ASCO Low Voltage Automatic Transfer Switch Systems

Similar documents
Low Voltage Automatic Transfer Switch Systems

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Service Entrance Methods

SECTION MOTOR CONTROL

Bolted contact switches. Pringle switches

Florham Park, NJ USA Call (ASCO) for sales or service

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Optimizing Emergency Power Systems for Health Care Applications

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Operator s Series 300 Generator Paralleling System

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Solar Power Switchgear & Energy Storage Renewable Energy Systems

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

Operator s Manual Series ACTS Automatic Closed Transition Transfer Switches 150 through 4000 amps A. Rating Label.

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

Grounding Systems. Resistance. Resistance Grounding Systems Contents

SESL H - THREE PHASE AC VOLTAGE STABILISERS & REGULATORS. SESL H SERIES - THREE PHASE to 1500 kva. AC THREE PHASE TO 1500 kva

MP7650 CONTROLLER. Lake-Shore-Electric.com MP7650 Controller STANDARD FEATURES 1.0 INTRODUCTION

Bussmann series Quik-Spec Coordination Panelboard

Florham Park, NJ USA Call (ASCO) for sales or service

OTPC-SE Service entrance transfer switch open transition

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

POWERFUL LINEUP. Paralleling Generator Sets

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches, amps

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Operator s Manual Series ATS Automatic Transfer Switches 600 through 1200 amps

ASCO SERIES 185 Power Transfer Switches

Generator/Loadbank Quick Connection Tap Box

Fused Coordination Panelboard

A. Submit manufacturer's literature and technical data before starting work.

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Emergency Back-up Power Generation for Water & Wastewater Facilities

Paralleling Equipment

Quick Start Guide TS 910 & TS 920

Experience, innovation and reliability

Fused Coordination Panelboard

TS880 AUTOMATIC TRANSFER SWITCHES

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches 150 through 4000 amp. Rating Label. Nameplate A

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

www. ElectricalPartManuals. com Operator s Manual

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

SECTION PANELBOARDS

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

SIGNAL WORDS QUALIFIED PERSON

CHPC Transfer switch closed transition

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DG SYNCHRONIZING &AMF PANEL

PARALLELING SWITCHGEAR

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Quik-Spec. Section Contents

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

Transfer switch OTEC and OTECSE open transition

University of Houston Master Construction Specifications Insert Project Name

Specialty Service Entrance Switchboards. Selection and Application Guide

Caterpillar 1500kW XQ1500

Quick Start Guide TS 910

Quik-Spec Electrical Gear

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Transfer switch OHPC open or delayed transition

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

OTEC Transfer switch open transition

Installation Manual. E-design A Transfer Switches A

3ATS & 3NTS J-design 600 A 3ADTS & 3NDTS A Transfer Switches. Installation Manual. Installation A DANGER. Table of Contents WARNING

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Now - Up To 400A Mains!

Critical Power Switchboards. Selection and Application Guide

Rental Power QSL9 series engine

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

OHPC/CHPC Transfer Switches

WARREN COUNTY, N.Y. M/E REFERENCE

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

SECTION DISTRIBUTION AND GROUNDING

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Accessory 44 Strip Heater. Automatic Transfer Switches. Wiring. Mounting H

Power System Solutions (PSS)

Backup Generation Application

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Busway Construction. Bus Bars

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Cutler Hammer 200 Amp Generator Manual Transfer Switch Nema 3r

Bypass Isolation Transfer Switches Amperes

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Transcription:

ASCO Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications ASCO s experience and commitment to excellence in designing and building Emergency Power Control Systems for any application has made us the premier manufacturing and service organization in the world. For over 100 years we have built upon a tradition of providing our customers a full range of high performance and quality products. ASCO s experience spans the history of the power control industry and since 1888 we have set the standard for the entire industry. Our reputation as the leader in emergency power control equipment speaks to the quality of our products and the dedication of our people. ASCO operates two modern facilities dedicated to manufacturing low and medium voltage power control systems. Located in Welcome, North Carolina and Stockton, California, these manufacturing plants produce state-of-the-art power control systems for emergency or standby power generation, peak load shaving, prime power, parallel with utility, cogeneration, emergency load management and power distribution. These products are designed and manufactured to meet and exceed the demands of a growing global market. Our ongoing dedication to research & development and extensive testing have confirmed ASCO products as the industry standard. Since our beginnings this same dedication has established ASCO as the pioneering innovator in the emergency power control industry. This commitment continues to set ASCO apart as the company that stands at the threshold of new technologies and has resulted in a long list of industry firsts throughout the years. ASCO has always been committed to providing a full range of products with only one thing in mind... transferring power from an available source to a critical load. Telecommunications systems, data networks, industrial processes and critical installations demand proven emergency and standby power transfer solutions. As the worlds leader in emergency and standby power, ASCO products and systems safeguard your business... because we keep your power on.

