 8 External Hydraulic Source Connection...
More informationNATURAL GAS CONTINUOUS
GAS GENERATOR SET NATURAL GAS CONTINUOUS 1950 ekw 2438 kva 50 Hz 1500 rpm Caterpillar is leading the power generation marketplace with power solutions engineered to deliver unmatched flexibility, expandability,
More informationPWH API 610 SINGLE STAGE OH2
PWH API 610 SINGLE STAGE OH2 PWH API 610 PROCESS PUMP HYDRAULIC PERFORMANCE COVERAGE 60 Hz Performance Coverage Visit our web site at www.pumpworks610.com and specify flow and performance needs and obtain
More informationKTA50 Land Based Drilling Power Modules
KTA50 Land Based Drilling Power Modules Description Cummins Land Based Drilling Power Modules are designed and tested based on oil field customer requirements to provide optimum performance, reliability,
More informationBombardier Challenger Auxiliary Power Unit
GENERAL A Honeywell 36 150(CL) constant-speed gas turbine auxiliary power unit (APU) is installed within a fire-resistant compartment in the aft equipment bay. The APU drives a generator, providing AC
More informationPressurized Air Cooled Generators
PGI Orlando Dec. 13, 2016 Pressurized Air Cooled Generators Mike Zborovsky New App Generator Portfolio Owner siemens.com Pressurized Air-Cooled Generator (SGenX-2000P) Table of content Introduction 3 Portfolio
More informationStandby 3000 kva 2400 ekw 50 Hz 1500 rpm 400 Volts
DIESEL GENERATOR SET Standby 3000 kva 2400 ekw 50 Hz 1500 rpm 400 Volts Image shown may not reflect actual package Caterpillar is leading the power generation market place with power solutions engineered
More informationSTANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts
DIESEL FEATURES GENERATOR SET STANDBY 2480 ekw 3100 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched
More informationAppendix B8 Combined Cycle Cogeneration Block Cause Codes
Appendix B8 Combined Cycle Cogeneration Block Cause Codes UNITS IN COMBINED CYCLE or COGENERATION BLOCKS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Gas Turbine Codes 300 399 or 700 799) (Steam Turbine Codes
More informationMSG TURBO-AIR 6000 Centrifugal Compressor
MSG TURBO-AIR 6000 Centrifugal Compressor 100% oil-free air* *Per ISO 8573-1 certification Your Trusted Partner in Compressed Air Ingersoll Rand works to keep you ahead of your competition with advanced
More informationOutdoor vacuum breaker for railway applications - FSK II
Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL
More informationEnVibe, Inc. Houston, Texas. Carbon Seal Rub on a Steam Turbine
Case History: Carbon Seal Rub on a Steam Turbine Joe McCollum EnVibe, Inc. Houston, Texas Summary This article describes the effects and vibration responses when carbon seal rubs are experienced on a steam
More informationPWH API 610 SINGLE STAGE OH2
API 6 SINGLE STAGE OH2 API 6 PROCESS PUMP HYDRAULIC PERFORMANCE COVERAGE Hz Performance Coverage Visit our web site at www.pumpworks6.com and specify flow and performance needs and obtain pump selection,
More informationGE Motors. PegasusTMMHV. Medium Voltage AC Induction Motors. NEMA Frames ,000 HP IEC Frames ,000 kw
GE Motors PegasusTMMHV Medium Voltage AC Induction Motors NEMA Frames 8200-8900 500-22,000 HP IEC Frames 400-1000 400-15,000 kw Experience Matters We ve manufactured motors for over 125 years. In 1879,
More informationRIKT 71 Isothermal Turbocompressor
RIKT 71 Isothermal Turbocompressor RIKT 71 Isothermal Turbocompressor MAN s RIKT isothermal turbocompressor family has a new member: the RIKT 71. In 2001, MAN introduced the RIKT to the market and many
More informationIPR M2i Tablet Press Pictures INDUSTRIAL PHARMACEUTICAL RESOURCES, INC PAGE 1 OF 3
