High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Similar documents
Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Determination of Sudan Dyes I IV in Curry Paste

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Technical Overview. Introduction

Application Note. Authors. Abstract. Energy & Chemicals

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Application Note. Abstract. Authors. Environmental Analysis

Test Report. No. SHAHG Date: 12 Dec Page 1 of 7.

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Laboratory SGS Bangladesh Limited, Laboratory Services, IIUC Tower, Plot No. 9, Agrabad Commercial Area, SK Mujib Road, Chittagong, Bangladesh

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

2. Main changes versus the German Consumer Goods Ordinance. No azo pigments are restricted under the EU Directive 2002/61/EC.

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Annex 3 List of dyes that generate specific aromatic amines (Informative) October 1, 2015

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Test Report No. GZTXO TX Date: Jun 30, 2008 Page 1 of 6

Agilent G5632 Valve Kit Instructions

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Phase Distribution of Ethanol, and Water in Ethyl Esters at K and K

S 1125 HPLC Pump System

TEST REPORT. Applicant : Sample Receiving Date : Oct 30, Testing Period : Nov 03, 2014 to Nov 05, Sample Description : Bag materials

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

GC/MS 20!"#$%"&'(!"#$%&'()*+, -./01!"#$%

Applicant: MATSUI SHIKISO CHEMICAL COMPANY LIMITED Date: Jun 22, KAMIKAZAN SAKURADANI-CHO YAMASHINA-KU

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Sample Description: Six (6) pairs of white nylon seamless knitted lining with acrylonitrile butadiene coating Standard : BS EN 420: 2003+A1: 2009

Agilent Valve Kit G4231A/B and G4232A/B/C

HyperShear TM HPLC Mixers

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

HyperShear TM HPLC Mixers

HyperShear TM HPLC and UHPLC Mixers

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

HyperShear TM HPLC and UHPLC Mixers

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

VERITY Purification Systems Build the perfect system to fit your research

HPLC System S 600 Series

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

TÜRKAK TÜRK AKREDİTASYON KURUMU TURKISH ACCREDITION AGENCY tarafından akredite edilmiş

Agilent 1290 Infinity Autosampler

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

HIGH PRESSURE SWITCHING VALVES

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Using the PSD for Backflushing on the Agilent 8890 GC System

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

HPLC SYSTEM S 500 SERIES

ACQUITY UPLC I-Class System with 2D Technology

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Agilent Online-SPE Direct Inject Kit G4744A

5 µm Preparative HPLC Columns

Application. Gas Chromatography June 1995

The Ministry of Environment and Forests has prohibited the handling of 112 dyes which are capable of releasing any of the harmful amines.

Liquid Chromatography

System Manual. Agilent 1260 Infinity Capillary LC System

NEW HPLC - SYSTEM LINE

Neueste LC Entwicklungen

SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Application Note. Author. Introduction. Energy and Fuels

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

TEST REPORT NO.SL64257 Date: April 14, 2015 Page 1 of 11

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

The Only No Compromise

Agilent 1260 Infinity Bio-inert Manual Injector

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Technical Procedure for Gas Chromatography (GC-FID)

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Agilent 1100 Series Capillary LC System. System Manual

Hydrocarbons. Land Based Gas Turbines Emissions Regulations and Measurement Methods

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Supplementary Material

Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC

Analysis of Petroleum Fractions by ASTM D2887

Agilent 1200 Series Manual Injector

Setting up SilFlow for BackFlush in your GC

Discipline Chemical Testing Issue Date Certificate Number T-2217 Valid Until Last Amended on

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique

Transcription:

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell Application Note Consumer Products Authors Gerd Vanhoenacker, Frank David, Pat Sandra Research Institute for Chromatography Kennedypark 26 8500 Kortrijk, Belgium Angelika Gratzfeld Huesgen Agilent Technologies Inc. Waldbronn, Germany Abstract In this Application Note, a set of toxic aromatic aes which may be released from certain banned azo colorants are analyzed with the Agilent 1290 Infinity LC System. A 1290 Infinity Diode Array Detector equipped with the Agilent Max-Light high sensitivity flow cell with a 60 mm optical path length is used to obtain highest sensitivity. The results are compared to results obtained with a standard flow cell (10 mm optical path length) and the performance of the high sensitivity method is investigated.

