Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Similar documents
LZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC

Electric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve

Electric Cylinders. It can be operated like an air cylinder. Directional control driver works like a solenoid valve

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

Mini Free Mount Cylinder

Rotary Actuator/Vane Type

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

Mini Free Mount Cylinder

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

Guide Table. MGF Series

Vane Type Rotary Actuator 50, 63, 80, 100

Compact Cylinder/Plate type

Vane Type Rotary Actuator

Guide Table. ø40, ø63, ø100

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT.

Compact Guide Cylinder Series MGQ

Round Type Hydraulic Cylinder

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80

Mini Free Mount Cylinder

2-Color Display High-Precision Digital Pressure Switch

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

Rotary Actuator/Vane Type

Series MSU. Rotary Table Vane Style. High Precision. Size: 1, 3, 7, 20 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D mm or less.

Free Mount Cylinder for Vacuum

Mini Rotary Actuator/Rack & Pinion Style

Rotary Table/Vane Style

Guide Table. Series MGF

Mini Rotary Actuator/Rack & Pinion Style

High Rigidity/ High Precision Guide Type ø50, ø63. The use of two linear guides allows a maximum load of 320kg. (ø63) Rodless cylinder MY1BH SMC

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

Dual-Rod Cylinder Compact Type

Rotary Table/Vane Style

Dual-Rod Cylinder Compact Type

Heavy Duty Stopper Cylinder

Compact Guide Cylinder

Model Pressure range ON/OFF output Linear output

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

Compact Type Dual-Rod Cylinder

Hygienic Design Cylinder

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V

Compact Cylinder: Standard Type Double Acting, Single Rod. How to Order 30 D F9BW. Body option <Standard stroke> Nil C M. Double acting.

1.7 kg. % lighter. 1.9 kg. Air Cylinder. Weight MB1. Reduced weight by changing the shape of the rod cover and head cover.

Series 10-ZSE40A(F)/10-ISE40A

Parallel Style Air Gripper: Wide Type

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Series CYP. ø15, ø32 Clean Rodless Cylinder. How to Order

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Round Type Hydraulic Cylinder

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.

Non-Contact Sensor for Workpiece Placement Verification

Dual Rod Cylinder: Double Rod Type. How to Order. Load voltage Auto switch model Perpendicular In-line 3-wire (NPN equivalent) Y7NWV Y7NW 5 V, 12 V

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released. 5-77

Series MXH/ ø6, ø10, ø16, ø20

Linear slide cylinder Double acting single rod type. Bore size: 4.5, 6, 8. Descriptions Bore size mm

Ionizer (Nozzle type) Series IZN10

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

Angular Style Air Gripper

2-Color Display High-Precision Digital Pressure Switch

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Rotary Actuator. New. New RoHS. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB2. Two shaft options available

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Compact Rotary Actuator

Model Pressure range ON/OFF output Linear output

MHR3/MDHR3 Series. Rotary Actuated Air Gripper/3-Finger Type. Size: 10, 15 MDHR 3 10 R M9N S. How to Order. Without auto switch

New cylinder body allows small auto switches to be mounted on 4 surfaces.

HL (AZH) LIMIT SWITCHES

Small Bore Hydraulic Cylinder

Small Bore Hydraulic Cylinder

Electric Actuators Series LX/LC6D CAT.EMC-LX/LC6D-01-UK

Toggle Type Air Gripper

Rotary Actuator/Vane Style

Series RSH/RS1H. To stop pallets gently. Heavy Duty Stopper Cylinder. Stopper cylinder with built-in shock absorber. ø20, ø32 ø50, ø63, ø80

Pin Shift Cylinder. High Precision. Position Reproducibility CKQ G-X2370. Deflection ±0.1 mm or less INFORMATION. For High Precision Positioning

SG-B1 SERIES / SG-A1 SERIES

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Lateral parallel hand Double acting. Operational stroke length: 20, 30, 40mm. 980m/s2

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Series CYP. Clean rodless cylinder ø15, ø32. How to Order

HL (AZH) Limit Switches

Transcription:

Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40, 50, 0, 0 System Chart P.926 Model Selection P.927 Electric Cylinder/LZB P.928 Electric Cylinder/LZC P.934 LZB/C Vertical Application Specifications P.938 Accessories P.939 Auto Switch Proper Mounting Position (Detection at Stroke End) and It's Mounting Height P.941 Mounting and Moving Auto Switches P.942 925

