CONTROL SMOKE AND BALANCING DAMPERS

Size: px
Start display at page:

Download "CONTROL SMOKE AND BALANCING DAMPERS"

Transcription

1 (UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed, semi-sealed, or fully sealed option Flanged, spigotted, sleeve or wall mounting Manual or motorised (electric or pneumatic) Airfoil blade option-10 Series A p p r o v a l s Quality Assurance system assessed to BS EN ISO 9002 Shock tested to DEF standard 0- Conformance to DW 142 as appropriate

2 INTROION The Universal range of control dampers is designed to balance and/or control air flow through ducts, walls and floors, and may also be used to restrict the spread of smoke through a building. The range incorporates features required by specifiers, contractors and fire authorities, and embodies the combined experience of Nailor Industries Inc. (Canada and United States of America) and (UK) Limited, in design, manufacture, sales and service of dampers. QUALITY ASSURANCE dampers are manufactured in accordance with a Quality Assurance system assessed to BS EN ISO The company is registered to this standard with BSI (Certificate No. FM 114) and with the Loss Prevention Certification Board (Certificate No. 128). DESCRIPTION The Universal range is robustly constructed in all galvanised steel, with options of stainless steel blades, or stainless steel blades and casing (4 Grade). There are models suitable for low, medium and high pressure applications, with a variety of sealing options. Dampers are supplied with flanged, spigotted, wall or sleeve mounting, and either manual or motorised (electric or pneumatic) control is available, as required. Standard blade format is the aerodynamically designed ribbed blade (00 Series), with an airfoil blade option (10 Series). Whatever your application, s Sales Office would be pleased to advise on the most suitable model from the Universal range. 1 MODEL RANGE 31 1 X X 1 INTERNAL WIDTH / HEIGHT = SPIGOTTED 0 WIDTH / HEIGHT / DIA. + MM WIDTH / HEIGHT / DIA. - 4 MM 11-11/2/3 0 ØOR 0 X 0 11 ØOR 11 X 1-11/2/3 0 ØOR 0 X 0 11 ØOR 11 X 1 Spigots may be circular (1), or flat oval (2), or square/rectangular (3). PAGE 2

3 1 1 0 X X 0 INTERNAL WIDTH / HEIGHT = 2 WALL/FLANGE SLEEVE WIDTH / HEIGHT - 3 MM X 1 1 X 1 For full details of product coding, see back page. Airfoil Blade versions of all types (except fully sealed) are available, designated 10 Series. Side linkage only. (Model Refs. 1111, 11, 1141 etc.). SYSTEM PRESSURE Standard products are suitable for use up to Pa. On request, 00 Series units can be strengthened to allow use up to 00 Pa or Pa. Maximum velocity recommended - m/s. NOTES 1. The drive spindle position varies dependent on duct height and the number of blades - full details are available from our Sales Office. Drive spindle is 1 /2 " diameter. 2. Drive spindles and controls are normally located on the right hand side of the damper casing, as viewed in the direction of the arrow in the above drawings. 3. For sizes greater than the maximum size shown, multi-module construction can be supplied. For details of the number and location of actuators for multiple sections, contact the Sales Office. 4. Within the maximum and minimum stated dimensions, increments of 2mm in height are preferred.. Dependent on model and duct height, the blades in sleeved and flanged models may protrude, when in the open position, by up to 2mm on each side. Full details are available from the Sales Office. A deep case option, to avoid any protrusion, is available. SMOKE CONTROL For application as a smoke damper, the use of a model with parallel blades, side seals and oilite bearings is recommended. Note that the drive spindle comes through the casing direct from the drive blade - the 00 Series is therefore not suitable as a smoke damper when the damper is to be built into a wall or partition. In this case, consider the 10 Series Smoke and Fire dampers. PAGE 3

4 P RO F EATURES MANUAL OPERATION HAND LOCKING QUADRANT OPEN 3 / 4 ELECTRICAL MICRO-SWITCH to provide remote indication of whether the blades are open or closed. The micro-switch may also be connected to any warning device or controls circuit. 1 / 4 SHUT ELECTRICAL ACTUATORS MODELS AVAILABLE INCLUDE On/Off On/Spring return Off Modulating PNEUMATIC ACTUATION is also available 2 POLE - 1 NORMALLY CLOSED + 1 NORMALLY OPEN SNAP ACTION SUITABLE FOR UP TO 240V, 3A. For full details of Actuator options, please contact the Sales Office SEALS STANDARD UNIT is supplied without side seals, sills or blade seals. SEMI-SEALED unit includes stainless steel side jamb seals and sills. FULLY SEALED unit also includes UPVC blade seals, to maximum operating temperature of 80 o C. Higher temperature seals are available - please contact the Sales Office. BEARING SIDE SEAL (WHERE REQUESTED) BEARINGS Selcon bearings are fitted as standard - maximum operating temperature is 80 o C. FRAME BLADE OPTIONS AVAILABLE ARE: - Oilite bearings - normal maximum operating temperature is 0 o C, with a high temperature version operating up to 0 o C. - Stainless steel bearings, with maximum operating temperature of either 400 o C or 6 o C, as specified. BLADE SEAL (WHERE REQUESTED) PAGE 4

