SciVerse ScienceDirect

Similar documents
Design of 33kV Transformer Bushing Insulator from NR and HDPE

Influence of Electric Field Distribution along the Line Post and Pin Post Insulator due to Lightning Strike

Energy Management and Control System for Smart Renewable Energy Remote Power Generation

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

3 TM Cold Applied Barrier Boot System

Honeywell Salisbury Outage Protection. Bushing Covers, Conductor Covers, Instant Insulation

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

PIPE INSULATORS, END SEALS AND INNER-LINKS GLOAZURE CO., LTD

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

Novel Automatic Demoulding and Feeding Device for Oil Seal Transfering Molding Press and Simulation Analysis

Datasheets - General Purpose Elastomers

Driver roll speed influence in Ring Rolling process

Experimental Study on Overflow Pipe Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Available online at ScienceDirect. Procedia CIRP 33 (2015 )

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Muti-objective topology optimization of an electric vehicle s traction battery enclosure

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

A Smart Mobile PV-Wind Hybrid System Prototype for isolated electrification. Abstract

Improved PV Module Performance Under Partial Shading Conditions

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

Branch Splice QS-2001B

Zhejiang Ejai Kitchen & Bath Technology Co., ltd

THE ECONOMICS OF RECYCLING RUBBER

Smart Grid Technology Principle and Application Smart Grid Measurement and Control

Sponge rubber products are manufactured in many different processes either by vulcanization in moulds or by extrusion.

Forced vibration frequency response for a permanent magnetic planetary gear

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLUORINATED ETHYLENE PROPYLENE, NON-CROSSLINKED

Experimental Study on Inlet Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

Distribution of Electric Field Analysis in 36 kv Roof Top Bushing by using FEM Techniques

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Reva Electric Vehicle Conversion to a Hydrogen Fuel Cell Powered Vehicle

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

Available online at ScienceDirect. Energy Procedia 36 (2013 )

Installation Devices 4

Design and Analysis of Arc Springs used in Dual Mass Flywheel

Available online at ScienceDirect. Procedia Engineering 137 (2016 ) GITSS2015

Tips & Technology For Bosch business partners

Design and fabrication of a twist fixture to measure torsional stiffness of a pick up chassis

EPDM sponge profile formulations: New approach with metallocene elastomers. years

SEALING SYSTEMS. ISO & DIN Gaskets

Development of a low voltage Dielectric Electro-Active Polymer actuator

Research on Optimization for the Piston Pin and the Piston Pin Boss

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

Static Structural and Thermal Analysis of Aluminum Alloy Piston For Design Optimization Using FEA Kashyap Vyas 1 Milan Pandya 2

High Voltage Copper, Smooth Aluminum Shield/Sheath

Failure of a rotary tiller spur gear

Hydraulic Characteristic of Cooling Tower Francis Turbine with Different Spiral Casing and Stay Ring

The Study of Thermoelectric Power Generation in The Cooling of Fin and Vibration Heat Pipe

Finite Element Analysis on Thermal Effect of the Vehicle Engine

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Electromagnetic Field Analysis for Permanent Magnet Retarder by Finite Element Method

ScienceDirect. Simulation and Testing of a Typical On-Board Charger for ITB Electric Vehicle Prototype Application

Analysis of Electric Field and Magnetic Field from Overhead Subtransmission Lines Affecting Occupational Health and Safety in MEA s Power System

outage protection Q: Why should I use outage protection?

Electric Field Modelling of Non-Ceramic High Voltage Insulators

Journal of KONES Powertrain and Transport, Vol. 21, No ISSN: e-issn: ICID: DOI: /

Available online at ScienceDirect. Energy Procedia 56 (2014 )

Study on State of Charge Estimation of Batteries for Electric Vehicle

Available online at ScienceDirect. Procedia Engineering 68 (2013 ) 70 76

Analysis of Stress in the Nissan Z-24 Moulding Crankshaft

Plastic Ball Bearing Design Improvement Using Finite Element Method

AEROFLEX. Closed Cell Elastomeric Thermal Insulation (made from E.P.D.M. - Ethylene Propylene Diene Monomer)

CONNECTION OF NEW GENERATORS IN THE ELECTRICAL POWER SYSTEM OF KOSOVO. Rexhep Shaqiri 1, Bogdanov Dimitar 2.

