Round Pattern 24 Hour Electromechanical Time Controllers with Half Day & Day Omit

Similar documents
Installation & Operating Instructions

18W Round LED Slimline Emergency Light

24 Hour Immersion Heater Time Controller

Adjustable Pneumatic Time Delay Switch

3000W Dusk to Dawn Light Controller

24 Hour Mechanical Time Switch with Voltage Free Contacts

25W LED Cross Bezel Bulkhead Light

10W LED Die Cast Small Rectangle Bulkhead Light

2x 10W LED Slimline Floodlight Twin Flood

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

18W Low Energy. instructions. Instructions

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

INSTALLATION & OPERATING INSTRUCTIONS

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

Wireless Digital Room Thermostat with Night Set-Back

I n s t a llat ion & O p e r atin g In s truc t ions

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

INSTALLATION INSTRUCTIONS. Timer Features

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Light switch timer 3 step Installation overview 3 minute quick programming guide. A police accredited product.

Installation Instructions: Read these instructions in its entirety before performing any installation work.

##CFG BWOP Manuals## Astramax Mobile Models Assembly Guide

Solar & Roller Shades

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SmartX MF and MS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

WARRANTY...1 NOTICE INTRODUCTION USE...8

Specification Sheet for 2D LED Light

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

RF Point Level Control with Sensor Monitor

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) ES142 Spring Return Electronic Actuators

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

PSU1 Power Supply Unit

Installation Instructions

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Solar Roller & Classic Roller Shades

BM kv Digital Insulation Tester USER MANUAL

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

SINAMICS DCM DC Converter, Control Module

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Cal. VS75A SOLAR SERIES. 4.40mm. Approx. 6 months. Ø 27.0mm. Watch Movement Specification and Drawing. Movement Size. Casing Diameter.

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

HQ Series ¼ Turn Electric Actuator

Installation & User Instructions

Motor-drive mechanism, type BUL. Technical guide

MF /MS Series

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

CARTRIDGE REPLACEMENT MANUAL

Series A Electric Linear Actuators

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

5 mm contact pin pitch PCB or 95 series sockets

Solar & Roller Shades

King Dome. user manual

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Product card User manual. KP Strong Safe

MANUFACTURED IN THE UK

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

MANUFACTURED IN THE UK

Product card User manual. KP Strong Safe

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

ALEX-TRONIX SMART CLOCK TM. BATTERY POWERED TEMPERATURE BUDGETING CONTROLLER MANUAL Patent Pending A DIVISION OF GNA INDUSTRIES, INC.

Duo water control system

Installation Instructions

2 HP PADDLE WHEEL AERATOR

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

40 Series - Miniature PCB relays A. Features

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Power Supplies. 11/2 Introduction

Operating Instructions

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

SonoSelect and SonoSafe energy meters

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Instruction Manual MINI IRRIGATION CONTROLLER.

Direct Coupled Damper Actuator Model MY6050A1001

Transcription:

Round Pattern 24 Hour Electromechanical Time Controllers with Half Day & Day Omit Cat Nos. RTS113/RTS113Q/RTS114/RTS114Q Installation & Operating Instructions

RTS113/RTS113Q/RTS114/RTS114Q Round Pattern Electromechanical Timeswitches 7 day control (blue) 24 hour control (Red) Permanent ON override push button 7 day programming ring (divided into 12 hour steps) Blue tappet (OFF) Time marker 1 Permanent override indicator AM segment PM segment 24 hour programme ring Red tappet (ON) Terminal cover 1.0 Description: 1.1 Application The RTS113/RTS113Q/RTS114/RTS114Q round pattern electromechanical, double insulated time controllers come with a 3 or 4 pin plug-in wirable base. They are compatible with the bases used for the single channel ON/OFF mains linked and voltage free industry standard round pattern timeswitches. Consequently the RTS113/RTS113Q/RTS114/RTS114Q can be considered as plug-in service replacements for these units as well as for new installations. 1.2 Features The timeswitch comes in four forms all driven by quartz controlled stepping motors with mains linked contacts, the RTS113 and the RTS113Q with battery back-up and with voltage free contacts, the RTS114 and the RTS114Q with battery back up. Override to next programme change (daily programme only). Permanent ON facility. RTS113Q/RTS114Q only battery power reserve continuously charged while the unit is connected to mains. Daily operation with half day(s) and day(s) omit.

