Short-Circuit Current Rating - SCCR Watlow Power Controllers

Similar documents
BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Equipment Protection. Transformers 600V or Less

High Speed Fuses. Section Contents Page

WARNING Personnel and property must be protected against the consequence of component break-down internally in the frequency converter.

Ferrule fuses. High Speed Fuses

Harmonization of IEC and North American Safety Standards

Equipment Protection. Transformers 600V or Less

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Fuseology. High Speed Fuses

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

The easiest and fastest way to select and specify the right control circuit fuse

CUBEFuse. CUBEFuse catalog numbers (amps)

Fuseology. Dual-Element, Time-Delay Fuse Operation

Compact Circuit Protector (CCP) Application Note

A case study in solving SCCR issues

Low-Peak 600V Class RK1

Low Voltage Fuses For Motor Protection

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

BH-1 modular fuse blocks, 700 V, 400 A

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Products for enhancing electrical safety and reliability

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Low voltage, branch circuit fuses

The easiest and fastest way to select and specify the right fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

XT IEC Power Control Manual Motor Protectors

Power Switching Devices

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Installation and Construction Notes for EVSE4

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Specification made simple for selective coordination in a compact size

Quik-Spec Coordination Panelboard Specifications

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Synergy EN product information

N0N A 250V One-Time Class H Fuse

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

overvoltage solutions

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Bussmann series Quik-Spec Coordination Panelboard

Applying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery

1 Phase electronic contactor (SC 1)

Low Voltage, Branch Circuit Rated Fuses

Questions from the AHJ To Fuse or Not to Fuse?

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Design Standards NEMA

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Leadership in Circuit Protection

Selective Coordination Enforcement:

Compact Circuit Protector (CCP)

FUSES. Safety through quality

A. Submit manufacturer's literature and technical data before starting work.

Solar circuit protection application guide. Complete and reliable solar circuit protection

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Ω 1 Ω Supplementary Fuses

Application Note CTAN# 223

Leadership in Circuit Protection

Quik-Spec Electrical Gear

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Now - Up To 400A Mains!

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Compact Circuit Protector (CCP)

Bussmann series NH catalogue. Leadership in circuit protection

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

Electrical safety and reliability: Selective coordination. Protect with selective coordination

FLO Home TM G5 Model. Installation guide

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Fuse holders and fuses

AN INNOVATIVE ALTERNATIVE TO INDUSTRY STANDARDS

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

CPS 3Phs String Inverters NEC 2014 Compliance

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Electrical Safety and Overcurrent Protection

Quick Start Guide TS 910 & TS 920

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Compact Circuit Protector (CCP)

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders

Assembly not available for new installations.

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Transcription:

Power Controllers Effective April, 2006 through UL508A, the National Electric Code (NEC ) requires that electrical panel assemblies be marked with the available fault current or Short- Circuit Current (). See Article 409.110 of the 2008 edition of NEC. The rating must be marked on all industrial electrical panels and will be rated at the level of the lowest component. What Is Short-Circuit Current ()? is a safety consideration that gives a rating, that a circuit or piece of equipment will survive without producing a dangerous arc flash. An arc flash results in an explosion caused by an insulation failure or air ionization from an over voltage event. An arc flash with 1,000 amperes or more can cause substantial damage, fire or injury. The massive energy released in the fault rapidly vaporizes the metal conductors involved, blasting molten metal and expanding plasma outward with extreme force. The reason behind the code change is to prevent fire, injury or death. The rating represents the maximum level of short-circuit current that the component or assembly can withstand and is used for determining compliance with NEC Article 110.10. Although this rating can be marked on individual components or assemblies the assembly rating takes into account all components contained within the equipment. Do not make the mistake to assume that the interrupting rating of the over current protective device protecting the circuit represents the for the entire circuit. Interrupting ratings apply solely to the over current protective device and are used for compliance with NEC Article 110.9. All industrial electrical systems have a known Fault Current which is available from the utility that serves the building. If the incoming power and the buss power are rated at 68,000 amps, then any new control panel installed in that area must have a rating of at least 68,000 amps. Every component within the power switching circuit must meet or exceed the available fault current where the panel is to be installed. If a device has not been tested for a, then the generic rating of 5,000 amperes is assigned for a switch (Silicon Controlled Rectifiers are switches). Most installed panel locations will require a higher rating than 5,000 A. Who Is Affected By The Markings? The 2005 NEC has requirements for anyone building UL508A listed equipment to be marked with an. Therefore facility, process and consulting engineers need to specify the correct equipment. Electrical contractors need to correctly install equipment and electrical inspectors need to ensure equipment compliance. What does this mean to you? If on-site power supply available fault current is higher than your panel rating, additional mitigation measures will be required in order to meet the lower rating of the electrical panel. See document references listed at the end of this white paper. This may mean installing a transformer on location to limit the available fault current. By selecting power components such as DIN-A-MITE, Power Series and Q-Pac which have been tested to 200,000 A; Aspyre products have been tested to 100,000 A; and EZ-Zone RM, PM and Flex modules have been tested to 10,000 A, the additional mitigation measures may not be required reducing the panel installation cost for you and your customer. Electric Manufacturing Co. 1 2009 Electric Manufacturing Company

