Storage Tank Risk Management Solutions Leak

Similar documents
SPCC Marina Inspection Update Oklahoma Marina Association Inspector Tom McKay

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

1) Activity Description: Management of Petroleum Storage Tanks and Containers

Pennsylvania DEP Aboveground Storage Tank Facility Visits NISTM PA CONFERENCE Washington, PA May 18, 2017

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Testing Requirements for UST s and AST s. By Mark Lindsey June 27 th, 2013

Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

SPCC Regulation Integrity and Leak Testing Methods

Overview of an Underground Storage Tank Inspection

(Please type or use black ink)

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

AST REGISTRATION PIPE INSPECTION PE REQUIREMENTS. David D. Bradeson, P.E. Chemung Contracting Corporation

Spill Prevention, Control, and Countermeasure. Training Module

John Benson David Hanny Barton & Loguidice, P.C.

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Mark S. Morgan, Regulatory Counsel

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

YOUR SPCC PROGRAM: A CHECK UP

NCDEQ Underground Storage Tank Section

ABOVEGROUND STORAGE TANK REGULATIONS -ADAM WILSON SLS LAND & ENERGY DEVELOPMENT

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

New UST Installation Inspection Checklist

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

NYSDEC PBS REGULATIONS Heating Oil Tanks

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

Safe Operating Procedure

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

Understanding the Inspection Process for Owners and Operators

Petroleum Storage Tank Release Detection and Inventory Control

Arizona Tank Closure, Assessment and Response

Management of Underground Storage Tanks

Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

Syracuse University Petroleum Bulk Storage Tank Program Manual

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

CONTENTS. Foreword...iii. 1. Introduction...1

Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage

New UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

04/08/2017. What Are The Environmental Regulatory Requirements/Programs Related To Aboveground Storage Tanks That I Have To Comply With?

RHODE ISLAND New England Storage Tanks Conference Westborough, MA. Joe Cunningham Jillian Thompson

Background. AEM Tier 2 Worksheet Petroleum and Oil Product Storage. Glossary. Agricultural Water Quality Principle:

Pennsylvania DEP: Maintaining UST Compliance and Regulation Updates. NISTM 8 th Annual Pennsylvania Storage Tank Conference May 18, 2017

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

Sunoco, Inc Market Street LL Philadelphia, PA June 29, 2006

ECM environmental compliance monitoring, inc. 1

NYSDEC CBS Compliance Requirements

Regulatory Changes: Chapter 245. AST s

401 KAR 42:020. UST systems: design, construction, installation, and registration.

Massachusetts Department of Environmental Protection Underground Storage Tank Program

Coordination with the Spill Prevention, Control, and Countermeasures Plan

Readopt with amendment Env-Wm , eff (doc. #8359), to read as follows:

CHAPTER 245. ADMINISTRATION OF THE STORAGE TANK AND SPILL PREVENT

Pipe & Re-Pipe A Perspective from Florida. R. Steven Miller Project Manager Downstream Data Corporation

Monthly Walkthrough Inspections

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

Title: Jet Engine Test Cell

INTEGRITY TESTING OF CONTAINMENT SUMPS AND SPILL BUCKETS PEI RP1200

Compliance Strategies and Benefits

Fuel Storage Dec 2016

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

New Regs Get Ready for Containment Testing if You Haven t Done So Already!

LEAKING UNDERGROUND STORAGE TANKS

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Steel USTs: History and Trends. Wayne Geyer, STI/SPFA August 1, 2013

INTEGRITY INSPECTION OF ABOVE GROUND STORAGE TANKS. Frank Maitland, PE QUENSE LLC 136 Edgemere Avenue West Hartford, CT

Ohio s Used Oil Regulations for Generators

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE

Field-Erected AST Secondary Containment Options. Mott-Smith Consulting Group, LLC

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

How to Stop Spill Buckets from Draining You Dry

Underground Storage Tank Guidance for Commercial Building Inspectors

Underground Storage Tank. City of Burbank UST Owners & Operators

State of New Jersey. Department of Environmental Protection Air Quality Permitting

