Progressive distributor MX-F

Similar documents
Progressive distributor SXE-2

Progressive distributor SX-1

Progressive Central Lubrication Systems

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet...

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

Hydraulic pump HP-1. Type 1. Type 2

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve)

EUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim

Hydraulic Pump. General description. Hydraulic circuit diagram

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

Flow limiter SP/SMB 8... DSK US (09.04)

Central lubrication pump PICO

Piston Distributors, Metering Units

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems

Electric Pump EP-1. Electric pump EP-1 with steel reservoir and pump element PE-120 V with manometer:

AUTHORIZED DISTRIBUTOR DPX PROGRESSIVE DIVIDERS

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

Kerosene - oil burner

GREASE NLGI (*) OIL CST (*) PRESSURE (220.5) (147) - 20 (294) (220.5)

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB

PROGRESSIVE BLOCK DISTRIBUTOR BVA-N

PROGRESSIVE DISTRIBUTOR PRA,PRB

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-B

LUBRICATION SYSTEMS PRELIMINARY WE MEASURE OUR SUCCESS BY YOUR UP-TIME SINCE 1927

Motor-driven pump unit GSJB

Single-Line Centralized Lubrication Systems

Flow limiter SP/SMB3 Flow limiter SP/SMB6

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-C

Sisu S-Cam Drum Brakes

Grease-lubricating pump FF... DSK US (05.05)

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

15000 TT Series Tube Type

Oil - kerosene burner

Injection oilers, micro pumps for minimal quantity metering

1.1 EP-1 PUMP WITHOUT TIMER

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D

The PReMIeRe of The year

DPL. Monoblock progressive dividers. High quality and High tolerance Unbeatable combination of performance and convenience

ORDER ON-LINE /

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return

Hydraulic Clamping Systems

Progressive Central Lubrication System

Injection oilers, micro pumps

QUICKLUB. Owner Manual Technical Description. LINCOLN GmbH Postfach 1263 D Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) Tx

OPTIONS AUTOMATIC LUBRICATION SYSTEM

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

PARTS LIST FOR NO. 1 SERIES 1AM ANGLE TOOLS 17 (SERIAL B )

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

ECO Plus 2 - The new generation of the proven BPW ECO Unit

COMPACT UNIVERSAL SLIDES

PICO-tronic Integrated Electronic Control Systems

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type electronically controlled

Flow Monitors and Sensors

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES

TriboTec LUBRICATION PUMP VEG

Accessories, spare parts and measuring equipment

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

DPL MONOBLOCK PROGRESSIVE DIVIDERS

Operation and service manual

BC Spare parts list. Bucket crusher. BC 2500 s/n DEQ Construction Tools GmbH No

Support legs. Installation and operating instructions

Light oil - kerosene burner

BASIC MANUAL X30 125CC MAN-80

LIGHTWEIGHT AND COMPACT. SERIES SL Nm. single-position multi-position. THE ultimate COUPLING from Nm

Forward and Reversing Vibrating Plate LH 300/700. Work Shop Manual WLHALLEN1, October 2001

Flow limiter SP/SMB10 Dual flow series

MONOBLOCK TYPE PROGRESSIVE DISTRIBUTOR INSTRUCTION AND USER MANUAL

HB 3600, 3600 DP. Spare parts list. Hydraulic breakers. HB 3600 s/n DEQ HB 3600 DP s/n DEQ

HB 2500, HB 2500 DP. Spare parts list. Hydraulic breakers. HB 2500 DP s/n DEQ Construction Tools GmbH No

Accessories smart additions for efficiency and intelligent performance

Parts and Accessories Installation Instructions

Pull out clutch E snap ring and withdraw complete clutch pack of clutch E. 6 HP 26 ZF Getriebe GmbH Saarbrücken CD

HB 2000, HB 2000 DP. Spare parts list. Hydraulic breakers. HB 2000 s/n DEQ HB 2000 DP s/n DEQ

-H- Note. Feed separators HPV Key features at a glance. Separation of workpieces in the supply process

Metso High Consistency Sampler Metso Nove H. Installation & Owner s Manual K10196 V1.1 EN

HB 2000, HB 2000 DP. Spare parts list. Hydraulic breakers. HB 2000 s/n DEQ HB 2000 DP s/n DEQ

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

TOE 80 TURRET USE AND MAIN TECHNICAL GUIDE

Special lubrication systems

SPARE PARTS CATALOGUE SELF-LOADING BALE WRAPPER Z-577 Sokół. Sokółka 20...

