Leak Prevention Building Tighter Systems with Enhanced Leak Detection. Service Provided by CGRS, Inc.

Similar documents
Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by CGRS, Inc.

(Addendum to the March 1994 Evaluation) March 11, 1999

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

KWA. Evaluation of the Vaporless Manufacturing LD 3000 and LD 3000S Mechanical Line Leak Detector on Large Rigid and Flexible Pipelines.

Use of Vacuum for Prevention of Leaks. Wayne Geyer Steel Tank Institute

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Ken Wilcox Associates, Inc.

Leak Detection for Petroleum UST and Piping

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

Arizona. UST Contamination How and Why. Presenter David Rabb 2015 ARIZONA STORAGE TANK CONFERENCE PHOENIX, AZ MAY 28, 2015

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

Underground Storage Tank. City of Burbank UST Owners & Operators

WSB clean: Installation Manual

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

The VST Enviro-Loc Vapor Recovery System

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

VEEDER-ROOT COMPANY. Product Knowledge Session. Understanding Line Leak Detection Methods / Test Type / Certifying

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

CHAPTER 12 SERVICING. Section Title Page

INTEGRITY TESTING OF CONTAINMENT SUMPS AND SPILL BUCKETS PEI RP1200

Department of the Environment. Moving Away From Stage II Vapor Recovery

Introduction to Condition-Based Maintenance Best Practices

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

NCDEQ Underground Storage Tank Section

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

New UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.

Release Detection Challenges for High Throughput Facilities

700 Series Thermal Switch High Reliability

Overview of an Underground Storage Tank Inspection

Solar Impulse, First Round-The-World Solar Flight. Ralph Paul Head of Flight Test and Dynamics Solar Impulse June 22, 2017

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

UNDERGROUND STORAGE TANK (UST) INSTALLATION & MAINTENANCE

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

Mark S. Morgan, Regulatory Counsel

Lessons in Systems Engineering. The SSME Weight Growth History. Richard Ryan Technical Specialist, MSFC Chief Engineers Office

Steel USTs: History and Trends. Wayne Geyer, STI/SPFA August 1, 2013

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

Fab Efficiency. A new Power Quality and Energy Monitoring Technology for Fabs and Tools

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

White Paper.

AGILENT VACUUM VALVEs

General Issues of Line Leak Detection

INSTALLATION INSTRUCTIONS

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

Underground Storage Tank Guidance for Commercial Building Inspectors

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY STATISTICAL INVENTORY RECONCILIATION (SIR) GUIDANCE DOCUMENT

PROACTIVE PRODUCT SERVICING

ANNUAL UST SYSTEM INSPECTION CHECKLIST

RULE LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015)

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Farm & Residential Tanks Angle skids

NISTM 2015 New England UST and Shop-Fab Storage Tank Conference

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97

Chapter 1 Aircraft Electrical System

LOW LEVEL SUMP TESTING ORIGINS

Evaluation of the Highland Tank Periodic Interstitial Vacuum Test Procedure for Double-Wall Underground Tanks (Titan, STi-P3,ACT-100U and HighGuard )

New Regs Get Ready for Containment Testing if You Haven t Done So Already!

AGILENT VACUUM VALVES

EPA UST Regulations Update May 22, 2018

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

RELIABLE AND EFFICIENT SYSTEMS

40 CFR 63, Subpart CCCCCC

Contact Name: Company Name: Technician Name: Company Address: Company Phone: Company Fax: Address. Technician SSN:

Research Challenges for Automated Vehicles

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

Valve Solutions Series 150/160 and V-100 Valves

NYSDEC PBS REGULATIONS Heating Oil Tanks

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

New Tank Installations. Peter Rollo

P.O. Box 435 Saratoga Springs, NY 12866

Midas is committed to earning your trust by providing the expertise, value and responsiveness you expect.

Welcome to the SEI presentation on the basics of electricity

Compliance Strategies and Benefits

Relay Contact Ratings. Operating Temperatures. Life Expectancy. Humidity Tolerance Enclosure Mounting Weight

Renewable Energy Sprint

DIESEL FUEL STORAGE CORROSION - DECAY

MEETING TIGHT QUALITY SPECIFICATIONS IN PRODUCT BLENDING WITH MICRO MOTION BY JULIE VALENTINE, MICRO MOTION, INC.

Underground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION

Christian Quijano Rounds and Associates. John Albert Department of Agriculture. Heather Peters Department of Natural Resources

SPCC Regulation Integrity and Leak Testing Methods

ProSimTechs PROCESS SIMULATION TECHNICS

Understanding Fuel: Costs, Purchasing, Pricing Strategy, & Internationally

IST INTELLIGENT SUBMERSIBLE TURBINE

Dual Fuel Filter Controller AND Fuel Polishing System GPH Fuel Flows Cleaner Fuel - Better Performance - Better Mileage

Using Virtualization to Accelerate the Development of ADAS & Automated Driving Functions

Analysis and Testing of Debris Monitoring Sensors for Aircraft Lubrication Systems

Vehicle Performance. Pierre Duysinx. Research Center in Sustainable Automotive Technologies of University of Liege Academic Year

TRICENTRIC VALVES TRICENTRIC METAL SEATED BUTTERFLY VALVE TRIPLE OFFSET

Leak testing in the automotive industry. Applications for Component Manufacturing and Final Testing

NRC Non-Destructive Examination Research

To study about various types of braking system.

