Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

Similar documents
Supplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Supplementary instructions. Centering. for VEGAFLEX series 80. Document ID: 44967

Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Mounting bracket KV 31. For tubes with ø mm Horizontal sensor mounting. Document ID: 41407

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Supplementary instructions Heating for the display and adjustment module PLIC- SCOM

Supplementary instructions. Mounting bracket KV 31. For tubes with ø mm 30 diagnonal irradiation. Document ID: 41863

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Operating Instructions Flexdip CYA112

Product information. Capacitive. Level measurement in bulk solids VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Document ID: 30139

In area - A -, a proper seal must be made against the top of the window glass.

Bicolour level gauge. Type BU green/red. D-04-B EN-1 Edition 05/11

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Operating Instructions OPTISWITCH 4000 C with transistor output

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

Operating Instructions VEGABAR 67

Operating Instructions

OPERATING INSTRUCTIONS

Original operating manual

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

SENSOFIT RET 5000 Technical Datasheet

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Type 2000, 2002, 2012

ROWEKO LOAD-SECURING EQUIPMENT

Industrial flue gas probes. Instruction manual

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Operating Instructions 07/2013

Quick setup guide VEGAPULS 64. Radar sensor for continuous level measurement of liquids ma/hart - two-wire. Document ID: 51462

GS-37 FLARE FLANGE SYSTEM

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

Operating Instructions VEGASWING 66. Vibrating level switch for liquids under extreme process temperatures and pressures

Operating Instructions VEGABAR 67

Installation instructions, accessories - Rear Seat Entertainment

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

D58 Series Brake Instructions

MULTILUBE SYSTEM INSTALLATION AND MAINTENANCE

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Mounting and Operating Instructions EB 5868/5869 EN

Gas springs an overview

Power Transmission. Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM. E e.

NRG 16-12, NRG 17-12, NRG 19-12

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Rotary feed-through DDF-S/-KS

CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

TIDALFLUX 2300 F Quick Start

HV Gate Valve with pneumatic actuator

Pneumatic Corner Drill

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Type N550 Snappy Joe Emergency Shutoff Valves

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

155 CARTRIDGE SINGLE SEAL

Linear unit, pneumatic KHM 40

Operating Instructions VEGASOURCE 31. Source holder. Document ID: 38131

Rotary feed-through DDF 2

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

TOYOTA TRUCKS / SUVs COLD AIR INTAKE Section I Installation Preparation. 4.0L V6 (1GR-FE) Part Number(s): PTR

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output

2-finger angular gripper PWG

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Instruction Manual September 2010 SITRANS LVL200S

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

Type 3320, Service Manual. Serviceanleitung Service Manuel

Operating Instructions OPTISWITCH 5200 C, 5250 C

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Condensate Drain Valve AK 45. Original Installation Instructions English

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP) With SIL qualification

FPC815 Pneumatic Rivet Tool

Level Electrode NRG NRG NRG NRG

Siemens Drives & PLCs

Operating Instruction for Flowmonitor. Model: DF-WM

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Removing and installing trim panel

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

GROUP 9 BOOM, ARM AND BUCKET CYLINDER

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP)

OPTIFLUX 2000 Quick Start

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Compensation unit AGE-XY 50-80

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

NCR ma/hart four-wire

GENUINE REAR SPOILER

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET

RUGBY HOIST CYLINDERS SERVICE BULLETIN

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Operating Instructions April 2008 SITRANS LVL100

Transcription:

Supplementary instructions Air cooling - FIBERTRAC 31 Active air cooling system for radiation-based sensors Document ID: 50339

Contents Contents 1 Product description 1.1 Configuration... 3 2 Mounting 3 Replacement parts 3.1 Available spare parts - air cooling... 17 4 Supplement 4.1 Technical data... 18 4.2 Dimensions... 20 2 Editing status: 2016-10-06

