Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Similar documents
Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 3100

Hydro-Flow Model 2300 Installation and Operation Guide B

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Low Profile Insertion Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

F-2600 SERIES INLINE VORTEX FLOW METER

Hot Tap Insertion Vortex

VIM20 Vortex Insertion Flowmeter

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Transmitting Transducer. Gas/Air Velocity Range:

Model FVP General Specification. Flanged Vortex Plate. Product Features

Vortex Eggs Delta Flowmeter

F-2500 SERIES VORTEX METER

VLM20 In-line Vortex Flowmeter

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

VIM20 Vortex Insertion Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

SIGNET 7002 Vortex Flow Sensor ENGLISH

Signet 7000/7001 Vortex Flow Sensors * *

1100 Series Piston Type Differential Pressure Gauges

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Signet 2517 Brass Paddlewheel Flow Sensor * *

Vortex In Line Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

VORTEX IN-LINE FLOW METERS

Chapter Page. 1 Introduction Description 1

Model 1000 Vortex Meter

Model 5000 Vortex Meter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

VIM20 Vortex Insertion Flowmeter

Vortex Plate. Model VP General Specification. Product Features

Vortex In Line Flow Meter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Multivariable Vortex Flow Meter

INSERTION flow sensor for continuous flow measurement

RCM - Direct Reading Flowmeters

F-1500 SERIES INSERTION TURBINE FLOW METER

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Multivariable Vortex Flow Meter

Model 124 Filter Minder & Model 124

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

TS , -850 Series TS , -850 Series TS-57031, TS

Appendix. Clearance. Skewed profiles. Application Schematics

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

UTM10 Series Ultrasonic Transit-time Flowmeters

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

RIM20 Rotor Insertion Flowmeter

DW PADDLE-BELLOWS FLOWMETER & SWITCH

MS Application. Features. Proportional Valve Actuator General Instructions

SIGNET Vortex Flow Sensors ENGLISH

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

A Member of the. Integrated Metering Technologies

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

G2 Industrial Grade Meters

Octave Water Meter Installation Manual

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

TURBINE FLOW METER SELECTION GUIDE

LTX RF LEVEL SENSOR. Instruction Manual

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

BI-DIRECTIONAL INSERTION METER

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

A Member of the. Integrated Metering Technologies

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Tracer VM with User Interface

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Model DFX Doppler ultrasonic flow meter

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

RCM. Direct Reading Flowmeter. for Liquids or Gases

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500

mass flowmeter for compressed air

Liquid Turbine Flowmeter

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

8000 Series Liquid Flow Meters

TX 115/215 Hot-tap Insertion Turbine Instructions

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Transcription:

Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing: Model 00.. 5 Dimensional Drawing: Condulet. 5 Mechanical Installation. 5 6 Electrical Installation 7 Technical Data. 8 MODEL AND SUFFIX CODES Category Type Description L ine Size " thru 0" (50 mm-500mm) Mounting Output Display Measuring Units Suffix Codes F ixed Inserttion 00 Thread-o-let Saddle for Steel Pipe Saddle for PVC Pipe Tee (" and " only) None (Retrofit) Pulse Current, 4-0 ma No Output For Use With Solar Power Supply (Low power consumption - ma) No Display Rate/Total Display English Metric Example: Hydro-Flow-00-08---- 0 thru 0 4 5 4 An 8" fixed insertion flowmeter with saddle mounting for PVC pipe, pulse output and a rate/total display with English measuring units. Notes:. Standard English measuring units for flow rate and totalized flow are gallons per minute (gpm) and gallons, respectively. Standard metric measuring units for flow rate and totalized flow are cubic meters per hour (m /hr) and cubic meters (m ), respectively. Please specify other desired measuring units for which the flowmeter should be configured. Other units, such as acre-feet, cubic feet, barrels and liters are available and can be set by the factory.. Please specify pipe size, material and schedule OR outside and inside diameter of pipe. 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com