END-OF-LINE SYSTEM. DISCOM Noise Analysis for Gear Test

New UST Installation Inspection Checklist

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Transcription:

Leak Prevention Building Tighter Systems with Enhanced Leak Detection Service Provided by CGRS, Inc.

Everything Leaks! It s up to the user to determine what leak rate is acceptable. Service Provided by CGRS, Inc.

Power Steering Units 2e-4 cc/sec

Engine Blocks 1e-3 cc/sec

Pacemakers 1 E-9 cc/sec (1 cc in 31 years).

What leak rate should be acceptable for a new UST system? Service Provided by CGRS, Inc.

Current QC Testing Methods Pressure/Vacuum Decay Soap Bubble / Visual Hydro Service Provided by CGRS, Inc.

Commission Testing Precision Tank and Line Testing Monitoring System Enhanced Leak Detection Service Provided by CGRS, Inc.

Current Standards Tank Monitoring - 0.2 gph (1,752 gallons in 1 year). Precision Tank Testing - 0.1 gph as liquid (876 gallons in 1 year). Precision Line Testing 0.02 gph as liquid (175 gallons per year). ELD standards - 0.005 gph as vapor (2 E- 3 cc/sec) or (44 gallons of vapor per year). Service Provided by CGRS, Inc.

Enhanced Leak Detection (ELD) A leak testing method with a sensitivity capable of detecting a 0.005 gallon per hour leak (as vapor) with a 95% probability of detection and 5% probability of a false alarm. Leaks of this order of magnitude will not pass liquid. Service Provided by CGRS, Inc.

California ELD Requirements Adopted in July of 2003 Newly installed USTs must pass an ELD test in order to receive an operating permit. Service Provided by CGRS, Inc.

Why? Service Provided by CGRS, Inc.

Continued Problems Double wall system More complex in-field construction practices Vapor and liquid releases continue to occur Service Provided by CGRS, Inc.

New Construction ELD New UST systems are required to pass an ELD test after construction is complete. Primary containment systems only. One time test. Only one technology met this standard. Service Provided by CGRS, Inc.

Ouch!!! Initially failure rates approached 90% In some cases, new piping systems had to be removed and replaced Angry tank installers, owners and equipment manufactures. Could new systems meet this standard? DISASTER!! Service Provided by CGRS, Inc.

Solution! Perform helium pre-test prior to backfilling. Final test failure rates immediately dropped to less than 2%. Problem solved. Service Provided by CGRS, Inc.

Idea! Service Provided by CGRS, Inc.

Concept Develop a helium based ELD method for quality control testing newly constructed fueling systems.

Helium Leak Testing in Industry Originally used on Manhattan project during WWII for detecting small leaks in the gas diffusion process in the early 40 s. Commercialized in the early 50 s spurred on by the space program. Rapid leak testing with helium is used extensively in industry today.

Automotive Industry Fuel Tanks Cylinder heads Valves

Heat exchange and steam condensation lines Energy Industry

Semiconductor Industry Critical gas distribution lines

Aviation Industry Aircraft Wing Tanks and Oxygen Piping

The point is Quality control leak testing with helium is not a new concept. Using a refined, scientific based process for in-field quality control testing of fuel systems would be a new application. 0.005 gph as vapor sensitivity could be done in the field with a high degree of confidence.

R & D Service Provided by CGRS, Inc.

Leak Simulation Service Provided by CGRS, Inc.

Permeation Curve AMERON TEST 1 1.00E+00 1.00E-01 1.00E-02 1.00E-03 Leak Rate ATM-CC/S 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.00E-09 1.00E-10 1.00E-11 0 200 400 600 800 1000 1200 1400 Time in Minutes Leak Rate ATM-CC/S Power (Leak Rate ATM-CC/S) Service Provided by CGRS, Inc.

VaporTite V005 Enhanced Leak Detection (ELD) Method

Certifications Ken Wilcox and Associates EPA Non-Volumetric (tracer) Protocol. National Work Group on Leak Detection Evaluation Listing (NWGLDE) California State Water Resource Control Board (SWRCB) listing Service Provided by CGRS, Inc.

How it Works

Process 1. Pre Testing 2. Final Testing

Piping Primary

Tank Primary

Components in Containment

Test Setups

Connection at the turbine Service Provided by CGRS, Inc.

Piping Systems

Test Manifold Detail

Air Management System

No Leak 15 min

0.005 gph Leak 15 min

0.005 gph as vapor Service Provided by CGRS, Inc.

Typical Leak 14 min

Example Service Provided by CGRS, Inc.

Example Service Provided by CGRS, Inc.

Example Service Provided by CGRS, Inc.

Typical Leak 46 sec

Test Certification

Leak Locate Service Provided by CGRS, Inc.

Effect? Materials handling Installers strictly follow installation instructions Piping tools kept sharp and in good condition Eliminated unnecessary fittings Modification of secondary access fittings Installers learned to build tighter systems

Today We find 1-6 leaks on every site during pretesting and rarely does a system ever fail a final. Installers like knowing that their work has been checked by a 3 rd party before backfilling! Owners sleep better knowing that their installation has been QC tested to a very tight standard.

Leak Prevention Insuring tighter installations today will prevent releases in the future.

Eric Hick ehick@cgrs.com Thank you for your time! Service Provided by CGRS, Inc.