Validation Test Report

Similar documents
NATIONAL TECHNICAL SYSTEMS

Reliability & Qualification Report for MEMS Based Variable Optical Attenuators

QUALIFICATION TEST SUMMARY REPORT ESR Qualification Type Testing of Amphenol Corporation s 2M801 Series Connector

JUNE 11, 2010 TEST REPORT # S2SD CABLE ASSEMBLY QUALIFICATION TESTING PART: T2SD L D-NDS MATING PART: S2M L-D-LC SAMTEC, INC.

APRIL 19, 2010 TEST REPORT # S2SD CABLE ASSEMBLY QUALIFICATION TESTING PART: S2SD S D-NUS MATING PART: T2M L-D-TH

Application Note 5283

ADVANCED MAGNETICS FOR MOTION CONTROL HIGH PERFORMANCE ROTARY & LINEAR COMPONENTS

Electromechanical Rotary Actuator

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

PRODUCT SPECIFICATION

Product Specification QSL RF Connectors

MILITARY SPECIFICATION SHEET

IQLab Pack UNDOT Test Report

PRODUCT SPECIFICATION

QSFP Copper Module Direct Attach Cable Assembly &Cage

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

NATIONAL TECHNICAL SYSTEMS

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

Shock and Vibration Test report. Shock and Vibration Summary Test Report

MEZALOK* Stacking Connector System

Model ½ Digit Multimeter

Jun 20,2014 Rev A

GETWELL TECH.(H.K.) LTD.

Quantum Series Size 17, 23, 34 and 56 Brushless Servo Motors Frameless and Housed Engineering Guide

Maintenance Capability List

DETAIL SPECIFICATION SHEET

Features & Benefits. Options & Accessories

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

Constant Voltage/Constant Current Test System

Question Bank ( ODD)

Aug07 Rev A All Paragraphs Revised

VISIT US ON OUR

SAMTEC POWER CHARACTERIZATION

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

ABI Cooler System Protoflight Performance

3M CP2 Press-Fit Headers and Sockets, 2 mm

Metal Alloy Low-Resistance Resistor Specifications

Sample Lab Test Report. Requested By INDIA

600 Amp Surge Arrester

Modification Record of Product Specification

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SAMTEC POWER CHARACTERIZATION

VIA Platform Environmental Qualification Testing Standards

SHOCK TESTING OF EQUIPMENT AND SYSTEMS NAVAL APPLICATIONS

Bulletin 871P Can Sensors

COMPLIANCE TESTING FOR FMVSS 207 SEATING SYSTEMS

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY MAMALLAPURAM, CHENNAI

Jun06 Rev D

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

Instruction of connection and programming of the VECTOR controller

Features & Benefits. Options & Accessories

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

Test Group Description. Total Number. Figure 1. Unless otherwise stated, the following environmental conditions prevailed during testing:

Encoder Installation Manual Dynapar brand SERIES M21 Modular Encoder

GIMBALLING MAGNETIC BEARING REACTION WHEEL WITH DIGITAL CONTROLLER

SPECIFICATION 宏致電子股份有限公司 桃園縣中壢市東園路 13 號. No.13, Dongyuan Rd., Jhongli City, Taoyuan County 320, Taiwan (R.O.C.)

R&D Lab: BRUSHLESS MOTOR BRUSHLESS MOTOR. Line card common characteristics: High Speed-Torque BLDC Industrial Motors

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

Low Profile Connectors for AC power supply

Fluke 438-II Power Quality and Motor Analyzer

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Hydrogen Station Equipment Performance Device (HyStEP Device) Specification

Serial Attached SCSI (SAS) Connector

ULTRASONIC EXAMINATION

CERTIFICATE OF ACCREDITATION

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV

PRODUCT SPECIFICATION

PERFORMANCE SPECIFICATION SHEET

SEP 2016 Rev D2

Summary of HALT, IPx7 & IP69K testing for AT Series connectors

Brushless Servo Motors

University of New South Wales School of Electrical Engineering & Telecommunications ELEC ELECTRIC DRIVE SYSTEMS.

LOW SHOCK RELEASE UNIT EASY RESETTABLE AND 100 % REUSABLE. Jens Müller 1, Christoph Zauner 2

Product Specification AMP Mini CT DC Drawer Connector, 1.5 mm Pitch Lead Free Version

SPECIFICATION SHEET P700L CURRENT LIMITING FUSE SURFACE MOUNT MODEL

Cold Resistance (Ohm) Note 1

Table 2: Ratings Symbol Parameter Test Conditions Min. Typ. Max. Unit Source Document

ENTERY INDUSTRIAL CO., LTD. E&T ELECTRONICS (DONG GUAN) CO., LTD. E&T ELECTRONICS (SU ZHOU) CO., LTD.