LZ Series System Chart Cable for control terminal -1-C2- -1 (Option) (See page 948.) Directional control driver for electric cylinder Series PLC (Terminal box type) (Supplied by customer) 24 VDC power supply (Supplied by customer) Cable for motor output terminal -1-C3- -1 (Option) (See page 948.) Terminal box AC power supply (Supplied by customer) Noise filter, Insulator, Relay, etc. (Supplied by customer) D-M9 (Option) Cable for power supply terminal -1-C1- -1 (Option) (See page 948.) Electric cylinder LZB/LZC Series 926

LZB/LZC Series Model Selection Note) These graphs are made using actual data. Therefore these graphs are to be used as a reference and are not a guarantee of product s performance in any case. The graphs may change depending on the operating condition or environment. Horizontal Motion of Pressing Force Model selection condition 1) Used as a force-pressing. 50 N or greater pressing force is required. Load thrust (N) Horizontal Transfer Model selection condition 2) Used as a transfer. 60 N transfer thrust and 40 mm/s transfer speed are required. Load thrust (N) 0 90 80 70 60 50 40 30 280 260 240 2 0 180 160 140 1 0 80 60 40 Model selection result 1) Lead 2 mm Model selection condition 1) Lead 6 mm Lead 2 mm Model selection result 1) From Graph 1, LZB/C 3 s lead 2 is applicable. (Pressing force: 80 N) Graph 1 3: [Speed -Thrust] Relationship Graph 0 0 40 60 80 0 1 140 160 180 0 2 240 260 280 300 3 340 360 380 400 Speed at the end (mm/s) Model selection result 2) From Graph 2, LZB/C 5 s lead 6 mm and lead mm are applicable. But, speed at the end with 60 N load will be 0 mm/s for lead 6 mm and 60 mm/s for lead mm. Select a suitable product in accordance with the customer s equipment. Model selection condition 2) Lead 6 mm Lead mm Graph 2 5: [Speed -Thrust] Relationship Graph Model selection result 2) Lead mm 0 0 40 60 80 0 1 140 160 180 0 2 240 260 280 300 Speed at the end (mm/s) Speed -Thrust Graph (Horizontal Operation) 3 Load thrust (N) Speed at the end (mm/s) 5 Load thrust (N) 0 90 80 70 60 50 40 30 0 0 40 60 80 0 1 140 160 180 0 2 240 260 280 300 3 340 360 380 400 280 260 240 2 0 180 160 140 1 0 80 60 40 0 0 40 60 80 0 1 140 160 180 0 2 240 260 280 300 Speed at the end (mm/s) 927

Electric Cylinder LZB Series How to Order LZB B 3 L 0 A 3 With auto switch LDZB B 3 L 0 A 3 M9B Built-in magnet Mounting type B Basic type L Axial foot type F Rod flange type U Rod trunnion type Cylinder size 3 Equivalent to ø16 cylinder Note) 5 Equivalent to ø25 cylinder Note) Note) Equivalent to 0.4 MPa, theoretical output (lead 2) For details, refer to page 927 Speed Thrust Graph. Thread lead (mm) L Lead 2 M Lead 6 H Lead Stroke (mm) Refer to Standard Stroke table. Motor type A DC motor Nil Without auto switch (Built-in magnet) Refer to the table below for auto switch model numbers. es are shipped together (not assembled). Rod end thread Nil L Female Male Motor size 3 Applicable cylinder size 3 5 Applicable cylinder size 5 Number of auto switches Nil 2 pcs. S 1 pc. n n Rod end male thread is shipped together. Standard Stroke Cylinder size Standard stroke (mm) 3, 5 25, 40, 50, 0, 0 Other intermediate strokes can be manufactured upon receipt of order. (Maximum manufacturable stroke: 0 mm) Conditions for using a trunnion bracket are as follows: Maximum stroke: 150 mm Thread lead L (lead 2 mm) only Applicable Auto Switches/For detailed auto switch specifications, refer to page 944. Lead wire length (m) Special Electrical Wiring Load voltage Type function entry (Output) DC AC model 0.5 1 3 5 (Nil) (M) (L) (Z) 3-wire (NPN) 5 V M9N Grommet Yes 3-wire (PNP) 24 V V M9P 2-wire V M9B Lead wire length symbols: 0.5 m... Nil (Example) M9B 1 m... M M9BM 3 m... L M9BL 5 m... Z M9BZ Solid state auto switches marked are produced upon receipt of order. Solid state auto switch Indicator light Pre-wired connector Applicable load IC circuit Relay PLC 928