X30 125cc Spec. EU ASSEMBLY INSTRUCTIONS AND USER MANUAL MAN-089

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

Single- and Multicircuit Pumps

TORQLIGHT SAFETY COUPLINGS

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

SIKA Flow Switches -1-

Injection Oilers, Micro Pumps

Pneumatic Rotary Actuator Type 3278

geodyna 2600/2800/2800p

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

Transcription:

The progressive piston distributors are distributor devices with a hydraulic sequence control, the pistons of which are regulated by the supplied lubricant in a way that the lubricant inevitably and successively escapes at the individual outlets. In the case of malfunction during the flow of lubricant, e. g. clogging of lubricating line or lubricating points, the distributor will block up. This blockage is used for the monitoring of the distributors. In the case of manually operated pumps a virtually insurmountable counter pressure occurs during the blockage. In the case of automatic pumps such as e. g. the electropump EP- the lubricant escapes at the excess pressure valve. The progressive distributors are manufactured in a variable disk construction, which offers the advantage that the distributor can be extended or shortened at random according to the amount of lubrication points. Due to this disk construction there is also the possibility of constructing an overall progressive distributor from individual distributor disks with different outputs per piston stroke. The difference in output per piston stroke is achieved by different piston diameters. To ensure the proper functioning of a progressive distributor a minimum of three pistons, i. e. a minimum of three output elements is required. Progressive distributor MX-F with four output elements and eight outlets: 7 Dimension drawing: A 0..7.. PU000EN Technical data: Operating pressure - Inlet: max. 00 bar Temperature range: - C to +80 C Carrier vehicle: Oil - viscous oil - grease Number of elements: Min. MX-F / ( piston elements) Max.: MX-F / ( piston elements) Element designation MX-F MX-F MX-F 7 MX-F 0 Outlets Dimension A Dimension B Delivery quantity per outlet per element mm³ mm³ 7 mm³ 0 mm³ 9. 7. 9. 7. 0 mm³ 90 mm³ 0 mm³ 0 mm³ 9. 7. 8 8.9 7.0 Piston dia. mm mm mm mm 0 98.7 8.7. 0. 8.. 0 Ø. 7.9 7. B 8 7.7.7 0 7. 0. 87. 7.. M0x Inlet for dia. mm 0.9 90 X Outlet for dia. mm

Functional description of standard distributor The progressive distributor individually consist of an initial element (without piston), min. middle elements and a possible element 00 and one end element that are connected by connecting rods (hexagon screws) and toothed lock washers until you receive distributor blocks. The progressive distributors consist of the individual components inlet element IE (without piston), middle element ME and end element EE, all of which are assembled in distributor blocks using tension rods (hexagon socket screws) with lock washers. The individual elements are sealed with O-rings. The lubricant flows via the inlet of the distributor through all distributor disks to the piston (I) (illustration A). The piston (I) is shifted to the left and the lubricant is pressed from the left pressure range of the delivery piston to the outlet (illustration B). After that, the proportioning pistons (II) and (III) are progressively shifted and the lubricant is primed to the outlets and. After the piston (III) has been shifted, the lubricant is directed to the left side of the delivery piston (I) (illustration C) and primed from the right pressure range of the delivery piston to the outlet. Subsequently, the delivery pistons (II) and (III) are shifted and lubricant is pressed to the outlets and. Illustration A III II I Pressure range Illustration B: III II I After the delivery piston (III) has been shifted, the lubricant is once more directed to the right side of the delivery piston (illustration A) and a new cycle of the progressive piston distributor is initiated. The described function is repeated as long as lubricant is fed to the progressive distributor. Illustration C: III II I

Functional description of distributor with element 00 When using a element 00 the distributor mainly operates like a standard distributor. Figure D: III Lubricant flows via the distributor inlet through all distributor discs to the piston (I). During this process the non-return valve RV in the dummy element opens (fig. D, red marking). The piston (I) is moved to the left and lubricant is pressed out of the left chamber to outlet (fig. D, blue marking). RV 00 RV II I Druckraum Afterwards the piston (II) is moved and lubricant is delivered to outlet (fig. E, blue marking). Figure E: III RV 00 II I Druckraum RV