Power Controllers has tested the following power controls for short-circuit current rating (). These devices have a rating of 200,000 amperes when used with the listed fuse in each hot leg. defaults to 5,000 amperes per UL508A guidelines and the United States National Electric Code (NEC ) with any other untested combination. fuses do not meet branch circuit requirements per NEC. The combination DFJ fuse does provide branch circuit protection and will protect the semiconductor device. Use either the and holder with branch circuit protection or the Bussmann Combination and Combination Holder. fuses do not provide branch circuit protection. Branch fuses or circuit breakers are required to protect the and the wire. The Short circuit current rating only applies with the exact fuse listed, or a smaller fuse of the same family. s are not valid at all unit voltages, see tables below for details. Holder Part * Combination * Holder for in No. Combination DIN-A-MITE A, B, C 20 A 17-8020 17-5110 FWC-20A10F DFJ-20 0808-0325-0020 0808-0326-1530 DIN-A-MITE A, B, C 25A 17-8025 17-5110 FWC-25A10F DFJ-25 No P/N 0808-0326-1530 DIN-A-MITE A 1, B, C 30 A 17-8030 17-5114 FWP-30A14F DFJ-30 0808-0325-0030 0808-0326-1530 DIN-A-MITE A 1, B, C 40 A 17-8040 17-5114 FWP-40A14F DFJ-40 0808-0325-0040 0808-0326-3560 DIN-A-MITE B 1, C 50 A 17-8050 17-5114 FWP-50A14F DFJ-50 0808-0325-0050 0808-0326-3560 DIN-A-MITE B 1, C 63 A 17-8063 17-5122 FWP-63A22F DFJ-60 0808-0326-0060 0808-0326-3560 DIN-A-MITE C 80 A 17-8080 17-5122 FWP-80A22F DFJ-80 J601001CR 0808-0325-0080 0808-0326-7010 DIN-A-MITE C 100 A 17-8100 17-5122 FWP-100A22F DFJ-100 J601001CR 0808-0325-0100 0808-0326-7010 DIN-A-MITE D 2, 3 65 A x 2 0808-0096-0000 Not Applicable 170N3437 Not Applicable Not Applicable 1 FPW series can be used up to this rating to protect the SCR. DFJ series cannot as it must follow the Branch circuit 125% rating rule. 2 DIN-A_MITE D uses two 65A fuses in parallel. 3 DIN-A_MITE D, Power Series and QPAC have on board semiconductor fuses. Electric Manufacturing Co. 2 2009 Electric Manufacturing Company