Introduction Azo dyes are colorants widely used in consumer products such as leather, textiles, and cosmetics. These products contain an azo group that can undergo reductive cleavage, leading to the formation of aromatic aes of which have known mutagenic and/ or carcinogenic properties. The use of certain azo dyes is prohibited in Europe, US, and many other countries. In the European Union a directive of 2002 describes the restrictions on the marketing and use of certain azo dyes 1 and official analytical methods have been published 2,3. The directive defines a limit value of 30 ppm (mg/kg sample) for a set of 22 potentially carcinogenic aes. If the detected amount is above this value, it is assumed that a certain azo colorant was used. The deteration of azo dyes involves a chemical reduction of the dye into the aes followed by HPLC-DAD or LC/MS analysis. Although LC/MS is a suitable technique to detere these aes at low levels 4, the use of DAD for this analysis is still widespread. This is mainly due to the lower cost of purchase and operation compared to MS instrumentation. The absence of the mass selectivity of an MS system necessitates the complete chromatographic separation of all compounds under investigation. This is not straightforward within an acceptable analysis time and a recent application note describes the use of the Agilent Method Development System and the Agilent Method Scouting Wizard software to develop and optimize the separation 5. The results describe the application of the previously developed method with the Agilent 1290 Infinity Diode Array Detector (DAD) equipped with a high sensitivity flow cell to perform trace analysis of the 22 restricted aes. Detection limits are typically around 0.2-1 ng/ml for standard solutions. This is significantly lower than the requested quantification limit to meet the European regulations. Performance parameters such as repeatability of injection, detection limits, and linearity are evaluated. Experimental Standard solutions A standard stock solution of 20 aes in acetonitrile (Azodyes-Mix 1, Dr. Ehrenstorfer, Augsburg, Germany) was mixed with a stock solution of azo compounds 04 and 20 (Sigma-Aldrich, Bornem, Belgium, see Table 1) to make up a 22 component standard mixture. This mixture was diluted in 0.1% formic acid in methanol/water 10/90 to the appropriate concentration. Peak Code Name CAS no. FW AZO 01 4-Methoxy-1,3-phenylenediae 615-05-4 138 AZO 02 2,4-Diaotoluene 95-80-7 122 AZO 03 4-Aophenylether 101-80-4 200 AZO 04 o-anisidine 90-04-0 123 AZO 05 4,4 -Benzidine 92-87-5 184 AZO 06 o-toluidine 95-53-4 107 AZO 07 Bis-(4-aophenyl)-methane 83712-44-1 198 AZO 08 4-Chloroaniline 106-47-8 127 AZO 09 2-Methoxy-5-methylaniline 120-71-8 137 AZO 10 2-Methyl-5-nitroaniline 99-55-8 152 AZO 11 3,3 -Dimethoxybenzidine 119-90-4 244 AZO 12 3,3 -Dimethylbenzidine 119-93-7 212 AZO 13 4-Aophenylthioether 139-65-1 216 AZO 14 2-Naphthylae 91-59-8 143 AZO 15 4-Chloro-2-methylaniline 95-69-2 141 AZO 16 2,4,5-Trimethylaniline 137-17-7 135 AZO 17 4,4 -Diao-3,3 -dimethyldiphenyl methane 838-88-0 226 AZO 18 4-Aobiphenyl 92-67-1 169 AZO 19 3,3 -Dichlorobenzidine 91-94-1 252 AZO 20 4-Aoazobenzene 60-09-3 197 AZO 21 4,4 -Methylene-bis(2-chloroaniline) 101-14-4 266 AZO 22 4-Ao-2,3-dimethylazobenzene 97-56-3 225 Table 1 Investigated azo dye derived aes listed in the European Parliament and Council Directive No. 2002/61/EC. 2