Functional description of distributor with element 00 Now lubricant flows to piston (III). This is moved to the left (fig. F, red marking). Lubricant is pressed out of the left chamber, moves the piston (00) of the dummy element (fig. F, blue marking) and initiates a signal at the proximity switch when this is installed on the left side of the distributor. The non-return valve RV of the dummy element opens and lubricant is supplied to outlet (fig. F, green marking). Figure F: III RV 00 RV II I Right after the piston (III) has been moved, lubricant is supplied to the left side of the piston (I) and moves it to the right (fig. G, red marking). Lubricant from the right pressure chamber of the piston (I) is supplied to outlet (fig. G, blue marking). Pressure chamber Figure G: III RV 00 II I RV Druckraum

Functional description of distributor with element 00 Now the piston (II) is moved to the right (fig. H, red marking) and lubricant is supplied to outlet (fig. H, blue marking). Figure H: III RV 00 RV II I Before piston (III) is moved to the right, the piston (00) of the element 00 is also moved to the right (fig. I, red marking) so that the proximity switch can initiate a new signal. Figure I: III Pressure chamber RV 00 II I RV Pressure chamber

Functional description of distributor with element 00 When piston (III) has been moved the non-return valve RV opens and lubricant flows towards piston (III) and moves it to the right (fig. J, red marking). The metering quantity from the right pressure chamber of the piston (III) is then supplied to outlet (fig. J, blue marking). As soon as piston (III) is moved, lubricant is lead to the left side of the piston (I) and the distributor cycle starts anew (see fig. D). Figure J: III RV 00 RV II I Pressure chamber

Assembling outlets: For larger lubrication points the assembly of two or more outlets at the progressive distributor may be required. The individual disks of the progressive distributor have two outlets. outlets per distributor element (standard type) -fold Sealing screw SW When assembling two outlets at the progressive distributor the two outlets of one disk are connected. To achieve this, the sealing screw separating the two sides is removed and a lock screw screwed in to the side, which is to be closed. The output of the closed side is now escaping on the other side, i. e. the output of the open side is doubled. outlet per distributor element -fold Lock screw SW Lock screws are generally required for the assembly of outlets: Lock screw for progressive distributor MX-F: Order-no: 00 9000000 To separate assembled outlets on progressive distributors the sealing screw must ne screwed back in: Sealing screw for separation of outlets on progressive distributors MX-F: Order-no: 080000 7

Assembling several outlets Assembling outlets with a pipe or distributor bridge without outlet: If the total output of the outlets assembled in one disk of the progressive distributor is not sufficient, e. g. in the case of large bearing points or main distributors, there is the possibility of assembling the outlets of several distributor disks. To achieve this, tow distributor disks are connected with a pipe or distributor bridge as described here. Depending on which element the sealing screw separating the two sides of a distributor disk is removed from, in this way three outlets are connected. Subsequently, the output of the closed outlets escaped at one outlet. The dosage is calculated on the basis of the output value of all assembled piston sides. A pipe bridge or a distributor bridge can also be used for the assembly of four outlets. To achieve this, the sealing screw must be removed from both distributor disks and one of the two outlets must be closed off opposite the pipe bridge or distributor bridge with a lock screw. assembled outlets -fold -fold assembled outlets -fold Pipe bridge: Cap screw ÜS M0x Order-no: 080000 and Double cone olive DKR Order-no: 090800 and Reducer ring dia. to dia. Order-no: 0800000 Order-no collective: 00 900 00 Pipe bridge Order-no: F009/-00 00 8

Assembling several outlets Distributor bridge without outlet: a) Distributor bridge without non-teturn valve:,9 Comprising: 9,7 Order-no: 00 900 00 0 piece link unit Order-no: F009/-00 piece hollow bolt without outlet Order-no: 080 000 piece sealing ring A0x,x, () Order-no: 09 070 0 piece sealing ring A0xx () Order-no: 09 070 09 b) Distributor bridge with integrated non-return valve: Example: To ensure the proper working order of a progressive distributor with three delivery elements but only two outlets with integrated check valve must be used (see example on the right). 0* 0 0* 0,9 Comprising: 9,7 Order-no: 00 900 00,9 0 piece link unit Order-no: F009/-00 piece hollow bolt without outlet () Order-no: F009/-00 piece hollow bolt with non-return valve () Order-no: 00 900 007 piece sealing ring A0x,x, () Order-no: 090700 piece sealing ring A0xx () Order-no: 0907009 9