Security Sensitive Information Redacted, Version

TITLE 165. CORPORATION COMMISSION CHAPTER 25. UNDERGROUND STORAGE TANKS RM PROPOSED RULES NOVEMBER 30, 2015

Department of the Environment. Moving Away From Stage II Vapor Recovery

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

Compliance Strategies and Benefits. Brian Derge Tanknology Inc. December 6, 2012

Vehicle and Equipment Fueling

Questions And Answers About The 2015 Underground Storage Tank Regulation As Of May 2017

Steel Tank Institute Updates 8 th Missouri Storage Tank Conference August 30, 2018 Blue Springs

How to Comply with Florida DEP AST Rules and Avoid Petroleum Discharges to the Environment

Arizona. UST Contamination How and Why. Presenter David Rabb 2015 ARIZONA STORAGE TANK CONFERENCE PHOENIX, AZ MAY 28, 2015

Environmental Regulations and Codes For Underground Tank Storage of Flammable & Combustible Liquids

APPENDIX D: SPCC REQUIREMENTS OVERVIEW

ANNUAL UST SYSTEM INSPECTION CHECKLIST

INSPECTION, EVALUATION, AND TESTING

EJIF Municipal Inspection Checklist

Transcription:

Storage Tank Risk Management Solutions Leak Prevention and Tank Integrity Inspections for ASTs Brian Pine ATC Group Services NISTM 8th Annual Pennsylvania Storage Tank Conference 1

2

ATC GROUP SERVICES IN OUR REGION What is ATC Eclipse? Centered in Retail and Bulk Petroleum and Chemical Marketplace Compliance Services ~Tank Inspections ~Sump Inspections Petroleum Field Services ~Installations ~Repairs PADEP Certifications: IAM IUM UMX UTT AMMX AMNX AMR 3

TOPICS What a good system looks like Regulations, State and Federal Prevention is the Key The most probable cause of a spill What happens when a spill occurs, anatomy of spill response Spill event case studies Photographs 4

GOOD SYSTEM Anti-Siphon Product Identifier Labels 5

GOOD SYSTEM Normal Vent 3 Product Fill 3 Primary and Secondary E-Vents 6

GOOD SYSTEM Block Valve, Anti-Siphon Valve (PEI RP 200) Spill Cabinet (Emergency Containment) 7

REGULATIONS FOR LEAK DETECTION AND SPILL PREVENTION 8

STATE/FEDERAL AST LEAK DETECTION/ SPILL PREVENTION REGULATIONS - PENNSYLVANIA State of Pennsylvania 25 Pa Code 245 Storage Tank and Spill Prevention Program Subchapters F (large) and G (small) Aboveground Storage Tanks 245.541 Overfill Prevention Requirements Gauge or monitoring device, AND High level alarm with cut off device or manned operator shut down written procedure 245.542 Containment Requirements 245.543 Leak Detection Requirements (large tanks) Existing ASTs without secondary containment under the bottom of the tank that are in contact with soil without CP or internal lining shall be leak tested at the next IS and each IS inspection thereafter until upgraded 245.613 Monitoring Standards (small tanks) Monthly leak detection monitoring required 9

PENNSYLVANIA INSPECTION STATISTICS 2016 AST Inspections in PA* 919 Aboveground Storage Tank Integrity Inspections in PA (performed by 3 rd party DEP certified inspectors) 136 Monthly Maintenance Check Violations (performed by owners/operators) 698 Performance/Design Standards Violations (paint surface coating, label, vents, etc.) 183 Containment Violations *Statistics provided by PADEP, some tanks had more than 1 violation. 10