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

Freescale Semiconductor, I

Brushless Torque Motors

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, MOMENTARY, 4 CIRCUIT OR DPDT (10 AMPERES), UNSEALED

PENTAGON PROTECTION USA

K50F003UP cam changeover switch - 3-pole A - screw mounting

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

K63F003UP cam changeover switch - 3-pole A - screw mounting

JANUARY 22, 2008 TEST REPORT #207512A/ MPX-VT TEST PLAN CONNECTOR TESTING CONNECTOR SERIES MPSC/ MPTC MPS/MPT SAMTEC, INC.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

KWA. Evaluation of the Vaporless Manufacturing LD 3000 and LD 3000S Mechanical Line Leak Detector on Large Rigid and Flexible Pipelines.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Apr11 Rev A

AP/UP, AP/MIL Series Magnetic Circuit Protectors

K50H004UP cam changeover switch - 4-pole A - screw mounting

Steady-State Engine Modeling for Calibration: A Productivity and Quality Study

Transcription:

1499 Poinsettia Ave., Suite 160 Vista, CA 92081 Validation Test Report High Pressure High Temperature (HPHT) Brushless DC (BLDC) Motor DII15-60-201A Rev Date Author Reviewed App. by Comments by A 2/1/17 J.Eral H.Minor A.Galvan 1 st release B 2/14/17 J.Eral H.Minor A.Galvan Addition of environmental test conditions to 5.3 section. Scope re-defined. Page - 1 - of 12

1. Introduction...- 3-2. Purpose...- 3-3. Results...- 3-4. Test Description...- 3-5. Test Program...- 3-5.1. Bench Test...- 3-5.1.1. Resistance Measurement...- 3-5.1.2. Inductance Measurement... - 4-5.1.3. BEMF Measurement...- 4-5.1.4. Insulation Resistance Test...- 5-5.1.5. Functional Test...- 5-5.2. Mechanical Durability Test...- 6-5.2.1. Vibration Test... - 6-5.2.2. Shock Test...- 6-5.3. Environmental Durability Test...- 7-6. Test Certification & Data...- 10-6.1. Bench Test...- 10-6.1.1. Bench Test Certification...- 10-6.1.2. Bench Test Equipment List...- 10-6.2. Mechanical Durability Test...- 11-6.2.1. Mechanical Durability Test Certification...- 11-6.3. Environmental Durability Test...- 11-6.3.1. Environmental Durability Test Certification...- 11-6.3.2. Environmental Durability Test Equipment List...- 12-7. Qualification Test Matrix...- 12 - Page - 2 - of 12

1. Introduction This report summarizes the validation test procedure (ATP0163) and results for the BEI Kimco enhanced DII15-60-201A High Temperature High Pressure Hall Commutated BLDC designs. 2. Purpose The purpose of the validation test protocol was to validate the BEI Kimco enhanced DII15-60- 201A design under the specified temperature, pressure, vibration and shock conditions. The approved design will be released as P/N DII15-60-201A. 3. Results Initial Standard Performance Acceptance Test (10 units) All units passed Initial Bench performance tests. Environmental Durability Test All units passed Environmental Durability performance tests. Mechanical Durability Test All units passed Mechanical Durability test. Final Standard Performance Acceptance Test All units passed Final Bench performance tests. The HPHT motor has been validated to withstand all environmental conditions outlined in this test report and is therefore released for sale. 4. Test Description The validation test protocol was conducted between 08/09/14 and 1/11/17. Ten (10) test units of BEI Kimco DII15-60-201A were used for the validation test program. Section 5 of this report describes the test procedure followed in this evaluation program. Section 6 describes the test data for each test sequence. 5. Test program 5.1. Standard Acceptance Test This test applies for Initial, Intermediary and Final Bench Test. Its purpose is to validate the motors before and after the other tests; Mechanical Durability and Environmental Durability. 5.1.1. Resistance Measurement Resistance was measured with a Model 2750 Multimeter/Switch System and then results were recorded. Page - 3 - of 12

Figure 5.1.1 5.1.2. Inductance Measurement Inductance was measured with a four-terminal sensing device @ 1000Hz and results were recorded on result summary form. Figure 5.1.2 5.1.3. Back Electro Motive Force (BEMF) Constant Measurement/Calculation Motor was back driven @ 1800 rpm by externally coupled AC motor. The measurement was performed using an oscilloscope. The proper phase sequencing was verified. BEMF value data was recorded and BEMF constant calculated. Page - 4 - of 12