Service Entrance Rated Transfer System ASCO service entrance rated transfer systems are designed for automatic switching of loads between the utility source and an alternate source of power. The transfer system also contains a disconnect device on the normal source, plus a disconnect link on the utility neutral, and a disconnect link between neutral and ground. If the utility source is Y connected, the voltage is greater than 250 volts phase to neutral and the system continuous current is greater than 1000 amperes, the utility disconnect device will be equipped with ground fault trip. Figure 3 shows a typical service entrance rated transfer system with a 1200 ampere automatic transfer switch and a 1200 ampere utility circuit breaker. The utility disconnect device will be equipped with ground fault trip if the voltage between neutral and ground is greater than 250 volts, and the continuous current is greater than 1000 amperes. Disconnect link for the utility neutral bus. Disconnect link between the neutral bus and the ground bus. Meets all NEC requirements for service entrance rating, and is labeled to UL 891 standards. Available up through 4000 amperes using ASCO 940, 962, 434, 436 and ASCO's 7000 SERIES automatic transfer switches. Fig. 3 Service entrance rated transfer system. Fig. 4 One line diagram of the service entrance rated transfer system shown in figure 3.

ATS Switchboards An automatic transfer switchboard is a switchboard containing two or more automatic transfer switches in a common line-up. The switchboard shown in figure 5 contains two ASCO 962, 2000 ampere, automatic transfer bypass-isolation switches with circuit breakers on the normal and load side of each switch. An ammeter and voltmeter are also located on the load side of each switch. Connects multiple automatic transfer switches together in a common switchboard. Optional normal and/or emergency circuit breakers for overcurrent protection. Optional distribution circuit breakers of the size and type to meet customer load requirements. Optional instrument meters for normal, emergency, or load for local monitoring. Designs can be provided with a UL 891 Label containing up through a 10,000 ampere main bus. Utilizes ASCO 940, 962, 434, 436 and ASCO's 7000 SERIES automatic transfer switches. Fig. 5 Automatic transfer switchboard. Fig. 6 One line diagram of the automatic transfer switchboard shown in figure 5.

Two Source Automatic Transfer System ASCO two-source systems are designed for automatic switching of loads between the utility source and an alternate source of power. Upon the loss of the utility power source, the system provides an automatic start signal to the alternate source of power. Once the alternate source has reached proper voltage and frequency, the system transfers the critical load from the utility source to the alternate power source. When normal power is restored the controls will retransfer the load to the utility and signal shutdown of the alternate power source after allowing a cooldown period. ASCO two-source systems include an automatic transfer switch, plus any or all of the following options; automatic engine starting controls, overcurrent protection for both emergency and normal sources, instrument meters, status annunciation, and audible alarm. The systems are designed to NEMA switchboard construction and are labeled to UL 891 standards. These systems can be designed for top cable entrance, bottom cable entrance or bus duct connections. The system shown in figure 7 contains a 1200 ampere closed transition automatic transfer switch with a 1200 ampere utility circuit breaker, multi-purpose meter, reverse power relay, and an alarm horn. Fig. 7 Two source system with main circuit breaker, protective relaying and and automatic transfer switch rated 1200 amperes. Normal, emergency, and/or load circuit breakers. Protective relaying (as required). Optional instrument meters for normal, emergency, or load for local monitoring. Designs are based on NEMA and UL 891 standards. Optional engine start control logic and/or load control logic. Designs available up to 4000 amperes utilizing ASCO 940, 962, 434, 436 and ASCO's 7000 SERIES automatic transfer switches. Fig. 8 One line diagram of the two source automatic transfer system shown in figure 7.

Three Source Automatic Transfer System ASCO three-source systems are similar to ASCO twosource systems except that a second alternate power source is added to back up the first if that power source fails. Upon the loss of the utility power source, the system provides all necessary controls to start both alternate power sources. The critical loads are automatically transferred to the first alternate power source that achieves acceptable voltage and frequency. The second alternate power source is then automatically shutdown after a time delay and cooldown period. If the first alternate power source fails, the second alternative power source will be automatically re-started and the load will be transferred from the first alternative power source to the second alternative power source. When the normal power is restored, the controls automatically retransfer the load to the utility power source. Fig. 9 Three source automatic transfer system. Control logic for selecting between the alternative power sources. Normal, emergency, and/or load circuit breakers. Protective relaying (as required). Optional instrument meters for normal, emergency, or load for local monitoring. Designs are based on NEMA and UL 891 standards. Optional engine start control logic and/or load control logic. Designs available up to 4000 amperes utilizing ASCO 940, 962, 434, 436 and ASCO's 7000 SERIES automatic transfer switches. Fig. 10 One line diagram of the three source automatic transfer system shown in figure 9.

