Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Similar documents
Operating pressure (bar) kv factor (m 3 /h) *3)

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

97105 Inline. Ordering information. Technical data. Accessories See page 5

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

97100 NAMUR. Technical data

25000, 4/2 Direct solenoid actuated poppet valves

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

High pressure valves. 80 to 350 bar

24010, 3/2 Direct solenoid actuated poppet valve

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right

2/2 Pressure operated valves

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Hydraulic pressure switch 20D Acc. to ATEX

HERION SERIES Indirect solenoid actuated soft seal

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

/2-way piston valves

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Direct-acting 2/2- or 3/2-way pivoted armature valve

Technical Data Sheet

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Direct-acting 2/2-way plunger valve

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

Nugget 40, V08 series

2/2-way Solenoid Valve for liquids and gases

/2-way piston valves

Direct-acting 3/2 way plunger valve

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2- and 3/2-way solenoid valve for aggressive fluids

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

N/** поставка оборудования для подготовки воздуха

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Weight (kg) Model L92C- P-ETN. N/en

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

86740/ /2-way piston valves

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Allfluid pressure switches 20D to ATEX

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

82610/ /2-way seat valves

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Servo-operated 2/2-way solenoid valves Type EV220A

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Engineering GREAT Solutions

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Brass ball valves 60 series

Type 6213 EV, 6281 EV

3/2-way Solenoid Valve, direct-acting, NC or NO

2/2 or 3/2 way direct acting rocker solenoid valve

Solenoid System FLANGE MOUNTING VERSION

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

2/2-way Solenoid Valve with servo diaphragm

Motorised Valve Range

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Fluid Control Contents

AUTO STAR with central connector M12x1

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Acoustic Signals Industrial Airhorns > AP Series Product overview

Excel V03, V04 and V05 Series

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

Ex m Solenoid Operator Type 0519

Sentronic PLUS 614 Series

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

3/2-way Rocker Solenoid Valve for pneumatic systems

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

18D according to ATEX

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

82170/ /2-way diaphgram valves

, /2 Soft start ( soft clutch ) valve

Transcription:

/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated rectifier (40... 60 Hz) These solenoid valves are applicable in Ex protection class ATEX (categories II GD and II 3 GD) and other international approvals Approval depends on magnetic system, see pages 3 to 6! Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operation: Direct solenoid operated poppet valves Mounting position: Optional, preferably with solenoid on top Orifice:,5... mm Port size: G /4, /4 NPT, G / Operating pressure: 0... 40 bar Fluid/Ambient Temperature: -5... +80 C (NBR) -0...+0 C (FKM) - Water +95 C -40... +40 C (EPDM) -0...+40 C (FFKM) -50...+80 C (PTFE) Depending on solenoid system and seal materials Air supply must be dry enough to avoid ice formation at temperatures below + C. Materials: Housing: brass.040 (Ms 58) Seals: NBR (Perbunan), other see option selector Inner parts: steel.404 (0 F), brass.040 (Ms 58) Further versions Operating pressure to 50 bar; For temperatures from -50... +80 C; Seat seals FKM, EPDM, FFKM, PTFE, Rubin; Assembled oil and grease-free Technical data Switching function: Normally closed Symbol Port size Orifice Operating pressure Flow Weight without Dimension Solenoid *) (mm) (bar) min. max. (l/min) Solenoid (kg) group *) G/4,5 0 40 70 0, 3B 950000 G/4 0 35 0 0, 3B 950000 /4 NPT 0 35 0 0, 3B 950300 G/4 3 0 0 00 0, 3C 9500300 /4 NPT 3 0 0 00 0, 3C 9503300 G/4 4 0 350 0, 3D 9500400 /4 NPT 4 0 350 0, 3D 9503400 G/4 6 0 5 550 0,5 6D 950600 /4 NPT 6 0 5 550 0,5 6D 9504600 G/ 0 700 0,8 4 6D 950700 Switching function: Normally open Symbol Port size Orifice Operating pressure Flow Weight without Dimension Solenoid *) (mm) (bar) min. max. (l/min) Solenoid (kg) group *) G/4 0 0 00 0, 3 3B 9500 G/4 3 0 0 60 0, 3 3B 95030 *) When ordering please indicate solenoid, voltage and current type (frequency). *) Technical data and ordering information see following pages. / N/en 5.4.304.0