IPR M2i Tablet Press Pictures M2i Tablet Press Rotary Feeder INDUSTRIAL PHARMACEUTICAL RESOURCES, INC PAGE 1 OF 3 IPR M2i Tablet Press Pictures Upper Pressure Roll with Punch Penetration Drive Motor &
More informationABB-TECHNICAL SPECIFICATION
Document Reference ABB-TECHNICAL SPECIFICATION CG-58C-04-C017-060003 Revision 3.0 Status AFC Document Type SPE System / Unit 60 Discipline ELE Rev. Date 21-11-2013 Contractor Reference 3N911-3BSY200001-GRN
More informationInstruction Manual for Single Stage 350, 500, and 700 Frame Steam Turbines
Instruction Manual for Single Stage 350, 500, and 700 Frame Steam Turbines Manual 107-A How to Use This Manual Dresser-Rand SST 350, SST 500, and SST 700 Single Stage Turbine Instruction Manual March 2011
More informationInstallation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100
Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP-53-030/055/100 Rev. 1 3/21/11 K.G. Type - John Wood #JWOP-53-030/055/100, Outdoor Glycol Feed System Capacity 30/55/100 Gallons
More informationCall us now: (+44) Fuel Polishing And Filtration Equipment. Page 1
Fuel Polishing And Filtration Equipment Page 1 Contents Fuel Polishing Systems... 3 Wall Mounted Fuel Polishers... 4 Particulate Filters... 5 Diesel Fuel Water Separators... 6 Page 2 Fuel Polishing Systems
More informationGauges, Sight Glasses and Vacuum Breakers
Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure
More informationCONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts
IE DIESEL FEATURES GENERATOR SET CONTINUOUS 800 ekw 1000 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver
More informationAGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.
STANDARD FEATURES GENERAL ENGINE Small Compact Design Powered by Perkins clean diesel engines Advanced Tough Series generator controller for manual or fully automatic operation Can be used full or part-time
More information60 Hz FEATURES. Exclusively from your Caterpillar dealer
L P & N A T U R A L G A S G E N E R A T O R S E T S STANDBY PRIME 60 Hz 100 kw 80 kw Model Standby kw (kva) Prime kw (kva) Natural Natural G100F3 100 (125) 85 (106.3) G90F3S 90 (90) 80 (80) G100F3S 100
More informationRating Definitions and Conditions
Model Frequency/Speed Voltage Prime Power Standby Power MP13 S MP15@6 S 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230V/400V 277V/480V 12.5 KVA 10 KW 13.5 KVA 10.8 KW 15 KVA 12 KW 13.75 KVA 11
More informationPRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts
DIESEL FEATURES GENERATOR SET PRIME 2260 ekw 2825 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched
More informationModel NA 2 L
Model MP1500@6 2 L Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230/400V 277/480V 1500 KVA 1200 KW 1500 KVA 1200 KW 1650 KVA 1320 KW 1650 KVA 1320
More informationNATURAL GAS CONTINUOUS 480 ekw 600 kva 495 ekw 619 kva 505 ekw 631 kva 510 ekw 637 kva 50 HZ 1500 RPM 400 VOLTS
GAS GENERATOR SET NATURAL GAS CONTINUOUS 480 ekw 600 kva 495 ekw 619 kva 505 ekw 631 kva 510 ekw 637 kva 50 HZ 1500 RPM 400 VOLTS Image shown may not reflect actual package Caterpillar is leading the power
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S
Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...
More informationGasoline Installation Instructions
Gasoline Installation Instructions Note: please read instructions completely before installation to ensure a safe/easy installation. Installation is broken down in 3-parts. 1. Pump/Tank/Nozzle - (mechanical)
More informationTM2500 & TM2500+ Mobile Gas Turbine Generator
TM2500 & TM2500+ Mobile Gas Turbine Generator December, 2008 Product Description 23-31 MW mobile gas turbine generator Easily transported by land, air, or sea 50 or 60 Hz flexibility Liquid or natural
More information