5 W EIGHT C HART ADVANCED AIR - 00/10 SERIES - NETT WEIGHTS All weights are approximate and in kilograms NOTES 1. Weights stated are for non-spigotted models. 2. Spigotted + %. 3. Extra weight has to be added for drive options - if required. NOMINAL DAMPER SIZE (MM) 0 0 WIDTH (MM) HEIGHT (MM) TORQUE CHART 00 Series control dampers - torque to open (Nm). VELOCITY M/S 0 X X X 900 PARALLEL OPPOSED PARALLEL OPPOSED PARALLEL OPPOSED The above results were determined by experimentation on side linkage dampers with side jamb seals. The tests were performed in a clean air system at 00 Pa corrected pressure and are for guidance only. No Side Seals multiply by.9 Side Seals and Blade Seals multiply x 1.1 For Multi-section (joined) units multiply by a further 1.2 PAGE

6 P ERFORMANCE DATA PRESSURE DROP - FULLY OPEN STATIC PRESSURE (PA) PRESSURE DROP (PA) VELOCITY (M/S) BLADE LEAKAGE FULLY SEALED 600 x x 900 Damper with sills, side seals and blade seals This graph is for standard units (no sills or seals) For units with sills and side seals ADD % For units with airfoil blades SUBTRACT % SEMI-SEALED Damper with sills, and side seals PAGE 6 AVERAGE LEAKAGE (M 3 /HR/M 2 )

7 TYPICAL ORDER DETAIL 11- SIZE ()MM QUANTITY FEATURES 0 X 0 OILITE BEARINGS TO SUIT MOTOR PRO CODING 1 PRO GROUP 2 MODEL 3 OPERATION 4 SEALS CONNECTION 6 (a) (d) MATERIAL.RIBBED BLADE 11.AIRFOIL BLADE 0. BASE 1. PARALLEL SLEEVE 2. OPPOSED SLEEVE 3. PARALLEL 4. OPPOSED. PARALLEL WALL 6. OPPOSED WALL 0. FACE (RHS) NON STD. 1. SIDE (RHS) 2. FACE (LHS) NON STD. 3. SIDE (LHS) 4. FACE (BOTH) NON STD.. SIDE (BOTH) 0. FULLY 1. NONE 2. SEMI S/S SIDE SEALS + SILLS 0. BASE 1. CIRCULAR SPIGOT 2. FLAT OVAL SPIGOT 3. RECT SPIGOT CASE (b) DEPTH. 0 CASE (b) DEPTH 0. GALV 1. 4 GRADE S/S BLADES GALV CASING 2. 4 (c) GRADE S/S BLADES & CASING. 4 (c) GRADE S/S BLADES & CASING FACE & BRKTS NOTES (a) Casing = frame or frame and case where relevant. (b) Applies to flanged models only. (c) Some components on these models are made from galv. mild steel. (d) 4 Grade stainless steel is not suitable for hostile or corrosive environments. ASSOCIATED PROS Other fully tested and approved product groups available include: SERIES 00/00 - CURTAIN FIRE DAMPERS SERIES 10 - FIRE/SMOKE/CONTROL DAMPERS SERIES SLIMLINE BALANCE AND CONTROL DAMPERS SERIES - LEAKAGE RATED FIRE/SMOKE DAMPERS SERIES INSULATED FIRE/SMOKE DAMPERS SERIES FIRE RATED DIFFUSER ASSEMBLIES SERIES ACCESS DOORS SMOKE MANAGEMENT SYSTEMS The information contained in this publication is correct at the time of printing. Continuous product development means that from time to time product specifications and other information will change. The company therefore reserves the right to modify or withdraw any of the products described without prior notice MEMBER (UK) Limited Cavendish Road Bury St Edmunds Suffolk IP33 3TE England Tel Fax sales@advancedair.co.uk DESIGNED AND PRODUCED BY EXPOGRAPHICS LTD TEL:

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V41706 VC Series Volume Control Dampers Roll formed steel blades with three material options DW144 compliant Flanged models with 65mm deep mechanically fixed casings Rectangular spigotted models with 85mm