Remote Area Hybrid Solar-Diesel Power Systems in Tropical Australia

Series PVI/PVIF. Standard and Full Port Eccentric Plug Valves Conforming to AWWA C517

LIST OF PUBLISHED STANDARDS

VIBRATION REDUCTION IN CONVENTIONAL VEHICLES BY INCREASING THE STIFFNESS ON THE CHASSIS FRAME

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Available online at ScienceDirect. Energy Procedia 56 (2014 )

Dynamic Simulation of the Impact Mechanism of Hydraulic Rock Drill Based on AMESim Yin Zhong-jun 1,a, Hu Yi-xin 1,b

Method of Aircraft Fuel Tank System Ignition Source Fail- Safe Feature Analysis

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

INFLUENCE OF CERAMIC COATING ON PISTON SURFACE IN I.C ENGINE

Sensing of Diesel Vehicle Exhaust Gases under Vibration Condition

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TERMINATION ENCLOSURE OPTIONS

Products of integrity from people of integrity. w w w. n e w m a n g a s k e t. c o m

Redesign and Analysis of Automobile Wheel Rim #1 Pandit Shailesh, #2 Gajjal Shekhar

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

GROUP D. Switch & Protective device.

Design and experiment of hydraulic impact loading system for mine cable bolt

Wolf Kunststoff ZEDEX ZX-530 A5D Polymer Alloy

Potential of Large Output Power, High Thermal Efficiency, Near-zero NOx Emission, Supercharged, Lean-burn, Hydrogen-fuelled, Direct Injection Engines

A starting method of ship electric propulsion permanent magnet synchronous motor

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

O-RINGS METRIC SIZES AVAILABLE

[Attar* et al., 5(6): June, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

A novel use of the hybrid energy storage system for primary frequency control in a microgrid

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

PETSEALS. Material TENSILE STRENGTH (KG/CM 2 ) ELONGATION(%) TEMPERATURE RANGE( ) MATERIAL %MAX HRSX NITRILE 70 (NBR 70) ~100 70H x

The Experimental Study of the Plateau Performance of the F6L913 Diesel Engine

A magnetic fluid seal for rotary blood pumps: Long-term performance in liquid

THE INFLUENCE OF THE MICROGROOVES ON THE HYDRODYNAMIC PRESSURE DISTRIBUTION AND LOAD CARRYING CAPACITY OF THE CONICAL SLIDE BEARING

2nd Annual International Conference on Advanced Material Engineering (AME 2016)

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Transcription:

Available online at www.sciencedirect.com SciVerse ScienceDirect Energy Pr0Cedia ELSEV1ER Energy Pracedia9 (2011) 95-103 9lh Eco-Energy and Materials Science and Engineering Symposium Design of 33 kv Transformer Bushing Insulator from NR and HDPE Nilipong Panklang3, Nathabhat Phankong and Krischonme Bhumkittipich Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Thanyaburi. Klong 6, Thanyaburi, Pathumihani 12110, Thailand Abstract This research presents a design of transformer bushing insulation at high-votiage wire connection side. The bushing insulator is made from composite materials between natural rubber (NR) and high-density polyethylene (HDPE). The HDPE has been utilized to increase a weather resistance property of natural rubber, such as ultraviolet resistance, temperature, heat resistance, and so on. The blend ratio of materials depends on NR 60% and HDPE 40%. To study properties of insulator material, it is tested by using ASTM D2240 ASTM D412, ASTM D257-99 and ASTM D149-05 standard. The test results shown that the composite material has a tensile strength equal to 4.28+5.4 MPa, volume resistivity more than 2.14X10"1 Si-cm and surface resistivity about 5.56M016 ii/square. This insulation material can be withstanding a maximum AC power frequency voltage about 19.7 kv/mm. In additional to design, the electric field distribution around the bushing insulator is analyzed by using a finite element method (FEM). The highest electric field strength occurs at wire connector and equal to 0.95 kv/mm. Finally, the developed bushing insulator has been installed on 33 kv distribution systems at Saraburi province. 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of CEO of Sustainable Energy System, Rajamangala University ol Technology Thanyaburi (RMUTT). Keywords: Transformer bustling; Natural rubber, High density polyethylene; Finite element method 1. Introduction introduction Stabilii Stability and reliability are the most important of electrical power distribution system. Power outage is affecting "feeling to customers especially a manufacturing industry. The most of high voltage distribution systems a Corresponding author Tel- +66-2-549-3420. Fax: +66-2-549-3-422 E-mail- p mtipong@)gmat!.com, natbabhat.ptslsn.rimit! ac.th 1876-6102 2011 Published by Elsevicr Lid. Selection and/or peer-review under responsibilily of CEO of Sustainable Energy System, Rajamangala University of Technology Thanyaburi (RMUTT). doi:lg.i016/j.egypro.20l 1.09.011

