Installation and Operation

Similar documents
Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Installation, Operation, and Maintenance

Installation. Loadbuster The S&C Loadbreak Tool Outdoor Distribution (14.4 kv through 34.5 kv) Table of Contents. Instruction Sheet

Installation and Operation

Inspection and Maintenance

Instructions for Installation and Operation

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

S&C Vista Underground Distribution Switchgear

Instructions for Installation

Installation and Operation

Figure 1. Kearney Type HX cutout.

Instructions for Installation

S&C Circuit-Switchers Mark VI Installed on S&C Mounting Pedestals 84- through 102-inch Phase Spacing Outdoor Transmission (69 kv through 138 kv)

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Instructions for Installation and Operation

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Installation and Operation

Cleaning Flooded Gear

S&C Source-Transfer Vista Underground Distribution Switchgear

Installation And Operation

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Cleaning Flooded Gear

ibusway for Data Center

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

Installation Instructions For Motor Control Center (MCC) Units

TYPE AST. Grounding Switch. ALL Ratings INSTALLATION & INSTRUCTION MANUAL

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

Effective June 2016 New Issue

Installation. S&C Circuit-Switchers Mark VI 69-kV 51-inch Phase Spacing Single Pedestal Design Outdoor Transmission.

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Operating Instructions & Parts Manual. Fuel Tank Adapter

Effective March 2015 Supersedes S August 2012

MFG. CO. INC. DODGE CITY, KANSAS (620) Electric Truck Auger. Owners Manual

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

TONS. Before each shift: Before operating: Before initial operation of hoist:

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

INSTRUCTIONS For Field Assembly, Installation, and Maintenance

CRP-series Carpet Rams Instruction Manual

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Galaxy Receiving and Unpacking 09/

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

FUSE LINKS. Catalog 10B October Phone: Web: hubbellpowersystems.com October 2015.

Installation Instructions Electric Heaters 5 20 kw

IB PowlVac ITE-HK Remote Racking Device

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

S&C Loadbuster Disconnects

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Vacuum Circuit Breaker (Vehicle)

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

CAUTION CAUTION indicates a potentially

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Instruction Manual. ATV Plow Tube System

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

37SCENE 46SCENE 79SCENE

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

Firstmate Installation Manual and User's Guide May, 2003

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Lincoln Hoist. Web Hoist Operating Manual. Lincoln Hoist

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

Instructions for Operation and Maintenance

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

SecoVac * Ground & Test Device

OLYMPIAN MODEL 740 Operation and Service Manual

Rev. 10/27/2015 CDL-2000, MANUAL

Type NR oil switch installation and operation instructions

S&C Type XS Fuse Cutouts

Installation, Operation and Maintenance Instructions. SLS Series Single Phase Disconnector

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

OPERATION MANUAL. TWE Pin Welder. Model TWP-2 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330) Revision 2.

Original. User Manual & Install Guide. Safe-T-Pull Inc. Page 1 of 15

08/2010 Rev. 2/7/2018 DGS-A, MANUAL. DGS-A, DGD-A, & DGS-AG Fork-Mounted Drum Lifters Use and Maintenance Manual DGS-AG

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

OPERATOR S AND PARTS MANUAL PALLET FORKS. Part Number: MODEL NUMBER: Rev. 4

INSTALLATION INSTRUCTIONS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

SBRL-SERIES SPREADER BEAMS INSTRUCTION MANUAL

Transcription:

S&C Three-Shot Type XS Fuse Cutout Outdoor Distribution (4.16 kv through 15 kv) Installation and Operation Table of Contents Section Page Section Page Introduction Qualified Persons... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet.... 2 Proper Application.... 2 Warranty.... 3 Warranty Qualifications.... 3 Safety Information Understanding Safety-Alert Messages.... 4 Following Safety Instructions.... 4 Replacement Instructions and Labels.... 4 Safety Precautions... 5 Shipping and Handling Inspection.... 5 Storage (if needed).... 5 Installation Mounting the Three-Shot Type XS Fuse Cutout... 6 Installing the Fuse Link Three-Shot Type XS Fuse Cutouts Without an Arc-Shortening Rod.... 6 Three-Shot Fuse Type XS Cutouts With Arc-Shortening Rod.... 7 Installing and Closing the Fuse Tubes.... 8 Restoring the Three-Shot Cutout When Three Fuse Tubes Have Dropped Open.... 9 Restoring the Three-Shot Cutout When Two Fuse Tubes Have Dropped Open.... 10 Restoring the Three-Shot Cutout When One Fuse Tube Has Dropped Open.... 11 Opening the Fuse Tube.... 12 Operation Operating with Loadbuster The S&C Loadbreak Tool.... 13 January 11, 2016 S&C Electric Company 2011-2016, all rights reserved Instruction Sheet 351-501