Assembling of and more outlets Assembling outlets with distributor bridges with outlet: For the connection of two outlets (on different adjacent distributor disks) the sealing screw may not be removed from either of the two concerned distributor disks. As a result, the output of both the outlets escapes at the outlet of the distributor bridge. outlets per distributor element -fold -fold -fold For the connection of three outlets the sealing screw must be removed from one of the two concerned distributor disks. A lock screw must be fastened in the free outlet of this distributor disk. As a result, the output of all three outlets escapes at the outlet of the distributor bridge. outlets per distributor element -fold -fold For the connection of four outlets the sealing screw must be removed from both distributor disks and a lock screw must be screwed into the outlets situated opposite the distributor bridge. As a result, the output of all four outlets escapes at the outlet of the distributor bridge. outlets per distributor element -fold Distributor bridge with outlet: Comprising: 9.7 Order-no: 00 900 00 SW.9.9 0 Piece link unit Order-no: F009/-00 Piece hollow bolt with outlet Order-no: F009/-00 Piece hollow bolt without outlet Order-no: 080 000 Piece sealing ring A 0 x. x. () Order-no: 09 070 0 Piece sealing ring A 0 x x () Order-no: 09 070 09 0

Input screw connections The MX-F progressive distributor can be used both as a main distributor and secondary distributor. When used as a main distributor, the pump is connected by means of a high-pressure hose. Also when used as a secondary distributor, the connection from the main distributor generally requires a high-pressure hose. This hose must be connected by means of a insert and a treaded ferrule. The connection diameter of the insert can be dia. or dia. 8. All screw connections with M0xk threads or M0x threads and a sealing edge can be used for the input connection of the MX-F progressive distributor. Angular coupling: Dimension diagram: S S Three different couplings are available with the above pipe diameters. A) Angular coupling: L Pipe-dia. D Order-no: WELL M0xk 00000 WE8LL M0xk 0000 G L L Pipe-dia. D 8 M M0xk M0xk L 8 8 L.. approx. L 8 S S B) Straight coupling: Straight coupling: Order-no: GELL M0xk 000000 GE8LL M0xk 00000 Pipe-dia. D 8 M M0xk M0xk L L 8. 8. approx. L 8 S S Dimension diagram: G L L S L S Pipe-dia. D

Input screw connections C) Swivel angular coupling: Swivel angular coupling: Order-no: WSLL M0x WS8LL M0x 00000LL 0000LL Pipe-dia. D 8 M M0x M0x L 0. L 9. 0 appox. L L 0 i S S S D Dimension diagram: S S S i L L Pipe-dia. D M D L L

Screw fittings for outlet Screw connections: Polyamide pipe with a diameter x. or steel pipe with a diameter x is generally screwed to the distributor with a cap screw US M0x and a double cone olive DKR. The connecting sleeve used for connecting to the highpressure hose can also be fastened directly to the distributor with the cap screw US M0x and the corresponding double cone olive. The polyamide pipe dia. x0.8 hard or the steel pipe dia. x0.7 is connected to the distributor with a reducer from dia. to dia., a double cone olive DKR and a cap screw US M0x. Cap screw US M0x Order-no: 08000090 Double cone olive DKR Cap screw US M0x Order-no: 080000 Double cone olive DKR Order-no: 090800 Order-no: 090800 Reducer ring at dia. to dia. Order-no: 0800000 Polyamide pipe screwed onto a distributor disk MX-F: Polyamide pipe dia. x. Reducer ring at dia. to dia. Polyamide pipe dia. x0.8 hard Plug connections: Cap screw Cap screw US M0x Double cone olive US M0x DKR Double cone olive DKR Straight pin-and-socket connector for MX-F distributor: The polyamide pipe dia. and polyamide pipe dia. hard can also be connected to the distributor by means of a plug connection. For this purpose, straight pin-and-socket connectors for the MX-F distributor are screwed into the distributors outlets. These straight pin-and-socket connectors are available for pipe dia. and for pipe dia.. The turned conical form on the front eliminates the need for an additional double conical ring. To connect a high-pressure hose to a plug-and-socket connector, use a pipe socket for plug-and-socket connections (ref. no: 00 9) with groove. In this case, the pipe connection dia. is dia.. Pipe dia. D mm mm Order-No FAZ00-0 FAZ00-00 M0x SW. 7. Pipe dia. D

