/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated rectifier (40... 60 Hz) These solenoid valves are applicable in Ex protection class ATEX (categories II GD and II 3 GD) and other international approvals Approval depends on magnetic system, see pages 3 to 6! Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operation: Direct solenoid operated poppet valves Mounting position: Optional, preferably with solenoid on top Orifice:,5... mm Port size: G /4, /4 NPT, G / Operating pressure: 0... 40 bar Fluid/Ambient Temperature: -5... +80 C (NBR) -0...+0 C (FKM) - Water +95 C -40... +40 C (EPDM) -0...+40 C (FFKM) -50...+80 C (PTFE) Depending on solenoid system and seal materials Air supply must be dry enough to avoid ice formation at temperatures below + C. Materials: Housing: brass.040 (Ms 58) Seals: NBR (Perbunan), other see option selector Inner parts: steel.404 (0 F), brass.040 (Ms 58) Further versions Operating pressure to 50 bar; For temperatures from -50... +80 C; Seat seals FKM, EPDM, FFKM, PTFE, Rubin; Assembled oil and grease-free Technical data Switching function: Normally closed Symbol Port size Orifice Operating pressure Flow Weight without Dimension Solenoid *) (mm) (bar) min. max. (l/min) Solenoid (kg) group *) G/4,5 0 40 70 0, 3B 950000 G/4 0 35 0 0, 3B 950000 /4 NPT 0 35 0 0, 3B 950300 G/4 3 0 0 00 0, 3C 9500300 /4 NPT 3 0 0 00 0, 3C 9503300 G/4 4 0 350 0, 3D 9500400 /4 NPT 4 0 350 0, 3D 9503400 G/4 6 0 5 550 0,5 6D 950600 /4 NPT 6 0 5 550 0,5 6D 9504600 G/ 0 700 0,8 4 6D 950700 Switching function: Normally open Symbol Port size Orifice Operating pressure Flow Weight without Dimension Solenoid *) (mm) (bar) min. max. (l/min) Solenoid (kg) group *) G/4 0 0 00 0, 3 3B 9500 G/4 3 0 0 60 0, 3 3B 95030 *) When ordering please indicate solenoid, voltage and current type (frequency). *) Technical data and ordering information see following pages. / N/en 5.4.304.0
Option selector 950X X... Orifice,5 3 3 4 4 6 6 7 Material seat seal NBR (Perbunan) 0 EPDM FKM (Viton) PTFE (Teflon) (DN,5-4) NC 3 FFKM (Kalrez) 4 Rubin (DN+3) NC 5 Frequency (Hz) At d.c. 00 At a.c. (40... 60 Hz) 50 Voltage 4 V d.c. 04 30 V a.c. 30 Solenoid operators See table N/en 5.4.304.0 /
Solenoid operators, solenoids group 3B Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 8,0-33 - - IP 65 mit connector *5) - 9, - 40 - IP 65 mit connector *5) 8,0-33 - II3G - 9, - 40 II3G 6,9-89 - IIG - 8,7-34 IIG 3,9-6 - IIG - 5,3-3 IIG 3,9-6 - IIG - 5,3-3 IIG 3,9-6 - IIG - 5,3-3 IIG Ex td A IP65 T 0 C Ex td A IP65 T 0 C Ex mb II T4 T 0 C *) Ex mb II T4 T 0 C *) T30 C *), *0) T30 C *), *0) 5,5 - - 8 - XP/DIP, Div. & T3 (60 C) *4) - 5,9-6 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate PTB 06 ATEX 054 X *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) Weight (kg) Dimension Circuit diagram 0,5 046 0,6 7 306-0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery 0,6 36-0... +60 Special connector 0,6 6 38 DIN EN 7530-803, Form A indicated in delivery -0... +60 Cable 3 m long 0,4 5 4 09-0... +60 Cable 3 m long 0,4 5 7 093 M0 x,5 *6) 0,5 6 4 40 M0 x,5 *6) 0,5 6 7 4 /-4 NPT *6) 0,8 7 4 460 /-4 NPT *6) 0,8 7 7 46 M0 x,5 *6) 0,8 7 4 46 M0 x,5 *6) 0,8 7 7 463-0... +60 Flying leads 450 mm long 0,5 8 37-0... +60 Flying leads 450 mm long 0,5 8 5 373 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. / N/en 5.4.304.03