Introduction Qualified Persons Read this Instruction Sheet Retain this Instruction Sheet Proper Application WARNING The equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of primary distribution fusing equipment along with associated hazards. A qualified person is one who is trained and competent in: The skills and techniques necessary to distinguish exposed live parts from nonlive parts of electrical equipment. The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the qualified person will be exposed. The proper use of the special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electrical equipment. These instructions are intended only for such qualified persons. They are not intended to be a substitute for adequate training and experience in safety procedures for this type of equipment. Thoroughly and carefully read this instruction sheet before installing or operating your S&C Three-Shot Type XS Fuse Cutout. Familiarize yourself with the Safety Information on pages 4 and 5. The latest version of this publication is available online in PDF format at sandc.com/support/product-literature.asp This instruction sheet should be available for reference whenever fuse cutouts are used. Retain this instruction sheet in a location where you can easily retrieve and refer to it. CAUTION Three-Shot Type XS Fuse Cutouts must only be used for specific fusing applications that are within the ratings of the model selected. Three-Shot Type XS Fuse Cutout ratings are listed on a ratings label attached to the unit. 2 S&C Instruction Sheet 351-501

Introduction Warranty Warranty Qualifications The warranty and/or obligations described in S&C s standard conditions of sale, as set forth in Price Sheet 150, plus any special warranty provisions, as set forth in the applicable product-line specification bulletin, are exclusive. The remedies provided in the former for breach of these warranties shall constitute immediate purchaser s or end user s exclusive remedy and a fulfillment of all seller s liability. In no event shall seller s liability to immediate purchaser or end user exceed the price of the specific product that gives rise to immediate purchaser s or end user s claim. All other warranties, whether express or implied or arising by operation of law, course of dealing, usage of trade, or otherwise, are excluded. The only warranties are those stated in Price Sheet 150, and THERE ARE NO EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY EXPRESS WARRANTY OR OTHER OBLIGATION PROVIDED IN PRICE SHEET 150 IS GRANTED ONLY TO THE IMMEDIATE PURCHASER AND END USER, AS DEFINED THEREIN. OTHER THAN AN END USER, NO REMOTE PURCHASER MAY RELY ON ANY AFFIRMATION OF FACT OR PROMISE THAT RELATES TO THE GOODS DESCRIBED HEREIN, ANY DESCRIPTION THAT RELATES TO THE GOODS, OR ANY REMEDIAL PROMISE INCLUDED IN PRICE SHEET 150. The standard warranty contained in seller s standard conditions of sale (as set forth in Price Sheet 150) does not apply to S&C Three-Shot Type XS Fuse Cutouts, Outdoor Distribution, when installed in conjunction with fuse tubes of other than S&C manufacture. S&C Instruction Sheet 351-501 3

Safety Information Understanding Safety-Alert Messages Several types of safety-alert messages may appear throughout this instruction sheet as well as on labels and tags attached to the Three-Shot Type XS Fuse Cutout. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below: DANGER DANGER identifies the most serious and immediate hazards that will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed. WARNING WARNING identifies hazards or unsafe practices that can result in serious personal injury or death if instructions, including recommended precautions, are not followed. CAUTION CAUTION identifies hazards or unsafe practices that can result in minor personal injury or product or property damage if instructions, including recommended precautions, are not followed. NOTICE NOTICE identifies important procedures or requirements that, if not followed, can result in product or property damage if instructions are not followed. Following Safety Instructions If you do not understand any portion of this instruction sheet and need assistance, contact your nearest S&C Sales Office or S&C Autho rized Distributor. Their telephone numbers are listed on S&C s website sandc.com. Or call S&C Headquarters at (773) 338-1000; in Canada, call S&C Electric Canada Ltd. at (416) 249-9171. NOTICE Thoroughly and carefully read this instruction sheet before operating your S&C Three-Shot Type XS Fuse Cutout. Replacement Instructions and Labels If you need additional copies of this instruction sheet, contact your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. It is important that any missing, damaged, or faded labels on the equipment be replaced immediately. Replacement labels are available by contacting your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. 4 S&C Instruction Sheet 351-501

