Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Similar documents
T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Solenoid Valve Island Type 3965

Type Electronic Limit Switch

Limit Switch Type 3776

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

Solenoid Valves Type 3963

Type 3967 Solenoid Valve

Series 3730 Electropneumatic Positioner Type

Competence in Functional Safety MANUAL. principle and typical applications

Type 4746 Electric or Pneumatic Limit Switch

Solenoid Valve Type 3962

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Electronic Limit Switch Type

Limit Switch Type 4747

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Series 3730 Type Electropneumatic Positioner. Fig. 1 Type Mounting and Operating Instructions EB EN ( )

Limit Switch Type 3776

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

EB EN. Translation of original instructions. Type 3766 Pneumatic Positioner

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner. with PROFIBUS-PA communication

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Pneumatic control unit for decentralized automation of ELEMENT process valves

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Data Sheet T EN

Type 3967 Solenoid Valve. Safety Manual SH EN

24010, 3/2 Direct solenoid actuated poppet valve

Type Electronic Limit Switch. with optional integrated solenoid valve for on/off valves. Mounting and Operating Instructions EB 8390 EN

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Electropneumatic Positioner Type Fig. 1 Type Mounting and Operating Instructions EB EN

Material pressure (bar) (Cv (US) kv x 1,2 Seat

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Assembly. Trunk IN + - S U, I U, I. Spur 1

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Type 3963 Solenoid Valve. Safety Manual SH 3963 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Mounting and Operating Instructions EB EN. Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series 240 Types PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve

TZIM. Electropneumatic Analog Positioner 10/ EN

Mounting and Operating Instructions EB EN

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Series 240 Type 3351 Pneumatic On/off Valve

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Sensor boxes SRBE Key features and product range overview

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

T 8321 EN Type 3278 Pneumatic Rotary Actuator

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Electropneumatic positioner APIS

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

Our policy is one of continued research and development. We therefore reserve the right

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Operating Instructions

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

EX-D ENCLOSURES AND DISTRIBUTIONS

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Mounting and Operating Instructions EB 5868/5869 EN

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Series 3725 Electropneumatic Positioner Type Type 3725 Positioner. Mounting and Operating Instructions EB 8394 EN

2/2- and 3/2-way solenoid valve for aggressive fluids

97105 Inline. Ordering information. Technical data. Accessories See page 5

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

I Ex-control stations I

Our policy is one of continued research and development. We therefore reserve the right

HERION SERIES Indirect solenoid actuated soft seal

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Differential Pressure and Flow meters Accessories for the Media Series

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

I Ex-safety switches I

Transcription:

Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE 3845 Intrinsically safe, low-power binary signals issued by automation equipment or fieldbus systems can be used for controlling purposes. Different nominal signals and connection types allow the solenoid valve to be optimally adapted for the specific task. Special features High level of operational reliability due to the flapper/ nozzle assembly and booster valve with a seat and plug Standard version for nominal signals 6, 2, V DC Type of protection: intrinsic safety Ex ia and non-sparking Ex na Certification according to ATEX, IECEx, and EAC (GOST) Power consumption: 6 to 27 mw Electrical connection using M6 x.5 cable gland Corrosion-resistant enclosure with degree of protection IP 65 Supply air.4 to 0 bar Ambient temperature 45 to +80 C, depending on type of protection, temperature class and seals Use with safety shut-off valves, certification for safety-instrumented systems according to IEC 6508 (SIL, optional) Versions Version with K VS 0.32 Version with K VS 2.0 Version 3/2-way solenoid valve with K VS 0.32 and NAMUR interface according to VDI/VDE 3845 and VDI/VDE 3847 Attachment to linear actuators with NAMUR rib or to rotary actuators with NAMUR interface Restrictor plate with exhaust air or supply restrictor (optional) 3/2-way booster valve with K VS 2.0 and 4.3 and NAMUR interface according to VDI/VDE 3845 (optional) Aluminum or stainless steel Version with K VS 4.3 Fig. : Type 367 Solenoid Valve Associated Information Sheet u T 8350 Edition May 206 Data Sheet T 367 EN

