Performance Selection Data

Similar documents
Design and Application Details

Pilot Capacities/Specifications

Assembly Numbers. Approximate net ship weight (in pounds) shown in parentheses

Capacities and Operating Data

Assembly Numbers Style A, B & C LINOFLAME Burners

Design and Application Details

Eclipse RatioAir Burners

APX Nozzle-mix line burner

Design and Application Details

Design and Application Details

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Eclipse Vortometric Burners Series HI

Start-up Instructions

APX Nozzle-mix line burner

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

GEMINI GAS CONTROL PRODUCT INFORMATION

KINEMAX. Medium velocity gas or oil burners

Specifications of STICKTITE and PILOTPAK Nozzles

APX Nozzle-mix line burner

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Specifications of STICKTITE and PILOTPAK Nozzles

FLOW TEK VALVES & CONTROL S INC

Data /1/07 Eclipse RatioAir Burners Model RA0040

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750


RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Eclipse RatioAir Burners

Specifications of OPTIMA SLS Burners

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

VALUPAK. Packaged gas burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

PREMIX TUNNEL BURNERS

North American Combustion Burners

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

LVDT/HC PILOT BURNER. External raw gas pilot burner

North American Combustion Burners

TriOx Triple Air Staged Ultra Low NOx Burner

North American 4575 HiRAM

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Self-Operating Temperature Regulators

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

CGi Series 2 Section Assembly

North American 4485 Tempest SE

2.0 Burner Operating Parameters and Requirements

F300 Pressure Regulator

INFINITE ENERGY 2-199

1470 SERIES HOT AIR GAS BURNER

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

F200 Pilot Operated Pressure Regulator

Forged Fittings. High Technology Valve & Fitting Series

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS

PT-M90 Automatic Full-Sequence Modulation Gas Control System

F200 Pilot Operated Pressure Regulator

Burner Selection Criteria

MULTIFIRE. High temperature dual fuel burner

IHR Series With Standard Oven ITEM NO DESCRIPTION PART # 36" 1 Top Grate Cast Iron 12" X 28" - (Old Style) 1187 N/A *** 12" Top Grate 12 x 13 1/4

VALUPAK. Packaged gas burners

Technical Information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Direct Gas-Fired Make-up Air Heaters

DELUGE VALVE DATA SHEET

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

SUMG-100. Burner Package & Components

MASTER DIRECT OIL HEATERS. MODEL 35 CED 10 kw Model ILLUSTRATED PARTS BREAKDOWN. Motor and Pump Assembly

GV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES.

Introduction to Johnson Controls Dampers

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Specifications of MAXON VALUPAK burners for 50 Hz operation

High Pressure 2-way 2 1/2-6 Globe Valves

ZEPHAIRE G MECHANICAL & SOLID STATE CONTROLS GAS CONVECTION OVENS REPLACEMENT PARTS LIST

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

Ultra High Efficiency Models With Direct Spark Ignition

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Turbo Pressure Blowers

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

1466 SERIES COLD AIR GAS/OIL BURNER

36H Gas Control Product Information

VENTING & COMBUSTION AIR GUIDE

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

Wafer Silent Check Valves

Type 459. Type 459. Available designs. Cap H2. with bushing 19. Lock nut. Bonnet. Outlet flange 2.4 Outlet adaptor 2.1. spacer.

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

IR 2000 Series Medium Duty Range w/standard Oven ITEM NO DESCRIPTION PART # 24" 36" 48" 60" 72" Griddle Plate Assembly 24"

PARTS MANUAL FOR HEAVY DUTY GAS BROILERS

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

Transcription:

Series "NP" & "RG" AIRFLO Burners Page 5505 Performance Selection Data Operation in shaded area requires special considerations Optimum Design Area Operation in shaded area requires special considerations Optimum Design Area 9/03