1 Product description 1 Product description 1.1 Configuration The active air cooling system is suitable for radiation-based sensors of series FIBERTRAC 31. The air cooling system consists of several modules. Housing cooling box (A) Housing cooling (B) Scintillator cooling (C) The housing cooling box is placed above the instrument housing and enables cooling of the instrument housing. The cooling module for the housing is also cooled by the housing cooling box (A). The flexible cooling module for the scintillator cools the active measuring part of the sensor. A B C Scope of delivery Fig. 1: Active air cooling system with fastening bracket A Housing cooling box B Housing cooling C Scintillator cooling (flexible) The following parts belong to the scope of delivery of the air cooling system: 3

1 Product description Scintillator cooling hose (1 piece) Flange, sectioned (2 pieces) Spring ring for M5 (6 pieces) Compression nut, top (1 piece) Fastening bracket Isolating sleeve (6 pieces) Fixing screw M8 x 35 (2 pieces) Fixing screw M8 x 40 (4 pieces) Washer for M8 (10 pieces) Spring ring for M8 (2 pieces) cooling box cooling Blind plug ¼" (3 pcs.) Hexagon socket screw M5 x 12 (6 pieces) Hexagon socket screw M5 x 14 (6 pieces) Sealing ring ø 42 x 6 mm (2 pieces) Compression nut, bottom (1 piece) Mounting clamp (quantity depending on sensor length) Housing cooling box with detachable lid Hexagon nut M8, self-locking (4 pieces) Eddy current cooler (type FOS 208SS 25 HVE BSP) for housing Eddy current cooler (type FOS 208SS 35 HVE BSP) for scintillator NPT threaded adapter for vortex cooler (optional) Hook wrench size 68-75, DIN 1810, Form B Information: When the sensor is ordered with cooling, the sensor and the air cooling system are shipped pre-assembled. If the air cooling system is ordered later, you have to mount it on the sensor yourself. You can find further information in chapter "Mounting". 4

2 Mounting 2 Mounting Operating instructions Mounting preparations Take note of the operating instructions manuals of the corresponding radiation-based sensors and the source holder. Warning: During all mounting and dismounting work, the source container must be in switch position "OFF" and secured by a lock. Carry out all work within the shortest possible time and at the largest possible distance. Provide suitable shielding. Avoid risk to other persons by taking suitable measures (e.g. safety fence, etc.). Mounting may only be carried out by authorized, qualified personnel who are monitored for radiation exposure according to local laws or the handling permit. Take note of the specifications in the handling permit. Also take the local conditions into account. Caution: The cooling system is used in areas with high temperatures. Therefore, use temperature-resistant cable and install it in such a way that contact with hot components is avoided. General mounting instructions Information: When the sensor is ordered with cooling, the sensor and the air cooling system are shipped pre-assembled. If the air cooling system is ordered later, you have to mount it on the sensor yourself. Mount the fastening bracket Required tools: Hook wrench size 68-75, DIN 1810, Form B - for screwing on the scintillator cooling hose (comes with the air cooling system) Allen key size 4 - for the bisectional holding flange Fork wrench SW10 mm - for the mounting clip Fork wrench SW13 mm (2 pieces) - for the housing cooling Fork wrench SW19 mm (2 pcs.) - for vortex coolers Acid-free grease - to screw in the compression nuts more easily Take note of the following general mounting instructions: First of all, mount the fastening bracket and the housing cooling, and then the sensor. The small lid of the instrument housing must point to the front after mounting the fastening bracket (x) The sensor together with the air cooling system is very heavy. Use a suitable lifting device for mounting, e.g. a hoisting sling To avoid penetration of moisture and dirt, you should remove the protective caps of the connection openings just before connection Mounting 1. Place the isolating sleeves (4) between the housing cooling (5) and the fastening bracket (1). 5

2 Mounting 1 2 3 4 5 6 Fig. 2: Housing cooling with mounted sensor 1 Fastening bracket 2 Hexagon screw M8 (4 pieces) 3 Washer for M8 (4 pieces) 4 Isolating sleeve (4 pieces) 5 Housing cooling 6 Hexagon nut M8, self-locking (2 pcs.) Inserting the sensor 2. Place the fastening bracket (1) onto the housing cooling (5). Make sure that the cooling air connections point in a suitable direction. Rotating the fastening bracket later (1) is very difficult. 3. Connect the fastening bracket (1) with the housing cooling (5) according to the illustration and tighten the screws (2, 6) with a torque of 15 Nm (11.06 lbf ft). Provide counterforce with a second fork wrench. 1. Insert the sensor into the housing cooling. The small lid of the instrument housing must point to the front after mounting on the fastening bracket (x). 1 x 5 6 Fig. 3: Mounting direction of the sensor towards the fastening bracket 1 Fastening bracket 5 Housing cooling x Mounting direction of the housing