Electric Cylinder LZB Series Specifications Model L ZB 3L L ZB 3M L ZB 3H L ZB 5L L ZB 5M L ZB 5H Size 3 (Equivalent to ø16 cylinder) Note 1) 5 (Equivalent to ø25 cylinder) Note 1) Thread diameter ø8 ø Lead screw Lead (mm) Note 2) Rated speed with no load (mm/s) Note 3) Rated thrust (N) 2 33 80 6 0 43 0 24 2 33 196 6 0 117 0 72 Stroke (mm) 25, 40, 50, 0, 0 Main body (kg) 0.67 + (0.07/50 stroke) 1.74 + (0.16/50 stroke) Operating ambient temperature ( C) Allowable tolerance of stroke Motor 5 to 40 (No condensation) +1 0 DC motor Applicable directional control driver model -5A3-5A5 Applicable auto switch model D-M9N, M9P, M9B Note 1) Equivalent to 0.4 MPa, theoretical output (lead 2) Note 2) In the table speeds are shown without a load, as rated speed, and thrusts are shown as rated thrust based on the pressure force. Note 3) Speed will vary as they are affected by a load. Refer to page 927 for model selection. Refer to page 939 for mounting bracket weight. 1. Do not apply any lateral load to the rod of the LZB series. When applying a lateral load, use a guide to avoid the load from being applied to the rod. Guide Specific Product Precautions w w 2. mounting There are 4 grooves on the outside surface of the cylinder tube, indicating the auto switch installation range. Mount the auto switches within the range shown below. LZB installation range Groove 1 1 4 x grooves installation range Mount the auto switch within the installation range (shadow portion). Otherwise, the auto switch may not activate. Refer to page 942 for information on mounting an auto switch. 929

LZB Series Dimensions Note) Grounding must be performed. For details, refer to the back of page 5. L(D)ZBB3 M x 1.5 Hexagon width across flats 13 (Part no.: SN-0B) Hexagon width across flats 26 Hexagon width across flats 27 (O.D. ø28) ø27 Width across flats 26 The electrical entry direction is different depending on the product. J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent Lead wire UL07 AWG22 (Red-) 19 M30 x 1.5 150 ± 15 (13) () 2 x M3 x 0.5 Depth 3 (For GND connection) Note) When extended Rod end nut (Part no.: NT-015A) M6 x 1.0 M x 1.5 (Part no.: SN-0B) Hexagon width across flats 5 21 Rod end male thread: L Axial foot type/l(d)zbl3 26 28.5 Hexagon width across flats 26 Rod flange type/l(d)zbf3 M x 1.5 Hexagon width across flats 13 M6 x 1.0 Thread length 8 4 x ø4.5 Hexagon width across flats 26 Hexagon width across flats 27 (O.D. ø28) 19 Width across flats 26 ø27 M30 x 1.5 50 41 ø14 ø38 ø28 ø14 ø38 M6 x 1.0.5 Thread length 8 15 6.5.5 43.5 8 13 8.5 + Stroke Stroke +1 0 216.5 + Stroke (87) When retracted Hexagon width across flats 26 Hexagon width across flats 13 M6 x 1.0 Thread length 8 M x 1.5 43.5 ø14 (Part no.: SN-0B) Hexagon width across flats 27 (O.D. ø28) ø27 Width across flats 26 Motor side mounting nut (Part no.: LZ-NT30) M30 x 1.5 19 Lead wire UL07 AWG22 (Red-) 2 x M3 x 0.5 Depth 3 (For GND connection) Note) Hexagon width across flats 38 ø38 J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent 38 150 ± 15 () 28.5 49.5 2 x ø6.8 ø4 40 6.5 8 9.8 28 3.2 71.7 + Stroke 3.2 28 (87) 2 x ø6.8 ø4 (13) 55 216.5 + Stroke 40 (Part no.: SN-0B) 55 34 6.5 4 8 13 8.5 + Stroke.5 15 43.5 (87) 216.5 + Stroke 930

