Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Similar documents
Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Protector Selection Guide

NC1V. Circuit Breakers

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Circuit Protectors CP31F, 32F, 33F

Selection Guide. Control Circuit and Load Protection

Thermal Overcurrent Circuit Breaker 3120-F...

G-Series. Circuit Breaker.

RU Series Universal Relays

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal Overcurrent Circuit Breaker 3120-F...

ø8 A8 Series Miniature Control Units

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

PD-Series Ground Fault Circuit Protection

Magnetic and Hydraulic-Magnetic Circuit Breaker

UP Series Miniature Pilot Lights

Magnetic Overcurrent Circuit Breaker

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

Model Number Structure

ø10 A1 Series Miniature Control Units

Thermal Overcurrent Circuit Breaker 3120-F...

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

1492-CB 1492-GH 1492-GS

Thermal Overcurrent Circuit Breaker 3120-F...

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Thermal-Magnetic Circuit Breaker M1-...

HEAVY DUTY POWER RELAYS FEATURES

Magnetic and Hydraulic-Magnetic Circuit Breaker

PS6R 480W Switching Power Supply

HS1E Series Full Size Interlock Switch with Locking Solenoid

1 Form A 5A small size power relay for interface

GT5P Series ON Delay Timers

HS1E Series Full Size Solenoid Locking Switches

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Electronic circuit breaker EBU10-T

HS5E Miniature Interlock Switches with Solenoid

Only 21.5mm depth behind panel with LED Full Face, Illumination.

Thermal Overcurrent Circuit Breaker 3120-F...

6mm and 14mm Slim Interface Relay

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Thermal Circuit Breaker 3120-F...

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

General Specifications

Door Interlock Switches

HS1L Interlock Switches with Solenoid

Control Circuit Protection

MW Series Control Units

PB-Series. GFCI/ELCI & Panel Seal

ø12 A2 Series Miniature Control Units

2c 15A, 4c 10A polarized power relays

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

F-Series General Specifications

HS1C Interlock Switches with Solenoid

PS5R-S. Switching Power Supplies

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Solenoid Locking Safety Switches

HS1C-P Interlock Plug Unit with Door Lock

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

209 Series. Magnetic Circuit Protectors

General Specifications

Catalog Issued 3-03 (PDF Rev )

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Ktec Contactors and thermal overloads

QF(19) - Series Miniature Circuit Breakers

Relays & Sockets. RQ Series PCB Relays

Solenoid Locking Safety Switches

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

Miniature Switches & Pilot Devices

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

General Specifications

HL (AZH) LIMIT SWITCHES

General Specifications

35 35A 50 50A 1 Single phase. Solid state power controller

Thermal Overcurrent Circuit Breaker 3130

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Door Interlock Switches

Relays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Thermal Circuit Breaker / Switch Series 3131

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Switching Power Supplies

Thermal Circuit Breaker / Switch Series 3131

Switching Power Supplies

PDR circuit breaker - Ground fault Datasheet

6mm Interface Relays RV8 Series

SAR & SAS Circuit Protectors

SNAPAK Series Magnetic Circuit Protectors

F-Series. Circuit Breaker

HS5E Miniature Interlock Switches with Solenoid

Transcription:

Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers

Selection Guide ircuit Breakers Switches & Pilot Lights Selection Guide Series 1V RA RBM R Signaling Lights Appearance Terminal Blocks ontactors Timers Relays & Sockets Page 923 Actuator Style Lever umber of Poles 1, 2, 3 Lever and Rocker (non-illuminated and illuminated) Lever: 1, 2, 3 Rocker: 1 Protection Method Hydraulic magnetic Electromagnetic trip Internal ircuits Auxiliary ontact Alarm ontact Inertial Delay Series current trip Relay voltage trip Optional 125V A 3A (resistive load), 30V D 2A (resistive load) Optional 125V A 3A (resistive load). 30V D 2A (resistive load) Optional (for resistance to high inrush currents) Lever Slide switch, lever 1, 2, 3 1, 2 Series current trip Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (for resistance to high inrush) Optional (for resistance to high inrush) Time Delay urves 3 types (A or D) 2 types for D; 3 types for A 2 types for D; 3 types for A 2 types for D; 2 types for A Rated Voltage Rated Tripping urrents Rated Interruption apacity Approvals 1-pole 2-pole 3-pole 250V A 50/60Hz, 65V D 250V A 50/60Hz, 125V D 250V A, 50/60Hz 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A 0.3A, 0.5A, 0.75A 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 250V A, 50/60Hz, 65V D 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A 2,500A 1,000A, 250V A (50/60Hz), 65V D 1,000A, 250V A (50/60Hz), 65V D UL, SA, E, TUV, 1. For dimensions, see end of each section. 2. UL recognized, applicable standard: UL1077, Supplementary Protectors. 3. ot suitable for branch circuit protection. UL Recognized File o. E68029 File o. LR83454 R Series Lever: UL, SA, VDE Rocker: UL UL, c-ul, VDE * * * 0.3A, 0.5A, 0.75A, 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 2,500A, 220V A (50/60Hz, 1-pole) 1,500A, 220V A (50/60Hz, 2-pole) 1,500A, 65V D (1-pole) 1,000A, 65V D (2-pole) UL, SA File o. B07 09 13332 063 *E, TUV, and apply to 1V. ircuit Breakers