Option selector 950X X... Orifice,5 3 3 4 4 6 6 7 Material seat seal NBR (Perbunan) 0 EPDM FKM (Viton) PTFE (Teflon) (DN,5-4) NC 3 FFKM (Kalrez) 4 Rubin (DN+3) NC 5 Frequency (Hz) At d.c. 00 At a.c. (40... 60 Hz) 50 Voltage 4 V d.c. 04 30 V a.c. 30 Solenoid operators See table N/en 5.4.304.0 /

Solenoid operators, solenoids group 3B Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 8,0-33 - - IP 65 mit connector *5) - 9, - 40 - IP 65 mit connector *5) 8,0-33 - II3G - 9, - 40 II3G 6,9-89 - IIG - 8,7-34 IIG 3,9-6 - IIG - 5,3-3 IIG 3,9-6 - IIG - 5,3-3 IIG 3,9-6 - IIG - 5,3-3 IIG Ex td A IP65 T 0 C Ex td A IP65 T 0 C Ex mb II T4 T 0 C *) Ex mb II T4 T 0 C *) T30 C *), *0) T30 C *), *0) 5,5 - - 8 - XP/DIP, Div. & T3 (60 C) *4) - 5,9-6 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate PTB 06 ATEX 054 X *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) Weight (kg) Dimension Circuit diagram 0,5 046 0,6 7 306-0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery 0,6 36-0... +60 Special connector 0,6 6 38 DIN EN 7530-803, Form A indicated in delivery -0... +60 Cable 3 m long 0,4 5 4 09-0... +60 Cable 3 m long 0,4 5 7 093 M0 x,5 *6) 0,5 6 4 40 M0 x,5 *6) 0,5 6 7 4 /-4 NPT *6) 0,8 7 4 460 /-4 NPT *6) 0,8 7 7 46 M0 x,5 *6) 0,8 7 4 46 M0 x,5 *6) 0,8 7 7 463-0... +60 Flying leads 450 mm long 0,5 8 37-0... +60 Flying leads 450 mm long 0,5 8 5 373 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. / N/en 5.4.304.03

Solenoid operators, solenoids group 3C Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7), - 504 - - IP 65 (with -,3-49 - IP 65 (with, - 504 - II3G -,3-49 II3G 0,7-446 - IIG -,4-54 IIG 8,9-369 - IIG - 0,0 - IIG 8,9-369 - IIG - 0,0 - IIG 8,9-369 - IIG - 0,0 - IIG Ex td A IP65 T 30 C Ex td A IP65 T 0 C Ex mb II T4 T 0 C *) Ex mb II T4 T 0 C *) T30 C *), *0) T30 C *), *0) ) 8,9-369 - - XP/DIP, Div. & T3 (60 C) *4) - 9,5-4 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate PTB 06 ATEX 054 X *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) Weight (kg) Dimension Circuit diagram 0,7 000 0,60 6 304-0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery 0,7 37-0... +50 Special connector 0,7 6 39 DIN EN 7530-803, Form A indicated in delivery -0... +40 3 m cable 0,4 5 4 090-0... +40 3 m cable 0,4 5 7 09-40... +65 T4-40... +55 T5-40... +65-40... +65 T4-40... +55 T5-40... +65-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70-40... +70 T4-40... +40 T6-40... +70 M0 x,5 *6) 0,5 6 4 40 M0 x,5 *6) 0,5 6 7 4 /-4 NPT *6) 0,8 7 4 460 /-4 NPT *6) 0,8 7 7 46 M0 x,5 *6) 0,8 7 4 46 M0 x,5 *6) 0,8 7 7 463-0... +60 Flying leads 450 mm long -0... +60 Flying leads 450 mm long 0,5 8 374 0,5 8 5 375 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. N/en 5.4.304.04 /