% Niiipong Pankian eld. /EnerK? Pmcedw9(2OII) 95-103 in Thailand is overhead wire system. These systems have so many connections between wire terminals without msulation and risk to undesirable short circuit. The wire terminal of Attribution transformer, the one of connections that risks to short circuit due to reptiles or poultries, such as bird, sneak, squirrel, and etc This paper shows a novel design and development of protected insulator for transformer busing A developed busing insulator in this research will be protected a wire terminal. The insulation matena combines the natural rubber (NR) and the high density polyethylene (HDPE). To^certa"\ material properties, the material will be tested by ASTM D2240, ASTM D412, ASTM D257-99 and ASTM D149-05 standard. Also, the finite element analysis has been used for simulation ot a distributed electric potential and electric fieid. [Nomenclature EPDM ethylene-propylene diene monomer rubber FEA finite element analysis FEM finite element method HDPE high-density polyethylene NR natural rubber 2. Insulation Material Usually the most wire connection of distribution transformers, which is shown in Fig. 1, has not protected with insulator. The short circuit phenomenon is probably occurred by animals and etc. The solving of the short circuit problem is initially utilized with PVC water tube as simple cover msulation The insulator is sufficient to protect the wire terminal in the systems, but it is not engineering standard and beautiful. The insulator can storage some dust particles, water moisture, and leaf on top of connection. The protective insulator from PVC tube is shown in Fig. 2. Fig. 1. A wire connection of distribution transformer al primary side

Mpong Pankfon ci at. / Energy Pmcedia 9 {2011)95-103 97 Fig. 2. Using PVC waler tube for protected a primary wire connection. v.- (a] Fig, 3. Current EPDM bushing insulator for (a) single-phase transformer and (b) three-phase transformer (b) (a) (b) Fig. 4. Damage of EPDM bushing insulator (a) black powder from surface degradation and (b) thermal damage from heat and ultraviolet. In the case of the simple PVC insulator, the specific bushing insulator has been developed for protection purpose. It has many shapes depending on design and production company. Ethylene- Propylene Diene Monomer Rubber (EPDM), which has a limit of weather resistance properties, is a major insulation material. A current EPDM bushing insulator for single and three phase distribution transformer is shown in Fig. 3.