Screw fittings for outlets Non-return valve for progressive distributors MX-F The non-return valves are generally used in connection with the high-pressure hose, e. g. for lubrication points with increased back pressure or in main distributors. Non-return valve for progressive distributors MX-F for main distributors: Cap screw 7. SW Two types of non-return valves are available at which the pipe socket is screwed up and furthermore two types with plug connectors. M0x M0x The polyamide tube and high-pressure hose are screwed onto the non-return valve of the progressive distributor MX- F with a cap screw and a double cone olive. Non-return valves with cap nut and cutting olive require no additional union piece. Order-no: 00 900 0000 Double cone olive Non-return valve with cap nut and cutting olive for auxiliary distributors: SW approx.. M0x Pipe dia.. Order-no: 08 000 79 Cap nut and cutting olive The high-pressure hose can be plugged in at the non-return valve with BEKAconnector. Pipe dia. D SW A Order-no. Non-return valve with BEKA-plug-in connector 8. 0 009000007 009000008 Dia. d M0x The plug connection at the non-return valve with connector model HP is a detachable one. SW A SW Non-return valve with plug-in connector model HP: SW Dia., Dia.. M0x Order-no..: 0090000

Elements Progressive distributors MX-F consist of one initial element (without delivery piston), two to eleven middle elements and one end element each. Inital elements Initial elements are available with or without inlet union piece. All union pieces with a threaded connection of M0x can be screwed into an initial element without inlet union piece. Initial element without inlet union piece: Order-no: 00 9 00 Initial element with angular coupling WE M0xk: Order-no: 00 9 00 Middle elements are available with four different outputs. Middle element for progressive distributor MX-F: MX-F = mm³/stroke MX-F = mm³/stroke MX-F 7 = 7 mm³/stroke MX-F 0 = 0 mm³/stroke Elements 00 Additionally to the middle elements, a element 00 can be installed in the progressive distributor MX-F. The proximity switch is installed at this element. Elements 00 contain a signal piston. The metering of the lubricant is not possible with a element 00. Proximity switches that are installed at the distributors monitor the system or in regards to the stroke control, count the piston strokes of the distributor. Element 00 for progressive distributor MX-F with proximity switch Mx: The proximity switch can be installed right or left. Please indicate this when ordering (see table on right side). The middle element 00 can be installed at any position of the distributor, also if the distributor was already in use. A middle or end element MX-F 7 or MX-F 0 must follow a middle element 00. Description MX-F MX-F MX-F 7 MX-F 0 MX-F 00 MX-F 00 Proximity switch without without without without Mx right Mx left Order-no 00 9 0 00 9 0 00 9 0 00 9 0 00 9 00 00 9 000

Elements The proximity switch is delivered with a welded cable of 0, m.another cable can be installed at this cable. This must be ordered seperate (see page 7). Installation dimensions: Mx Technical data of proximit switch: Connection: poles / Mx plugable Switch type: DC PNP NO contact Current load: 00 ma Current consumption: < ma Voltage: 0-0 V DC perm. ambient temperature: - C to +70 C perm. operating pressure: max. 0 bar for grease Protection class: IP 7 0, m SW Ø, 0 0,,7 0, Functional description The piston () of the element 00 is moved by the flowing lubricant. This flows towards the proximity switch () and initiates a signal. This signals can be processed differently depending on the control type of type of use. Sectional drawing: SW 0 SW 0 br sw bl + 0 to 0 V DC Input control or SPS - Ground End element for progressive distributor MX-F: End elements are also available with four different outputs (see table). End elements can be delivered with an installed lubrication nipple. By means of the lubrication nipple also the progressive distributor MX-F can be lubricated manual. Conical form grease nipple M0xk Order-No.: 0970 Description MX-F MX-F MX-F 7 MX-F 0 MX-F MX-F MX-F 7 MX-F 0 Form grease nipple without without without without with with with with Order-No. 00 9 0 00 9 0 00 9 0 00 9 0 00 9 0 08 00 9 0 08 00 9 0 08 00 9 0 08