Theory and Identification What is a Vortex Flowmeter? Vortex shedding flowmeters measure flow by detecting the frequency at which vortices are alternately shed from a bluff body. The vortices create low and high pressure zones behind the bluff body which are detected as a force acting on the sensor wing. This force is transmitted through the sensor wing to the Hydro-Flow piezo-resistive sensor mounted inside the flow line. Hydro-Flow's unique and proprietary microprocessor based piezo-resistive sensor can accurately and reliably process vortex signals 5 times smaller than permitted by other technologies. According to well proven physical laws, the shedding frequency is directly proportional to the average flow velocity. This effect can be observed in the fluttering of a flag. Vortex flowmeters are preferred for many applications requiring wide flow range, accuracy, and reliability (no moving parts). When You Receive the Flowmeter Upon receiving your Fluidyne equipment, verify that all materials on the packing list are present. Check for possible shipping damage and notify the freight carrier or your Fluidyne representative if there is any damage. A permanent identification plate (ID) is attached to your flowmeter; verify the model is consistent with your requirements. (See Model & Suffix Code Table, p..) 4604 Made in the U.S.A. 00-04---- For example, if you ordered a 4" Hydro-Flow 00 flowmeter with a thread-o-let fitting, 4-0 ma analog output and a Rate/ Total display with English measuring units, the model number should read 00-04----, as in the above ID. Common Sense / Meter Handling Issues You are in receipt of a precision, world-class instrument. Even though the flowmeter is one of the most rugged in the industry, exercise reasonable care with the flowmeter.. When not installed, store the flowmeter with the installation manual in its shipping container.. Do not ram or poke objects into the meter bore or onto the sensor wing/shedder. Hydro-Flow is a no moving parts flowmeter. If you push hard enough to see a part move, the flowmeter is probably damaged.. Pay particular attention to the direction of flow. The flow must impact the surface of the stainless steel shedder. The direction of the flow is clearly indicated on the flowmeter electronics. The flowmeter will not work if you install it backwards. 4. The flowmeter's installation location is important for optimum performance accuracy; a quick review of Installation Guidelines, p. 4, will be helpful. 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com

Installation Guidelines Selecting the Best Flowmeter Location Not all plumbing is laid out with flowmetering in mind. For optimum performance, you must consider straight run requirements and the flowmeter's installation location relative to flow direction. Figures and illustrate useful examples of both proper and improper flowmeter installations. If you have special requirements, PLEASE consult the factory. Flowmeter Location Figure illustrates possible flowmeter locations. The good flowmeter locations are recommended to ensure that the pipe and the flowmeter will always be filled with fluid. Straight Run Requirements Figure illustrates the minimum requirements for straight run piping. Note: The straight run of the pipe must have the same nominal diameter (D) as the fl ow-meter body. Figure. Flowmeter Location Figure. Straight Run Requirements Bad Bad h h>0 h h>0 Bad 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com 4

Mechanical Drawing: Model 00 Dimensional Drawing: Condulet (shown with display) Dimensions in inches (mm) Mechanical Installation General Mechanical Installation Information The Hydro-Flow Model 00 is a fixed insertion flowmeter with a /" NPT mounting thread. The pipe must be de-pressurized prior to flowmeter installation and/or removal. Three standard accessory mounting fittings are recommended for flowmeter installation.. Thread-o-let: The thread-o-let is recommended for permanent installation requiring minimal service and is good for high-pressure (up to 400 psi) applications.. Saddle Clamp: The saddle clamp is recommended when welding is not feasible. Saddles can be used for steel and PVC pipe. Pressure is limited to 00 psi.. Tee Fitting: The tee fitting is installed only for " and " pipe sizes. Installation requires no special machining, hole cutting or welding. Pressure is limited to 50 psi. 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com 5