NlUpOng Pankttm el a!. / Energy Procediu 9 (20111 95 - The EPDM bushing insulator has many problems, such as black powder from surface degradation. And also it cannot resist heai and ultraviolet from sunlight. The surface degradation and thermal damage of the EPDM is shown in Fig. 4. In additional, the current EPDM bushing insulator is inconvenient design for maintenance. When bushing insulator has been damaged, the operators/technicians will necessary to take time for reassembling a new insulator into the wire terminal extensively. The insulation compounding material, which is the natural rubber (NR) and the high density polyethylene (HDPE) is developed in this research. The HDPE is used for increasing weather resistance properties of NR. The compounding rubber consists of 60% NR and 40% HDPE ratio. The materials and chemical substances are utilized to blend a compounding rubber as shown in Tab- 1. The compounding rubber has been proceeded to be (he vulcanized rubber sheet. It has the dimension about 150x150x2 mm for mechanical and electrical testing. The insulation tesis are composed of hardness tensile strength, surface and volume resistivity, and dielectric strength. The testing process refers to ASTM D2240, ASTM D412, ASTM D257-99 and ASTM D149-05. The testing results will be compare properties with other materials, such as EPDM, NR, and EPDM rubber with a same ratio of blending Table 2 shows the properties of NR+HDPE material that has 60% NR, 40% EPDM rubber. As shown in Table 2, a 60% NR and 40% HDPE rubber has similarity properties with a 60% NR and 40% EPDM rubber. NR+HDPE rubber has the hardness 83.7±0.9 shore A, which is more than NR+EPDM rubber about 56%. But NR+EPDM rubber is capable to support more tensile force. NR+EPDM rubber and NR+HDPE rubber have the tensile strength about 8.82+1.58 MPa and 4.28±5.4 MPa respectively. For surface and volume resistivity, the testing results shown that NR+HDPE rubber has the surface resistivity 5.56»!0'sn/square, volume resistivity 2.14><1016 fi- cm. The volume resistivity of NR+HDPE rubber is more than NR+EPDM rubber about 92.5% while the surface resistivity of NR+HDPE rubber is less than NR+EPDM rubber about 70.7%. From the testing properties, NR+HDPE rubber has qualified electric insulator because there is the more electric resistance [1]. Table I. Materials and chemical subslances for compounding rubber. Material Natural Rubber STR 51- High-Density Polyethylene Zinc Oxide Stearic Acid C yctohexyl benzoth i a2oles u 1 fa n am ide Tet tame I h y 1 til i uramd is u 1 li de Sulphur Carbon Black phr M 40 3 1 2 0.6 0.12 1.08 1 Table 2 Properties of vulcanized rubber from testing. Material Properties EPDM NR+EPDM (60:40) NR+HDPE (60-40) Hardness, Shore A 30-90 46.7 ±3 83.7±0.9 Tensile Strength, MPa 10-20 8.82 ±1 58 4-28 ±5.4 Elongation at Break, % 200-500 548 ± 29 92 ±29 Surface Resistivity, fl /square N.A. 1.9*10" 5.56* 10" Volume Resistivity, Q - cm. 1-10" 1.6*10" 2.14*10' Dielectric Strength, kv/mnv 0.9 17.9 19.7

Niiipang Panktaii el ni. / Energy Pnxxdia 9 (201!) 95-103 2. Design and computer simulation The bushing insulator was designed and developed by using a computer aided design for creating a 3-D model- Firstly, the realistic dimension of the insulator was built with the 3-D model of porcelain bushing. After that, the insulator was designed to be compatible dimension with porcelain bushing. The 3-D models of the insulator are shown in Fig. 5. The bushing insulator is composed of two parts. The part 1 is the main body insulator that has the dimension about 113x113x131 mm. The insulator sheet thickness is equal to 4 mm. The part II is the strap plate insulator with dimensional about 32x32x18 mm. The strap plate insulator has four pins for holding the bushing insulator as shown in Fig. 5(b). The assembly of both insulator parts is shown in Fig. 5(c). In this article, the 2-D model of bushing insulator can be explained with a mathematical model that used to analyze the electric field strength and voltage distribution by mean of the finite element analysis (FEA) pi- The Emulation of 2-D model of the bushing insulator, which is shown in Fig. 6, is composed of porcelain bushing, spark gap, wire terminal, and NR+HDPE busing insulator. The spark gap and wire terminal are defined as a perfect conductor because the joint of both conductors is neglected. The rated voltage of them is equal to 33 kv. The NR+HDPE bushing insulator and porcelain bushing are the isotropic material with no space charge. The NR+HDPE bushing insulator has the relative permittivity that is equal to the calculated relative permittivity of NR and HDPE [3] while the porcelain bushing insulator has relative permittivity equal to the NR+HDPE. The external boundary of model is simulated as vacuum that its relative permittivity is equal to 1 and no external electric field. For computation, the tolerance of solution for electric potential and electric field is less than lxlo"6. Figures 7 and 8 show the simulation results of porcelain bushing and bushing insulator from FEA. - >«J (a) (b) (c) Fig. 5. 3-D model of designed bushing insulator (a) part I: main body, (b) part II: strap plate, and (c) assembly of those insulators.

100 Nitipontt PtvMan el a!. / Energy Proceitici 9(2011) 95-103 I. i -- NK IIDI'l e, = - >!, twusti rl! -'i li -d* ' Fig. 6. 2-D model for Unite element analysis. Fig. 7. Voltage distribution around porcelain bushing and bushing insulator Fig. S An electric field strength that distributed around insulator.