Solenoid operators, solenoids group 3C Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7), - 504 - - IP 65 (with -,3-49 - IP 65 (with, - 504 - II3G -,3-49 II3G 0,7-446 - IIG -,4-54 IIG 8,9-369 - IIG - 0,0 - IIG 8,9-369 - IIG - 0,0 - IIG 8,9-369 - IIG - 0,0 - IIG Ex td A IP65 T 30 C Ex td A IP65 T 0 C Ex mb II T4 T 0 C *) Ex mb II T4 T 0 C *) T30 C *), *0) T30 C *), *0) ) 8,9-369 - - XP/DIP, Div. & T3 (60 C) *4) - 9,5-4 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate PTB 06 ATEX 054 X *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) Weight (kg) Dimension Circuit diagram 0,7 000 0,60 6 304-0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery 0,7 37-0... +50 Special connector 0,7 6 39 DIN EN 7530-803, Form A indicated in delivery -0... +40 3 m cable 0,4 5 4 090-0... +40 3 m cable 0,4 5 7 09-40... +65 T4-40... +55 T5-40... +65-40... +65 T4-40... +55 T5-40... +65-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70 M0 x,5 *6) 0,5 6 4 40 M0 x,5 *6) 0,5 6 7 4 /-4 NPT *6) 0,8 7 4 460 /-4 NPT *6) 0,8 7 7 46 M0 x,5 *6) 0,8 7 4 46 M0 x,5 *6) 0,8 7 7 463-0... +60 Flying leads 450 mm long -0... +60 Flying leads 450 mm long 0,5 8 374 0,5 8 5 375 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. N/en 5.4.304.04 /
Solenoid operators, solenoids group 3D Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 6,9 -- 703 - - IP 65 (with - 7,3-75 - IP 65 (with,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG *), *0) T30 C *), *0) *), *0) T30 C *), *0) 3,6-567 - - XP/DIP, Div. & T3 (60 C) *4) - 5,7-68 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6)) -0... +60 Flying leads 450 mm long Weight (kg) Dimension Circuit diagram 0,7 3 0700 DIN EN 7530-803, Form A *6) 0,3 4 6 3703 M0 x,5 *6) 0,5 6 4 0 M0 x,5 *6) 0,5 6 7 / x 4 NPT *6) 0,8 7 4 4630 / x 4 NPT *6) 0,8 7 7 463 / x 4 NPT *6) 0,8 7 4 463 M0 x,5 *6) 0,8 7 7 4633-0... +60 Flying leads 450 mm long 0,5 8 376 0,5 8 5 377 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. / N/en 5.4.304.05
Solenoid operators, solenoids group 6D Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 6,9-703 - - IP 65 (with - 7,3-75 - IP 65 (with 6,9-703 - II3G - 7,3-75 II3G,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG Ex td A IP65 T 30 C Ex td A IP65 T 0 C *), *0) T30 C *), *0) *), *0) T30 C *), *0) 3,6-567 - - XP/DIP, Div. & T3 (60 C) *4) *4) - 5,7-68 - XP/DIP, Div. & T3 (60 C) *4) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) -0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery -0... +50 Special connector DIN EN 7530-803, Form A indicated in delivery -0... +60 Flying leads 450 mm long -0... +60 Flying leads 450 mm long Weight (kg) Dimension Circuit diagram 0,6 3 0800 0,35 4 6 3803 0,7 3 387 0,36 4 6 389 M0 x,5 *6) 0,5 6 4 480 M0 x,5 *6) 0,5 6 7 48 / x 4 NPT *6) 0,8 7 4 4680 / x 4 NPT *6) 0,8 7 7 468 M0 x,5 *6) 0,8 7 4 468 M0 x,5 *6) 0,8 7 7 4683 0,5 8 386 0,5 8 5 387 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. N/en 5.4.304.06 /
Accessories Cable gland Protection class Ex e, Ex d (ATEX), Page 9 Thread Cable Ø Material Protection class (ATEX) M 0x,5 5,0...8,0 mm Nickel plated brass IIGD Ex e 058889 057075 M 0x,5 0...4 mm Nickel plated brass IIGD Ex d 058885 /-4-NPT 7,5...,9 mm Nickel plated brass IIGD Ex d 058895 Dimensions Valves 8 8 8 7 9 9,5 75,5 ~ 0 8 9 ~ 0 8,5 9,5 36 36 G /4 6 3 8 4 8 7 9 7 9 9,5 46,5 36 9, ~ 0 ~ 86 ~ 40 75 G / ~ 5,4 ~ 0 M4 x 6 mm deep / N/en 5.4.304.07
Dimensions Solenoid operators 38 7 46 79 9,5 4,5 5,5 M6 X,5 8 7 M6 X,5 9,5 8 8 8 3 53,5 49 86,5 4 63,5 59 96,5 34 48 M6 X,5 8 7 5 6 07 33 9,5 4 64,5 8,5 89 54,5 34 7 M6 x,5 8 7 7 M 0 x,5 4 9,5 63,5 73 can be indexed by 4x90 Ø 6 or 3 (with spacer tube) N/en 5.4.304.08 /
7 8 70,5 / - 4 NPT 0 4,5 59 56 3 84 63 33,5 9 6 4 Ø 6 or 3 (with spacer tube) 3 M0 x,5 or / - 4 NPT 4 Flying leads AWG 8 (450 mm long) Circuit diagrams 4 5 6 7 Cable gland C B A D C B A D A B C ø D M0 x,5 9 36 5... 8 058889 M0 x,5 4 39 0... 4 4 058885 /-4 NPT 5 58 7,5...,9 4 058895 058895 only Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en 5.4.304.09