Safety Precautions DANGER Three-Shot Type XS Fuse Cutouts operate at high voltage. Failure to observe the precautions below will result in serious personal injury or death. Some of these precautions may differ from company operating procedures and rules. Where a discrepancy exists, follow your company s operating procedures and rules. 1. QUALIFIED PERSONS. Access to Three-Shot Type XS Fuse Cutout must be restricted only to qualified persons. See Qualified Persons on page 2. 2. SAFETY PROCEDURES. Always follow safe operating procedures and rules. 3. PERSONAL PROTECTIVE EQUIPMENT. Always use suitable protective equipment, such as rubber gloves, rubber mats, hard hats, safety glasses, and flash clothing, in accordance with safe operating procedures and rules. 4. SAFETY LABELS AND TAGS. Do not remove or obscure any of the DANGER, WARNING, CAUTION, or NOTICE labels and tags. Remove tags ONLY if instructed to do so. 5. ENERGIZED COMPONENTS. Always consider all parts live until de-energized, tested, and grounded. 6. OPERATING TOOLS. To close a Three-Shot Type XS Fuse Cutout, use a conventional insulated hookstick or S&C Universal Pole and Pole Extension fitted with an S&C Talon Handling Tool or a distribution prong. To open the Three-Shot Type XS Fuse Cutout, use Loadbuster The S&C Loadbreak Tool, attached to a conventional insulated hookstick or S&C Universal Pole. 7. MAINTAINING PROPER CLEARANCE. Always maintain proper clearance from energized components. Shipping and Handling Inspection Storage (if needed) WARNING Energizing a Three-Shot Type XS Fuse Cutout damaged during transport and handling could result in serious death or injury. Examine the shipment for external evidence of damage as soon after receipt as possible, preferably before removal from the carrier s conveyance. Check the bill of lading to make sure shipping pallets and/or cartons are present. If there is visible loss and/or damage: 1. Notify the delivering carrier immediately. 2. Ask for a carrier inspection. 3. Note condition of shipment on all copies of the delivery receipt. 4. File a claim with the carrier. If concealed damage is discovered: 1. Notify the delivering carrier within 15 days of receipt of shipment. 2. Ask for a carrier inspection. 3. File a claim with the carrier. Also notify S&C Electric Company in all instances of loss and/or damage. NOTICE To prevent damage during transport and handling, keep the Three-Shot Type XS Fuse Cutout in its carton until you are ready to install it. S&C Instruction Sheet 351-501 5

Installation Mounting the Three-Shot Type XS Fuse Cutout The following steps describe how to mount the Three-Shot Type XS Fuse Cutout: Step 1 Attach the fuse cutout to a suitable mounting bracket as illustrated in Figure 1. Note: A mounting bracket suitable for cross-arm, pole, or wall mounting is furnished only if so specified on the order form by adding suffix -B or -C to the catalog number of the fuse cutout. External tooth washer Carriage bolt Pressure washer Step 2 Mount the fuse cutout on the mounting bracket, as shown in Figure 1, with the carriage bolt nut snug but loose enough for a pivot adjustment. Note the placement of the external tooth lockwasher between the Three-Shot Type XS Fuse Cutout center insert and the mounting bracket. See Figure 1. Step 3 Pivot the fuse cutout to a position that will provide maximum ease of operation, and securely tighten the carriage bolt nut. Mounting bracket Fuse cutout center insert Figure 1. Detail of attachment of Three-Shot Type XS Fuse Cutout to mounting bracket. Step 4 Make electrical connections. Be sure to wire-brush any aluminum conductors and apply a coating of oxidation inhibitor before inserting such conductors into the Three- Shot Type XS Fuse Cutout connectors. Tighten connector hardware to 20 ft.-lbs. Installing the Fuse Link Three-Shot Type XS Fuse Cutouts Without an Arc-Shortening Rod The following steps describe how to install the fuse link for a Three-Shot Type XS Fuse Cutout without an arcshortening rod: Step 5 Hand tighten the removable contact button on the fuse link by rotating clockwise, and carefully straighten the cable. Step 6 Remove the cap from the upper ferrule of the fuse-tube assembly. Slide the fuse link by rotating clockwise, cable end first, into the top of the fuse-tube assembly, and retrieve it at the lower end. 6 S&C Instruction Sheet 351-501

