Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Similar documents
Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Application Mini Contactors for Motors and Resistive Loads

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Application Mini Contactors for Motors and Resistive Loads

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

PKZ and PKE motor-protective circuit-breakers

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

CA Z-EN Overload relays, CT-operated overload relays

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

AF40... AF96 3-pole contactors Technical data

46.3 LS-Titan Miniature DIN Switches LS-Titan Safety Interlock Switches

Flexible. Intelligent. Trendsetting.

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relay EF65, EF96 and EF146

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relays EF205 and EF370

ASL09..S 3-pole Contactors - Spring Terminals

Thermal overload relay TF65 and TF96

Cylindrical fuse-link

MS25, MST25, MS20, MST20

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

MS General Information Extended Product Type: MS

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

IEC CONTACTORS AND OVERLOAD RELAYS

3 - Protection components Motor circuit-breakers

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

TAE pole Contactors

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

Thermal Overload Relays

Short form catalogue. Motor protection & control

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Control Circuit Protection

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AE 9... AE 40 Contactors NE... Contactor Relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Technical Data Accessories MCBs Ex9B.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Bulletin 193-T1 Bimetallic Overload Relays

Protection Equipment

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

BETA Switching Switches and Light Indicators

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Technical data for manual motor starters Type MS325

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

ZS4-SF1 Screw Clamp Terminal Block

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Electrical sector solutions E Line family. Industry leading design in a compact package

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

1.1. Reduced Voltage Motor Starters

4 - Miniature controls

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Electrical sector solutions E Line family. Industry leading design in a compact package

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Safety rope switch with reset for emergency stop

B Mini Contactor V Hz

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Manual Motor Starter MS 116. Technical Catalogue

Manual motor starter MS132

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Star Series Motor protection & control

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

SIRIUS 3RU2 Thermal Overload Relays

MC FRAME SIZE 1 / UP TO 160A

Manual Motor Starters. Meta-MEC

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

and other modular devices for low voltage installation

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

46.3. Limit Switches. Contents. LS-Titan Miniature DIN Switches. LS-Titan Miniature DIN Switches

Transcription:

Break,CageClamp,Front Partno. M22-CK01 Articleno. 216385 CatalogNo. M22-CK01Q Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4 Single unit/complete unit Element Connection technique Spring-loaded terminals Fixing Front fixing Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany Contacts N/C = Normally closed 1 NC Notes = safety function, by positive opening to IEC/EN 60947-5-1 Contact sequence 12/05/2013 HPL-ED2013 2.10 EN 1 / 5

Contact sequence Contact travel diagram, stroke in connection with front element Configuration Protection type IP20 Connection to SmartWire-DT no Connection type Single Description of HIA trip-indicating auxiliary General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current. Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary can be clipped into the circuit-breaker. Can be used with NZM4 circuit-breaker: up to two standard auxiliary s can be clipped into the circuit-breaker. Any combinations of the auxiliary types are possible. Not in combination with switch-disconnector PN Marking on switch: HIA Labeling in FI-Block: HIAFI. If the trip-indicating auxiliary switch in the fault current block is used, the NC s operates as a N/O and the NC operates as an N/O. Description standard auxiliary HIN Switching with the main s Used for indicating and interlocking tasks. Can be used with NZM1 circuit-breaker: a standard auxiliary can be clipped into the circuit-breaker. Can be used with NZM2 size circuit-breaker: a standard auxiliary can be clipped into the circuit-breaker. Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary s can be clipped into the circuit-breaker. Any combinations of the auxiliary types are possible. Marking on switch: HIN. On combination with remote operator NZM-XR... the right mounting location of standard auxiliary HIN can be fitted only with individual s. For use with NZM1(-4), 2(-4), 3(-4), 4(-4) PN1(-4), 2(-4), 3(-4) N(S)1(-4), 2(-4), 3(-4), 4(-4) Notes The following applies for the std. pack: M22-(C)K : Std. pack = 20 off Approvals Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection UL/CSA Type: - 12/05/2013 HPL-ED2013 2.10 EN 2 / 5