1 Electric Cylinder LZB Series Dimensions Rod trunnion type/l(d)zbu3 Hexagon width across flats 13 M6 x 1.0 Thread length 8 ø32 32 52 ø8e9-0.025-0.061 ø14 6.5 16 Hexagon width across flats 26 Hexagon width across flats 27 (O.D. ø28) ø27 Width across flats 26 8 13 8.5 + Stroke 216.5 + Stroke 19.5 43.5 15 M30 x 1.5 In the event of mounting a trunnion bracket, fix it to the position illustrated below before using. installation range 4 x grooves (Part no.: SN-0B) 1 90 installation range Conditions for using a trunnion bracket are as follows: Maximum stroke: 150 mm Thread lead L (lead 2 mm) only Caution for using a trunnion bracket Groove (87) ø38 931

LZB Series Dimensions Note) Grounding must be performed. For details, refer to the back of page 5. L(D)ZBB5 The electrical entry direction is different depending on a product. J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent Lead wire Hexagon width across flats 41 UL07 AWG22 (Part no.: SN-040B) Width across flats 36 (Red-) 16 M32 x 2 Width across M45 x 1.5 Hexagon width across flats 21 flats 38 ø43 150 ± 15 M x 1.25 Thread length 17 Rod flange type/l(d)zbf5 M x 1.25 Thread length M32 x 2 Hexagon width across flats 21 Hexagon width across flats 41 Width across flats 36 Width across flats 38 ø43 M45 x 1.5 16 36 52 ø22 ø55 ø22 ø55 (42) Stroke +1 0 When extended 14.5 11 17.5 14 35 131.5 + Stroke 285.5 + Stroke When retracted (2) 2 x M4 x 0.7 Depth 3 (For GND connection) Note) Rod end nut (Part no.: NT-03) M32 x 2 (Part no.: SN-040B) M x 1.25 Hexagon width across flats 17 6 19.5 22 32 Hexagon width across flats 41 Rod end male thread: L Axial foot type/l(d)zbl5 (Part no.: SN-040B) M x 1.25 M32 x 2 Thread length Hexagon width 35 across flats 21 Hexagon width across flats 60 Hexagon width across flats 41 M45 x 1.5 Width across flats 36 Width across flats 38 14.5 17.5 ø43 Lead wire UL07 AWG22 Motor side mounting nut (Red-) 16 (Part no.: LZ-NT45) J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent 61 38 38 61 ø22 ø55 (42) 71 150 ± 15 2 x ø7 ø4 55 75 16.8 33 23 3.2 33 88.7 + Stroke 23 (2) (Part no.: SN-040B) 3.2 285.5 + Stroke 2 x ø7 ø4 55 75 2 x M4 x 0.7 Depth 3 (For GND connection) Note) 66 82 4 x ø7 5 14.5 11 17.5 14 35 131.5 + Stroke (2) 932 285.5 + Stroke

1 Electric Cylinder LZB Series Dimensions Rod trunnion type/l(d)zbu5 øe9-0.025-0.061 M x 1.25 Thread length 53 77 installation range M32 x 2 Hexagon width across flats 21 ø22 26.5 11 14.5 1 90 Hexagon width across flats 41 Width across flats 36 ø43 Width across flats 38 131.5 + Stroke installation range 17.5 14 35 11 285.5 + Stroke M45 x 1.5 In the event of mounting a trunnion bracket, fix it to the position illustrated below before using. 4 x grooves (Part no.: CM-T040B) Conditions for using a trunnion bracket are as follows: Maximum stroke: 150 mm Thread lead L (lead 2 mm) only Groove (2) Caution for using a trunnion bracket 16 ø55 933