2 Mounting 2. It is advisable to place the sensor and the housing cooling on the floor while inserting. Protect the sensor by covering the sensor housing during mounting. Mount the sensor with the two screws (7) in the appropriate position. 1 7 8 9 4 Fig. 4: Mounting the sensor 1 Fastening bracket 4 Isolating sleeve (2 pieces) 7 Hexagon screw M8 (2 pieces) 8 Retaining washer for M8 (2 pieces) 9 Washer for M8 (4 pieces) Housing cooling Mounting the scintillator cooling Take note of the following general mounting instructions: First of all, mount the fastening bracket and the housing cooling, and then the sensor The small lid of the instrument housing must point to the front after mounting the fastening bracket (x) The sensor together with the air cooling system is very heavy. Use a suitable lifting device for mounting Mount the scintillator cooling according to the following assembly drawing: 7

2 Mounting 10 11 12 13 14 15 Fig. 5: Mounting scintillator cooling - upper part 10 Housing cooling 11 Holding flange (bisectional) 12 Hexagon screw (6 pieces) 13 Compression nut - top 14 Seal ring 15 Scintillator cooling hose (with connection thread) 8 1. Slide the upper compression nut (13) from below onto the black scintillator of the sensor. Make sure that the upper compression nut (13) has a fastening slot and that this slot points in the direction of the housing cooling (10). 2. Slide the seal ring (14) from below onto the scintillator cooling hose of the sensor. The seal ring (14) encircles the scintillator cooling hose very tightly and must be moved with a rolling motion over the entire length of the scintillator cooling hose. Make sure that the seal ring is not damaged or contaminated. 3. Push the upper compression nut (13) from below against the housing cooling (10). 4. Place the two half shells of the holding flange (11) from the side onto the upper compression nut (13) and fasten to the housing cooling (10) with the enclosed hexagon socket screws (12). The compression nut remains rotatable. 5. Grease the upper thread of the scintillator cooling hose (15) with acid-free grease, e.g. Fuchs Lubritech Gleitmo 155 (heat-resistant hot thread compound). This makes screwing the parts together easier. 6. Push the scintillator cooling hose (15) from below onto the scintillator of the sensor.

2 Mounting 7. Slide the upper seal ring (14) from below into the opening of the upper compression nut (13). Make sure that the seal ring (14) is clean and undamaged and not twisted during the process. 8. Slide the thread of the scintillator cooling hose (15) from below into the upper compression nut (13). Screw the scintillator cooling hose (15) slowly into the upper compression nut (13) up to the stop. Turn the compression nut (13) with the attached hook wrench. the scintillator cooling hose is contracted on its thread in direction of the housing cooling. Turn the upper compression nut (13) with the enclosed hook wrench up to the stop. 9. The upper part of the scintillator cooling is then sealed. Mount the lower part as follows: Fig. 6: Mounting scintillator cooling - lower part 14 Seal ring 15 Scintillator cooling hose (with connection thread) 16 Sensor (scintillator hose) 17 Compression nut - bottom 15 14 16 17 Tip: The length of the scintillator cooling hose is measured exactly. Nevertheless you may have the impression that the scintillator cooling hose is too long. Align the scintillator cooling hose in a straight line and make sure that the cooling hose is not bent. If necessary, the cooling hose can be pressed slightly in the length. Make sure that the black scintillator of the sensor protrudes slightly out of the scintillator cooling hose. 10. Grease the lower thread of the scintillator cooling hose (15) with acid-free grease. This makes screwing the parts together easier. 11. Slide a seal ring (14) from below onto the scintillator hose (16) of the sensor. Make sure that the seal ring (14) is not damaged or contaminated. 12. Slide the lower compression nut (17) from below onto the thread of the scintillator cooling hose (15). 13. Screw the lower compression nut (17) slowly onto the scintillator cooling hose (15) up to the stop. Apply counterforce on the fixed tube part of the scintillator cooling hose (15) with a strap wrench (oil filter wrench) and tighten the lower compression nut (17) with the enclosed hook wrench up to the stop. The scintillator cooling is now completely sealed. 9