Power Controllers *The is equivalent to the Bussmann Part. Holder Part No. * Combination * Holder for Combination in Power Series 3 100 A 0808-0102-0100 Integral to unit 170M1317 Not Applicable Not Applicable Power Series 125 A 0808-0102-0125 Integral to unit 170M1318 Not Applicable Not Applicable Power Series 160 A 0808-0102-0160 Integral to unit 170M1319 Not Applicable Not Applicable Power Series 200 A 0808-0102-0200 Integral to unit 170M1320 Not Applicable Not Applicable Power Series 250 A 0808-0102-0250 Integral to unit 170M1321 Not Applicable Not Applicable Power Series 315 A 0808-0102-0315 Integral to unit 170M1322 Not Applicable Not Applicable QPAC 3 Qxx-xxx-150-xxx 200 A 17-7053 Not Applicable FWH-200A Not Applicable Not Applicable Qxx-xxx-200-xxx 250 A 17-7054 Not Applicable FWH-250A Not Applicable Not Applicable Qxx-xxx-300-xxx 400 A 17-7056 Not Applicable FWH-400A Not Applicable Not Applicable Qxx-xxx-400-xxx 500 A 17-7057 Not Applicable FWH-500A Not Applicable Not Applicable Qxx-xxx-500-xxx 600 A 17-7058 Not Applicable FWH-600A Not Applicable Not Applicable Qxx-xxx-600-xxx 800 A 17-7059 Not Applicable FWH-800A Not Applicable Not Applicable Qxx-xxx-800-xxx 1000 A 17-7082 Not Applicable 170M6714 4 Not Applicable Not Applicable Qxx-xxx-01K-xxx 1250 A 17-7081 Not Applicable 170M6766 4 Not Applicable Not Applicable 1 FPW series can be used up to this rating to protect the SCR. DFJ series cannot as it must follow the Branch circuit 125% rating rule. 3 DIN-A_MITE D, Power Series and QPAC have on board semiconductor fuses. 4 170M6764 indicator version allowed in place of 170M6714, 170M6716 non-indicator version allowed in place of 170M6766. Electric Manufacturing Co. 3 2009 Electric Manufacturing Company

Power Controllers Holder Part No. * Combination * Holder for Combination 0808-0326-1530 in max EZ-ZONE ST 25A 30 A 17-8030 17-5114 FWP-30A14F DFJ-30 0808-0325-0030 EZ-ZONE ST 25A 40 A 1 17-8040 17-5114 FWP-40A14F DFJ-30 is max size 125% rating 480 Vac~ EZ-ZONE ST 50A 50 A 17-8050 17-5122 FWP-50A22F DFJ-50 0808-0326-0050 0808-0326-3560 EZ-ZONE ST 50A 63 A 17-8063 17-5122 FWP-63A22F DFJ-50 is max size for I 2 T at 480V 480 Vac~ EZ-ZONE ST 50A 63 A 17-8063 17-5122 FWP-63A22F DFJ-60 0808-0326-0060 0808-0326-3560 EZ-ZONE ST 75A 80 A 17-8080 17-5122 FWP-80A22F DFJ-80 0808-0325-0080 EZ-ZONE ST 75A 90 A No FWP-90 DFJ-90 available No P/N EZ-ZONE ST 75A 100 A 17-8100 17-5122 FWP-100A22F DFJ-100 0808-0325-0100 J60100-1CR 0808-0326-7010 J60100-1CR 0808-0326-7010 J60100-1CR 0808-0326-7010 1 FPW series can be used up to this rating to protect the SCR. DFJ series cannot as it must follow the Branch circuit 125% rating rule. 200,000 DFJ fuse 240 Vac~ FWP fuse 480 Vac~ 200,000 DFJ fuse 240 Vac~ FWP fuse 480 Vac~ Definitions from EN 60947-4-3 Type 1 Protection - Coordination requires that, under short-circuit conditions, the device shall cause no danger to persons or to the installation and may not be suitable for further service without repair and replacement of parts. Type 2 Protection - Coordination requires that, under short-circuit conditions, the device shall cause no danger to persons or to the installation and shall be suitable for further use. When fused per the combinations listed above, products comply with Type 2 Protection. Electric Manufacturing Co. 4 2009 Electric Manufacturing Company