Electric Cylinder LZC Series How to Order Built-in magnet B L LZC B With auto switch LDZC B 3 L 0 A 3 Mounting type Basic type Axial foot type 3 Cylinder size 3 Equivalent to ø16 cylinder Note) 5 Equivalent to ø25 cylinder Note) Note) Equivalent to 0.4 MPa, theoretical output (lead 2) L Thread lead (mm) L Lead 2 M Lead 6 H Lead 0 A 3 H Cover specification Nil H F None Partially covered Fully covered M9B Number of auto switches Nil 2 pcs. S 1 pc. n n Nil Without auto switch (Built-in magnet) Refer to the table below for auto switch model numbers. es are shipped together (not assembled). Cover specification H Partially covered F Fully covered Select a cover when using an auto switch. Stroke (mm) Refer to Standard Stroke table. Motor type A DC motor Rod end thread Nil L Female Male Rod end male thread is shipped together. Motor size 3 Applicable cylinder size 3 5 Applicable cylinder size 5 Standard Stroke Cylinder size Standard stroke (mm) 3, 5 25, 40, 50, 0, 0 Other intermediate strokes can be manufactured upon receipt of order. (Maximum manufacturable stroke: 0 mm) Applicable Auto Switches/For detailed auto switch specifications, refer to page 944. Special Electrical Wiring Load voltage Type function entry (Output) DC AC 3-wire (NPN) 5 V Grommet Yes 3-wire (PNP) 24 V V 2-wire V Lead wire length symbols: 0.5 m... Nil (Example) M9B 1 m... M M9BM 3 m... L M9BL 5 m... Z M9BZ Solid state auto switches marked are produced upon receipt of order. Solid state auto switch 934 Indicator light model M9N M9P M9B Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Pre-wired connector Applicable load IC circuit Relay PLC

Electric Cylinder LZC Series Specifications Model L ZC 3L L ZC 3M L ZC 3H L ZC 5L L ZC 5M L ZC 5H Size Lead screw Thread diameter 3 (Equivalent to ø16 cylinder) Note 1) ø8 5 (Equivalent to ø25 cylinder) Note 1) ø Lead (mm) Note 2) Rated speed with no load (mm/s) Note 3) Rated thrust (N) 2 33 80 6 0 43 0 24 2 33 196 6 0 117 0 72 Stroke (mm) 25, 40, 50, 0, 0 Main body (kg) Lateral load for rod end (at maximum stroke) (kg) 0.72 + (0.03/50 stroke) 0.1 1.72 + (0.16/50 stroke) 0.24 Operating ambient temperature ( C) Allowable tolerance of stroke Motor 5 to 40 (No condensation) +1 0 DC motor Applicable directional control driver model -5A3-5A5 Applicable auto switch model D-M9N, M9P, M9B Note 1) Equivalent to 0.4 MPa, theoretical output (lead 2) Note 2) In the table speeds are shown without a load, as rated speed, and thrusts are shown as rated thrust based on the pressure force. Note 3) Speed will vary as they are affected by a load. Refer to page 927 for model selection. Refer to page 939 for mounting bracket weight. Allowable Lateral Load for Rod End Allowable lateral load for rod end (N) 14 8 6 4 2 LZC5 LZC3 0 0 50 0 150 0 250 300 Stroke (mm) 935

LZC Series Dimensions Note) Grounding must be performed. For details, refer to the back of page 5. L(D)ZCB3 8 40 37 4 x M3 x 0.5 Effective thread depth 3 (6.5) Stroke +1 0 When extended When retracted 3 + Stroke (Total length) M6 x 1.0 Effective thread depth 8 4 x M4 x 0.7 Effective thread depth 6 8 1.5 7 + Stroke 6 82 24 16.5 ø17 ø14 ø38 A 16.5 38 Hexagon width across flats 13 15 2 x M4 x 0.7 Effective thread depth 4 M6 x 1.0 5 150 ± 15 Hexagon width across flats () Cover specification 19 mounting groove (13) 24 J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent Rod end male thread: L Lead wire UL07 AWG22 (Red-) 2 x M3 x 0.5 Depth 3 (For GND connection) Note) View A 38 Fully covered: F Partially covered: H Axial foot type: L 8 2 2 x ø4.5 32 2 x ø4.5 45 53 7.5 11.5 2 45 53 2 86.5 + Stroke (Mounting pitch) 15 936 Foot (Rod cover side) Foot (Housing side)