PADEP MONTHLY INSPECTION FORM 11

PADEP THIRD PARTY INSPECTION FORM 12

PADEP VIOLATIONS: DESIGN STANDARD VIOLATIONS 13

PADEP CONTAINMENT VIOLATIONS 14

STATE/FEDERAL AST LEAK DETECTION REGULATIONS WEST VIRGINIA State of West Virginia West Virginia Code Aboveground Storage Tank Act 22-30 Each regulated Level 1 and 2 aboveground storage tank and its associated secondary containment structure must be evaluated and certified by a qualified person, as described below: professional engineer, American Petroleum Institute (API), or Steel Tank Institute (STI) certified individual API 653 Leak Detection: STI Leak Detection: CONTINUOUS RELEASE DETECTION METHOD (CRDM) a means of detecting a release of liquid through inherent design. Several acceptable and commonly used CRDM systems are as follows: Release prevention barrier (RPB) (described in definition of release prevention barrier). Secondary containment AST, including double-wall AST or double-bottom AST. Elevated AST, with or without release prevention barrier. RELEASE PREVENTION BARRIER (RPB) a liquid containment barrier that is installed under the AST. Its purpose is to divert leaks toward the perimeter of the AST where they can be easily detected, as well as to prevent liquid from contaminating the environment. RPBs are composed of materials compatible with the liquid stored in the AST and meet appropriate engineering standards. Examples are steel (as in steel double bottom tanks), concrete, elastomeric liners or other suitable materials, provided the above criteria are met. 15

WEST VIRGINIA, FIT FOR SERVICE? 16

STATE/FEDERAL AST LEAK DETECTION REGULATIONS EPA SPCC Federal EPA SPCC (Spill Prevention, Control and Countermeasures) 40 CFR 112 applicability simplified: 1. Is your facility non transportation related? 2. Is your facility engaged in drilling, producing, gathering, storing, processing, refining, transferring, distributing, using or consuming oil? 3. Could your facility reasonably be expected to discharge oil in quantities that may be harmful into navigable waters or adjoining shorelines? 4. Is the total aggregate capacity of aboveground oil storage containers more than 1,320 gallons of oil? Your facility is subject to the SPCC rule. 112.7(e),112.8(c)(6), 112.12(c)(6)(i) Test or inspect each aboveground container for integrity on a regular schedule.. Conduct inspections and tests. Industry Standards API 653, STI SP001 > Leak Detection and Containment! 17

SPCC = SPILL PREVENTION CONTROL & COUNTERMEASURE Prevention is the primary goal of your spill plan How to prevent spills from occurring? Proper Design Frequent Inspections Regular Maintenance Training Awareness + Planning = Prevention 18

PREVENTION IS THE KEY 19

MOST PROBABLE CAUSE OF SPILLS Cause Tank Corrosion Overfill Prevention Method Inspection Planning Design Training Piping/Fitting Failure Inspection/Maintenance Most spills are preventable! 20

INTERNAL CORROSION AND PITTING A multi-billion $$ industry was built around USTs with holes in them We have an advantage with ASTs we can inspect them from the outside 21

CORROSION ANALYSES - UT TESTER API 653 Corrosion Rate Calculations The minimum acceptable shell thickness (Tmin) is determined using the following Equation: t min = 2.6D(H-1)G / SE Per API 653, T(min) shall not be less than 0.1 inch for any tank course Pitted Corrosion Install Date Original Thickness Min Field Thickness Corrosion Loss Mn Thick API 653 Inspection Interval Rate of Corrosion RCA (t a -t min ) Remaining Tank Life Course (t o ) inches (t n ) inches (inches) (tmin) inches (years) (in/year) (inches) (years) shell Apr-03 0.25 0.244 0.006 0.1 13.5 0.00044 0.144 324.00 end cap Apr-03 0.375 0.32 0.055 0.1 13.5 0.00407 0.220 54.00 22

WHEN A SPILL OCCURS: ANATOMY OF A SPILL RESPONSE Phase I Notification and Initial Response Phase II Containment and Source Removal Phase III Plan Review and Amendment EPA inspection and enforcement Phase IV Long Term Remediation 23

PHASE I NOTIFICATION AND INITIAL RESPONSE STOP the release if you can do so safely. ELIMINATE sources of ignition. NOTIFY local, state and Federal agencies Local FD State notification: one drop to multiple gallons All states and EPA: sheen on surface water Failure to notify is a MAJOR violation and will become an enforcement penalty multiplier and/or criminal violation Get HELP! Don t skimp at this point to save $$ 24

PHASE I (CONT.) What Spilled? Material released (MSDS) Quantity released Where did the spill go? (Hint: this is part of your SPCC Plan) Containment? Catch basin? Groundwater? Surface water? 25

PHASE II CONTAINMENT AND SOURCE REMOVAL Contain the release What happens if it rains/snows? Can more oil leak from the tank system? Have pathways to surface waters been identified and protected? Can you prevent further impact to groundwater? Source removal Timing is everything. The faster you remove the source, the lower the overall cost 26