ircuit Breakers 1V Key features: Superior protection for a wide range of devices from sensitive electronic equipment to electrical control circuits. Applications include semiconductor manufacturing equipment, electronic controllers, computers, microprocessors, communications equipment, power supplies, machine tools, motors, and more. Excellent tripping time curve performance Flat retractable lever for safety operations Slim housing design Spring-up terminals allow for use of ring terminals Fingersafe main circuit terminals olor (red/green) contact position indicator DI rail or direct panel mounting (through-panel mounting brackets available) Optional built-in auxiliary / alarm contacts Applicable Standards ertification Mark File umber UL1077 SA 22.2 o. 235 E60934 1V ircuit Breakers E68029 LR83454 B07 09 13332 063 European ommission s Low Voltage Directive GB17701-1999 o. 2008010307265840 Electrical Applicance and Material Safety Law Technical Standard Type 1V: Lever style DI rail and panel mountng o. of Poles 1: 1-pole 2: 2-pole 3: 3-pole Series Trip Relay Trip Internal ircuit 1: Series trip (current trip) 5: Relay trip (voltage trip) Jet Part umber Structure 1V 2 1 00 F 30A A D24V Auxiliary/Alarm ontacts 00: one 21: With one alarm contact 11: With one auxiliary contact 31: With one auxiliary contact and one alarm contact 12: With two auxiliary contacts 32: With two auxiliary contacts and one alarm contact 13: With three auxiliary contacts Inertial Delay Blank: Without F: With * Inertial delay is for A voltage only. * Available with medium and slow trip curves (not applicable with relay trip). Voltage Trip oil Voltage D24V: 24-48V D *Specified for relay trip only. Time Delay urve M: Slow A: Medium S: Instantaneous *Specified for series trip only. Rated urrent 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A 15A, 20A, 25A, 30A *Specified for series trip only. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers

1V ircuit Breakers Terminal Blocks ontactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights Operator Style Internal ircuit Protection Method Specifications Retractable lever Series trip (current trip), Relay trip (voltage trip) Hydraulic magnetic tripping system, Magnetic tripping system (voltage trip) o. of Poles 1-pole 2-pole 3-pole Rated Voltage (A/D) 1 250V A 50/60Hz, 65V D 250V A 50/60Hz, 125V D 250V A, 50/60Hz Series Trip (urrent Trip) Relay Trip (Voltage Trip) 3 Auxiliary ontact/alarm ontact Insulation Resistance Dielectric Strength Rated Short-circuit apacity Rated urrent Operation haracteristics 2 Rated urrent Trip Voltage Vibration Resistance (with rated current applied) Shock Resistance (S time delay curve: 80% rated current, A, M time delay curve: 100% rated current) Electrical Life ontact Rating Minimum Applicable Load 250V A, 2500A 65V D, 2500A 250V A, 2500A 125V D, 2500A 250V A, 2500A 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A Time delay curve curve M (slow), curve A (medium), S (instantaneous) Only curves M and A are also available with inertial delay option. 30A 24 to 48V D (at 25 ) Voltage application duration 10 sec maximum, tripping time 0.1 sec maximum (at rated voltage) 125V A 3A (resistive load), 30V D 2A (resistive load) 24V D 1mA (resistive load, reference value) 100MΩ minimum (500V D megger) 2,000V A, 1 minute (between terminals when main contacts are open, between live parts of different poles, between live and dead parts) 600V A (between terminals when auxiliary circuits are open) Damage limits: 147 m/s 2 (10 to 55 Hz) (1-pole, 2-pole), 78 m/s 2 (3-pole) Operating extremes: 98 m/s 2 (1-pole, 2-pole), 78 m/s 2 (3-pole) Damage limits: Operating extremes: 490 m/s 2 (1-pole, 2-pole), 297 m/s 2 (3-pole) 196 m/s 2 (S, A, M curves) 10,000 cyles minimum (at rated curent), 10 operations per minute Reference Temperature 40 Operating Temperature Operating Humidity Terminal Style Weight (approx.) 10 to +60 (no freezing) Rated current is based on an ambient temperature of 40. When the operating temperature exceeds 40, derate the rated current by using the factors shown below. 45 ~ 85% RH (no condensation) Main ircuit Terminal Spring-up, fingersafe terminal: M4 screw (up to 20A), M5 screw (25A and 30A) Auxiliary/Alarm ontacts, M3.5 screw Voltage oil Terminal 1-pole: 90g, 2-pole: 170g, 3-pole: 260g 1 3-pole model is for A voltage only. 2 For S (instantaneous) tripping curve, a humming sound may occur when used in an A sinusoidal-wave current circuit around 80% of the rated current, however, the performance of the circuit breaker will not be affected. To avoid unnecessary tripping, do not use in circuits where inrush currents may be present. 3 Relay trip (voltage trip) type is not equipped with an overcurrent trip function. Do not use the 1V circuit breakers in environments where they are exposed to extreme temperature, humidity, dust, corrosive gases, vibration, shock, or in a circuit where inrush current may be present, otherwise unnecessary operation and damage may occur. Operating Temp. Derating Factor 50 0.9 55 0.8 60 0.7 ircuit Breakers

ircuit Breakers 1V Models Specify rated current, time delay curve, or voltage trip coil voltage in place of 6 7 8 when ordering. Internal ircuit Series Trip (urrent Trip) Relay Trip (Voltage Trip) o. of Poles Inertial Delay Auxiliary ontact Alarm ontact Part o 1V-1100-6 7 One Auxiliary ontact 1V-1111-6 7 One Alarm ontact 1V-1121 6 7 1-pole 1V-1100F- 6 7 With One Auxiliary ontact 1V-1111F- 6 7 One Alarm ontact 1V-1121F- 6 7 1V-2100-6 7 One Auxiliary ontact 1V-2111-6 7 Two Auxiliary ontacts 1V-2112-6 7 One Alarm ontact 1V-2121-6 7 One Auxiliary ontact 1V-2131-6 7 and One Alarm ontact 2-pole 1V-2100F- 6 7 One Auxiliary ontact 1V-2111F- 6 7 Two Auxiliary ontacts 1V-2112F- 6 7 With One Alarm ontact 1V-2121F- 6 7 One Auxiliary ontact 1V-2131F- 6 7 and One Alarm ontact 1V-3100-6 7 One Auxiliary ontact 1V-3111-6 7 Two Auxiliary ontacts 1V-3112-6 7 Three Auxiliary ontacts 1V-3113-6 7 One Alarm ontact 1V-3121-6 7 One Auxiliary ontact 1V-3131-6 7 and One Alarm ontact Two Auxiliary ontacts 1V-3132-6 7 and One Alarm ontact 3-pole 1V-3100F- 6 7 One Auxiliary ontact 1V-3111F- 6 7 Two Auxiliary ontacts 1V-3112F- 6 7 Three Auxiliary ontacts 1V-3113F- 6 7 With One Alarm ontact 1V-3121F- 6 7 One Auxiliary ontact 1V-3131F- 6 7 and One Alarm ontact Two Auxiliary ontacts 1V-3132F- 6 7 and One Alarm ontact 1-pole 1V-1500-8 2-pole 1V-2500-8 3-pole 1V-3500-8 0.1A 0.3A 0.5A 1A 2A 3A 5A 7A 10A 15A 20A 25A 30A 6 Rated urrent ode 7 Time Delay urve M (slow) A (medium) S (instantaneous) 8 Voltage Trip oil Voltage D24V Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers

1V ircuit Breakers Switches & Pilot Lights 1-pole 1V-1100 (Without auxiliary/alarm contacts) 1V-1111 (With auxiliary contact) Internal ircuits One auxiliary contact. 1V-1121 (With alarm contact) One alarm contact. 1V-1500 (Relay Trip) A B Signaling Lights 2-pole O O D Relays & Sockets 1V-2100 (Without auxiliary/alarm contacts) 1V-2111 (With auxiliary contact) One auxiliary contact. Also available with two auxiliary contacts 1V-2121 (With alarm contact) One alarm contact. Also available with one auxiliary contact and one alarm contact. A B 1V-2500 (Relay Trip) A B D D O O Timers 3-pole 1V-3100 (Without auxiliary/alarm contacts) 1V-3111 (With auxiliary contact) 1V-3121 (With alarm contact) 1V-3500 (Relay Trip) One auxiliary contact. also available with two or three auxiliary contacts. One alarm contact. Also available with one auxiliary and one alarm contact, and two auxiliary and one alarm contact. A A A ontactors B B B Terminal Blocks ircuit Breakers Overcurrent-Time Delay haracteristics (seconds @ 40 deg ) [vertical mounting] Item A (50/60Hz)/D A (50/60Hz) *: MAY TRIP on D Time Delay urve S (instantaneous) O TRIP O Percent of Rated urrent 100% 125% 150% 175% 200% 400% 600% 800% 1000% *0.005 to 0.1 0.003 to 0.06 0.0027 to 0.05 O 0.002 to 0.03 A (medium) O TRIP *25 to 240 16 to 140 6 to 32 0.4 to 4 M (slow) O TRIP *60 to 600 30 to 200 9 to 60 0.4 to 10 With Inertial Delay A (medium) With Inertial Delay M (slow) O TRIP 25 to 240 6 to 32 0.8 to 6 O TRIP 60 to 600 10 to 60 0.8 to 10 D 0.002 to 0.028 0.0055 to 1.5 0.006 to 4.5 0.09 to 3.5 0.06 to 4.5 D 0.002 to 0.025 0.004 to 0.8 0.004 to 1.8 0.02 to 1.8 0.02 to 3 D 0.002 to 0.022 0.004 to 0.65 0.004 to 0.8 to 1.0 to 1.75

ircuit Breakers 1V Time in sec Time in sec Time in sec 1000 100 10 1 0.1 1000 100 10 1 0.1 1000 100 10 1 0.1 100 200 300 400 500 600 700 800 900 1000 125 D (ote) A urrent (percent load of the rated current) Time Delay urves at 40 urve A (medium) 100 200 300 400 500 600 700 800 900 1000 125 A D (ote) urrent (percent load of the rated current) urve S (instantaneous) 100 200 300 400 500 600 700 800 900 1000 125 urrent (percent load of the rated current) ote: Inertial Delay option not available with S (instantaneous) curve. urve A (medium) With Inertial Delay Time in sec Time in sec 1000 100 10 1 0.1 100 200 300 400 500 600 700 800 900 1000 125 D (ote) A urrent (percent load of the rated current) urve M (slow) ote: The entire shaded area applies to A. For D, the shaded area on the right of the dashed line applies. 1000 100 10 1 0.1 100 200 300 400 500 600 700 800 900 1000 125 urrent (percent load of the rated current) urve M (slow) With Inertial Delay Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers

1V ircuit Breakers Timers Relays & Sockets Signaling Lights Switches & Pilot Lights Time Delay urve and Ambient Temperature 1V circuit breakers employ a hydraulic magnetic tripping system, where the rated current (trip current) is not affected by ambient temperatures. But the time delay may vary with the oil viscosity in the oil dash pot. Lower oil viscosity at higher temperatures results in a shorter delay, whereas at lower temperatures the delay will be longer. Temperature orrection urve The time delay curves on the preceding page are measured at 40. With reference to the following curves, time delays can be corrected according to ambient temperature. hange of Time Delay (%) 600 500 400 300 200 100 80 60 40-20 -10 0 10 20 30 40 Ambient Temperature ( ) The time delay is based on an ambient temperature of 40. Time delays at other temperatures are corrected according to the temperature correction curve. The time delay of the instantaneous time delay curve (S) is not affected by ambient temperature. 50 60 70 Relay Trip (Voltage Trip) at 25 Tripping Voltage For D Resistance (Ω) 24-48V 100.0 Tolerance: ±25% Inertial Delay Inertial delay is designed not to trip on a non-repeating single pulse of 20 times the rated current (peak value) for a duration of 8ms. In addition, circuit breakers equipped with inertial delay do not respond to high inrush currents caused by transformer or lamp loads, but perform the specified interruption on subsequent overcurrents. Inertial delay is not available with the series trip curve S (instantaneous). Percent of Rated urrent (%) 12000 10000 8000 6000 4000 2000 1. Percent of rated current Pulse peak current 100 Protector rated current 2. Sinusoidal or parabolic pulse Pulse width (Duration) Pulse peak current When operating temperature exceeds 40, derate the rated current by multiplying the derating factor shown on the right. Operating Temp Derating Factor 50 0.9 55 0.8 60 0.7 1 2 3 4 5 6 7 8 9 10 Pulse Width (ms) ontactors Terminal Blocks ircuit Breakers Impedance and oil Resistance Series Trip (urrent Trip) at 25 Rated urrent For A 50/60 Hz Impedance (Ω) For D Resistance (Ω) urve S urves A, M urve S urves A, M 0.1A 66.0 116.0 43.0 106.0 0.3A 6.6 11.0 4.1 10.0 0.5A 1.92 3.65 0.86 3.40 1A 0.50 0.93 0.25 0.90 2A 0.16 0.27 0.11 0.25 3A 0.07 0.12 0.050 0.11 5A 0.025 0.050 5 0.045 7A 4 0.027 1 0.025 10A 0.007 0.021 0.005 0.020 15A 0.006 0 0.005 0.009 20A 0.005 0.006 0.004 0.005 25A 0.004 0.005 0.004 0.005 30A 0.003 0.004 0.003 0.004 Tolerance: ±25% (up to 20A), ±50% (25A and 30A) Voltage Drop Due to oil Resistance or Impedance The internal resistance or impedance of a circuit breaker tends to be larger for a smaller rated current. Therefore, when circuit breakers with a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, which should also be considered during installation.

ircuit Breakers 1V 1-pole 1V-1100 1V-1111 (Auxiliary ontact) 2-pole 1V-1121 (Alarm ontact) 1V-1500 (Relay Trip) 1V-2100 Dimensions (mm) DI Rail (BD1000) M4 Terminal Screw 12.0 (up to 20A) 6.6 66.0 M5 Terminal Screw (25A or more) O 17.5 12.0 O 17.5 12.0 O M4 Terminal Screw (up to 20A) M5 Terminal Screw (25A or more) M3.5 Terminal Screw 44.0 6.6 48.4 48.4 Terminal over 66.0 66.0 M3.5 Terminal Screw 17.5 Terminal over 29.5 O 3 M5 Terminal Screw (30A) M4 Terminal Srew (up to 20A) M5 Terminal Screw (25A or more) 6.6 6.6 66.0 44.0 DI Rail (BD1000) DI Rail (BD1000) DI Rail (BD1000) Mounting Hole Layout (M4 Mounting Screws) 2-M4 12 Mounting Hole Layout (M4 Mounting Screws) 2-M4 29.5 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers

1V ircuit Breakers Switches & Pilot Lights 2-pole 1V-2111 (one auxiliary contact) 1V-2112 (two auxiliary contacts) 29.5 M4 Terminal Srew (up to 20A) M5 Terminal Screw (25A or more) 6.6 66.0 DI Rail (BD1000) 1V-2121 (one alarm contact) O 44.0 Mounting Hole Layout (M4 Mounting Screws) Signaling Lights 1V-2131 (one auxiliary contact and one alarm contact) 3 Dimensions shown are for 1V-2111 and 1V-2121. 29.5 DI Rail (BD1000) 29.5 M5 Terminal Screws (30A) 6.6 66.0 2-M4 Relays & Sockets 1V-2500 (Relay Trip) O 48.4 3 M3.5 Terminal Screw Terminal over 3-pole Timers 47.0 M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) 6.6 66.0 DI Rail (BD1000) 1V-3100 O 44.0 ontactors 52.5 Mounting Hole Layout (M4 Mounting Screws) 47.0 1V-3111 (one auxiliary contact) Terminal Blocks 1V-3112 (two auxiliary contacts) 1V-3113 (three auxiliary contacts) 1V-3121 (one alarm ontact) 47.0 O M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) 6.6 48.4 DI Rail (BD1000) 66.0 2-M4 ircuit Breakers 1V-3131 (one auxiliary contact and one alarm contact) 1V-3132 (two auxiliary contacts and one alarm contact) 52.5 M3.5 Terminal Srew Dimensions shown are for 1V-3111 and 1V-3121. Terminal over