Electric Cylinder LZC Series Dimensions Note) Grounding must be performed. For details, refer to the back of page 5. L(D)ZCB5 57.5 52.5 4 x M4 x 0.7 Effective thread depth 4 16 15.5 () Stroke +1 0 When extended When retracted J.S.T. Mfg Co., Ltd.-made, ring terminal insulated with nylon N1.25-M4 or equivalent Lead wire UL07 AWG22 (Red-) M x 1.25 Effective thread depth 4 x M5 x 0.8 Effective thread depth 8 13 3 19 268 + Stroke (Total length) 139 + Stroke.5 16.5 19 ø56 5.5 16 150 ± 15 38 25.5 ø27.5 ø22 55 (42) 19 25.5 58 M x 1.25 Cover specification 26.5 58 mounting groove Axial foot type: L 13 3.2 30 49 2 x ø6.5 30 6 Hexagon width across flats 21 2 x M4 x 0.7 Depth 3 (For GND connection) Note) 2 x M6 x 1.0 Effective thread depth 6 Hexagon width across flats 17 19.5 22 35 Rod end male thread: L 38 Fully covered: F Partially covered: H 64.7 2 x ø6.5 64 3.2 15 76 16.7 76 111.5 + Stroke (Mounting pitch) Foot (Rod cover side) Foot (Housing side) 937

LZB/LZC Series LZB/C Vertical Application Specifications Some of the LZ series can be used in vertical applications. However, please check before using vertically. Never apply a force exceeding the prescribed force. When a force exceeding the transfer thrust is applied, the cylinder and directional control driver () may be damaged. Model which can be used vertically L(D)ZB 3L- A3 - L(D)ZC 3L- A3 - L(D)ZB 5L- A5 - L(D)ZC 5L- A5 - Specifications Model Speed (mm/s) Transfer thrust (Vertically) (N) Holding force (N) Standard stroke (mm) Operating ambient temperature ( C) Motor Applicable directional control driver model Applicable auto switch model L(D)ZB 3L L(D)ZC 3L L(D)ZB 5L L(D)ZC 5L P.927 Refer to the graph on speed thrust. 40 25, 40, 50, 0, 0 5 to 40 (No condensation) DC motor 0-5A3-5A5 D-M9N, D-M9P, D-M9B Holding force Holding force means the force which cannot be dropped even if a load should be applied vertically when a cylinder is stopped. Therefore, for example, holding is not possible when turning off the power supply once a cylinder has been activated. Additionally, a load may be dropped due to external impacts or vibrations. 938

Electric Cylinder LZB/LZC Series Accessories LZB Accessory Description With auto switch Foot type Flange type Trunnion type LZC Accessory Foot type Switch mounting band, switch mounting bracket (one included per one switch) Rod side foot bracket, motor side foot bracket, motor side mounting nut Flange bracket, rod side mounting nut Trunnion bracket (designed for trunnion) Description Rod side foot bracket, motor side foot bracket Foot bracket mounting bolts (6) Accessory Bracket Mounting nut ød 30 C d Rod end nut ød 30 C d Name Motor side mounting nut Motor side mounting nut H Part no. SN-0B LZ-NT30 SN-040B LZ-NT45 Applicable series LZB3 LZB3 LZB5 LZB5 B 26 38 41 60 C B D 30 25.5 42 38 47.3 40.5 64 60 d M x 1.5 M30 x 1.5 M32 x 2.0 M45 x 1.5 (mm) H 8 Part no. NT-015A NT-03 H Applicable series 3 5 B 17 C 11.5 19.6 D 9.8 16.5 B d M6 x 1.0 M x 1.25 (mm) H 5 6 Mounting Bracket/Part No. Rod side foot Motor side foot Flange Series Rod side trunnion LZB3 LZB-LR3 (64 g) LZB-LM3 (64 g) LZB-F3 (40 g) CM-T0B (40 g) LZB5 LZB-LR5 (1 g) LZB-LM5 (6 g) LZB-F5 (1 g) CM-T040B (0 g) ( ): Weight for bracket Note) Bracket mounting nuts are not included. Please purchase mounting nuts matched to each bracket separately. Rod side foot Motor side foot Series LZC3 LZC-LR3 (21 g) LZC-LM3 ( g) ( ): Weight for bracket Note) Mounting bolts are not included. Please prepare separately. LZC5 LZC-LR5 (71 g) LZC-LM5 (27 g) 939