Mechanical Installation (continued) Figure. Thread-o-let Installation Figure 5. Depth Stop Installation Tool Thread-o-let Installation. Drill or bore and de-burr a.875" diameter hole in pipe. Use a 7 /8" hole saw. Caution: Flame cutting is discouraged.. Center the thread-o-let over hole. (See Figure.). Weld the thread-o-let onto the pipe using standard trade practices. Trade practices may vary by locality. Welding should be done by an experienced certified welder. Saddle Clamp Installation. Drill or bore and de-burr a.875" diameter hole in pipe. Use a 7 /8" hole saw. Caution: Flame cutting is discouraged.. Clean pipe surface thoroughly -- particularly in the area where the gasket will sit. Check saddle gasket for proper positioning in saddle body. (See Figure 4 below.). Lubricate pipe and face of gasket with soap and water. Add antifreeze in freezing weather. Mount saddle body with gasket in place on pipe. 4. Install bales and washers on open lug side. 5. Tighten nuts evenly until saddle body conforms snugly to the pipe. Figure 4. Steps thru 5 for Saddle Clamp Installation Figure 6. Using the Tool Figure 8. Flow Direction and Alignment Tee Fitting Installation. Apply sealant to pipe threads on the pipe upstream from the flowmeter. Thread brass tee fitting to the pipe.. Apply sealant to pipe threads on the pipe downstream from the flowmeter. Thread pipe to brass tee fitting. Flowmeter Installation. Install mounting hardware. (See above installation instructions.). Apply sealant to flowmeter's /" NPT connection fitting threads. Insert the flow sensor CAREFULLY into the pipe through the threaded port. The flowmeter will slide freely thru the compression fitting. Caution: DO NOT let the fl ow sensor hit the interior of the pipe wall by allowing it to "fall" into the pipe. Tighten flowmeter's /" NPT connection fitting.. Place the depth stop installation tool (See Figure 5) between the pipe and underside of elctronics enclosure as shown for correct pipe size. (See Figure Figure 7. 6.) For tee fittings only, place tool on the "lip" of the tee fitting. (See Figure 7.) Hand tighten the compression fitting until there is frictional resistance to movement. Wrench tighten /4 turns to swage the pressure seal. 4. The insertion depth (movement of sensor in and out of pipe) is fixed. Loosen the compression fitting until the sensor and electronics enclosure rotate freely. Visually align the flow sensor with respect to the axis of the pipe by rotating the flowmeter until the edge of the electrical housing is parallel to the pipe axis and the indicator arrow is pointing in the direction of flow. (See Figure 8.) Lock the compression fitting. 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com 6

Electrical Installation TABLE. CURRENT LIMITING RESISTOR FOR PULSE OUTPUT Supply Voltage (DC) Current Limiting Resistor Values (ohms) Min Max 0 400 400 480 800 4 560 00 6 640 600 CAUTION The pulse output of the Hydro-Flow flowmeter functions by momentarily shorting the + terminal to the terminal. If the flowmeter is connected directly to a DC power source without the series resistor, both the flowmeter and the power source may be damaged. The wiring polarity must be observed for proper operation of the flowmeter. If the flowmeter is wired backwards to the current-limited power source, the flowmeter will not be damaged but it will not function properly. Pulse Output Electrical Installation The Hydro-Flow pulse output flowmeter may be used with a 0 to volt DC power supply and series current limiting resistor. The voltage at the flowmeter terminals is internally limited to 8.0 ±.0 volts DC under no-flow conditions, dropping to less than.0 volt for the.5 to 5 millisecond duration of the output pulse. Figure 4 below illustrates a typical installation. Note: The totalizer or fl ow computer input must be rated for an 8-volt pulse input. Figure 9. Wiring Diagram - Pulse Ouput 8 70 000 0 800 400 880 800 4 960 00 6 040 600 8 0 4000 0 00 4400 80 4800 Graph. Maximum Load Resistance for 4-0 ma Ouput The cable may be up to 000 feet of #0 AWG or larger shielded two-conductor cable. The shield lead from the meter may be connected to an earth ground, such as a copper cold water pipe. The shield improves noise immunity and provides a return path for electrical surges. Its use is optional in installations in which electrical transients and noise are not a problem. The current limiting resistor is required to limit the normal operating current in the flowmeter to a value between 5 and 0 ma with a meter voltage of 8 volts, and less than 5 ma with the meter terminals short-circuited. The value of the resistor is determined from the power supply voltage, the operating meter current and the cable resistance. Table lists standard / watt 5% resistor values which will work in most installations. For power supply voltages between those in the table, use the lower value of resistor. 4-0 ma Current Output or No Output (Display Only) Electrical Installation The flowmeter may be connected with up to 000 feet of # AWG or larger cable. Shielded cable may be necessary in some environments to reduce electrical noise; if used, the shield should be connected at one end only to an earth ground point, such as a copper cold water pipe. Figure 0. Wiring Diagram - 4-0 ma Current Loop 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com 7