2 1.3 Technical Data Type: Type of programme: Operating voltage: *Switching capacity: Contact material: Type of contact: Time base: RTS113/RTS113Q/RTS114/RTS114Q Daily with half day(s) and day(s) omitted over a 7 day period if required 220-240V AC 50Hz 20A, 240V~ for resistive loads Hard silver ON/OFF mains linked RTS113/RTS113Q, voltage free RTS114/RTS114Q Quartz Operating accuracy: ± 1 sec./day at 23 C Min. switching interval: Max. no. of switchings: Power reserve: 30 min, which can be increased in 15 minute steps. 48 (in a 24 hour period) Ambient temp. range: -10 to 40 C Rechargeable battery giving 72 hours back up RTS113Q/RTS114Q only Class of shock protection: Class 2 Dirt and moisture protection: IP20 Conforms to directives: Conforms to latest directives Control type: 1B Cable capacity: 1 x 6mm, 2 x 4mm, 3 x 2.5mm. 1mm and 1.5mm can also be used but it is recommended these are folded back *For all other loads please contact Timeguard on 020 8450 0515 1.4 Dimensions 131 100 76

3 2.0 Installation Instructions: 2.1 Safety Information The RTS113/RTS113Q/RTS114/RTS114Q should only be installed by a trained electrician. The I.E.E. wiring regulations must be observed. The supply must be disconnected before wiring commences and a means of isolation with a separation of 3mm in each current path must be provided in the supply to the RTS unit. This product must not be installed where it may come into direct contact with liquids. The RTS unit is suitable for fixed wiring applications only. 2.2 Electrical Interference Despite elaborate safety precautions, exceptionally strong electrical fields may interfere with any electronically controlled timeswitch. We therefore recommend that you observe the following points before installation: Suppress interference caused by inductive loads by means of an RC filter and/or varistor (VDR). Do not install the RTS unit in close proximity to sources of interference, eg transformers, contactors, Pcs and TV sets. 2.3 Wiring Diagrams Fig 1a RTS113/ RTS113Q N 2.4 Installation Three fixing holes B countersunk with central knock out L 1 2 3 SL Load N Fig 1b RTS114/ RTS114Q Voltage between V and COM any AC voltage up to 250V V COM L N SV COM LOAD Fixing screw A for terminal cover which also retains the plug-in timeswitch assembly Transparent cover Lug D on cover Lug C on base Fig 2 Three cable holes leading to terminals 1, 2 and 3 (terminal cover removed) Fig 4a RTS113/RTS113Q Base Base Terminal cover Fig 3 Base 4 cable/conduit knock outs in terminal cover (2 at the bottom, 1 at each side) Base Three cable holes leading to terminals 1, 2 and 3 (terminal cover removed) Fig 4b RTS114/RTS114Q

4 Remove the transparent cover from the RTS unit by rotating it anticlockwise through 30 and then pulling it clear. Unscrew the screw A (see fig. 3), remove the terminal cover and pull the timeswitch plug-in assembly clear of the base. Drill out the three fixing screw holes in the base (see fig. 2) and use 3 x No. 8 woodscrews (with wall plugs if necessary) to fix the RTS unit to the mounting surface. Alternatively the unit may be fixed to panelling using 2B.A. or 5mm screws but if the panelling is conducting it must be adequately earthed in accordance with the I.E.E. wiring regulations. In either case ensure that the screws are countersunk and tightened fully so that there is no projection above the surface of the base. Strip 8mm of insulation from the end of each wire and insert in the appropriate terminal (see figs 1 and 4). Securely tighten the terminal screws onto the wires and push the timeswitch plug-in assembly fully home into the base to ensure electrical safety. Remove the appropriate knock-outs in the terminal cover and locate the cover over the cables or conduit, securing with screw A. After commissioning the installation replace the transparent cover by pushing over the base and rotating clockwise ensuring that lugs C and D on the base and cover are lined up as in fig. 2. If the transparent cover is required to be locked this can be achieved by a padlock through the lug C with lugs C and D in the position shown in fig 2. Alternatively the holes in lugs C and D can be lined up, wired and sealed. The fixing screw A (fig 3) securing the terminal cover can also be secured by wiring and sealing. 3.0 Programming: 3.1 24 hour programming and clock time/day of week setting. Insert red tappets into the programme ring to set the required ON times and the blue tappets to set the required OFF times (see examples in fig 5). Up to 24 complete ON/OFF programmes can be set over a 24 hour period. The correct day of the week (Wed) can now be set by referring to fig 5 and rotating the 24 hour programme ring in a clockwise direction until the first digit of the appropriate half day marker e.g. (Wed AM 1st digit 2) is opposite the time marker. The correct clock time (1500 hours see fig 5) can now be set by continuing to rotate the ring in a clockwise direction until the appropriate marker on the 24 hour ring is above the time marker. The condition of the red (24 hour) control now needs to be checked and changed if necessary by turning the red control shaft in an anticlockwise direction using a small screwdriver. If the last tappet on the 24 hour ring to pass the time marker in a clockwise direction is blue the slot in the red control shaft needs to be aligned with any symbol (OFF) and any symbol (ON) if the last tappet is red. Next ensure that all the seven day segments have their screwdriver slots parallel to the 7 day ring If not, turn in a clockwise direction with a small screwdriver until they are. Note: Excess force used to turn a segment in an anticlockwise direction will damage the timeswitch. Finally set the 7 day (blue) output control to ON if necessary by turning the blue control shaft with a small screwdriver in a clockwise direction until the screwdriver slot in the shaft is aligned with any symbol. Finally ensure permanent override indicator is set to AUTO. The RTS113/RTS113Q is now ready for service as a 24 hour timeswitch. Note: Excess force used to rotate the programme ring and the blue control shaft in an anticlockwise direction or the red control shaft in a clockwise direction will damage the timeswitch.