More information

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume

More information

Actionair Control and Shut Off Dampers

Actionair Control and Shut Off Dampers December 2003 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Actionair Control and Shut Off Dampers Air/Shield Aerofoil Air Control Dampers Air/Shield Aeroseal Air Control and Shut-Off Dampers Energy/Shield

More information

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options. Duct Regulating Dampers Two blade options. DW144 compliant Four case options Three control options Nylon bushes as standard Suitable for vertical and horizontal ducted systems. M A N U F A C T U R E R

More information

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Blade Features. AirShield Control and Shut Off Dampers. AirShield April 2011 AirShield AirShield AirShield Aerofoil Air Control Dampers AirShield Aeroseal Air Control and Shut Off Dampers AirShield Features and Design Guide Opposed blade dampers suitable for systems

More information

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.

More information

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V11711 D Series ackdraught Volume Regulating Damper Extruded aluminium blades DW144 compliant Galvanised mild steel casing with stainless steel option Flange or spigot casing options Infinite sizing capability

More information

VOLUME CONTROL / REGULATING DAMPERS

VOLUME CONTROL / REGULATING DAMPERS VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot

More information

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400 SERIES 400 Series 900 Volume Control And Shut Off Dampers: Series 900 balancing and shut off dampers have been designed, engineered and tested, with smooth efficient operation as an important consideration.

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide Louvre systems Incorporating Series WL Standard range of single bank louvres as used in countless installations worldwide Good resistance to water ingress, with low resistance to airflow Approximately

More information

MOTORIZED VOLUME DAMPER

MOTORIZED VOLUME DAMPER MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

Cell Ventilation Security Grille

Cell Ventilation Security Grille June 2010 Cell Ventilation Security Grille Cell Ventilation Security Grille Model CV Features Stainless Steel Construction Galvanised Steel/ PPC Construction Supply and Exhaust Tested "Fit For Purpose"

More information

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N V1175 FD-C Series Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper ES classified fire dampers with reduced smoke leakage characteristics (BS E 1366-2) Aerodynamically

More information

Catalogue. FlowBar. High Capacity Slot Diffuser.

Catalogue. FlowBar. High Capacity Slot Diffuser. Catalogue FlowBar High Capacity Slot Diffuser www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... 4 Diffuser Specification... 5 Air Patterns... 6 Flange Styles... 7 Curved Sections...

More information

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions. Fire & Gas Introduction Fire & Gas are used in ventilation systems to prevent the spread of flame and/or smoke between divisions. Authority/Certification Wozair manufacture three types of Fire & Gas Damper

More information

SERIES GP. Security Grilles

SERIES GP. Security Grilles PUBLICATION GRILLES 10 JUNE 16 Features - Robust 2mm Thick Stainless Steel Fascia. - Available for Air Supply, Air Extract or Air Transfer Applications. - High Security Rear Bolt Fixings. - Screwdriver

More information

SERIES GP GILBERTS. Security Grilles. Features

SERIES GP GILBERTS. Security Grilles. Features Security Grilles PUBLICATION GRILLES 10 NOV 10 Features Robust 2mm Thick Stainless Steel Fascia. Available for Air Supply, Air Extract or Air Transfer Applications. High Security Rear Bolt Fixings. Screwdriver

More information

MULTI-BLADE FIRE DAMPERS

MULTI-BLADE FIRE DAMPERS MODL D1201-DOW (1 1/2 HR.) OUT OF WALL DYNAMIC FIR DAMPR AIRFOIL BLAD DUCTD BOTH SIDS D1201-DOW is an "out of wall" (vertical mount) or "out of floor" (horizontal mount) high performance dynamic fire damper

More information

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating

More information

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects March 06 A-60 Marine Fire Dampers Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information

INDEX. Chapter1 6. air master. Volume Control Dampers

INDEX. Chapter1 6. air master. Volume Control Dampers Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard

More information

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING VAV/CAV BOXES COMMERCIAL BUILDINGS A guide to VAV/CAV, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk At Price TWA we believe

More information

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum

More information

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006 FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. AUGUST 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Stainless Steel Side Seals. Constant Tension Stainless Steel

More information

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf

More information

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. FEBRUARY 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Optional Stainless Steel Side Seals. Constant Tension Stainless

More information

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise EYELASH DIFFUSERS E SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 71526 - Fax: 01707 71 527 - email sales@jprservices.co.uk

More information

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type ) ( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS LINEAR SLOT DIFFUSERS MODEL CD Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk - www.jprservices.co.uk

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

VOLUME CONTROL DAMPERS

VOLUME CONTROL DAMPERS VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

MULTI-BLADE FIRE DAMPERS

MULTI-BLADE FIRE DAMPERS MULTI-BLAD FIR DAMPRS MODLS 1201-MDG & 1201-MDS MULTI-BLAD MARIN FIR DAMPRS AIRFOIL BLAD LOW LAKAG Model Series 1201-MDG and 1201-MDS are Multi-Blade Low Leakage Fire Dampers for use in marine applications