Solenoid valve version K VS 0.32 K VS 2.0 K VS 4.3 2 3 2 3 2 3 3/2-way function NAMUR interface ¼ 3/2-way function NAMUR interface ¼ 3/2-way function NAMUR interface ½ 2 3 3/2-way function NAMUR interface ¼ Exhaust air restrictor plate 2 3 3/2-way function NAMUR interface ¼ Supply air restrictor plate 2 T 367 EN

Function The solenoid valve consists of an electropneumatic binary converter with manual override and integrated booster valve actuated on one side with return spring. The air supply for the electropneumatic binary converter is routed internally over port or externally over port. By turning a gasket, the supply air routing is changed (see Mounting and Operating Instructions u EB 367). The pressure reducer reduces the supply air pressure to.4 bar. In the idle position, the flapper is lifted off the outlet nozzle by the spring. As a result, a pressure lower than the deactivation pressure of the integrated booster valve builds up in the pressure divider, which consists of the restrictor and outlet nozzle. When the solenoid coil is energized by an electric binary signal, the outlet nozzle is closed by the flapper against the force of the spring. This causes the pressure in the pressure divider to rise above the activation pressure of the integrated booster valve and switches it to the operating position. After the solenoid coil is de-energized, the integrated booster valve is switched to the idle position again by a return spring. Optionally, the solenoid valve can be upgraded to become a pneumatic booster valve actuated on one side. This results in higher K VS coefficients (see Data Sheet u T 3756). Functional diagram Nominal signal Port 3 + External supply air Port Port 2 Port Fig. 2: Solenoid valve with seat/plug switching element as a booster valve (K VS 0.32) T 367 EN 3

Technical data General data Design Solenoid with flapper/nozzle assembly and plug/seat valve with return spring Degree of protection IP 65 with filter check valve Compliance Material Enclosure Polyamide PA 6-3-T-GF35, black Connecting AlMgSiPb, powder coated, black, or stainless steel.4404 plate Adapter plate AlMgSiPb, powder coated, gray beige RAL 0, or stainless steel.4404 Screws Stainless steel A2-70 Springs Stainless steel.430 Seals Silicone rubber Ambient temperature See Electric data Mounting position Any desired position Electric data Nominal signal U N 6 V DC 2 V DC V DC U max 27 V 40 V 60 V Switching point ON U 80 C 4.8 V.6 V 8 V I 20 C.4 ma.52 ma.57 ma P 20 C 5.47 mw 3.05 mw 26.7 mw OFF U 25 C.0 V 2.3 V 4.6 V Input impedance R 20 C 2.6 kω 5.3 kω 0.5 kω Temperature influence 0.4 %/ C 0.2 %/ C 0. %/ C Type of protection ) Intrinsic safety: II 2G Ex ia IIC T6 / II 2D Ex td A2 IP65 T80 C Non-sparking: II 3G Ex na IIC T6 / II 3D Ex td A2 IP65 T80 C Output voltage 2) U i (V) 25 27 28 30 32 Output current 2) I i (ma) 50 25 5 00 85 Power dissipation 2) P i (mw) 250 No restrictions Outer inductance 2) L i Negligibly small Outer capacitance 2) C i Negligibly small Ambient temperature 3) 45 to +60 C (temperature class T6) 45 to +70 C (temperature class T5) 45 to +80 C (temperature class T4) Connection Screw terminal, 2-pole, with cable gland M6 x.5 Pneumatic data for solenoid valve with K VS 0.32, actuated on one side Switching function 3/2-way function 4) K VS 0.32 Safety approval SIL 5) Compressed air quality according to ISO 8573- Max. particle size and density: Class 4 Oil content: Class 3 Pressure dew point: Class 3 or at least 0 K below the lowest ambient temperature to be expected Supply air Medium Instrument air, free from corrosive substances and nitrogen Pressure 6).4 to 0 bar Operating medium Instrument air, free from corrosive substances and nitrogen Operating pressure Max. 0 bar Air consumption 80 l n /h at.4 bar supply air in neutral position 25 l n /h at.4 bar supply air in operating position Switching time 65 ms Connection G ¼ or ¼ NPT and NAMUR interface ¼ 7) Weight 0.45 kg,. kg (with adapter plate) ) According to EC type examination certificate and statement of conformity 2) Permissible maximum values when connected to a certified intrinsically safe circuit. 3) The maximum permissible ambient temperature depends on the permissible ambient temperature of the components, type of protection, and temperature class. 4) The air flow rate when p = 2.4 bar and p 2 =.0 bar is calculated using the following formula: Q = K VS x 36.22 in m³/h. 5) SIL according to IEC 6508 6) When using the solenoid valve with an operating pressure of 0 bar, a minimum supply pressure of. bar is required. 7) NAMUR interface according to VDI/VDE 3845 and VDI/VDE 3847 4 T 367 EN