Plug and cable for proximity switch Elements 00 are delivered with an already welded cable, length 0, m. Various sockets with different cable lengths are available. They must be ordered separately. Connection cable no for connection to external control units or for connection to a control with a Hirschmann plug: For connecting the proximity switch to external control units or for connection to a control with a Hirschmann plug, connection cables no with straight sockets Mx for the proximity switch are available in lengths of m, m and 0 m. The connecting diagrams can be found in the description of the respective control unit. For the connection to the integrated controls BEKA-troniX and EP-tronic with bayonet connector, a connection cable no with lengths of m and m is available, with a straight socket Mx on one end for the proximity switch and a straight or angular plug Mx on the other end for connecting to the control unit. The connection cables can also be combined. In order to connect existing proximity switches with M8x connecting threads to the integrated controls BEKA-troniX and EP-tronic with bayonet connector, an adapter is available with a straight socket M8x for the proximity switch and a straight plug Mx. The plug and socket are connected by a cable with a length of 0 cm. This adapter can be used to connect a connection cable no and no. If a proximity switch Mx must be connected to an existing system via a cable for a proximity switch M8x, e. g. if the proximity switch had to be replaced previously, an adapter cable of 0 cm length with a straight socket Mx for the proximity switch and a straight plug M8x for connection to the existing cable can be ordered. Socket Mx for connecting to the proximity switch Cable length m m 0 m Order-no 000 9 8 000 9 7 000 9 7 Connection cable no for connection to the integrated controls BEKA-troniX and EP-tronic with bayonet connectors: Straight plug Mx for connecting to the integrated control units BEKA-troniX and EP-tronic with bayonet connector Socket Mx for connecting to the proximity switch Plug Mx for connecting to the connecting cable no and no Socket M8x for connecting to the proximity switch Order-no: 000 9 9 Socket Mx for connecting to the proximity switch Plug M8x for connecting to the connecting cable of the existing device Order-no: 000 9 9 Angular plug Mx for connecting to the integrated control units BEKA-troniX and EP-tronic with bayonet connector Cable length m m m m Plug type straight straight angular angular Order-no 000 9 000 9 000 9 7 000 9 8 Socket Mx for connecting to the proximity switch 7

Elements with optical stroke pin control or control pin indication Elements of progressive distributor MX-F can also be fitted with an optical stroke pin control. This functional test element does not supply any electrical data. However, a distributor can be upgraded any time with an optical stroke pin control by removing the piston lock screw () and screwing in the optical stroke pin control (). This is only possible for the middle or end elements MX-F 7 and MX-F 0. Warning: This process must be carried out paying attention to utmost cleanness. Functional description: The plunger () is shifted towards the outside (in the example shown to the right) when the piston () is operated and the control pin () becomes visible. Control pin and plunger are moved back into their starting position by the spring (), as soon as the piston is shifted to the other side by the grease (see functional description for MX-F distributors on page ). Order-no for optical stroke pin control: 0 00 0 MX-F distributor and optical stroke pin control: Optical stroke pin control attached to the disk of a progressive distributor: Installation dimensions: 8 SW Contrary to the optical stroke pin control the control pin indication cannot be subsequently installed and it can only be installed in the middle elements MX-F 7 and MX-F 0 as well as in end elements MX-F 7 and MX-F 0. The installation must be indicated when ordering. Progressive distributors can be upgraded with a control pin indication by exchanging the respective distributor disk.. MX-F distributor with attached control pin indication (primed): Functional description: In the case of control pin indication the plunger (7) is directly connected with the piston of the progressive distributor (8). At every stroke the plunger (7) is forcibly extracted or retracted. Output Name per outlet Middle element 7 mm³ MX-F 7 Middle element 0 mm³ MX-F 0 End element 7 mm³ MX-F 7 End element 0 mm³ MX-F 0 Outlet dia. mm mm mm mm Order-no 009 009 009 009 Element of a progressive distributor MX-F with a attached control pin indication: Installation dimensions: 8. 7 SW 0 8