Power Controllers EZ-Zone RM Dual 10A SSR RMEx-KAKA-xxxx FMHA-KAAA-xxxx max Holder Part No. Branch 12.5A 17-8012 17-5110 FWC12A10F 5 Any Class CC fuse LP-CC, KTK-R, FNQ-R to rated current or 20A Branch Holder Part No. in Electric Manufacturing Co. 5 2009 Electric Manufacturing Company 0808-0235-0000 10,000 240 Vac When the fuse is used, complies with Type 2 Protection. When the Branch circuit fuse is used units comply with Type 1 Protection. EZ-Zone RM, PM No-arc 15A relay RMC outputs D,J or Y RMC-X_X_X_X_-XXXX PMXXXXH-XXXHXXX FMMA-XXHX-XXXX EZ-Zone RM, PM 5A Mechanical Relay PMXXXEJ-XXEJXXX RMC outputs B,F,G,H,J,K,L,M, or R RMC-X_X_X_X_-XXXX RMEX-JJJX-XXXX RMHX-XXJJ-XXXX RMSX-XXJ(J,B)-XXXX RMLX-XXJ(J,B)-XXXX FM(M,L)A-XEJX-XXXX FMHA-JAAA-XXXX EZ-Zone RM Quad 2A SSR output RMEX-LLLL-XXXX RMHX-XXLL-XXXX FMHA-LAAA-XXXX max 20A 7A fuse. Not tested with this output Not tested with this output 2.5A Not tested with this output Branch 5 Class CC fuse LP-CC, KTK-R, FNQ-R to rated current or 20A Branch Holder Part No. in 0808-0235-0000 10,000 240 Vac 5 NOTE: tested worst case 20A umbrella fuse based on wire size typically used in panels. While this fuse will provide the stated Type 1 Protection, it is suggested to use a fuse based on the NEC 125% rating of the.

Power Controllers UL 508 Section 52 High-Available Fault Current Tests ASPYRE Mfg and Part No. in DTxxx-(035 or 040)xx-xxxxx 50A 17-8050 Eaton Bussmann FWP-50A14F 100,000 A 600 Vac~ DTxxx-(060 or 090)xx-xxxxx 160A 0808-0363-0160 Siba 20 559 20.160 100,000 A 600 Vac~ DTxxx-120xx-xxxxx 180A 0808-0363-0180 Siba 20 559 20.180 100,000 A 600 Vac~ DTxxx-150xx-xxxxx 200A 0808-0363-0200 Siba 20 559 20.200 100,000 A 600 Vac~ DTxxx-180xx-xxxxx 250A 0808-0363-0250 Siba 20 559 20.250 100,000 A 600 Vac~ DTxxx-210xx-xxxxx 315A 0808-0363-0315 Siba 20 559 20.315 100,000 A 600 Vac~ DT1xx-300xx-xxxxx 350A 0808-0362-0000 Eaton Bussmann 350FM 100,000 A 600 Vac~ DT(2 or 3)xx-300xx-xxxxx 450A 0808-0357-0000 Eaton Bussmann 450FMM 100,000 A 600 Vac~ DT3xx-350xx-xxxxx or DTxxx-400xx-xxxxx 550A 0808-0358-0000 Eaton Bussmann 550FMM 100,000 A 600 Vac~ DT2xx-(450 or 500)xx-xxxxx 315A (2 per leg) 0808-0360-0000 Eaton Bussmann 315FM 100,000 A 600 Vac~ DT3xx-450xx-xxxxx or DT(1 or 3)xx-500xx-xxxxx 700A 0808-0359-0000 Eaton Bussmann 700FMM 100,000 A 600 Vac~ DT1xx-(600 or 700)xx-xxxxx 250A (4 per leg) 0808-0363-0250 Siba 20 559 20.250 100,000 A 600 Vac~ DT2xx-(600 or 700)xx-xxxxx 450A (2 per leg) 0808-0357-0000 Eaton Bussmann 450FMM 100,000 A 600 Vac~ Notes: Tests performed with worst case fuse rating of product and smallest SCR module size. s designated as only do not have Branch Circuit s and a Separate Branch Circuit is required in the system. The Series DFJ fuse is rated as both a and Branch Circuit. UL File E4273 JDDZ, CSA File 53787 Class 1422-02. Tests performed with FWP series fuses representative of FWC series fuses. s of similar family style (FWP, FWC, FWH, 170M, DFJ) as those tested but of smaller amperage rating are considered compliant. Document References NEC 2008 NFPA 70 TM : National Electrical Code International Electrical Code Series http://www.nfpa.org UL508 Industrial Control Equipment UL508A Industrial Control Panels Underwriters Laboratories Inc. (UL) 333 Pfingsten Road Northbrook, IL 60062-2096 Electric Manufacturing Co. 6 2009 Electric Manufacturing Company