Technical data Booster valve with NAMUR interface, K VS 2.0 or 4.3, actuated on one side Switching function K VS ) (direction of flow) 3/2-way function. (4»3) 2.0 (3»5). (4»3) 4.3 (3»5) Safety approval SIL² ) Type Poppet valve with diaphragm actuator, soft seated, with return spring Material Enclosure Aluminum, powder coated, gray beige RAL 0, or stainless steel.4404 Diaphragms Chloroprene rubber ( 20 to +80 C) or silicone rubber ( 45 to +80 C) Seals Chloroprene rubber ( 20 to +80 C) or silicone rubber ( 45 to +80 C) Screws Stainless steel.457 Springs Stainless steel.430 Operating medium Instrument air (free from corrosive substances) or nitrogen, air containing oil or non-corrosive gases Compressed air quality according to ISO 8573- Control Supply air Max. operating pressure Ambient temperature 3) 20 to +80 C 45 to +80 C Connection Supply air Exhaust air Max. particle size and density: Class 4 Oil content: Class 3 Pressure dew point: Class 3 or at least 0 K below the lowest ambient temperature to be expected Type 367 Solenoid Valve.4 to 6 bar 0.0 bar G ¼ or ¼ NPT and NAMUR interface ¼ 4) with G 3 /8 / 3 /8 NPT G ½ or ½ NPT and NAMUR interface ½ 4) with G 3 /8 / 3 /8 NPT Approx. weight.38 kg.5 kg G ½ or ½ NPT and NAMUR interface ½ 4) G ½ or ½ NPT and NAMUR interface ½ 4) ) The air flow rate when p = 2.4 bar and p 2 =.0 bar is calculated using the following formula: Q = K VS x 36.22 in m³/h. 2) SIL according to IEC 6508 3) The maximum permissible ambient temperature depends on the permissible ambient temperature of the components, type of protection, and temperature class. 4) NAMUR interface according to VDI/VDE 3845 T 367 EN 5

Dimensions (in mm) Version with NAMUR interface ¼ according to VDI/VDE 3845 and direct attachment according to VDI/VDE 3847 3 2 NAMUR interface ¼ according to VDI/VDE 3845 and 3847 32 G ¼/¼ NPT 6 4.5 58.4 88.6 32 6.6 6.6 6 6 T 367 EN

Dimensions (in mm) Version with NAMUR interface ¼ according to VDI/VDE 3845 and direct attachment according to VDI/VDE 3847 and restrictor plate NAMUR interface ¼ according to VDI/VDE 3845 and 3847 32 G ¼/¼ NPT 4.5 6 78.4 08.6 32 6.6 6.6 6 T 367 EN 7

Dimensions (in mm) Version with adapter plate for linear actuators with NAMUR rib according to IEC 6053-6- M4 for panel mounting M3 for wall or rail mounting 4.2 Ø 8.5 for NAMUR ribs according to IEC 60534-6- 48 38 30.8 52.5 G ¼/¼ NPT G ¼/¼ NPT 3.5 0.5 82.4 3.4 3 2 3.8 6.8 40.4 60 37.2 05 6.6 6 8 T 367 EN

Dimensions (in mm) Version with booster valve (K VS 2.0) 2.8 G ½/½ NPT 30.8. Int.. 32 83.4 5 66 08 22.5 3 2 5 4 23.6 44 26 G ¼/¼ NPT 62 3 6 63 62 NAMUR interface ¼ according to VDI/VDE 3845 G 3 / 8 / 3 / 8 NPT) T 367 EN