Installation Step 7 Replace the fuse-tube cap on the fuse-tube upper ferrule and tighten the cap securely using a wrench. Loosen the cable clamping nut on the trunnion. See Figure 2a. Step 8 Rotate the flipper fully about its pivot until it reaches its stop (firm resistance is felt). See Figure 2a. Hold the flipper in this position, and feed the cable through the flipper channel and around the threaded stud in a clockwise direction, as shown in Figure 2b. Maintain tension on the fuse-link cable, and firmly tighten the cable clamping nut using a wrench. Do not overtighten the cable clamping nut. Step 9 Clip excess cable to within a ½ inch (13 mm) of the nut. See Figure 2b. Cable clamping nut Flipper Bottom of fuse tube Three-Shot Fuse Type XS Cutouts With Arc-Shortening Rod Fuse cutouts having an arc-shortening rod that requires the use of removable buttonhead fuse links. Follow these steps for installation: Step 10 Remove and discard the contact button (and washer, for fuse links so equipped), and carefully straighten the cable. Trunnion Fuse link cable Figure 2a. Installing the fuse link into the fuse tube. Step 11 Unscrew the cap on the upper ferrule of the fuse-tube assembly, and retract the arc-shortening rod (attached to the cap). Fuse link cable Flipper channel CAUTION Do not use a standard cap in place of a cap with an arcshortening rod. Use of the arc-shortening rod is required to achieve the full interrupting rating. Failure to use the proper cap could result in misoperation of the unit. Cable clamping nut Step 12 Screw the arc-shortening rod onto the fuse link and hand tighten. Slide this assembly, cable first, into the top of the fuse tube, and retrieve the cable at the lower end. Continue with Steps 7, 8, and 9 above. Trunnion Figure 2b. Cable under tension around cable clamping nut. S&C Instruction Sheet 351-501 7

Installation Installing and Closing the Fuse Tubes WARNING Hot gases and fuse link particles can be expelled at high velocity during interruption. When closing a Three-Shot Fuse Cutout, all personnel should be positioned well clear of its exhaust. Following are the steps required to install and close the fuse tubes: Step 13 After installing the fuse link, as described in the previous sections, insert the hookstick prong into the opening under the trunnion casting band. Or, as an alternative, insert the prong in the keyhole opening in the trunnion casting band. Figure 3a. Installing the first fuse tube. Step 14 Guide the first fuse tube into its hinge located at the left end of the Three-Shot Fuse Cutout and aligned with the Number 1 label of the mounting lower cap. See Figure 3a. Leave the fuse tube hanging from the hinge without closing it. Step 15 Install the second and third fuse tubes in a similar fashion in their corresponding hinges, as indicated in Figures 3b and 3c, respectively. Figure 3b. Installing the second fuse tube. Step 16 Insert the hookstick prong into the pull-ring on the upper ferrule of the fuse tube, and swing the fuse tube to within approximately 45º of the fully closed position. See Figure 4a. Then, while looking away from the Three-Shot Fuse Cutout, drive the fuse tube to the closed position using a vigorous thrust. Carefully disengage the hookstick prong, taking care to avoid opening the fuse tube. Figure 3c. Installing the third fuse tube. Figure 4a. Closing the first fuse tube. 8 S&C Instruction Sheet 351-501