Nitipong Panklan el at. / Energy PmcediaV (2011) 95-103 101 Figure 7 shows the simulation results of the voltage distribution when applied voltage at wire terminal and spark-gap are equal to 33 kv. The highest electric field strength arises at tip of spark-gap to 0.95 kv/mm. But the NR+HDPE bushing insulator received low electric field strength about 80V/mm by location. From the maximum electric field strength, the dielectric strength of materials was compared between them, which are shown in Tab. 2. The NR+HDPE bushing material can withstand electric field strength under normal usage situation. Furthermore, the worst case simulation is using a tree branch model wiih contacted to surface of the NR+HDPE bushing insulator. The tree branch defined as circle shape, which has a radius 10 mm and voltage equal to zero. The simulation results neglected an electric conductivity, surface and volume resistivity and relative permittivity of the tree branch. The simulation results of voltage and electric field are shown in Figs. 9 and 10, respectively. A grounding tree branch contacted to surface of bushing insulator increasing electric field strength and changing voltage distribution is shown in Figs. 9 and 10. The electric field strength at contact point is increased to 5.4 kv/mm. The bushing insulator was designed to be a wall thickness of main body insulator about 4 mm. The dielectric strength of materials is shown in Tab. 2. The wall sheet of bushing insulator can withstand the AC power frequency voltage about 78.8 kv. In this case, the bushing insulator can withstand the maximum electric field strength at contact point. in.,, ague Fig 9. Voltage distribution around porcelain bushing and bushing insulator when bushing insulator contacted with grounding Iree branch. l"\g 10. Electric field strength when bushing insulator contacted with grounding tree branch.

102 NUipong Panklan e: al. / Energy Ptvcedia 9(2011) 95-103 4. Bushing insulation installation From design and computer simulation, the building of metal molds for thermal compression process uses 3-D computer model. The metal mold has two sets. The first set uses for main body insulator, which is composed of two metal parts. The second set is a strap plate mold with their metal parts. Both of molds are shown in Fig. 11. By thermal compression manufacturing, the finished bushing insulator from the NR+HDPE material is shown in Fig. 12(a) and the installation example with porcelain bushing is shown in Fig. 12(b). The developed busing insulator has been installed in the 33W distribution system of Provincial Electricity Authority (PEA) at Saraburi province. The installed area is nearly cement plant, which has a lot of dust particles. Figure 13 shows the installation of the bushing insulator on the distribution system. The novel bushing insulator was conveniently installed to the system that was compared with the old design. Because PEA operator cannot remove the wire connector. The installation of the bushing insulator is faster than the old one. Therefore, the electrical distribution system is shut down shortly. (a] Fig. i 1. Meial molds of bushing insulator for heat compression molding (a) main body mold and (b) strap plate mold. <b) (a) Fig. 12. Developed NR+HDPE busliing insulator (a) two part of insulator (b) installation example (b)

- Nilipnng Panklon a al. /Energy Prncedia 9 (2011) 95-103 103 (a) Fig 13 Installation of NR+HDPE bushing transformer with disiribution transformer (a) before and (b) after. (b) 5. CONCLUSION This paper presented the novel design and development of bushing insulator. The developed bushing insulator is used to protect a primary wire connection of distribution transformer a! maximum AC voltage 33kV. The insulation material is composited from natural rubber and high density polyethylene by blending ratio 60:40. The insulation material has been tested by using ASTM D2240, ASTM D412, ASTM D257-99 and ASTM D149-05 standard. From test results shown that the developed insulator material has suitable properties to use for bushing insulator. This insulation material can be withstanding a maximum AC power frequency voltage about 19.7 kv/mm. In addition, the developed bushing insulator has been installed on the 33 kv distribution system of PEA at Saraburi province. REFERENCE [1] Hileman. AR, 1999. Insulation Coordination for Power Systems. Boca Raton, Florida, USA: CRC Press. [2] Reece, A.B.J. and Preston. T.W., 2000. Finite Element Methods in Electrical Power Engineering, New York: Oxford. [3] Raju, Gonir G.. 2003, Dielectric in Electric Fields, New York: Marcel Dekker, Inc.