2 Mounting Lifting the air cooling system Information: The sensor together with the air cooling system is very heavy. Use a suitable lifting device for mounting. Use a hoisting sling with sufficient loading capacity. Take note of the sling marking. You can find the respective weight of the air cooling system in chapter "Technical data". Place the lifting sling around the cooling tube directly below the flange. The loop is a so-called lark's foot. Fasten the hoisting sling according to the following illustration. Mounting the sensor 10 Fig. 7: Attaching the sling As soon as the air cooling system is mounted, you can install the sensor with the air cooling system in your facility.

2 Mounting You can mount the sensor on your vessel with the enclosed mounting clamps. A number of mounting clamps come with the air cooling system depending on the length of the sensor. Use a mounting clamp approx. every 450 mm (17.72 in). Adjust the distances between the attached mounting clips. Take note of the minimum bending radius of the housing cooling, which is 294 mm (11.57 in). 1. Determine the exact mounting position of one or several mounting clamps and mark the holes. You can find the drilling template in the technical data. Align the mounting positions exactly and average the distances between the enclosed mounting clamps. Drill appropriate holes (max. M12) for fastening the mounting clamps. Note: The mounting clamps do not come with fastening screws. Use fastening elements that are appropriate for the situation in your plant. 2. Position the base plate (35) and fasten it in the specified mounting position. 3. Fasten additional mounting clamps exactly aligned in the same way. 28 30 31 32 34 35 Fig. 8: Mounting clamps 28 Hexagon screw M6 x 100 30 Cover plate - metal 31 Upper clamping jaw 32 Fastening screws (provided by the customer) 34 Lower clamping jaw 35 Bottom plate - Metal 4. Place the lower clamping jaw (34) onto the bottom plate (35). 11

2 Mounting Mounting the housing cooling box 5. Insert the sensor with the cooling system into the lower clamping jaw (34) and align the cooling system. 6. Place the cover plate (30) onto the upper clamping jaw (31) and place the two parts onto the lower clamping jaw (34). 7. Insert the two hexagon screws (28) into the holes of the cover plate (30) and the upper clamping jaw (31) and then push the hexagon screws (28) through the two clamping jaws. 8. Tighten the two hexagon screws (28) with a torque of 8 Nm (5.9 lbf ft). You can find further information on sensor mounting in the operating instructions manual of the sensor. 1. Open the fasteners (36) and remove the lid (37) from the lower part of the housing cooling box (38). 2. To make mounting easier, screw the cable glands of the sensor out of the instrument housing. 3. Place the lower part of the housing cooling box (38) on the fastening bracket (1). 4. Insert the 6 hexagon socket screws (39) from below through the mounting bracket (1) and tighten the screws with a torque of 4.5 Nm (3.3 lbf ft). 36 37 41 41 38 39 40 12 Fig. 9: Mounting the housing cooling box 36 Fasteners with safety latch 37 Lid of the housing cooling box 38 Lower part of the housing cooling box 39 Spring ring for M5 (6 pieces) 40 Hexagon socket screw M5 x 14 (6 pieces) 41 Connection opening for vortex cooler (type FOS 208SS 25 HVE BSP)