Dimensions (in mm) Version with booster valve (K VS 4.3) 2,8 G ½/½ NPT 5.. Int. 4. 45 5 3.8 23 72.5 8 40 20 3 30,8 223.6 44 26 G ½/½ NPT 62 3 6 63 62 NAMUR interface ½ according to VDI/VDE 3845 0 T 367 EN

Article code Solenoid valve Type 367- x x x x x x x x x x x x x x x x x x x x x Type of protection No explosion protection 0 0 0 II 2G Ex ia IIC T6, II 2D Ex td A2 IP65 T80 C, ATEX 0 Ex ia IIC T6/T5/T4, Ex td A2 IP65 T80 C, IECEx 2 0Ex ia IIC T6/T5/T4 Ga, Ex tb IIIC T80 C Db IP65, EAC (GOST) 3 II 3G Ex na II T6, II 3D Ex tc IIIC T80 C Db IP65, ATEX 8 0 Ex na II T6, Ex td A22 IP65 T80 C, IECEx 8 2 2Ex na IIC T6/T5/T4 Gc X, Ex tc IIIC T80 C Dc X, EAC (GOST) 8 3 Nominal signal 6 V DC 2 V DC 2 V DC 3 Manual override Pushbutton underneath the enclosure cover 0 Pushbutton in the enclosure cover Switch in the enclosure cover 2 Without 3 Switching function 3/2-way function with spring-return mechanism 0 0 Mounting NAMUR interface ¼ according to VDI/VDE 3845 for rotary actuators 0 NAMUR rib according to IEC 60534 for linear actuators/threaded connection 2 Direct attachment to connection block with positioner according to VDI/VDE 3847 3 NAMUR interface ½ according to VDI/VDE 3845 for rotary actuators 4 NAMUR interface ¼ according to VDI/VDE 3845 for rotary actuators with adapter plate for external air connections 5 K VS coefficient ) 0.32 0 2.0 2 4.3 4 Material Aluminum Stainless steel 2 Pneumatic connection G ¼ ¼ NPT 2 G ½ 3 ½ NPT 4 Pilot valve connection Without (ports sealed by two blanking plugs) 0 (with internal air supply) 2 (with external air supply) 2 ) The air flow rate when p = 2.4 bar and p 2 =.0 bar is calculated using the following formula: Q = K VS x 36.22 in m³/h. T 367 EN

Solenoid valve Type 367- x x x x x x x x x x x x x x x x x x x x x Supply air Internal air supply for actuators for on/off service 0 External air supply for actuators for throttling service Electrical connection Without cable gland 0 0 Cable gland M6 x.5 made of black polyamide 0 M6 x.5 cable gland made of blue polyamide Cable gland M6 x.5 made of black polyamide (Ex e, CEAG) 3 Cable gland M6 x.5, nickel-plated brass 4 Cable gland M6x.5, brass, blue 5 Degree of protection IP 65 0 Ambient temperature 2) 20 to +80 C 0 45 to +80 C Fail-safe action Without 0 SIL 3) Special version Without 0 0 0 With exhaust air restrictor plate 0 0 With supply air restrictor plate 0 0 2 With exhaust air and supply air restrictor plates 0 0 3 2) The maximum permissible ambient temperature depends on the permissible ambient temperature of the components, type of protection, and temperature class. 3) SIL according to IEC 6508 Summary of explosion protection approvals Type Certification Type of protection/comments 367 SIL No. V 60.0/4 rev. 0 Certification for safety-instrumented systems Date 205-02-0 according to IEC 6508 EC type examination certificate No. PTB 06 ATEX 2027 II 2G Ex ia IIC T6 Date 2007--6 II 2D Ex tb IIIC T80 C IP65 367- No. IECEx PTB 08.0036 Ex ia IIC T6 Date 2008-08-28 Ex td A2 IP65 T80 C No. RU C-DE08.B.005 0Ex ia IIC T6/T5/T4 Ga Date 203--5 Ex tb IIIC T80 C Db EC type examination certificate No. PTB 06 ATEX 2028 X II 3G Ex na II T6 Date 2008-0-0 II 3G Ex ic IIC T6 II 3D Ex tc IIIC T80 C IP65 367-8 No. IECEx PTB 08.0038X Ex na II T6 Date 2008-08-28 Ex nl IIC T6 Ex td A22 IP65 T80 No. RU C-DE08.B.005 2Ex na IIC T6/T5/T4 Gc X Date 203--5 2Ex ic IIC T6/T5/T4 Gc X Ex tc IIIC T80 C Dc X 2 T 367 EN