SOURCE REMOVAL YOUR BEST INVESTMENT ( AFTER PREVENTION) Recover as much oil before it migrates vertically/horizontally Timeframe: minutes to hours After liquid recovery, excavate as much soil as you can Timeframe: hours to days Whatever is left will need to be mechanically extracted, treated in situ, and/or monitored Timeframe: months to years 27

PHASE III PLAN REVIEW AND AMENDMENT Evaluate your SPCC plan Is the Plan up to date and fully implemented? Are upgrades required to tanks or containment? After a spill occurs is not a good time to start your compliance program EPA and/or your state regulators will likely conduct an inspection If you don t have a plan, you will now!!! 28

PHASE IV LONG TERM CLEANUP Floating product recovery Soil and groundwater remediation Monitoring and reporting Risk assessment and closure planning What you do in Phase I and II determines the duration and costs of Phase IV 29

CASE STUDIES WHEN PREVENTION FAILS 30

CASE STUDY #1 PIPING RELEASE AT BULK PLANT 615 gallons fuel oil released at a rural VT bulk facility 31

THE GOOD Tanks on concrete pads Written SPCC Plan in place ( but not implemented) 32

THE BAD Excessive flex of a flex coupling caused a stress fracture in fitting Note: Potable water valve used for petroleum service 33

THE UGLY 615 gallons discharged to containment Containment floor insufficiently impervious 34

VAC TRUCK AND PUMPING SYSTEM 35

DESPITE QUICK RESPONSE Sheen detected in nearby stream 36

FORENSIC ANALYSIS Improper design of piping, valve and containment structure SPCC plan not fully implemented Customer responded to spill once detected, but not before sheen was detected on stream This was the 2 nd spill reported to EPA in a 4 year period HINT: It all goes downhill from here 37

EPA ENFORCEMENT ACTION Resultant RCRA Facility Investigation: Included all 5 company facilities Multiple violations resulted in a $157,500 penalty PLUS, structural and administrative upgrades required $350,000 spent within 9 months Million gallon tank with inadequate containment and no FRP dismantled Containment upgrades at 2 facilities SPCC Plans revised at all facilities Contaminated soil uncovered during upgrades 38

CASE STUDY #2 OVERFILL Bulk Storage Tank connected to Pipeline Operator thought that he would have time to go to the bar across the street for a quick beer Bartender points to diesel shooting out tank vent Operator runs back to terminal to close valve Diesel? 39

CASE STUDY #2 OVERFILL CONTINUED Operator on site, not drinking beer? 40

CASE STUDY #2 OVERFILL CONTINUED 23,000 gallons diesel released to containment (steel sides, soil bottom) 14,000 gallons recovered by vac truck 9,000 gallons lost to subsurface Containment steel sides, soil bottom Groundwater at 23 feet 3.9 feet of LNAPL in 14 wells within 2 weeks 41

SPILL PREVENTION > CLEANUP IS ONLY PART OF THE COST Loss of Inventory Loss of Equipment Use / Revenue Generation Administrative Hassle Financial Penalties Loss of Reputation Natural Resource Damages Loss of Business Criminal Penalties Loss of Life 42

FIELD INSPECTION FINDINGS ~ DO YOU HAVE CONTAINMENT? 43

FIELD INSPECTION FINDINGS ~ CONTAINMENT???? 44

FIELD INSPECTION FINDINGS ~ SW OR DW TANK? Two E-Vents 45

FIELD INSPECTION FINDINGS ~ SW! Interstice is full of water, no containment of the primary tank 46

FIELD INSPECTION FINDINGS ~ CHECK THE INTERSTICE! 47

FIELD INSPECTION FINDINGS ~ CHECK THE INTERSTICE! 48

FIELD INSPECTION FINDINGS ~ CHECK THE INTERSTICE! 49

FIELD INSPECTION FINDINGS ~ BLOCK VALVE POSITION CORRECT? No PEI RP 200 The first accessible valve.be constructed of steel..capable of withstanding a reasonable degree of stress created by a fire condition. 50

FIELD INSPECTION FINDINGS ~ DOES THIS TANK HAVE PROPER EMERGENCY VENTING? No Wire tie 51

Questions??? 52