Zero Leakage Isolation Damper

Similar documents
Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Flamgard Calidair Dampers. High integrity dampers engineered for total safety

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

VOLUME CONTROL / REGULATING DAMPERS

INDEX. Chapter1 6. air master. Volume Control Dampers

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Actionair Control and Shut Off Dampers

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

FSD60/MFSD60 Multi-blade Fire Damper

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Motorized Fire Dampers

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

CONTROL SMOKE AND BALANCING DAMPERS

HCD-230 Industrial Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

ARROW UNITED INDUSTRIES

For installation into ductwork

Marine Fire and Gas Dampers

SMOKE DAMPER - CLASS F MODEL BMSD

Technical information

ARROW INDUSTRIAL PRODUCTS

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Linear Slot Diffusers Model Slot 20 & Model Slot 25

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

AL-Maraj Central A/C Systems Accessories Mfg Co.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Introduction to Johnson Controls Dampers

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

A Complete Line of Quality Products for Marine Applications

AMD-33 Air Measuring Station with VCD-33 Control Damper

Laboratory Exhaust Air Terminal

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

CFSD Series. Product Description

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Type NAK. Gas-tight shut-off damper with pneumatic actuator

VARYCONTROL VAV Dual Duct Terminal Boxes

VCD-23. Flange Options. Size Limitations

POWERS Controls No. 4 Pneumatic Damper Actuator

VOLUME CONTROL DAMPERS

When Time is Everything... We Manufacture in Days - Not Weeks!

Multileaf damper with actuator

MOTORIZED VOLUME DAMPER

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

L O U V E R S & D A M P E R S

series FSD-FLD Fire and smoke dampers UL Approval

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

FlowBar High Capacity Slot Diffuser

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

CCS Zone/Bypass Damper Assembly

Laboratory Exhaust Air Terminal

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

VOLUME CONTROL DAMPER

INDEX. Chapter2. air master. Grilles and Registers

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

XeteX, Inc. All Rights Reserved.

Fan - Powered Terminal Unit Series Flow

ID-141x 12-Gauge Hat Channel Industrial Damper

BD-1600 Balancing/Zone Control Damper

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

SECTION AXIAL HVAC FANS

Catalogue. FlowBar. High Capacity Slot Diffuser.

SINGLE DUCT TERMINAL UNITS

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

MO Declutchable Manual Override Gearbox EL-O-Matic F-Series Actuators option

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

Variable Air Volume Dampers

Smoke Dampers. Installation Instructions

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Non Return Damper, Type RK-E20

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

LLOYD INDUSTRIES INC.

RETROFIT TERMINAL UNITS

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Transcription:

SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot adaptors are used which increase the damper insertion length from 350 to 450 mm. The blades are a formed single-skin of 3.0 mm sheet steel fitted with a closed cell pad that seals against a frame within the damper casing to provide 100% isolation. Continuous shafts Ø 19.05 mm with welded pivoted-blade support at each end. Parallel action linkage consisting of drive levers and bosses connected by flat bar link bars, driven through stainless steel pins. All linkage is contained within the depth of the casing. Phosphor bronze self lubricated plain Oilite bushes fitted Into bearing bosses welded to the outside of the casing. DESCRIPTION The type CID-01 Isolation Damper has been specifically designed to meet the tight shut-off requirements of the industrial and nuclear markets, where isolation of ducting for filter replacement or duct inspection is required, without shutting down complete systems. These versatile dampers can be automatically or manually operated and can be supplied with pre-drilled flanges to ease installation. The dampers may be installed vertically or horizontally with the air flow in one direction. 350 Zero Leakage Isolation Damper Lipseal type fitted into each bearing boss. End Elevation Duct Width Pneumatic Actuator. Electric Actuator. Manual Handwheel. Earth continuity bosses. Lifting lugs. Solenoid Valves. Remote Indication - Microswitches. Local Indication. Duct Height 130 Other variations to suit clients specific requirements are also available. Extension Elevation Page 30

Zero Leakage Isolation Damper INSTALLATION AND ASSEMBLY Leakage: Each damper is tested to ensure there is zero leakage Through the blades and casing - as follows:- Test Procedure: Each complete damper assembly is subjected to a works pressure test of 5000 Pa for one hour. The upstream en of the damper is sealed during the test and the pressurizing source removed. After one hour the pressure is checked to ensure that it has not dropped taking into consideration any changes in air temperature. Typical Installation 100 Blanking Plate Pressure Guage TEST ARRANGEMENT OPEN PRESSURE DROP CHARACTERISTIC CURVE Tolerance ±15% Digital Thermometer Manometer Isolating Valve 80 Multiple Assemblies Top Hood 150mm deep ΔP N/m² 60 40 Central Hood 150mm deep horizontal member 20 Max. module size 1000mm x 1000mm 0 5 10 15 20 25 Max. multiple assembly 2100mm x 2150mm Face Velocity m/sec. (Based on duct area) Page 31 Mullion 100mm wide vertical member Standard depth 350mm

SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot adaptors are used which increase the damper insertion length from 350 to 450 mm. Maximum duct size is : - 600 mm Wide x 300 mm High The blade is a formed single-skin of 1.5 mm sheet steel and seals against a flame retardant PVC strip attached to the blades and top and bottom stops. Continuous shafts Ø 9.5 mm. Phosphor bronze self lubricated Oilite bushes with lipseals to eliminate casing leakage. Pneumatic Actuator Electric Actuator Hand Locking Quadrant Materials can be stainless steel, galvanized mild steel or other materials to suit the clients specific requiremen Earth continuity bosses. Lifting lugs. Flame retardant PVC blade seals. Integral or removable enclosures for housing control equipment. High temperature bearings. DESCRIPTION The type CID-02 Isolation Damper has been designed to give maximum efficiency under arduous conditions and is suitable for fitting with the air flow in one direction only. The dampers may be installed vertically or horizontally. This damper will give 100% shut-off when airflow aids closure of blade. 70 Duct Height 350 Direction Of airflow Duct Width End Elevation Single Blade Isolation Damper Other variations to suit clients specific requirements are also available. Elevation Page 32

Single Blade Isolation Damper INSTALLATION AND ASSEMBLY Leakage: Each damper is tested to ensure there is 100% sealing Through the blades and casing - as follows:- Test Procedure: Each compete damper assembly is subjected to a works pressure test of 5000 /m² for 10 minutes. The upstream end of the damper is sealed during the test and the pressurizing source removed. After 10 minutes the pressure is checked to ensure that it has not dropped. OPEN PRESSURE DROP CHARACTERISTICS The design of this damper is virtually free of obstructions making the pressure drop over the damper so small there are no instruments capable of measuring the value. If 100% free area is required, simply increase the duct size by 20 mm width and height to eliminate the area occupied by the blade sealing stops. The damper flanges can be adjusted to accommodate the difference. Blanking Plate Manometer Isolating Valve Pressure Gauge TEST ARRANGEMENT Page 33

WARNING ACTIVE MECHANISM THIS COVER MUST ONLY BE PERSONNEL. REMOVED BY AUTHORISED SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Damper units in excess of 1275 mm width shall be manufactured as a multiple assembly. Where circular dampers or dampers with width or height dimensions less than 150 mm are required, additional spigot adaptors are used which increase the damper insertion length from 300 to 400 mm. The blades are a formed double-skin aerofoil section of 1.5 mm sheet metal with stainless steel edge seals. Blade stops at the top and bottom of the casing and sprung side seals provide excellent low leakage characteristics. Continuous Ø 19.05 mm with blades plug welded at each end. Parallel action linkage consisting of drive levers and bosses connected by flat bar link bars, driven through stainless steel pins. All linkage is contained within the depth of the damper casing. DESCRIPTION The type CRD-01 Gas Retention Damper has been specifically designed to meet the rigorous duty required in an environment where robust construction and dependable operation are of prime importance. These versatile dampers are suitable for automatic and manual operation and are used for retaining the release of an inert gas extinguisher during a high temperature event. To ease installation all dampers are supplied with pre-drilled flanges and are designed to be suitable for mounting in any attitude with the airflow in either direction. 300 Gas Retention Damper Phosphor bronze self lubricated Oilite flanged bushes. Pneumatic Actuator. Electric Actuator. Manual Latching Mechanism. Linkage End Elevation Duct Width Materials can be stainless steel, galvanized mild steel or other materials to suit the clients specific requiremen Earth continuity bosses. Lifting lugs. Integral or removable enclosures for housing control equipment. High temperature bearings. Shaft seals to provide airtight casings Other variations to suit clients specific requirements are also available. Duct Height Elevation Page 34

Gas Retention Damper INSTALLATION AND ASSEMBLY Note: Larger dampers can be constructed by joining multiple assemblies together. An approved fire-resistant sealant should be inserted between the damper and duct to ensure a good seal. Note: Each section shall have a drive spindle which can be linked together externally or driven independently. Typical Insulation Leakage m³/sec 0.07 0.06 0.05 0.04 0.03 0.02 0.01 LEAKAGE CHARACTERISTIC CURVE Tolerance ±15% 1000 x 1000 600 x 600 0 500 1000 1500 2000 2500 Static Pressure N/m² 300 x 300 OPEN PRESSURE DROP CHARACTERISTIC CURVE Multiple Assemblies 100 Tolerance ±15% Transom 50mm wide horizontal member ΔP N/m² 80 60 40 20 Page 35 Mullion 50mm wide vertical member Max. module size 1275mm x 1800mm Max. multiple assembly 3925mm x 3650mm Standard depth 300mm 0 5 10 15 20 25 Face Velocity m/sec. (Based on duct area)