Technical Data Mechanical Specifications Type Fixed Insertion Measurable Fluids Water; Water-Glycol Mixtures; Condensate Pipe Sizes " to 0" (50 to 500 mm) Fluid Temperature to F (0 to 00 C) for all connections Fluid Pressure 400 PSI (7.5 bar) maximum for T.O.L. 00 psi (0.7 bar) maximum for saddle connection 50 psi (0. bar) maximum for tee connection Ambient Temperature -0 to 40 F (-9 to 60 C) Flow Range 0.5 feet, or 0.5 meters, per second minimum 5 feet, or 4.5 meters, per second maximum Measuring Units English..Gallons MetricCubic Meters Other measuring units available upon request or measuring units can be reconfigured using Fluidyne's Field-Pro, PC compatible configuration software. Accuracy (Combined Linearity and Repeatability) ±.0% of full scale Wetted Parts Vortex Sensor.Ultem (Plastic) Shedder Bar.6 Stainless Steel Stem Aluminum O-rings..EPDM Compression Fitting Brass Mounting Options Carbon steel saddle for steel or PVC pipes Carbon steel thread-o-let Brass tee fitting Pipe Connection /" NPT Straight Run Piping Typical 0 diameters upstream, 5 diameters downstream. (See Figure, p.4.) Electrical Specifications Enclosure Reinforced Polycarbonate, NEMA 6 European CE Mark Approved Output Signal Options Pulse Output Frequency proportional to flow rate. Power Supply: 0- VDC power supply with current limited by series resistance to between 5 and 0 ma. Maximum pulse width is 5 ms. See Table for standard output scaling. Other pulse output setting can be precon-figured by the factory or reconfigured in the field using Fluidyne's Field-Pro. Analog Output 4-0 ma analog current loop, current proportional to flow rate. Power Supply: 0- VDC compliance. 4 ma = zero flow; 0 ma = maximum flow listed in Table. Other 0 ma setting can be precon-figured by the factory or reconfigured in the field using Fluidyne's Field-Pro. No Output.Display only. Power Supply: 8- VDC, 4 ma maximum. Display Option LCD display alternately shows 4-digit rate and 8-digit total flow. TABLE. MINIMUM AND MAXIMUM RANGES Line Size in. (mm) Min. Flow Max. Flow (gpm) Min. Flow Max. Flow ( m /h) (50) 5. 60. 6. (80).7 50.7 79.5 4 (00) 0.0 600 4.6 6. 6 (50) 50.0 500.4 40.7 8 (00) 8. 500 9.0 556.8 0 (50). 4000 0. 908.5 Pulses/gal ) 50 5 5 6 4 Pulses/m ) 5,000 6,000 5,000,000,000 500 Line Size in. (mm) Min. Flow Max. Flow (gpm) Min. Flow Max. Flow ( m /h) (00) 84 5500 4.7,49. 4 (50) 09 650 47.4,49.5 6 (400) 84 8500 64.4,90.6 8 (450) 67,000 8.,498.4 0 (500) 467 4,000 06,79.7 Pulses/gal ) 0. 5 Pulses/m ) 500 500 00 00 00. When flowmeter is configured for pulse output. P/N 99060 Rev. F (/00) 600 Diagonal Highway, Longmont, CO 8050 Tel: (0) 65-05 Fax: (0) 678-754 e-mail: fluidyne@emcoflow.com 8