SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Similar documents
SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

SPECIFICATIONS FOR HYDRAULIC PTO DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

Darley UHP-HV Diesel Specification 1

PyroLance B 2000 M-G Technical Manual

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

B Pump Mounting. Page 1 of 7

STRIKERTM SERIES STRIKER-3 HIGH PRESSURE 3-STAGE FIRE PUMP. Features and Benefits. Applications DATA SHEET

Portable Pumps Transportable MaxStream Diesel Floating Pumps Pro Kit Skid and Trailer

PRODUCT RELEASE CKMTA12 / 24

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M

Solenoid Operated Block Valves A2800 Series

PARTS LIST FOR CBA MHB (AFTER SERIAL # ) CBA MVB

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

VERSAX SERIES VERSAX SELF-PRIMING 2-STAGE FIRE PUMP PORTABLE & WRAP-AROUND. Applications. Features and Benefits DATA SHEET

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

FIRE KNAPSACK FIRE RESPONSE UNITS FIRE TRAILERS. Fire Fighting. Pages Designed to perform better.

BB-4 DIESEL BB-4-D902 VEHICLE MOUNT HIGH PRESSURE 4-STAGE FIRE PUMP. Applications. Features and Benefits DATA SHEET

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

PARTS LIST FOR CA MHB/RB (AFTER SERIAL # ) CA MVB

OWNER S MANUAL. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/5.5 HP Engine, 4-Roller Pump & Deluxe Handgun) Assembly Instructions

TECH WEST INC. Manufacturers of Dental Vacuum and Air Systems N. Argyle Ave. Fresno, CA (559) (800) FAX (559)

FOR YOUR SKID SPRAYER?

Car Wash / Pressure Washer

OPTIONS SLIP-ON FIREFIGHTING UNITS

ULTRA CLEAN OILLESS COMPRESSOR

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

PARTS LIST FOR 4004 SERIES PORTABLE/ALUMINUM GASOLINE DRIVEN/BELT DRIVE COLD WATER PRESSURE WASHER

Compressor Installation Guide

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

HDC SERIES (AFTER SERIAL # )

PARTS LIST FOR CA MHB (AFTER SERIAL # ) Engine Oil Grade: SAE 10W-30 Engine Oil Capacity: 37 oz.

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SR14-30M AGW-SR14-B

M-3025CB-AV Fuel Pump

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

CM MHC CM MHC CM MKC CM MMC

Model: SK-61-4R 60 Gallon Skid Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Albemarle County Virginia Brush Fire Truck Specification

PARTS LIST FOR HDS SERIES (AFTER SERIAL # and # )

32 quarts Transmission Allison HT 740 Automatic Fluid

MITSA INTERNATIONAL P.O.

8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP MHB/VB

GENERAL PUMPA member of the Interpump Group

4/3/2014 Ryobi Electronics Parts Catalog -- Ryobi Power Tools Consumer: [H301PL 3 Gallon Air Compressor (Husky)]/[Figure A]

PUMP ACCESSORIES. Pump Accessories 40,000 PSI

MODEL NO. UTL-60-7

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

PARTS LIST FOR HDB H6G HDB K7G

PARTS LIST FOR CV MBC. Engine Oil Grade: Above 40 F=SAE 30 Below 40 F=SAE10W-30 Engine Oil Capacity: Pump Oil Capacity:

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

D7G. Track-Type Tractor

INSTALLATION AND USER MANUAL

PARTS LIST FOR AIR COMPRESSORS AC-SH20-2 AC-SV20-2 ENGINE OIL GRADE: HONDA: SAE 10W-30. Below 40 F=SAE 10W-30 ENGINE OIL CAPACITY:

SECTION D Engine 6.0L Diesel

Type 2 Push-Through 37 Ton Log Splitter. Assembly Manual

SECTION AXIAL HVAC FANS

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

DIAMOND CONCRETE SAW PARTS LIST MODEL CC8000 P R O D U C T S. (Revised )

CALIFORNIA Proposition 65 Warning:

Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling

Hose & Apparatus Test Equipment

HIGH VELOCITY PUMP PUMP END

Climas y Proyectos Leyco, S.A. de C.V.

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Table of Contents WARRANTY

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

Priming Systems Installation Instructions

PARTS LIST FOR CV MBC. Engine Oil Grade: Above 40 F=SAE 30 Below 40 F=SAE10W-30 Engine Oil Capacity: Pump Oil Capacity:

IMMERSION FIRED HOT WATER BOILER

2 YEAR WARRANTY HOSE REELS. reelmaster Series heavy duty, quality hose reel engineered to save space

Model &

Custom Vac 822 Hydrovac with the following specifications (Tri Drive Mounted):

Illustrated Parts List to

PARTS LIST FOR HDC SERIES (AFTER SERIAL # and # )

(800)

PRESSURE WASHERS Cage Frame Pressure Washers

This unit has been used for many years to power the TapMate Too (351-00) with the hydraulic drive head attachment ( ).


Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

Genset. Parts Catalog HDKAG

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5

M-B Companies, Inc. Specification. Model 155 PLS-155. Palletized Striper. High Pressure Airless. 2 x 55 Gallon Drum. Standard Rev. 2 January 11, 2008

350 Series Electrohydraulic Actuators

PARTS LIST FOR CW ME3 (AFTER SERIAL # )

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

PARTS LIST FOR PW-2702H

Transcription:

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire. The high pressure firefighting system shall allow the operator to attack fire from a safe position. The system shall be extremely effective on wildland fire and initial fire attack operations with limited water supplies. Components and Module Design The firefighting system shall consist of: Engine: diesel driven engine Water pump: high pressure positive displacement piston pump Hose Reel: high pressure hose reel and attack hose Nozzle: manually operated pistol grip high pressure nozzle The major components shall be assembled on a removable assembly with integral engine. The entire system shall be designed to be a quickly installed or removable plug-and-play module. Safety and Standards Compliance The system shall be designed for the safety of the operator and fire fighter in mind with a safety margin of 4:1 built into all components. Performance Capabilities The firefighting system shall be tested and proven to be highly effective in the following scenarios: Wildland, grass, and brush fire applications 6140 S Gun Club Road, Ste. K6-270 Aurora, Colorado 80016 USA +1 (303) 952.5018 +1 (303) 474.3104 www.pyrolance.com

Automobile and truck fires Limited structural fires Confined or concealed space fires Limited industrial fires Shipboard and marine firefighting Military firefighting applications Container fires BASE PLATE MOUNTING The firefighting system shall be packaged in a self-supporting base plate with dimensions of 36 ( 914 mm) right to left, 24 (610 mm) front to rear (deep), and 32 (813 mm) top to bottom. The mounting assembly shall be powder coated and shall be designed to contain the specified major components of the system. ULTRA HIGH PRESSURE FIRE PUMP SPECIFICATIONS The firefighting system shall be equipped with a heavy duty ultra-high pressure three plunger type positive displacement fire pump. The pump shall be driven as specified under the drive system section of these specifications. The pump shall have the following features: Operational rating: 20 gpm at 1500 psi ( 80 lpm at 100bar) Solid Keyed Shaft Brass Manifold Stainless Steel Check Valve Stainless Steel Plunger Guides Bronze Connecting Rods POLY DRIVE SYSTEM SPECIFICATIONS The ultra-high pressure fire pump shall be equipped with a tooth-type Poly Belt drive system between the engine and the fire pump. The pulley ratio shall be appropriate for the engine type to produce the specified fire pump performance. ENGINE INSTALLATION The firefighting system shall be powered by a HATZ diesel engine. The engine installation shall be designed with adequate cooling and ventilation air in the mounting area. The engine shall have the following specifications: HATZ 2M41 Type: air cooled 4 Stroke Cylinders: two Horsepower: 34 (gross) RPM: 3,000 Oil filter and cooler Choke control Oil alert system 2

EXHAUST SYSTEM The fire pump engine shall have a muffler, water flip cover, heat guard, and exhaust pipe installed on the engine assembly. The exhaust pipe shall be directed vertically and away from the pump operator panel. DIESEL FUEL TANK A built in plastic fuel tank shall be installed for the specified gasoline engine. The fuel tank shall have capacity of approximately 4 gallons (15 liters). A shut/off valve and flexible fuel line shall be furnished. ELECTRIC SUPPLY CABLE AND CONNECTION The 12 volt electrical power supply to the firefighting assembly from the chassis battery location shall use 30' (9 m) flexible stranded copper wiring cables (positive (red) and neutral (black)) properly sized to the anticipated electric load. The installation kit shall be equipped with protective electrical loom, cable clamps, battery terminal connections, and plastic wrap ties for installation in the chassis. An automatic reset circuit breaker shall be supplied for installation at the truck battery location. This power supply cable shall be equipped with an Anderson type quick disconnect female and male receptacle plug. A firefighting pump instruction nameplate and necessary warning labels shall be installed on the assembly (English language). A fire pump engine shall be equipped with an hour meter and tachometer and shall be installed on the control panel. The fire pump engine oil drain shall be equipped with a 12 (300 mm) long wire braided hydraulic type hose, with valve, plug, and identification label. The pump control panel shall be provided with a 12 volt panel light with switch. PUMP CONTROL PANEL The control panel shall be ergonomically designed and operator friendly. The panel shall be labeled and installed to be easily visible from the operator s position. The following instruments and controls shall be installed: Emergency stop (red) switch Reel discharge control valve Electric tank to pump control switch Momentary contact two-position start-stop ignition switch Control panel light and switch One (1) UHP pressure gauge PLUMBING The firefighting system shall be plumbed with high pressure hydraulic type hose, plumbing and fittings. This shall include double wire braided high pressure hoses of various sizes, zinc plated steel hose ends, and plated steel hydraulic fittings. The threads shall be male and female NPT, JIC and SAE O-ring style in various sizes. Rigid plumbing shall be in zinc plated steel piping with pipe fittings of zinc plated steel. 3