Solenoid operators, solenoids group 3D Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 6,9 -- 703 - - IP 65 (with - 7,3-75 - IP 65 (with,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG *), *0) T30 C *), *0) *), *0) T30 C *), *0) 3,6-567 - - XP/DIP, Div. & T3 (60 C) *4) - 5,7-68 - XP/DIP, Div. & T3 (60 C) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6)) -0... +60 Flying leads 450 mm long Weight (kg) Dimension Circuit diagram 0,7 3 0700 DIN EN 7530-803, Form A *6) 0,3 4 6 3703 M0 x,5 *6) 0,5 6 4 0 M0 x,5 *6) 0,5 6 7 / x 4 NPT *6) 0,8 7 4 4630 / x 4 NPT *6) 0,8 7 7 463 / x 4 NPT *6) 0,8 7 4 463 M0 x,5 *6) 0,8 7 7 4633-0... +60 Flying leads 450 mm long 0,5 8 376 0,5 8 5 377 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. / N/en 5.4.304.05

Solenoid operators, solenoids group 6D Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (ma) (ma) Ex-Protection (ATEX- Category) Protection class *7) 6,9-703 - - IP 65 (with - 7,3-75 - IP 65 (with 6,9-703 - II3G - 7,3-75 II3G,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG,4-475 - IIG - 5, - 66 IIG Ex td A IP65 T 30 C Ex td A IP65 T 0 C *), *0) T30 C *), *0) *), *0) T30 C *), *0) 3,6-567 - - XP/DIP, Div. & T3 (60 C) *4) *4) - 5,7-68 - XP/DIP, Div. & T3 (60 C) *4) *4) Standard voltages 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) EG-Type-Examination-Certificate KEMA 98 ATEX 445 X *3) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *4) CSA-LR 576-6, FM Approval *5) Required connector: type 057075 *6) cable gland not supplied, see table»accessories«*7) IP-Protection class according to EN6059 Suitable for outdoor installation *0) IEC Ex Certificate of Conformity Temperature Ambient/ Fluid ( C) -5... +60-5... +60 Electrical connection DIN EN 7530-803, Form A *6) DIN EN 7530-803, Form A *6) -0... +60 Special connector DIN EN 7530-803, Form A indicated in delivery -0... +50 Special connector DIN EN 7530-803, Form A indicated in delivery -0... +60 Flying leads 450 mm long -0... +60 Flying leads 450 mm long Weight (kg) Dimension Circuit diagram 0,6 3 0800 0,35 4 6 3803 0,7 3 387 0,36 4 6 389 M0 x,5 *6) 0,5 6 4 480 M0 x,5 *6) 0,5 6 7 48 / x 4 NPT *6) 0,8 7 4 4680 / x 4 NPT *6) 0,8 7 7 468 M0 x,5 *6) 0,8 7 4 468 M0 x,5 *6) 0,8 7 7 4683 0,5 8 386 0,5 8 5 387 Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. N/en 5.4.304.06 /

Accessories Cable gland Protection class Ex e, Ex d (ATEX), Page 9 Thread Cable Ø Material Protection class (ATEX) M 0x,5 5,0...8,0 mm Nickel plated brass IIGD Ex e 058889 057075 M 0x,5 0...4 mm Nickel plated brass IIGD Ex d 058885 /-4-NPT 7,5...,9 mm Nickel plated brass IIGD Ex d 058895 Dimensions Valves 8 8 8 7 9 9,5 75,5 ~ 0 8 9 ~ 0 8,5 9,5 36 36 G /4 6 3 8 4 8 7 9 7 9 9,5 46,5 36 9, ~ 0 ~ 86 ~ 40 75 G / ~ 5,4 ~ 0 M4 x 6 mm deep / N/en 5.4.304.07

Dimensions Solenoid operators 38 7 46 79 9,5 4,5 5,5 M6 X,5 8 7 M6 X,5 9,5 8 8 8 3 53,5 49 86,5 4 63,5 59 96,5 34 48 M6 X,5 8 7 5 6 07 33 9,5 4 64,5 8,5 89 54,5 34 7 M6 x,5 8 7 7 M 0 x,5 4 9,5 63,5 73 can be indexed by 4x90 Ø 6 or 3 (with spacer tube) N/en 5.4.304.08 /

7 8 70,5 / - 4 NPT 0 4,5 59 56 3 84 63 33,5 9 6 4 Ø 6 or 3 (with spacer tube) 3 M0 x,5 or / - 4 NPT 4 Flying leads AWG 8 (450 mm long) Circuit diagrams 4 5 6 7 Cable gland C B A D C B A D A B C ø D M0 x,5 9 36 5... 8 058889 M0 x,5 4 39 0... 4 4 058885 /-4 NPT 5 58 7,5...,9 4 058895 058895 only Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en 5.4.304.09