Installation Step 17 To close fuse tubes in positions 2 and 3, repeat the procedure described in Step 16 on page 8. See Figures 4b and 4c. Step 18 After all three fuse tubes are closed in, make sure the yellow side of the resetting ring points to Position 1 in the lower cap of the equipment. See Figure 8 on page 10. If necessary, insert a distribution prong into the resetting ring and turn the resetting ring until its yellow end reaches Position 1 in the Three-Shot Fuse Cutout lower cap. See Figure 7 on page 10. Restoring the Three-Shot Cutout When Three Fuse Tubes Have Dropped Open Use the following steps to restore the Three-Shot Type XS Fuse Cutout when three fuse tubes have dropped open: Figure 4b. Closing the second fuse tube. Step 19 Remove the first dropped-open fuse tube from the Three- Shot Fuse Cutout mounting for the first fuse tube. See Figure 5. The second and third fuse tubes are removed in a similar fashion. Figure 4c. Closing the third fuse tube. Figure 5. Removing the fuse tube when the fuse tube has dropped open. S&C Instruction Sheet 351-501 9

Installation Step 20 Replace the fuse link in each fuse tube as indicated in the Installing the Fuse Link section on pages 6 and 7. Step 21 Insert the first fuse tube and close it as indicated in the Installing and Closing the Fuse Tubes section on pages 8 and 9. Step 22 Insert the second and third fuse tube, and close them, as indicated in the Installing and Closing the Fuse Tubes section on pages 8 and 9. DANGER DO NOT move the resetting ring before installing and closing the Position 1 fuse tube. Failure to install and close the Position 1 fuse tube before moving the resetting ring will cause electrical arcing that may result in serious damage to the cutout and protected equipment, as well as death or serious injury to operating personnel. Figure 6. Inserting hookstick prong into resetting ring. Step 23 Insert a distribution prong into the resetting ring. See Figure 6. Turn the resetting ring until its yellow end reaches Position 1 in the Three-Shot Fuse Cutout lower cap. See Figure 7. Figure 8 shows how the unit appears when it is properly reset. Restoring the Three-Shot Cutout When Two Fuse Tubes Have Dropped Open The following steps describe how to restore the Three-Shot Type XS Fuse Cutout when two fuse tubes have dropped open: Figure 7. Turning resetting ring to position 1. Step 24 Remove the two dropped-open fuse tubes from the Three- Shot Fuse Cutout Mounting. See Figure 5 on page 9. Step 25 Replace the fuse link in both fuse tubes. See the Installing the Fuse Link section on pages 6 and 7. Step 26 Insert the first fuse tube in the mounting, and close it. See the Installing and Closing the Fuse Tubes section on pages 8 and 9. Figure 8. Indication of properly reset unit. 10 S&C Instruction Sheet 351-501

Installation Step 27 Insert the second fuse tube and close it. See the Installing and Closing the Fuse Tubes section on page 8 and 9. DANGER DO NOT move the resetting ring before installing and closing the Position 1 fuse tube. Failure to install and close the Position 1 fuse tube before moving the resetting ring will cause electrical arcing that may result in serious damage to the cutout and protected equipment, as well as death or serious injury to operating personnel. Step 28 Insert a distribution prong into the resetting ring. See Figure 6 on page 10. Turn the resetting ring until its yellow end reaches Position 1 in the Three-Shot Fuse Cutout lower cap. See Figure 7 on page 10. Restoring the Three-Shot Cutout When One Fuse Tube Has Dropped Open The following steps describe how to restore the Three-Shot Type XS Fuse Cutout when one fuse tube has dropped open: Step 29 Remove the dropped-open fuse tube from the Three-Shot Fuse Cutout Mounting. See Figure 5 on page 9. Step 30 Replace the fuse link in the fuse tube. See the Installing the Fuse Link section on page 6. Step 31 Insert the fuse tube in the mounting and close it. See the Installing and Closing the Fuse Tubes section on pages 8 and 9. DANGER DO NOT move the resetting ring before installing and closing the Position 1 fuse tube. Failure to install and close the Position 1 fuse tube before moving the resetting ring will cause electrical arcing that may result in serious damage to the cutout and protected equipment, as well as death or serious injury to operating personnel. Step 32 Insert a distribution prong into the resetting ring. See Figure 6 on page 10. Turn the resetting ring until its yellow end reaches Position 1 in the Three-Shot Fuse Cutout lower cap. See Figure 7 on page 10. S&C Instruction Sheet 351-501 11