7 day output control (blue) 24 hour output control (red) Time marker OFF at 1200 (blue tappet) ON at 0900 (red tappet) AM marker bar Permanent override indicator Segment set to change 7 day output Fig 5 ON at 2000 (red tappet) OFF at 2200 (blue tappet) 5 3.2 Half day and day omit programming and 7 day control setting. This is required only if the programme set on the 24 hour ring is not needed for one or more half days. An example is shown in fig 5 where the requirement is to have no operation on Thursday (day 4) afternoon and all day Friday (day 5). The 7 day switch segments between 4 and 4 (midday Thursday) as well as between 5 and 6 (midnight Friday) have been turned anti-clockwise with a small screwdriver until the segment slot is aligned radially so that the 7 day output will be changed as each of these segments passes the time marker. Excessive force used to turn a segment anticlockwise will cause damage. The 7 day (blue) output will also need to be set manually in the right initial condition. In the example shown in fig 5 when the time marker points within the period midday Thursday to midnight Friday the setting will be OFF and outside this time period ON. This is achieved by using a screwdriver to turn the 7 day control in a clockwise direction until the slot points to a for OFF or a for ON. In the situation shown in fig 5 the control needs to be set ON. Finally ensure permanent override indicator is set to AUTO. The 7 day control must only be rotated in a clockwise direction. The screwdriver slot in the control is shaped to prevent rotation in the opposite direction. 3.3 Override to next programme change. The red 24 hour control can be turned anticlockwise by one click. This will change the present output of the RTS unit and will last until the next programme change. The 7 day control must only be rotated in a clockwise direction. The screwdriver slot in the control is shaped to prevent rotation in the opposite direction. 3.4 Permanent Override ON. The RTS unit can be permanently overridden ON by pressing the red button on the outside of the case and transparent cover adjacent to the 7 day and 24 hour controls. The override can be terminated by pressing the button again. The state of the timeswitch either permanently ON or in Auto is indicated by the pointer adjacent to the 7 day and 24 hour controls.

3.5 Programming Overview 7 day output control (blue) 24 hour control (red) Red tappet Time marker Clockwise direction for 24 hour and 7 day rings Sunday markers (in red) Blue tappet 6 2 segments set to give changes to 7 day control at midday Thursday and midnight Thursday. With 7 day control set at (ON) above no 24 hour operation will occur between midday and midnight each Thursday. Fig 6 7 day ring 24 hour ring Note: all other 7 day ring segments are in the no change orientation and are not shown for clarity 24 Hour Ring Red tappet for ON operation. Blue tappet for OFF operation. Fig 2 shows an ON period starting at 1200 and ending at 1500. Radial slot 24 Hour Control If last tappet past time marker was blue 24 hour control should show (OFF) and (ON) if it was red. 7 Day Ring Segments with screwdriver slots positioned radially cause a change on the 7 day control. The 7 day contacts are in series with the 24 hour contacts controlling the timeswitch output, so the 7 day contacts need to be closed ( ON) for the 24 hour contacts to be operational. Finally ensure permanent override indicator is set to AUTO. 4.0 5 Year Guarantee In the unlikely event of this product becoming faulty, due to defective material or manufacture, within 5 years of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge. Should you encounter any difficulty please contact our helpline on 020 8450 0515. 5.0 Additional Tappets 4 red and 4 blue tappets are supplied with the RTS unit. If further tappets are required they may be obtained from Timeguard quoting the numbers 934 3 311 BLUE, 934 3 035 RED. Please ring 020 8450 0515.

For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com 67-058-78 (issue 3). Zerofour November 2013