ircuit Breakers 1V 3-pole 1V-3500 (Relay Trip) 47.0 O 52.5 M5 Terminal Screw (30A) M3.5 Terminal Screw Installation Angle Tripping method is hydraulic magnetic. Minimum operating current varies with installation angle. Operating currents are influenced by the weight of the movable iron core. With reference to the following figures, correct the rated current. 100% 120% 90% 100% 6.6 48.4 Terminal over 66.0 DI Rail (BD1000) Instructions Applicable wire and rimp Terminals Minimum operating current is calculated from the following formula: (Minimum operating current) = (Rated current) (orrection factor by installation angle) (Reference minimum tripping current rate) DI Rails Installation on DI Rail 1. Fasten the DI rail securely. 2. With the latch facing downward, install the 1V circuit breaker on the DI rail as shown below. Removal from DI Rail Using a flat screwdriver, pull the latch on the circuit breaker to remove from the DI rail. Installing Push 35mm-wide DI Rail Removing Flat Srcrewdriver Latch 35mm-wide DI Rail Panel Mounting Screws (not supplied) Screw Type Tightening Torque Shape M4 0.8 to 1.0 m Spring Washer Plain Washer Terminal Main ircuit Terminals Auxiliary ontact Alarm ontact Voltage oil Terminals Terminal Screw Spring-up, fingersafe, slotted Phillips screw with square washer (up to 20A) Spring-up fingersafe terminal (25A and 30A) Slotted Phillips screw with square washer Mounting Hole Layout (M4 Mounting Screws) 2-M4 onnectable Wire Size (mm 2 ) 47.0 Applicable rimping Terminal Tightening Torque ( m) 0.25 to 1.65 R1.25-4 1 to 1.4 1.04 to 2.63 R2-4 2.63 to 6.64 R5.5-4 0.25 to 1.65 R1.25-5 1.8 to 2.2 1.04 to 2.63 R2-5 2.63 to 6.64 R5.5-5 0.25 to 1.65 R1.25-3.5 0.7 to 0.9 1.04 to 2.63 R2-3.5 For wiring the main circuit terminal, use applicable crimp terminals and tighten to the recommended torque. When using the a 1V circuit breaker as a SA-certified product, use with SA-certified crimp terminals. When using the 1V circuit breaker as UL-recognized product, use with UL-recognized crimp terminals. Product Markings (Example: 1V-1111-30AA) Part o. Rated Voltage Rated urrent P E S 220VA J E T 30A I..2500A IRUIT PROTETOR 1V-1111 POLE 1 Ue 250VA 50/60Hz 65VD In 30A URVE A Suppl. Prot. AUX. SW 125VA 3A 30 VD 2A A.T. 40 JAPA PSE ertification o. of Poles Time Delay urve Auxiliary/Alarm ontact Rating Reference Operating Temperature ertification Marks Installation of Auxiliary/Alarm Terminal over After wiring the terminals, install the terminal cover by aligning with the circuit breaker as shown below. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers Terminal cover installed

1V ircuit Breakers Switches & Pilot Lights Accessories Appearance Part o. Description Appearance Part o. Description 9Z-MA11 Panel ut-out Mounting bracket for 1-pole model 9Z-PW1 Marking Plate Holder* Signaling Lights 9Z-MA21 Panel ut-out Mounting bracket for 2-pole model 9Z-LK1 Padlock attachment** Relays & Sockets 9Z-MA31 Panel ut-out Mounting bracket for 3-pole model 1V-AUX-V Replacement Auxiliary/ Alarm Terminal over (ylon - PA66) *Marking plate not supplied. ** Padlock not supplied. Timers 9Z-TA1 Replacement Wiring lip when using panel mount brackets ircuit Breakers Terminal Blocks ontactors