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

LINEAR SLOT DUFFUSERS

LINEAR SLOT DUFFUSERS LINEAR SLOT DUFFUSERS CE SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL 2AA Tel: 010 12 - Fax: 010 1 2 - email sales@jprservices.co.uk

More information

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame

More information

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide. Louvre systems Incorporating Series WL Standard range of single bank louvres as used in countless installations worldwide. Good resistance to water ingress, with low resistance to airflow. Approximately

More information

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers. TransShield Mode 1/2 Transfer Stainless Steel Sliding Plate Fire Dampers www.actionair.co.uk sales@actionair.co.uk Introduction The TransShield Modes 1 and 2 stainless steels stainless steel sliding plate

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

HIGH CAPACITY LINEAR SLOT DUFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871

More information

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR) UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555 & UL555S. Meets NFPA 90A and SMACNA requirements for fire &

More information

Smoke Dampers. Installation Instructions

Smoke Dampers. Installation Instructions Smoke Dampers Installation Instructions Installation Details 1. Dampers should be installed to provide proper operation and performance. They should be installed to permit them to maintain their shape

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers Incorporating V2.0 Product spec >>> > Series DJ - Drum jet diffusers Diffusers Drum jets (Premium) Recommended for: Wall, ceiling & duct Supply Overview Exceptional throw Throw completely adjustable Drum

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

A Complete Line of Quality Products for Marine Applications

A Complete Line of Quality Products for Marine Applications american warming and ventilating A Mestek Company A Complete Line of Quality Products for Marine Applications 1 About AWV Marine Dampers At American Warming and Ventilating, we are committed to design

More information

SFD-EN Smoke/Fire Dampers

SFD-EN Smoke/Fire Dampers December 2009 SFD-EN SFD-EN Smoke/Fire Dampers Features Proportional Torque Control for optimised torque performance. Unique snaplock drive interface ensures user friendly connection of Control Actuator

More information

CURTAIN TYPE FIRE DAMPER

CURTAIN TYPE FIRE DAMPER MODEL: IBD-2 / IBD-2H STANDARD CONSTRUCTION FIRE RATING UL 555 1-1/2 hours UL classification damper SS: 4 hours rating classification damper NOTES Damper s dimension is usually about 10 mm smaller than

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

L O U V E R S & D A M P E R S

L O U V E R S & D A M P E R S L O U V E R S & D A M P E R S www.alggin.com CALGARY EDMONTON LETHBRIDGE 4540-46th Ave. SE 12110-154 St. NW 1126-36 St. N (403) 252-0132 (780) 424-0132 (403) 320-8732 sales@alggin.com edmsales@alggin.com

More information

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension Adjustable Curved Vane Diffusers ACDH ACDV Vanes are parallel to the width dimension Vanes are parallel to the height dimension Diffusers 2 Adjustable Curved Vane Diffusers ACDH / ACDV Introduction The

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options. Includes new casing depths and thickness, Atex rated motor and visual indication options. Features Blades 430 stainless steel and 316 stainless steel options. Casings Lightweight cost effective design.

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options. January 2008 A-60 Marine Fire Dampers Includes new casing depths and thickness, Atex rated motor and visual indication options. NEW A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore

More information

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles Incorporating V2.0 Product spec >>> > Series DD - Double deflection grilles Grilles Double deflection Recommended for: Wall, ceiling & duct Supply & extract Overview Enhanced functionality As per the name,

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación > Rejas para instalación en intemperie > Rejas para instalación a intemperie > Type WG-JZ Type WG-JZ COMBINATION WITH A MULTILEAF

More information

SMOKE DAMPER - CLASS F MODEL BMSD

SMOKE DAMPER - CLASS F MODEL BMSD UL CLASSIFIED DAMPERS SMOKE DAMPER - BMSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555S. Meets NFPA 90A and SMACNA requirements for fire & smoke dampers. Application:

More information

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman

More information

ID-141x 12-Gauge Hat Channel Industrial Damper

ID-141x 12-Gauge Hat Channel Industrial Damper ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products

More information

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel

More information

SERIES GF. Heavy Duty Floor Grilles

SERIES GF. Heavy Duty Floor Grilles SERIES GF Heavy Duty Floor Grilles PUBLICATION GRILLES 15 MARCH 2015 Features - Numerous Frame Formats to Suit Floor Types of all Manufacturers - Robust Design. - Strong and Rigid Assembly. - Fully Tested

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information