Accessories and spare parts Spare parts Order no. Designation 08-527 Enclosure cover with pushbutton 08-528 Enclosure cover with switch 0-6236 Enclosure cover 0430-4 Gasket (for enclosure cover) 0070-0858 Blanking plug G ¼, stainless steel.457 (for threaded connections) 0070-0862 Blanking plug ¼ NPT, stainless steel.457 (for threaded connections) 842-0070 O-ring 4 x.5 made of nitrile butadiene rubber (for blanking plug) 0430-884 Turnable gasket (for connecting plate) 8336-08 Screw DIN 764, 5 x 20 (for connecting plate) 0550-023 Filter ¼ (for connecting plate) 0430-883 Formed seal (for NAMUR interface ¼, K VS 0.32) 842-0364 O-ring 6 2, 20 to +80 C (for booster valves with NAMUR interface ¼, K VS 2.0) 842-0368 O-ring 6 2, 45 to +80 C (for booster valves with NAMUR interface ¼, K VS 2.0) 842-077 O-ring 2, 20 to +80 C (for booster valves with NAMUR interface ½, K VS 4.3) 842-0425 O-ring 2, 45 to +80 C (for booster valves with NAMUR interface ½, K VS 4.3) 8333-303 Screw M5 60 A4 (for booster valves with NAMUR interface, K VS 2.0) 832-065 Spring washer A5-A4 (for booster valves with NAMUR interface, K VS 2.0) 8333-0538 Screw M5 60 A4 (for booster valves with NAMUR interface, K VS 4.3) 832-0658 Spring washer A5-A4 (for booster valves with NAMUR interface, K VS 4.3) Accessories Order no. Designation 8808-00 Cable gland M6 x.5 made of black polyamide, 5 to 0 mm cable diameter 8808-2007 Cable gland M6 x.5 made of black polyamide, 5.5 to 0 mm cable diameter (Ex e, CEAG) 8808-2008 Cable gland M6 x.5 made of blue polyamide, 4 to 8 mm cable diameter 8808-200 Cable gland M6 x.5, nickel-plated brass, 4 to 8 mm cable diameter -647 Cable gland M6 x.5, brass, blue, 4 to 8 mm cable diameter 8808-20 Extension cable gland M6 x.5 on M20, black polyamide, 5.5 to 3 mm cable diameter ( 20 to +70 C) (Ex e) 8808-0 Blanking plug M6 x.5, black polyamide (for cable entry) 842-0070 O-ring 4 x.5 made of nitrile butadiene rubber (for cable gland and blanking plug) 402-378 Cover for start-up T 367 EN 3

