1U 4 Bay Chassis Rack Mounting Instructions

Similar documents
Raidtec 20-Inch Rack Mount Guide Version 1.0

Installing the ONS M6 Shelf

HP Server Mount Kit AB292A for 19 in. 2-Post Rack Installation Instructions Manufacturing Part Number: AB April 2004

Raidtec Rack Mount Guide Version 2.1

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Installing the Switch Chassis

ARION: 19 EIA-310E Standard Enclosure

Installing the Switch

Hardware Install Guide

High Frequency SineWave Guardian TM

Installation Instructions : Audi C7 RS6 Intake System : Page 1

HP Modular Cooling System 200/100 Options Installation Guide

Mobtown Offroad Toyota Tacoma Bolt On Rock Slider Installation Instructions

2-Post Rack Mount Kit Installation Instructions

Rack Installation Guide (Steelhead Series 3000, 5000, and 6000, and Interceptor Systems)

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Switch Installation. Preparing for Installation. Warnings CHAPTER

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Installation and Service Manual

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Set Up. We recommend that you read through this entire set of instructions prior to removing your 231 Transfer case from the Jeep

CERTIFIED MODULAR HEAT SHIELD SYSTEM EXTENSION AC02713 INSTALLATION INSTRUCTIONS

Syntron EB-00 Vibratory Parts Feeder GENERAL MANUAL

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

Getting Started With Your System

36 HYPER MAX DIRECT DRIVE GALVANIZED BOX FAN

Mass Exports- 2/368 B, Irugur Road, Chinniampalayam, Coimbatore , Tamil Nadu, India

MECHANICAL INSTALLATION PROCEDURES for Custom Grids and Support Framing

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

AA TRUCK TALK EQUIPMENT FOR THE 88-A PLATFORM

Installation and Operations Manual

Part No Part No Product Name: Adventure System

CHASSIS TECH TIPS. Subject: DPR TEMPERATURE SENSOR CIRCUIT LOAD TEST

Performance Brake Caliper Guide Bushing Set Installation Guide

Build your own THUNDERBIRD 2

SAFETY. Your safety and the safety of others is very important.

Wheel Angle Sensor Kit Installation

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

42U Server Rack Cabinet - 37 in. Deep Enclosure

Owner s Manual. PowerVerterDC-to-AC Inverter

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Shipping and Receiving

HitchHoist Assembly & Operating Instructions IMPORTANT NOTICE

HD BULL NOSE FRONT BUMPER FORD SUPERDUTY F PARTS LIST:

Preparing for Installation

Wall-Mount Server Rack with Built-in Shelf - Solid Steel - 8U

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

The following information shows the steps to change the rear brake pads and rotors on an E36 chassis.

How to Change Front Brake Pads on a Toyota Corolla

Server Rack Cabinet - 31 in. Deep Enclosure - 12U

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

PARTS LIST: ELEVATION BULL NOSE FRONT BUMPER FORD SUPERDUTY F

Performance Air Intake, 2015+

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

ALLDATA Online Jaguar Vanden Plas L6-3980cc 4.0L DOHC - Service and Rep...

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Installation Instructions

SAFETY. Read and understand all safety precautions and instructions before installing this product.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Super Duty Front Air Bag Installation Instructions

2015 Ford F150 Rear Bumper w/ LED

Demarcation Fuse Alarm Panel

42U Server Rack Cabinet - 30 in. Extra Wide - 37 in. Deep Enclosure

DL650 Odyssey Luggage Installation Guide

Passenger/Right Support Bracket Driver/Left Support Bracket

IBM UPS Extend Run Battery Pack Operation and Setup Guide

TO AVOID DOING IRREPARABLE DAMAGE TO DRIVE CIRCUITRY NEVER APPLY AC POWER DIRECTLY TO LED LIGHTBOXES!

Cisco ASR 1002 Router Overview and Installation

Switching DC Power Supply

Before starting installation

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

NetShelter AR1000 AR1001 AR1100

James Barone Racing Aftermarket Parts and Accessories

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

License Plate Bracket (4) Rubber Plugs. (2) Retaining Rings (2) Foam Spacers

Preparing the Site. Information About the Site Requirements CHAPTER

T15 Fleet Frontal Protection System Vehicle: Mazda BT50 09/08+ Part No. 070SB15X46Z

Basic Vehicle Stabilization

Fully assembled, ready-to-use custom cabinets.