Auto Switches Mounting Auto Switch Hysteresis Hysteresis is the distance between the position at which slider movement operates an auto switch to the position at which reverse movement turns the switch off. This hysteresis is included in part of the operating range (one side). Hysteresis Switch operating position (ON) (Solid state auto switch: 1 mm or less) Note) Switch operating position (OFF) Note) Hysteresis may fluctuate due to the operating environment. Please contact SMC if hysteresis causes an operational problem. 940

Electric Cylinder LZB/LZC Series Auto Switch Proper Mounting Position (Detection at Stroke End) and It's Mounting Height Solid state auto switch D-M9 LDZB C.5 A 22 B 17 Auto Switch Mounting Position/Height Model LDZB 3 LDZB 5 LDZC A 33 B 19 33 C 24 32 A1 Operating Range of Auto Switch Model LDZB 3 LDZB 5 B1 A 3 5 The operating range is a guide including hysteresis, but is not guaranteed. There may be substantial variation depending on the surrounding environment (assuming approximately ±30% dispersion). Minimum Stroke for Auto Switch Mounting Model 1 pc. 2 pcs. 2 pcs. (Different sides) (Same sides) LDZB 3 LDZB 5 15 15 45 45 A2 B2 Auto Switch Mounting Position for Stroke End Detection Model LDZC 3 LDZC 5 A1 4.5 7 A2 17.5 57 B1 41.5 B2 28 44 Operating Range of Auto Switch Model LDZC 3 LDZC 5 A 2 2 The operating range is a guide including hysteresis, but is not guaranteed. There may be substantial variation depending on the surrounding environment (assuming approximately ±30% dispersion). Minimum Stroke for Auto Switch Mounting Model 1 pc. 2 pcs. LDZC 3 LDZC 5 5 5 941

LZB Series Mounting and Moving Auto Switches (Series LDZB Only) Caution 1. Tighten the screw under the specified torque when mounting the auto switch. 2. Set the auto switch mounting band perpendicularly to cylinder tube. Correctly attached Incorrectly attached Mounting the Auto Switch 1. Attach a switch bracket to the switch holder. (Fit the switch bracket to the switch holder.) 2. Mount an auto switch mounting band to the cylinder tube. 3. Set the switch holder (1.) between the reinforcing plates of the band mounted to the cylinder. 4. Insert an auto switch mounting screw in the hole of the reinforcing plate through the auto switch holder, and thread it into the other plate. Tighten the screw temporarily. 5. Remove the set screw attached to the auto switch. 6. Attach a switch spacer to the auto switch. 7. Insert the auto switch with the switch spacer from the back of the switch holder. (Insert the auto switch with an angle of approximately to 15. See figure 1.) 8. To secure the auto switch, tighten the switch mounting screw with the specified torque (0.8 N m to 1.0 N m). Adjusting the Auto Switch Position 1. Unloosen the auto switch mounting screw 3 turns to adjust the auto switch set position. 2. Tighten the auto switch mounting screw as described above (8.) after adjustment. Removing the Auto Switch 1. Remove the auto switch mounting screw from the switch holder. 2. Move the auto switch back towards the position where it stops at the lead wire side. 3. Hold up the lead wire side of the auto switch at the angle of around 45. 4. Maintain the angle, and pull back the auto switch obliquely at the same angle. Switch holder (Resin) q Switch bracket (Stainless steel) Approx. to 15 Figure 1. insert angle e mounting screw (Low carbon steel wire rod) r i The parts indicated in attached to BJ3-1. Auto Switch Mounting Bracket/Part No. Applicable series Mounting bracket Mounting band Switch spacer (Stainless steel) t Set screw (unused) BJ3-1 LDZB 3 Switch holder BM2-025 Switch spacer LDZB 5 Switch bracket L1ZB45-0318 Order one auto switch mounting bracket and one auto switch mounting band per one auto switch. u y are Face the rubber lining surface upward. 60 to 80 Reinforcing plates BM2 942