Accessories and spare parts Accessories for K VS 0.32 Order no. Designation Adapter plate for NAMUR rib according to IEC 60534-6-, panel, wall or rail mounting, including fastening screw 400-58 Aluminum, powder coated, gray beige RAL 0, G ¼ connection 400-5 Aluminum, powder coated, gray beige RAL 0, ¼ NPT connection 400-600 Stainless steel.4404, G ¼ connection 400-60 Stainless steel.4404, ¼ NPT connection Mounting base according to EN 6075 400-530 G-profile rail 32 (2 pcs. required) 400-53 For 35 mm top-hat rail mounting (2 pcs. required) 400-6726 Mounting plate for wall mounting including fastening screws Restrictor plate 400-602 With exhaust air restrictor, K VS 0.0 to 0.28, adjustable; made of aluminum, powder coated, gray beige RAL 0 402-04 With exhaust air restrictor, K VS 0.0 to 0.28, adjustable; made of aluminum, powder coated, gray beige RAL 0, SIL 402-037 With exhaust air restrictor, K VS 0.0 to 0.28, adjustable; made of stainless steel.4404 402-042 With exhaust air restrictor, K VS 0.0 to 0.28, adjustable; made of stainless steel.4404, SIL 400-603 With supply air restrictor, K VS 0.0 to 0.28, adjustable; made of aluminum, powder coated, gray beige RAL 0 402-03 With supply air restrictor, K VS 0.0 to 0.28, adjustable; made of aluminum, powder coated, gray beige RAL 0, SIL 402-036 With supply air restrictor, K VS 0.0 to 0.28, adjustable; made of stainless steel.4404 402-040 With supply air restrictor, K VS 0.0 to 0.28, adjustable; made of stainless steel.4404, SIL Adapter plate for NAMUR interface ¼ on NAMUR rib ¼ with external connections 402-065 Aluminum, powder coated, gray beige RAL 0, G ¼ connection 402-067 Aluminum, powder coated, gray beige RAL 0, ¼ NPT connection 402-066 Stainless steel.4404, G ¼ connection 402-068 Stainless steel.4404, ¼ NPT connection Double-axial adapter 3-008 0, aluminum, powder coated, gray beige RAL 0 3-0220 270, aluminum, powder coated, gray beige RAL 0 402-0280 80, aluminum, powder coated, gray beige RAL 0 Adapter plate for NAMUR interface ¼ on NAMUR rib ½ 380-652 Aluminum, powder coated, gray beige RAL 0 380-77 Stainless steel.4404 Adapter plate with NAMUR interface ¼ 402-005 For SAMSON Type 335 40-300 For SAMSON Type 3353 and Type 3354 8333-237 Hexagon socket head screw M5 x 6 (required in addition to 40-300) 070-68 M5 seal (required in addition to 40-300) 4 T 367 EN

Accessories and spare parts Accessories for K VS 0.32 Order no. Designation Mounting block for SAMSON Type 3277 Pneumatic Actuator, 400-887 G ¼ connection 400-888 ¼ NPT connection 400-650 Pressure gauge mounting block, x Output and x Supply, made of stainless steel/brass (for mounting block) Piping for actuator with fail-safe action "stem retracts" 400-6444 0 cm² actuator area, zinc-coated steel 400-6445 0 cm² actuator area, CrNiMo steel 400-6446 350 cm² actuator area, zinc-coated steel 400-6447 350 cm² actuator area, CrNiMo steel 400-6448 700 cm² actuator area, zinc-coated steel 400-644 700 cm² actuator area, CrNiMo steel Accessories for K VS 2.0 Order no. Designation Adapter plate for NAMUR rib acc. to IEC 6053-6- 400-675 Aluminum, powder coated, gray beige RAL 0, G ¼ connection 400- Aluminum, powder coated, gray beige RAL 0, ¼ NPT connection Adapter plate for NAMUR interface ¼ on NAMUR rib ½ 380-652 Aluminum, powder coated, gray beige RAL 0 380-77 Stainless steel.4404 Accessories for K VS 4.3 Order no. Designation Adapter plate for NAMUR interface ½ to thread ½ 0360-345 Aluminum, powder coated, gray beige RAL 0, G ½ connection 0360-346 Aluminum, powder coated, gray beige RAL 0, ½ NPT connection 0360-347 Stainless steel.4404, G ½ connection 0360-348 Stainless steel.4404, ½ NPT connection Adapter plate for NAMUR interface ½ on NAMUR rib ¼ 380-75 Aluminum, powder coated, gray beige RAL 0 380-76 Stainless steel.4404 Adapter plate for NAMUR rib acc. to IEC 6053-6- 402-0827 Aluminum, powder coated, gray beige RAL 0, G ½ connection 402-082 Aluminum, powder coated, gray beige RAL 0, ½ NPT connection 402-0828 Stainless steel.4404, G ½ connection 402-0830 Stainless steel.4404, ½ NPT connection Double-axial adapter 402-0602 0, aluminum, powder coated, gray beige RAL 0 402-0603 0, stainless steel.4404 T 367 EN 5

Specifications subject to change without notice. SAMSOMATIC GMBH A member of the SAMSON GROUP Weismüllerstraße 20-22 6034 Frankfurt am Main, Germany Phone: +4 6 400-0 Fax: +4 6 400-644 samsomatic@samsomatic.de www.samsomatic.de T 367 EN 206-05-30 English