Results and discussion In order to illustrate the influence of the two DAD flow cells a 200 ng/ml standard solution was analyzed with both configurations. Theoretically, the Agilent Max-Light Cartridge High Sensitivity Cell should increase the sensitivity by a factor of 5 6. Figure 1 clearly shows the gain in sensitivity with the longer optical path length. Equipment An Agilent 1290 Infinity LC system with the following configuration was used: G4220A Agilent 1290 Infinity Binary Pump with integrated vacuum degasser G4226A Agilent 1290 Infinity Autosampler G1330B Agilent 1290 Infinity Thermostat G1316C Agilent 1290 Infinity Thermostatted Column Compartment G4212A Agilent 1290 Infinity Diode Array Detector G4212-60007 Agilent Max-Light Cartridge High Sensitivity Cell (60 mm optical path length) G4212-60008 Agilent Max-Light Cartridge Standard Cell (10 mm optical path length) Chromatographic Conditions Method parameters: Column: Agilent ZORBAX StableBond C18 RRHT, 100 mm L 4.6 mm id, 1.8 µm d p (p/n 828975-902) Mobile phase: A = 20 mm NaH 2 PO 4, ph 4.60 B = methanol/acetonitrile 50/50 v/v Flow rate: 1.6 ml/ Gradient: 1 12 5-80% B 12 12.1 80-98% B 12.1-14 98% B 14 15.5 5% B (post-time) Temperature: 36 C Injection: 20 µl, needle wash (4 s, flushport, mobile phase B) Detection DAD: Peak width Wavelength A=Time programmed >0.012 (20 Hz) B = Signal 235/20 nm, Reference off C = Signal 245/10 nm, Reference off D = Signal 285/30 nm, Reference off Spectra acquisition On, 190 400 nm 0-5.6 Signal 210/5 nm, Reference off 5.6-8.6 Signal 262/10 nm, Reference off 8.6-14 Signal 386/15 nm, Reference off 80 60 40 20 0 80 60 40 20 0 Agilent Max-Light Cartridge Standard Cell (10 mm optical path length, G4212-60008) 0 2 4 6 8 10 12 Agilent Max-Light Cartridge Standard Cell (60 mm optical path length, G4212-60007) azo01 azo02 azo03 azo04 azo05 azo06 azo07 azo08 azo09 azo10 azo11 azo12 azo13 azo14 azo15 azo16 azo17 0 2 4 6 8 10 12 azo18 azo19 azo20 azo21 azo22 Figure 1 Comparison of the standard (10 mm) and high sensitivity (60 mm) flow cell for a 200 ng/ml standard mixture of the 22 azo derived aes. Detection wavelength: 245 nm. 3

The sensitivity of the method was further optimized by using various detection wavelengths for the specific aes. Channel A was timeprogrammed and three other channels were used to cover all 22 aes. The result for a low level standard (10 ng/ml) is shown in Figure 2. The large system peak is present at 245 nm close to the retention time of azo 21. This demonstrates that the quality of the solvents and material used with the high sensitivity cell is of utmost importance because interferences are enlarged in the same order as the analyte peaks. The influence of the flow cell at this concentration level is demonstrated for Channel A in Figure 3. The increased signal-to-noise ratio with the high sensitivity flow cell is obvious. 62 61 60 0 2 4 _ 2 20 10 0 1 0 _ 1 _ 2 azo01 235 nm azo02 235 nm 2 4 6 8 10 235 nm azo04 azo06 azo09 azo10 azo13 azo14 262 nm 386 nm 2 4 6 8 10 245 nm azo03 azo07 azo08 2 4 6 8 10 285 nm azo05 2 4 6 8 10 azo11 azo12 azo16 azo15 azo17 azo18 azo20 azo19 azo21 azo22 Figure 2 Analysis of a 10 ng/ml standard mixture with the high sensitivity flow cell. 11.9 11.8 11.7 11.6 11.5 Agilent Max-Light Cartridge Standard Cell (10 mm optical path length) 6 7 8 9 10 11 12 Agilent Max-Light Cartridge High Sensitivity Cell (60 mm optical path length) azo13 azo20 azo22 62 61.5 61 60.5 60 6 7 8 9 10 11 12 Figure 3 Comparison of the channel A signal on the standard (10 mm) and high sensitivity (60 mm) flow cell for a 10 ng/ml standard mixture. 4