Prior to Use Auto Switch Connection and Example Sink Input Specifications Source Input Specifications 3-wire, NPN 2-wire 2-wire AND connection Input COM Input 3-wire AND connection for NPN output (Using relays) Relay 3-wire AND connection for PNP output (Using relays) Relay (PLC internal circuit) 3-wire, PNP 2-wire (Performed with auto switches only) (Performed with auto switches only) 2-wire OR connection Input COM COM (PLC internal circuit) COM Input (PLC internal circuit) (PLC internal circuit) Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications. 1 2 1 2 1 2 Example of AND (Series) and OR (Parallel) Connection Load Load Load Load 1 2 1 Load 2 1 2 When using solid state auto switches, ensure the application is set up so the signals for the first 50 ms are invalid. When two auto switches are connected in series, a load may malfunction because the load voltage will decline when in the ON state. The indicator lights will light up when both of the auto switches are in the ON state. es with load voltage less than V cannot be used. Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Example: Power supply is 24 VDC Internal voltage drop in auto switch is 4 V. Load 3-wire OR connection for NPN output 1 2 Load 3-wire OR connection for PNP output 1 2 (Solid state) When two auto switches are connected in parallel, malfunction may occur because the load voltage will increase when in the OFF state. Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 ma x 2 pcs. x 3 kω = 6 V Example: Load impedance is 3 kω. Leakage current from auto switch is 1 ma. Load (Reed) Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches. 943

Auto Switches Solid State Auto Switch Applicable Actuators D-M9 (F9) LZ Series Auto Switch Specifications model Contact Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light Standard D-M9N D-M9P D-M9B N.O. (A contact) In-line 3-wire 2-wire NPN PNP 24 VDC IC circuit, Relay, PLC relay, PLC D-F9G NPN D-F9H N.C. (B contact) 3-wire PNP IC circuit, Relay, PLC 5,, 24 VDC (4.5 to 28 V) 5,, 24 VDC (4.5 to 28 V) ma or less ma or less 24 VDC 28 VDC or less ( to 28 VDC) 28 VDC or less 40 ma or less 2.5 to 40 ma 40 ma or less 1.5 V or less 80 ma or less 0.8 V or less at ma (0.8 V or less 4 V or less (2 V or less at 40 ma) at ma 0.8 V or less load current) 0 µa or less at 24 VDC 0.8 ma or less 0 µa or less at 24 VDC Red LED illuminates when turned ON. Red LED illuminates when turned OFF. CE marking Lead wires Oilproof heavy-duty vinyl cord: ø2.7 x 3.2 ellipse (D-M9 )/ø2.7 (D-F9 )/ø3.4 (D-Y7 ), 3 cores (,, ), 2 cores (, ). Insulation resistance Over 50 MΩ at 500 VDC Mega (between lead wire and case) Withstand voltage 00 VAC 1 minute (between lead wire and between case) Ambient temperature to 60 C Operating time 1 ms or less Impact resistance 00 m/s 2 For details, refer to Best Pneumatics No. 2-1. With pre-wired connector is also available. 944

LZB Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 13 for Electric Actuators/Cylinders and Auto Switches Precautions. Caution 1. Mount the auto switches at the center of the operating range. Check ON and OFF points before setting auto switches so that positions can be detected at the center of the operating range. If mounted at the end of the operating range, the signal detection will be unstable. 2. Be aware of the environment temperature and thermal cycle. Operate auto switches and auto switch cylinders within the operating temperature range. The reliability of the auto switches may be adversely affected, especially, when they are exposed to thermal shock, severe temperature and humidity cycle etc. 3. Be aware of the suitability of oil, chemicals etc. Resin and rubber materials are used for the auto switches and auto switch mounting brackets. Therefore, if there are chemicals such as oil or organic solvents in the environment, the resin and rubber materials may be adversely affected. 4. During maintenance, securely tighten the switch mounting screws periodically. Use auto switch mounting brackets with the proper tightening torque. In addition, securely tighten the auto switch mounting screws periodically. 5. Be careful not to pull or strain the lead wires. Be careful not to apply excess tensile force (over N) to the auto switches. Also, adjust the position of the auto switches by sufficiently loosening the auto switch mounting screws (3 turns or more). 6. Do not use the auto switches in environments with strong vibration and impact. Do not use the auto switches in environments where excess vibration and impact force outside of the specifications are applied. 7. Be sure to use a switch spacer and a switch bracket. Confirm that a switch spacer is mounted to the end of the auto switch before fastening the auto switch. If the switch bracket is not mounted, the auto switch may move after installation. 945