Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 1 of 3 HONGGE (GUANGZHOU) PAPER CO., LTD BUILDING 1, HE TAI INDUSTRY ZONE, HE TAI ROAD NO.2, HE BIAN, JIA HE TOWN, BAI YUN DISTRICT, GUANGZHOU. CHINA The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description : PAPER DISPLAY SHELF Style / Item No. : HGDS002 Manufacturer : HONGGE (GUANGZHOU) PAPER CO., LTD Sample Receiving Date : May 21, 2012 Test Performing Date : May 21, 2012 to Jun.08, 2012 Test Result Summary No. Test(s) Requested Result(s) Comments Partial tests of BS 48757: 2006 Strength and 1 stability of furniture Domestic and contract storage furnitureperformance requirements PASS / (Level 1) 2 Maximum load on shelf (As per client s request) 90kg / 3 EN 135011:2007+A1:2009 Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests, class E. PASS / For further details, please refer to the following page(s) Signed for and on behalf of SGSCSTC Co., Ltd. Jack Yao Approved signatory
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 2 of 3 1. Test Conducted: Partial tests of BS 48757: 2006 Strength and stability of furniture Domestic and contract storage furnitureperformance requirements (Level 1) Test Items Test Methods & Requirements Test Results Static load test for tops and bottoms Clause 6.2.2) Strength of shelf supports Clause 6.1.4) Deflection of shelves Clause 6.1.3) Test for structure and underframe Clause 6.4.1) Apply a vertical downwards force of 600 N 10 times at any position likely to cause failure but not less than 50 mm from the edges. Load the shelf uniformly with half the load specified for 6.1.3, except at 220 mm from one support, where the impact plate shall be tipped over 10 times over the support. All supports of the shelf shall be tested. Load the shelf uniformly with the load of 1.0kg/dm² and apply for: one hour for shelves made of metal, glass and stone; one week for all other shelves. measure and record the deflection under load Load all parts intended for storage. Close extension elements, flaps, rollfronts and doors. Apply the static force of 150 N 10 times at point A on the centre line of the side of the unit as high as possible but not higher than 1600mm from the floor. Repeat this procedure 10 times at points B, C and D, with the legs or base still restrained by stops. Remark: 1. N/A Not applicable; 2. Only partial tests of BS 48757:2006, which were requested by applicant, were performed. 3. Sample details Overall dimensions 896mm(L) 450mm(W) 1680mm(H) Weight 15.34 kg Photo Appendix N/A PASS PASS PASS Sample as received View 1 Sample as received View 2
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 3 of 3 2. Maximum load on shelf Apply a gradually increasing force at the center of the shelf at rate Maximum load on shelf of 100mm per minute until it is damaged. The maximum force during application shall be read. Photo Appendix: 90 kg (See picture) maximum load Test 3. I. Test conducted This test is conducted as per EN 135011:2007+A1:2009 Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests. And the test methods as following: EN ISO 119252:2002 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Part 2: Singleflame source test. II. Details of classified product Description The details of the tested specimen given below have been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. Name Color Thickness Paper display shelf Yellow About 26.5 mm III. Test results EN ISO 119252:2002 Singleflame source test Exposure conditions: Surface exposure and Edge exposure Flame application time: 15s
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 4 of 3 (1) Surface exposure Expression of results Lengthwise Specimen No. & Result Crosswise 1 2 3 4 5 6 Whether ignition occurs (Yes/No) Whether the flame tip reaches 150 mm above the flame application point, and the time at which this occurs (No/Time) Whether ignition of the filter paper occurs (Yes/No) Observations of physical behaviour (2) Edge exposure Expression of results No Ignited No Ignited No Ignited No Ignited No Ignited No Ignited Lengthwise Specimen No. & Result Crosswise 1 2 3 4 5 6 Whether ignition occurs (Yes/No) Whether the flame tip reaches 150 mm above the flame application point, and the time at which this occurs (No/Time) Whether ignition of the filter paper occurs (Yes/No) Observations of physical behaviour IV. Classification and direct field of application No Ignited No Ignited No Ignited No Ignited No Ignited No Ignited This classification has been carried out in accordance with EN 135011:2007+A1:2009. The product, Paper display shelf, comply the requirements of Reaction to fire classification: E Remark: The classes with their corresponding fire performance are given in annex A. Statement: The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. Warning: This classification report does not represent type approval or certification of the product.
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 5 of 3 The test laboratory has, therefore, play no part in sampling the product for the test, although it holds appropriate references to the manufacturer s factory production control that is aimed to be relevant to the samples tested and that will provide for their traceability. Annex A Classes of reaction to fire performance for construction products excluding floorings and linear pipe thermal insulation products Class Test method(s) Classification criteria Additional classification A1 A2 B C EN ISO 1182 a EN ISO 1716 EN ISO 1182 a or EN ISO 1716 EN 13823 EN 13823 Exposure =30s EN 13823 Exposure=30s and and and T 30, and m 50%, and t f =0(i.e. no sustained flaming) PCS 2.0MJ/kg a and PCS 2.0MJ/kg b c and PCS 1.4MJ/m 2 d and PCS 2.0MJ/kg e T 50, and m 50%, and t 20 s f and PCS 3.0MJ/kg a and PCS 4.0MJ/m 2 b and PCS 4.0MJ/m 2 d and PCS 3.0MJ/kg e FIGRA 120W/s and LFS<edge of specimen and THR 600s 7.5MJ FIGRA 120W/s and LFS<edge of specimen and THR 600s 7.5MJ Fs 150mm within 60 s FIGRA 250W/s and LFS<edge of specimen and THR 600s 15MJ Fs 150mm within 60 s D E F EN 13823 and FIGRA 750W/s Exposure=30s Exposure =15s No performance determined Fs 150mm within 60 s Fs 150mm within 20 s flaming droplets/particles h
Test Report No.: SDHGR120501002FM Date: Jun.08, 2012 Page 6 of 3 a For homogeneous products and substantial components of nonhomogeneous products. b For any external nonsubstantial component of nonhomogeneous products. c Alternatively, any external nonsubstantial component having a PCS 2,0 MJ/m 2, provided that the product satisfies the following criteria of EN 13823: FIGRA 20 W/s, and LFS < edge of specimen, and THR 600s 4,0 MJ, and s1, and d0. d For any internal nonsubstantial component of nonhomogeneous products. e For the product as a whole. f In the last phase of the development of the test procedure, modifications of the smoke measurement system have been introduced, the effect of which needs further investigation. This may result in a modification of the limit values and/or parameters for the evaluation of the smoke production. s1 = SMOGRA 30m 2 /s 2 and TSP 600s 50m 2 ; s2 = SMOGRA 180m 2 /s 2 and TSP 600s 200m 2 ; s3 = not s1 or s2 g d0 = No flaming droplets/ particles in EN 13823 within 600 s; d1 = no flaming droplets/ particles persisting longer than 10 s in EN 13823 within 600 s; d2 = not d0 or d1. Ignition of the paper in EN ISO 119252 results in a d2 classification. h Pass = no ignition of the paper (no classification); Fail = ignition of the paper (d2 classification). i Under conditions of surface flame attack and, if appropriate to the end use application of the product, edge flame attack. Photo Appendix: ***End of Report***