Three Source Priority System Fig. 11 Three source priority system. ASCO three-source priority systems are similar to the ASCO three-source systems except they protect two critical loads rather than one critical load. Upon the loss of the utility power source, the system provides all necessary controls to start both alternative power sources. The most critical load is transferred to the first alternate power source that achieves acceptable voltage and frequency. Priority selector transfer switch. Control logic for selecting between alternate power sources. Normal, emergency, and/or load circuit breakers. Protective relaying (as required). Optional instrument meters for normal, emergency, or load for local monitoring. Designs are based on NEMA and UL 891 standards. Optional engine start control logic and/or load control logic. Designs available up through 4000 amperes utilizing ASCO 940, 962, 434, 436 and ASCO's 7000 SERIES automatic transfer switches. The second most critical load is then transferred to the second alternate power source when it achieves acceptable voltage and frequency. If the alternate power source feeding the most critical load should fail, the most critical load would be transferred to the second alternate power source and the second most critical load would be shed. When the utility power source is restored, the system controls automatically retransfer the loads to the utility and both alternate power sources are run for a cooldown period and then shutdown. Fig. 12 One line diagram of the three source priority system shown in figure 11.

Soft Load Transfer System ASCO soft load closed transition transfer switches provide a make-beforebreak transfer of a building load from a utility power source to an alternate power source. This system automatically brings the engine generator intosynchronism with the utility source, then gradually shifts the load from the utility to the engine generator with virtually no voltage or frequency fluctuations. Open or closed transition transfer between normal and emergency. Emergency or peak shave mode of operation. Engine start control logic and load control logic. OAvailable configurations include either an ASCO 434, 436 or ASCO s new 7000 SERIES closed transition transfer switches through 4000 amperes. The transfer system configuration can also accommodate power circuit breakers. Normal and emergency circuit breakers can be provided when using a transfer switch for overcurrent protection. Protective relaying (as required). Optional instrument meters for normal, emergency, or load for local monitoring. Designs are based on NEMA and UL 891 standards. Fig. 13 Soft load transfer system. Fig. 14 One line diagram of the soft load transfer system shown in figure 13.

Custom Applications Fig. 15 Selective load system. Selective Load Systems Selective load systems allow one load at a time to be operated when normal power fails. The system uses the minimum amount of auxiliary power for operation so the alternate power source can be sized for only one load at a time. The selective load system can be designed to handle any number of loads in any combination of sizes to suit the customers needs. The only interfacing between the ASCO selective load system and the load controls are power cables. The system can be used with any electrical load application where only one load out of a number of loads are to be operated from the alternate power source at one time. A typical application is with multiple banks of elevators when you want to enable only one elevator at a time to operate under emergency conditions. The system can be supplied with a separate control panel, which allows loads to be selected from a remote location. Figure 15 shows a typical selective load system with transfer switches for five loads. The control panel has a selector switch and position indication of each load. Transfer Switch with Distribution System Transfer switches can be provided with normal and emergency circuit breakers for overcurrent protection, plus any combination of distribution circuit breakers, bolted pressure switches, or fusible disconnect switches. Figure 16 shows a switchboard containing a circuit breaker on the normal source of the automatic transfer switch plus a distribution panelboard of molded case circuit breakers to protect critical downstream loads. The cubicle on the left end of the system provides monitoring and control of the distribution system. Fig. 16 Transfer switch with distribution.

Custom Applications Transfer Switch with Bottom Bus Risers Figure 17 shows a 4000 ampere transfer switch with bus risers for bottom entry bus duct on both the normal source and load connections. The emergency side of the transfer switch has lugs for cable connections from the top of the enclosure. This demonstrates our capability to meet custom service entry requirements. Fig. 17 Transfer switch with bottom bus riser. Transfer Switch in an Outdoor Enclosure Figure 18 shows a transfer switch with a fuse disconnect switch on the normal side. The switch is in a non-walk-in NEMA 3R outdoor enclosure. The outdoor enclosure is designed for front and rear entry only with three point catches on the doors as well as provisions for padlocking. Fig. 18 Transfer switch in an outdoor enclosure.

ASCO Power Technologies - Global Headquarters 50 Hanover Road Florham Park, NJ 07932 Tel: 800 800 ASCO customercare@asco.com www.ascopower.com www.ascoapu.com ASCO. Innovative Solutions., ASCO Power Technologies and the ASCO logo are trademarks and service marks of ASCO Power Technologies 2016 ASCO Power Technologies. All rights reserved. 1998. Publication 3049 ASCO. Innovative Solutions.