Figure 5.1.3 5.1.4. Insulation Resistance Test Pass/fail test data was recorded. Figure 5.1.4 5.1.5. Functional Test The device under test was driven open loop. The motor should rotate properly in both directions. Speed and no load current data were recorded. Page - 5 - of 12

Figure 5.1.5 5.2. Mechanical Durability Test 5.2.1. Vibration Test 10 motors were tested to meet a reliability of 90% and a confidence of 50%. Frequency Range 30-500Hz Amplitude 25 g rms Number of Axes 3 Duration 3h/ Axis Total Duration 9h Axis 1 Axis 2 Axis 3 5.2.2. Shock Test 10 motors were tested to meet a reliability of 90% and a confidence of 50%. Pulse Amplitude 1000g (~9810m/s²) Pulse Duration 0.5 ms Number of Axes 3 Number of Pulses/Axis 2 Total Pulses 6 Page - 6 - of 12

Axis 1 Axis 2 Axis 3 5.3. Environmental Durability Test 10 motors were tested to meet a reliability of 90% and a confidence of 50%. Pressure 30,000 psi Temperature 205 C Total Duration 600h min Motors assembled into their fixtures. Two thermocouples were installed at the top of each couple of motors. Fixture mechanically connected to the plug. Page - 7 - of 12

The fixture and plug were placed inside the vessel prefilled with oil. The connections to the controllers were then made. Fixture was then sealed. Page - 8 - of 12

Pressure was raised up to 10,000psi and temperature was raised to 205 C. Raising the temperature increased the pressure up to 25,000 psi. The pressure was then adjusted to 30,000 psi. Motors were powered during 100% of the life test duration, 660 hours restarting every 24 hours. A blinking LED indicated normal activity per motor. Activity was verified once per day. The fixture was able to operate a maximum of 4 motors simultaneously. The test was divided in two groups (8 motors total) Page - 9 - of 12

6. Test Certification & Data 6.1. Standard Acceptance Bench Test 6.1.1. Bench Test Certification Test Procedure No: ATP0142 No. of units tested: 10 Units Test start date: 08/09/14 Test finish date: 08/09/14 Test operator: Dom Deguia Remarks: All units passed initial bench performance tests. 6.1.2. Bench Test Equipment List Test Name: 5.1 Bench Test Procedure: Operator: ATP0142 Dom Deguia Manufacturer Model# Description Asset# Last CAL Next CAL Keithley 2750 Resistance 23207-07 02/19/14 02/05/15 Meter QuadTech 1715LCR Inductance 23207-08 02/19/14 02/05/15 Meter Hipotronics HM3A Insulation 23207-09 02/19/14 02/05/15 Resistance Tektronix TDS3054B Oscilloscope 23213-10 02/20/14 02/05/15 BEI Kimco TFM0088 Controller 22620-24 NA NA Page - 10 - of 12

6.2. Mechanical Durability Test 6.2.1. Mechanical Durability Test Certification Test Procedure No: N/A, non-proprietary No. of units tested: 10 Units Test start date: 01/28/16 Test finish date: 01/29/16 Test operator: Elite Test Remarks: All units passed mechanical durability tests. 6.2.1.1. Vibration Test See 1600962-01 Vibration Test 6.2.1.2. Shock Test See 1600962-01 Shock Test 6.3. Environmental Durability Test 6.3.1. Environmental Durability Test Certification Test Procedure No: N/A, non-proprietary No. of units tested: 10 Units Test start date: 10/15/16 Test finish date: 11/17/16 Test operator: PHT Remarks: All units passed environmental durability tests. Page - 11 - of 12

6.3.2. Environmental Durability Test Equipment List Manufacturer Model# Description Asset# Last CAL Next CAL Astragauge ASTR6 Pressure gauge NA 03/20/15 03/20/16 Omega 5TC-TT-K- 30-36 Thermocouple NA NA NA FLUKE 189 DMM 07/17/15 07/17/16 Ingenia PLUTO- STD Controller NA NA NA HIP NA Pressure Vessel NA NA NA 7. Qualification Test Matrix Environmental Durability Test (10 Hall Sensor Assy) (Sect. 5.3) Initial Test Bench (10 units) (Sect. 5.1) Vibration Test #3 (10 units) (Sect. 5.2.1) Shock Test #3 (10 units) (Sect. 5.2.2) Final Test Bench (Sect.5.1) Page - 12 - of 12