Installation Opening the Fuse Tube DANGER Do not attempt to open S&C Three-Shot Type XS Fuse Cutouts to interrupt load current without the use of a loadbreak tool such as Loadbuster S&C s Loadbreak Tool. An arc started by opening a fuse cutout under load without a loadbreak tool could damage the equipment and result in death or serious injury. Loadbuster The S&C Loadbreak Tool is ideally suited for use in opening the fuse tube of S&C Three-Shot Type XS Fuse Cutouts (or other fuse cutouts and disconnects designed for use with the tool). The Loadbuster tool is S&C s unique method of providing low-cost, positive, and convenient live-switching capability for such devices. Instructions for use of the Loadbuster tool with S&C Three- Shot Type XS Fuse Cutouts are shown on pages 13 and 14. Following an opening operation using the Loadbuster tool, the fuse tube can be lifted out of the fuse cutout hinge using the prong of a hookstick. See Figure 3a on page 8. NOTICE S&C Three-Shot Type XS Fuse Cutout fuse tubes already installed should not be left in the open position for an extended period of time. Doing so could cause water damage to the tube lining. 12 S&C Instruction Sheet 351-501

Operation Operating with Loadbuster The S&C Loadbreak Tool Check for proper resetting of the Loadbuster tool by extending it about three inches by hand. Throughout this travel, an increasing spring resistance should be felt. Use the following steps to operate Loadbuster The S&C Loadbreak Tool: Step 33 Reach across in front of the Three-Shot Fuse Cutout with the Loadbuster tool and hook the anchor, located at the top of the tool, over the attachment hook on the far side of the fuse tube you wish to open. See Figure 9. Step 34 Swing the Loadbuster tool toward the fuse tube, and pass the tool s pull-ring hook through the pull-ring on the fuse tube. The pull-ring latch will deflect and, upon complete entry of the pull-ring, will spring back, locking the Loadbuster tool to the pull-ring. The tool is now connected across the upper contact of the Three-Shot Fuse Cutout. See Figure 9. Step 35 To open the circuit, operate the Loadbuster tool with a firm, steady pull until it is extended to its maximum length. See Figure 10. Avoid jerking and hesitation. The resetting latch will keep it open. Generally, there will be no indication of circuit interruption, but commutation arcing may be noted at the pull-ring hook and at the anchor, particularly when interrupting load currents are approaching the rating of the tool. The only sound will be that of the Loadbuster tool tripping. Figure 9. Loadbuster tool connected to S&C Three-Shot Type XS Fuse Cutout, Outdoor Distribution. Figure 10. Loadbuster tool in tripped position. S&C Instruction Sheet 351-501 13

Operation Step 36 To detach the Loadbuster tool after circuit interruption, first raise it slightly, and disengage the anchor from the attachment hook. Next, bring the fuse tube toward its fully open position. See Figure 11. Remove the Loadbuster tool from the pull-ring by turning the pole. This will deflect the pull-ring latch to release the pull-ring. Because the fuse tube will drop fully open by gravity, it may be preferred to remove the Loadbuster tool by rolling it off both the attachment hook and pull-ring at the same time merely by twisting the pole after the tool has been tripped and fully extended. To perform this operation easily and smoothly, always roll the Loadbuster tool so that it rotates in an upward direction. Step 37 To reset the Loadbuster tool for the next operation, hold as shown in Figure 12. Extend the tool slightly, and lift the resetting latch with the thumb. With the latch up, telescope the tool completely so the trigger can reset itself. Check for proper resetting by extending the tool about three inches. Throughout this travel an increasing spring resistance should be felt. Figure 11. Detaching the Loadbuster tool from Three-Shot Fuse Cutout. Resetting latch Figure 12. Resetting the Loadbuster tool. 14 S&C Instruction Sheet 351-501