General Standards IEC/EN 60947 DE 0660 Lifespan, mechanical Operations x 10 6 > 5 Operating frequency Operations/ h 3600 Actuating force n Operating torque (screw terminals) Nm 5 0.8 Protection type IP20 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature C Open C - 25 - + 70 Mounting position As required Mechanical shock resistance g 30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 Terminal capacities mm 2 Solid 2 mm 0.75-2.5 Stranded 2 mm 0.5-2.5 Contacts Rated impulse withstand voltage U imp 6000 Rated insulation voltage U i 500 Overvoltage category/pollution degree III/3 Control circuit reliability at 24 DC/5 ma H F Fault probability < 10-7 (i.e. 1 failure to 10 7 operations) at 5 DC/1 ma H F Fault probability < 5 x 10-6 (i.e. 1 failure in 5 x 10 6 operations) Max. short-circuit protective device Fuseless Type PKZM0-10/FAZ-B6/1 Fuse gg/gl A 10 Switchingcapacity Rated operational current I e A -15 DC-13 115 I e A 6 220 230 240 I e A 6 380 400 415 I e A 4 500 I e A 2 42 I e A 1.7 60 I e A 1.2 110 I e A 0.8 Lifespan, electrical -15 D-13 230 /0.5 A Operations x 10 6 1.6 230 /1.0 A Operations x 10 6 1 230 /3.0 A Operations x 10 6 0.7 12 /2.8 A Operations x 10 6 1.2 Auxiliarys Rated operational voltage U e 12/05/2013 HPL-ED2013 2.10 EN 3 / 5

Rated operational voltage Ue Rated operational voltage, max. Ue DC 500 220 Conventional thermal current Ith=Ie CSA 4 Rated operational current I e A Differentratedoperationalcurrents when used as auxiliary for NZM circuit-breaker M22- K... M22- CK... bei = 50/60 Hz Bemessungsbetriebsstrom -15115 Ie A 4 4 4 230 Ie A 4 4 4 400 Ie A 2-2 500 Ie A 1-1 DC-1324 Ie A 3 3 3 42 Ie A 1.7 1 1.5 60 Ie A 1.2 0.8 0.8 110 Ie A 0.8 0.5 0.5 220 Ie A 0.3 0.2 0.2 XHI Short-circuit protection max. fuse A gg/ gl 10 Max. miniature circuit-breaker A FAZ-B6/B1 Operating times Terminal capacities mm 2 Solid or flexible conductor, with ferrule 2 mm 1 x (0.5-1.5) 2 x (0.5-0.75) Early-make time of the HI compared to the main s during with make and break switching. (switch times with manual operation): NZM1, PN1, N(S)1: ca. 20 ms NZM2, PN2, N(S)2: ca. 20 ms NZM3, PN3, N(S)3: ca. 20 ms NZM4, N(S)4: approx. 90 ms, the HI switch early Offswitching not forward. Other technical data (sheet catalogue) Maximum equipment and position of the internal accessories TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Auxiliary block (EC000041) Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss8-27-37-13-02 [AKN342009]) Number of s as change-over 0 Number of s as normally open Number of s as normally closed Rated operation current Ie at -15, 230 A 6 0 1 Type of electric connection Spring clamp connection Mounting method Front fastening Dimensions 12/05/2013 HPL-ED2013 2.10 EN 4 / 5

Pushbutton with M22-(C)K Pushbutton with M22-(C) LED + M22-XLED Additionalproductinformation(links) IL04716002Z(AWA1160-1745)RMQ-TitanSystem IL04716002Z (AWA1160-1745) RMQ- Titan System ftp://ftp.moeller.net/documentation/awa_instructions/il04716002z2013_08.pdf 12/05/2013 Eaton Industries GmbH http://www.eaton.eu 11/2013 by Eaton Industries GmbH HPL-ED2013 2.11 EN 5 / 5