2 Mounting Electrical connection 1. Open the fasteners (36) and remove the lid from the housing cooling box (37). 2. Determine which cable gland you need for connection of the sensor. 3. Pierce a small hole with a sharp tool (e.g. pricking awl, scriber, etc.) in the center through the respective rubber diaphragms (42). Do not use a knife or similar for puncturing If you have accidentally pierced the wrong diaphragm, you can simply exchange the rubber diaphragms. If you have pierced a diaphragm too much, you can seal it with self-adhesive fabric tape. 36 37 42 38 Fig. 10: Preparations for electrical connection 36 Fasteners with safety latch 37 Lid of the housing cooling box 38 Lower part of the housing cooling box 42 Rubber diaphragm 4. Insert the cable gland into the resulting opening and screw it tightly to the sensor housing. Make sure that the rubber diaphragm encircles the cable gland completely so that not too much cooling air can escape. 5. Connect the sensor to voltage supply. Keep in mind the information in the operating instructions of the corresponding sensor or in the wiring diagram on the housing lid. Note: The cooling system is used in areas with high temperatures. Therefore, use temperature-resistant cable and install it in such a way that contact with hot components is avoided. 6. From the front side, place the lid of the housing cooling box (37) onto the lower part of the housing cooling box (38). 13

2 Mounting 7. Close the two lateral fasteners (36). Make sure that the fasteners (36) are provided with safety latches against unintentional opening. To open a fastener, you have to press the safety latch. Connect cooling The scintillator cooling and the housing cooling box must be connected to the cooling system. Cooling systems (vortex cooler) So-called Vortex coolers are proven possibilities for cooling the sensor. You can connect the cooling air output of the vortex cooler directly to the housing cooling box or scintillator cooling. The two vortex coolers are part of the scope of delivery. The coolers thus fit perfectly to your air cooling system with respect to size, cooling capacity and throughput. Z X Y 14 Fig. 11: Eddy current cooler (Vortex cooler) x Hot exhaust air y Supply air z Cooling air Caution: The vortex cooler gets very hot during operation. Hot air at approx. 100 C (212 F) escapes from the exhaust opening. Furthermore, the cooler or sensor can be very cold on the cold air side. Wear suitable protective clothing and prevent people from touching the cooling system by installing barriers, etc. Make sure that the exhaust airstream can escape safely into the open. Make sure that no heat-sensitive components or cables are in the exhaust airstream. If you want to direct the exhaust airstream in another direction, you have to use standard, angled metal fittings with ¼" screw connection.

2 Mounting 1. The housing cooling box has two connection openings with ¼" connection. Close the free openings with a respective bling plug. 2. The two lateral opening on the housing cooling have no function. Close the openings with the attached blind plugs to avoid penetration of dirt and moisture. 3. Connect the vortex coolers. The vortex cooler type FOS 208SS 25 HVE BSP powers the housing cooling box. The vortex cooler type FOS 208SS 35 HVE BSP is connected to the scintillator cooling. Screw in the short cooling air output of the vortex cooler and tighten it with a torque of 25 Nm (18.43 lbf ft). c c d a b Fig. 12: Connection of the cooling air systems (vortex coolers) a Cooling air inlet - scintillator cooling (vortex cooler type FOS 208SS 35 HVE BSP) b Cooling air outlet - scintillator cooling c Cooling air inlet - Housing cooling box (vortex cooler type FOS 208SS 25 HVE BSP) Connection on the left or right possible For cooling, use clean, water-free compressed air of class 3:3:2 acc. to ISO 8573-1:2010. Make sure that your compressor has enough supply capacity. You can find information on quality, pressure, 15

2 Mounting throughput and temperature of the cooling air in chapter "Technical data". Make sure that the cooling air inlets do not freeze, e.g. in case of a shutdown. Caution: Do not loosen any screws or connections during operation and make sure that the cooling air supply is reliable and interruption-free. Plan the necessary steps for a possible compressed air failure. We recommend installing a temperature sensor (in the housing cooling box) that triggers an alarm when a critical temperature is reached. If you want to use the air cooling in an SIL-qualified application, you have to assess the SIL failure rates of the complete air cooling system and the cooling air supply yourself. Install a protective grid Take note of the operating instructions manuals of the corresponding radiation-based sensors and the source holder. When handling radioactive substances, unnecessary radiation exposure must be avoided. If there are gaps or intervening spaces after mounting, provide protective fences or grids to keep hands away from the dangerous area. Such areas must be marked accordingly. Install a safety barrier on both sides of the cooling system. A sheet metal cover or an appropriately shaped plastic sheet can also be used. 16