The calculated signal-to-noise ratios for both detection cells are summarized in Table 2. S/N 10 mm S/N 60 mm Detection WL Azo 01 Not detected 4 235 Azo 02 11 38 235 Azo 03 15 55 245 Azo 04 9 26 235 Azo 05 22 50 285 Azo 06 10 32 235 Azo 07 21 74 245 Azo 08 22 74 245 Azo 09 14 44 235 Azo 10 16 51 235 Azo 11 17 31 285 Azo 12 27 55 285 Azo 13 19 109 262 Azo 14 64 195 235 Azo 15 17 58 245 Azo 16 10 30 235 Azo 17 21 71 245 Azo 18 26 58 285 Azo 19 26 58 285 Azo 20 17 99 386 Azo 21 17 59 245 Table 2 Comparison of signal-to-noise ratios obtained with the standard (10 mm) and high sensitivity (60 mm) flow cell for a 10 ng/ml standard mixture. 5

The repeatability of injection of the developed method was investigated at two concentration levels (100 and 500 ng/ml) by six consecutive injections. The linearity was calculated by single injections of various standard solutions. Table 3 shows these data together with the detection limits obtained with both flow cells. DAD WL Repeatability of injection, n = 6 (RSD%) LOD (ng/ml) Linearity tr Area 100 ng/ml Area 500 ng/ml 10 mm 60 mm Range (ng/ml) R 2 Azo 01 235 0.04 1.81 0.41 20 5 5-500 0.9887 Azo 02 235 0.03 0.31 0.05 5 1 2-500 0.9999 Azo 03 245 0.03 0.04 0.02 2 0.5 2-500 1.0000 Azo 04 235 0.03 0.44 0.06 2 0.5 2-500 0.9999 Azo 05 285 0.03 0.07 0.02 1 0.2 2-500 1.0000 Azo 06 235 0.03 0.05 0.06 1 0.5 2-500 0.9999 Azo 07 245 0.03 0.41 0.03 1 1 2-500 0.9999 Azo 08 245 0.03 1.86 0.06 1 1 2-500 0.9999 Azo 09 235 0.03 0.66 0.07 5 5 (1) 5-500 0.9995 Azo 10 235 0.03 0.37 0.03 1 0.2 2-500 0.9999 Azo 11 285 0.03 0.39 0.05 1 0.2 2-500 0.9989 Azo 12 285 0.03 0.37 0.03 1 0.2 2-500 1.0000 Azo 13 262 0.04 0.08 0.03 1 0.2 2-500 0.9999 Azo 14 235 0.03 0.18 0.02 5 0.2 2-500 1.0000 Azo 15 245 0.03 0.12 0.02 1 0.5 2-500 0.9999 Azo 16 235 0.03 0.29 0.06 1 0.5 2-500 0.9998 Azo 17 245 0.03 0.18 0.06 1 0.5 2-500 1.0000 Azo 18 285 0.03 0.14 0.14 1 0.2 2-500 0.9999 Azo 19 285 0.03 0.24 0.04 1 0.2 2-500 1.0000 Azo 20 386 0.03 0.18 0.06 1 0.2 2-500 1.0000 Azo 21 245 0.03 0.34 0.12 2 2 (1) 2-500 0.9999 Azo 22 386 0.02 0.12 0.11 1 0.2 2-500 1.0000 (1) Interfering peak Table 3 Performance of the developed method (60 mm flow cell unless specified otherwise). 6

Conclusion The use of the Agilent Max-Light High Sensitivity Cell in the Agilent 1290 Infinity DAD significantly increases the sensitivity for the azo colorant derived aes and enables the detection of levels as low as 0.2 ng/ml (4 pg oncolumn). The repeatability of injection and linearity of the method were acceptable and the improved sensitivity compared to the Agilent Max-Light Cartridge Standard Cell is demonstrated. References 1. European Parliament and Council Directive No. 2002/61/EC (19 July 2002). 2. European Standard No. EN 14362-1:2003 (October 2003). 3. European Standard No. EN 14362-2:2003 (October 2003). 4. S. S. Lateef, Agilent Technologies, Application Note 5990-5731EN (May 2010). 5. G. Vanhoenacker, F. David, P. Sandra, Application note method development system for Azo dyes, submitted 7

www.agilent.com/chem/lc Agilent Technologies, Inc., 2011 Published in USA, June 1, 2011 Publication Number 5990-8066EN