BYPASS UNLOADER VALVE The ultra-high pressure plumbing system shall include a bronze adjustable by-pass unloading valve set for the maximum working pressure of the system. The valve shall unload the main pump to the intake side of the pump. PRESSURE SAFETY, EASY START, THERMAL RELIEF VALVE The ultra-high pressure plumbing system shall include the following devices: A) one (1) pressure safety relief valve which shall relieve water pressure to atmosphere; set at a slightly higher pressure than the unloading valve. B) one (1) thermal relief valve which shall open if water temperatures exceed 145 F (62 C) degrees; designed to protect the pump from high temperature conditions and relieve the water to atmosphere. C) one (1) easy start valve INTAKE FILTER A 1.25" (31 mm) water filter with 32 mesh stainless steel screen shall be installed in the water supply line to the fire pump. The filter shall be accessible for cleaning the screen. ELECTRICAL WIRING Necessary low voltage automatic circuit breaker protection shall be provided where required. Wiring shall be stranded copper automotive type, sized for the appropriate electrical load. Exposed wiring shall be protected with convoluted split plastic loom; such looms shall be mechanically secured. Wiring shall be run in protected areas or enclosed in metal panels where subject to mechanical injury. Electrical connections and termination of wiring shall be within weather proof plastic enclosures with waterproof strain relief's and connectors. WATER TANK SUPPLY LINE A 1.25" (31 mm) water tank to fire pump line shall be installed as follows: a) From the fire pump to the water filter shall be a 1.25 (31 mm) flexible transparent hose. b) One (1) 1.25 (31 mm) two-way electric valve controlled on pump panel c) Fifteen feet (4 meters) of 1.25 (31 mm) flexible water hose with removable connections and clamping devices. One (1) 2.5 (65 mm) liquid filled pressure gauge shall be installed from the discharge side of the ultrahigh pressure fire pump, with the gauge mounted on the pump panel. THROTTLE CONTROL The engine speed control shall be a mechanical throttle which shall automatically increase engine RPM speed when actuated and when released shall return the engine speed to idle. ELECTRIC HOSE REEL ULTRA HIGH PRESSURE One (1) painted ultra-high pressure steel hose reel shall be installed. The reel shall have leak proof ball bearing swing joint, positive pin locking device, electric 12 volt rewind provisions. The reel shall be plumbed with wire reinforced, high-pressure hose coupled with brass fittings. The reel system shall have a minimum of 4:1 safety ratio and designed for a 2,000 PSI (138 bar) working pressure. 4

The hose reel shall be installed by the installing agency. The high pressure hose reel shall be supplied by a 0.500 (12 mm) hydraulic type wire braided flexible hose line. One (1) push button electric rewind control shall be installed near the reel. The wiring from the hose reel electric box shall be protected with conduit or loom. The rewind button control shall be mounted in a sealed plastic electrical box. The hose reel shall be equipped with an electrical wiring junction box of plastic construction with a sealed cover assembly. The box shall house the reel solenoid, circuit breaker, and electrical wiring for the rewind control circuit and electric rewind motor power supply. The electrical supply shall be sized for the reel motor for both positive and neutral cables. The electrical supply wiring shall be supplied from the main electrical supply box for high pressure pump skid or module. The supply line to the reel shall have a quick disconnect connection (Anderson style plug) at the main electrical supply box. One (1) chrome plate hose roller assembly shall be supplied for protection of the hose during hose removal and rewind operations. A positive pin type locking device shall be installed on the reel. REEL MOUNTED HIGH PRESSURE HOSE 150 foot (45m) length x 3/4" (19 mm) hose shall be installed with threaded couplings. The hose shall have a working pressure of 3125 psi (215 bar). NOZZLE -- ULTRA HIGH PRESSURE One (1) 20 gpm (80 lpm) ultra-high pressure pistol grip fog nozzle shall be provided for the high pressure reel. OPTIONS AND MODIFICATIONS: (INSERT OPTIONS AND MODIFICATIONS ONLY IN THIS SPACE) FACTORY TESTING PRIOR TO SHIPMENT The entire pump and the plumbing system shall undergo a complete factory test. These test results shall be provided with shipment. CRATING The equipment shall be properly crated, sealed, and protected for shipment. The crate shall be approximately: 48" (1219 mm) wide x 48" (1219 mm) long x 36" (914 mm) high in size and less than 500 lbs. (227 kg) in weight. WARRANTY The PyroLance ultra-high pressure type firefighting system components shall be covered by a one (1) year parts and labor warranty. The installation portion of the warranty shall be covered by the final stage assembler. 5

TECHNICAL MANUAL The ultra-high pressure firefighting system shall be covered by a highly detailed technical manual covering installation, testing, operation, maintenance, and parts. This manual shall have various levels of warnings and caution notices provided. The manual shall be spiral bound with divided sections with a CD electronic version. 07-150-20140307 6