3 Replacement parts 3 Replacement parts Air cooling - vortex coolers 3.1 Available spare parts - air cooling Selected components of the cooling are available as replacement parts. The following parts are available: The stated quantity is the quantity delivered. 1 7 5 2 6 5 4 3 Fig. 13: Spare parts - air cooling with vortex cooler 1 Rubber diaphragm (2 pcs.) 2 Lid of the housing cooling box 3 Threaded adapter ¼ NPT (1 pce.) 4 Distance threaded adapter for vortex cooler ¼ NPT (1 pce.) 5 Threaded adapter for vortex cooler ¼ NPT (1 pce.) 6 Vortex cooler type FOS 208SS 35 HVE BSP (input for cooling air - scintillator cooling) 7 Vortex cooler type FOS 208SS 25 HVE BSP (input for cooling air - housing cooling box) 17

4 Supplement 4 Supplement 4.1 Technical data General data Take note of the information in the operating instructions manual of the installed FIBERTRAC 31 level sensor and the source holder Material 316L corresponds to 1.4404 or 1.4435 Materials Housing cooling 316L Housing cooling box 316L Metal fabric hose of the scintillator Stainless steel cooling Seal NBR Application temperature See in the following "Throughput - Coolant air" Weight Housing cooling 2.3 kg (5.1 lbs) Scintillator cooling 8.8 kg/m (1.62 oz/in) Housing cooling box 3.2 kg (7.1 lbs) Fastening bracket 4.8 kg (10.6 lbs) Fastening clamp 0.48 kg (1.06 lbs) Total length of the air cooling system max. 7 m (275.6 in) Torques Screws - Sensor mounting (M8) 15 Nm (11.06 lbf ft) Nuts - housing cooling (M8) 15 Nm (11.06 lbf ft) Hexagon socket screws - holding 4.5 Nm (3.3 lbf ft) flange (M6) Threaded fittings - vortex coolers 25 Nm (18.43 lbf ft) Screws for mounting clamps 8 Nm (5.9 lbf ft) Connection thread of the cooling air inputs ¼" DIN ISO 228 (adapters for NPT fittings are enclosed with respective version) Throughput - Coolant air Quality of the compressed air ISO 8573-1:2010 [3:3:2] Supply capacity - Compressor 1) Type FOS 208SS 25 HVE BSP 708 L/min (25 SCFM) Type FOS 208SS 35 HVE BSP 991 L/min (35 SCFM) Air pressure of the supply air 5 7.9 bar (72 114 psig) Temperature of the supply air < +20 25 C (+68 77 F) Ambient temperature Sensor length 0.3 5 m (1 16.4 in) +80 C (+176 F) Sensor length 5 7 m (16.4 23 in) +70 C (+158 F) 1) at 6.9 bar (100 psig) 18

4 Supplement Approvals If you use an air cooling system in hazardous areas, make sure that the max. permissible temperatures in the Ex safety instructions are maintained around the sensor. If this is ensured, the sensor can also be used with an air cooling system in hazardous areas. 19

4 Supplement 4.2 Dimensions Active air cooling system 254,6 mm (10.02") 126,6 mm (4.98") 273 mm (10.75") 192 mm (7.56") 38 mm (1.50") 211 mm (8.31") 51 mm (2.01") 63,5 mm (2.50") 14 mm (0.55") 127 mm (5.00") 152,5 mm (6.00") G 1/4 20 mm (0.79") 111,5 mm (4.39") ø 141,3 mm (5.56") 82 mm (3.23") 82 mm (3.23") ø 64 mm (2.52") 150 mm (5.91") L 30 mm (1.18") 136 mm (5.35") L1 L1 R 294 mm (11.57") 1 G 1/4 20 1

4 Supplement Fig. 14: Active air cooling system with scintillator cooling and housing cooling box 1 Position of the lower measuring range end (on the upper edge of the lower compression nut) L Total length of the air cooling system L1 Distance between the mounting clips = approx. 450 mm (17.72 in) 21

Notes 22

Notes 23

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2017 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com