Elements with pressure indicator The outlets or the distributor inlet of the progressive distributor MX-F can be equipped with a pressure indicator, i. e. excess pressure is optically indicated. This display element does not supply any electronic data. The pressure indicator can be upgraded at any time, as it is simply screwed into the distributor outlets between the distributor element and the cap screw or into the distributor inlet between the screw connection and the initial element of the progressive distributor. Pressure indicator attached to an MX-F distributor Screwed into the distributor inlet: Pressure indicator (not primed) Screwed into the distributor outlet: Pressure indicator (primed) Warning: This process must be carried out paying attention to utmost cleanness! Functional description: In case of excess pressure the pin () is primed and the bolt () is visibly lifted against the spring force. In the case of decompression the spring () presses the bolt () and the pin () back into the starting position. Pressure indicators can be ordered for different pressure ranges (see table). The pressure range is set by the spring (). Functional description: Order-no: Pressure (bar) Color Pressure indicator according to FAZ009-00 0 silver 0 00 0 00 0 0 red 0 00 0 00 0 70 white 0 00 0 00 0 00 yellow 0 00 0 00 0 0 black 0 00 0 00 0 00 green 0 00 0 00 0 0 blue 0 00 07 00 0 Installation dimension: R/8 k. M0x 0 M0x 9

Extension or shortening of distributors Due to the disk construction of the progressive distributors MX-F they can be adapted to different operating conditions at any time. If lubrication areas need to be added or become unnecessary, the distributor can be extended or shortened by addition or removal of distributor disks. Description: Remove the tension rods (), which hold the distributor together Separate the distributor at the required place Add or remove the respective distributor disks Screw the distributor together with the respective tension rods and one toothed disk each (see table) Warning: Utmost cleanness is essential for this work. Note: An MX-F distributor must always consist of a minimum of three and a maximum of outlet elements. MX-F distributor /7, to which three distributor disks should be added: Tooth lock washer Order-no: 09 0797 00 MX-F distributor, view from above: If one of the O-rings used for the sealing of the distributor between the individual elements is damaged and the sealing is no longer sufficient a set of O-rings can be ordered containing all O-rings fitted in MX-F distributors. Sealing set for initial elements: Order-no: 00900000 Sealing set for middle elements: Order-no: 00900000 Warning: When mounting the distributors back in, it must be ensured that the pistons of the distributors are in a horizontal position. The mounting area must be level and obstruction-free. To facilitate the drilling of the mounting holes for the distributor a drilling template is available, Order-no: 00 900 0000. Table of tension rods: Dimension of Dimension of distributor tension rod Order-no MX-F / M x 0 09 09 09 MX-F /8 M x 09 09 0 MX-F /0 M x 80 09 09 0 MX-F / M x 9 09 09 0 MX-F 7/ M x 0 09 09 08 MX-F 8/ M x 09 009 08 MX-F 9/8 M x 0 09 009 00 MX-F 0/0 M x 09 009 0 MX-F / M x 70 09 009 MX-F / M x 8 09 009 Mounting position of the distributors: Correct: Incorrect: 0

Ordering key Distributor input: The progressive distributor MX-F is available with three different types of input connections or without connection at the distributor input. The screw connection type must be indicated before the diameter when ordering: M0x without screw connecting (in this case the indication of diameter is not necessary ) WE for angular coupling GE for straight coupling WS for swivel angular coupling If no coupling type is indicated, then an angular coupling dia. will be delivered. Distributor outlet: The distributor outlet is available with cap screws, plug-in connections and two types of non-return valves. The screw connection type must be indicated before the diameter when ordering: M0x without screw connecting (in this case the indication of diameter is not necessary ) US for cap screws GS for plug-in connections RVAfor non-return valves with DKR and US RVB for non-return valves with SR and UM If no screw connection type is indicated, cap screws dia. or in case of installation of a proximity switch a RVB0 will be delivered. Sample order: Position of outlets Outlet Outlet locked R Inlet 7* 7* 7* Pipe-dia. Lock screws and outlets sealed by distributor bridges are indicated by a dash (-). For distributor bridges, the sealing screw to be removed must be indicated by an asterisk (*). Elements 00 must be marked with NS00 on the installation side of the proximity switch. The indication of the metering quantity is not necessary as there is no metering of dummy elements. The sealed outlet on the opposite side of the proximity switch must be marked with a dash (-). L Pipe bridge Pipe-dia. Outlet Output elements * = Sealing screw removed! Dosing quantities: The dosing quantities must be indicated on each side of the distributor inlet in the direction of the distributor end. The dosing quantities are indicated with the names on page. For combined outlets, the dosing quantities names are added (see page ). For the installation of distributor bridges or a pipe bridge, a plus (+) has to be indicated instead of the slash. Type Number of output elements Number of outlets Tube diameter inlet Tube diameter outlets Position of connections Dosing quantities R 00* / -* / -*NS00 MX-F / - WE / RVB L - + - / 0 X