CorkSport Adjustable Front Swaybar ND MX-5

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

ComfortPoint Programmable Lon, VAV/Unitary Controllers

5713 / 5714 JK HEAVY DUTY GAS TANK SKID PLATE Version 1.1

Control Box Wiring For PRSstandard Tool

ECO-SERIES REAR BUMPER FORD F150 PART # FD-2962

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

04-08 FORD F150 4 KIT

STARTER SYSTEM TESTING 5.6

SAFETY. Injury hazard

INSTALLATION INSTRUCTIONS HEAVY DUTY FRONT BUMPER CHEVY SILVERADO 1500

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

JEEP JK MANUAL SHIFT 1 1/4 2 / 4 DOOR BODY LIFT

ES Series Enclosures Installation Instructions (UL /UL2416 ES Series Equipment Cabinet/Rack)

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Fluid Coil Installation, Operation and Maintenance

IGLOO IGLOO EASY INSTRUCTION MANUAL

Transcription:

The instructions in this article apply to the rack mountable 1U 4 Bay Barracuda SC813 chassis which is no longer distributed. For newer chassis, refer to 1U Chassis Rack (Four Screw) Mounting Instructions or 1U Chassis Rack (Two Screw) Mounting Instructions. This article refers to rack mountable 1U 4 Bay Barracuda SC813 chassis with provided rails; for a complete list of appliances by model, see Rack Installation of Barracuda Appliances. Rack assembly differs depending on the model of rack unit in your environment. Before rack mounting the appliance, review the installation instructions that accompany your rack unit for detailed rack setup instructions. Before Getting Started Verify that you have the cage nuts and screws to attach the appliance to your rack; these are not provided by Barracuda; Verify that you have the rail kit included with your appliance, including the hardware to assemble the rails; Verify the rack unit is set up in a Restricted Access Location, for example, dedicated equipment rooms, service closets, and other secure, clean, dust-free well ventilated environments; Allow enough clearance in front of the rack to allow the front door to open completely (~25 inches); Verify approximately 30 inches of clearance is available in the back of the rack to allow for sufficient airflow and ease of servicing; Verify the area does not generate heat, electrical noise, or electromagnetic fields; A grounded power outlet is available. Ensure the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. In a single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together. Verify the rack is stable before extending a component from the rack. Extend only one component at a time; extending two or more simultaneously may cause the rack to become unstable. Review the electrical and general safety precautions that came with the components you are adding to the chassis. Determine the placement of each component in the rack before you install the rails. Install the heaviest appliance components on the bottom of the rack first, and then work upwards. Use a regulating uninterruptible power supply (UPS) to protect the appliance from power surges, voltage spikes, and to keep your system operating in case of a power failure. Allow the hot plug hard drives and power supply modules to cool before touching them. Always keep the rack's front door and all panels and components on the appliances closed when not servicing to maintain proper cooling. Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (Tmra). Proper Airflow and Mechanical Loading Mount equipment into a rack so that the amount of airflow required for safe operation is not compromised and to prevent any hazardous condition that 1 / 9

can arise due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing these concerns. Reliable Ground To ensure a reliable ground at all times, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). Inspect the Packaging Before getting started, inspect the shipping box and note if there is any damage. If the chassis itself shows any damage, file a damage claim with the carrier who delivered your Barracuda appliance. Install the Appliance in the Rack Refer to the installation instructions that came with the rack unit you are using for detailed instructions; these rails fit a rack between 26" and 33.5" deep. Install Inner and Outer Slides Use the following steps to install the inner slides, as shown in Figure 1. 1. Locate the right inner slide, the slide that will be attached to the right side of the chassis when facing the front panel of the chassis, and align the four square holes on the right inner slide against the hook on the right side of the chassis slide the long bracket into the short bracket (1). 2. Securely attach the slide to the chassis with two M4 flat head screws (2). 3. Repeat steps 1 and 2 to install the left inner slide to the left side of the chassis. 4. Measure the distance from the front rack rail to the rear rail of the rack. 5. Attach a short bracket to the rear side of the right outer slide, and a long bracket to the front side of the right outer slide (3). 6. Adjust the short and long brackets to the proper distance so that the chassis will fit snugly into the rack (4). 7. Secure the slides to the rack with the provided screws. 8. Repeat steps 4 through 7 for the left outer slide. Figure 1. Install Inner and Outer Rack Rail Sections. 2 / 9

Install Slide Assemblies Secure the slide assemblies to the rack using four M5 screws and washers (1), as shown in Figure 2: Figure 2. Install Slide Assemblies. 3 / 9

Install Chassis into the Rack Use the following steps to install the chassis into the rack. 1. Push the inner slides, which are attached to the chassis, into the grooves of the outer slide assemblies (1), as shown in Figure 3. Figure 3. Install the Chassis into the Rack. 4 / 9

2. Push the chassis into the outer slide assemblies (2), as shown in Figure 4: Figure 4. Insert Chassis into Rack. 5 / 9

3. Push the chassis all the way to the back of the outer slide assemblies (3), as shown in Figure 5: Figure 5. Push the Chassis to the Back of the Outer Slide Assemblies. 6 / 9

For detailed configuration steps, refer to the Getting Started section for the rack mounted appliance. Remove the chassis from the rack In Figure 6 below, the locking clips on the rails are circled. In Figure 7, see the locking clips on the two far left rails. These clips must be released when removing the server. Figure 6. Locking clips. 7 / 9

Figure 7. Black locking clips shown on rails on left of photo. 8 / 9

Figures 9 / 9