Page 5506 Series "NP" & "RG" AIRFLO Burners Performance Selection Data (cont'd.) Optimum Design Area Airstream velocity across and through your burner's mixing plates must be kept uniform and within desired limits by use of a silhouette profile plate through which the burner fires. A 6" (minimum) profile plate should be installed surrounding the interior duct walls at the leading edge of your burners mixing plates. Optimum design ranges for the various burner types are shown in the above graphs. Velocities (SFPM) are measured with a velometer directly in the duct at the plane of the profile plate and leading edge of burner mixing plates. To determine profile opening areas, add burner displacement areas (Ft 2 /section) from Table 1 for your complete burner assembly to "Net Free Area" of your duct: "Net Free Area" of Duct (Ft 2 ) = Fan Volume (SCFM) Velocity (SFPM) Net Free Area (Ft 2 ) + Burner Displacement (Ft 2 ) = Profile Area (Ft 2 ) Various duct size/profile area relationships may give slightly different field site data than is shown in Table 2. Velocities should always be confirmed and established by use of a velometer on actual field site installation. Table 1: Velocity Factors Table 1: Burner Section Displacement 2 ( ft /section) Inlet Feed Limitations: NP-I NP-II NP-III RG-IV 1-1/4" end 4' 4' 2000 4' inlet flange KBtu/hr 1-1/2" back 5' 5' 4500 5' inlets* KBtu/hr *Note: For 36 back inlet sections, not more than 6" off any one leg Pilot Capacities: Nominally rated at 25,000 Btu/hr with natural gas differential pressures of 4-6" w.c. Desired velocity across burner at profile plate opening (SFPM) 1600 1800 2000 2200 2400 2600 2800 3000 3250 3500 3750 4000 4500 5000 Appoximate velocity pressure reading at profile plate ("wc) 0.16 0.20 0.25 0.30 0.36 0.42 0.49 0.57 0.64 0.77 0.88 1.00 1.26 1.55 NP RG 6" Straight 0.25 0.33 12" Straight 0.50 0.66 18" Straight 0.75 0.99 24" Straight 1.00 1.32 12" Back Inlet 0.50 0.66 36" Back Inlet 1.20 1.50 12" x 6" Tee 0.60 0.75 6" x 6" Elbow 0.45 0.60

Series "NP" AIRFLO Burners Page 5507 Approximate Envelope Dimensions (Nominal, in Inches) Burner Sections (All burners shown are available in NP-I, II or III versions. Use one of these numbers (I, II or III) in place of asterisk (*) in burner designation when ordering.) NP- * -6 6" Straight or 6"P Pilot NP- * -12 or NP- * -12B 12" Straight or 12B Back Inlet NP- * -18 18" Straight NP- * -24 24" Straight NP- * -L 6" X 6" Elbow NP- * -T 12" X 6" Tee NP- * -36B 36B Back Inlet Typical End View 4/95

Page 5508 Series "NP" AIRFLO Burners Pilots, End Closures, and End Inlet Flange Sets NOTE: All open ends of burner assembly must be closed off with one of these end closures or pilots. One-piece cast end closures should not be used if temperature rise exceeds 300 F. Plain End Closure Sets End Inlet & Pilot Flange Sets NP-EC (1 pc) End Closure Set Pilot End Plate Sets NP-EP (2 pc) End Plate Set NPF- 1-1/4" -FR-SI (1 pc) Pilot Set w/si NPF- 1-1/4"- EP (2 pc) End Inlet Flange Set NPF- 1-1/4"- FR-SI (2 pc) Pilot Set w/si NP-Pak Pilot Set w/si NP-Pak Pilot Set w/adj. Orifice/SI Common Dimensions (Nominal, in Inches) Typical End View NP-Pak Pilot Set w/orifice/cock/tube/ SI NP-EC-SI-3/4"UV (1 pc) Pilot Set w/ SI NP-EC-SI-1/2"-FR (1 pc) End Closure Set w/si Pilot Assembly Section NP-6P Pilot Section w/built-in Pilot includes end plate pilot w/si onto its own special 6" Series NP AIRFLO Burner assembly PIpe threads on this page conform to NPT (ANSI Standard B2.1) Legend: 1-1/8" test connection 2-1/4" pilot gas connection 3-14mm spark ignitor connection 4-1/2" or 3/4" UV/FR connection bushed to 1/4" for FR 5 - Alternate 1/4" angled FR location 6-1/8" pilot gas connection 7-1-1/4" NPT gas inlet

Series "RG" AIRFLO Burners Page 5509 Burner Sections Approximate Envelope Dimensions (Nominal, in Inches) RG-IV-6 6" Straight or 6"P Pilot RG-IV-12 or RG-IV-12B 12" Straight or 12B Back Inlet RG-IV-18 18" Straight RG-IV-24 24" Straight RG-IV-L 6" X 6" Elbow RG-IV-T 12" X 6" Tee RG-IV-36B 36B Back Inlet Typical End View 5/88

Page 5510 Series "RG" AIRFLO Burners Pilots, End Closures, and End Inlet Flange Sets NOTE: All "open" ends of burner assembly must be closed off with one of these end closures or pilots. One piece cast end closures should not be used if temperature rise exceeds 300ºF. Plain End Closure Sets End Inlet & Pilot Flange Sets RG-EP (2 pc) End Plate Set RGF- 1-1/4" -FR-SI (1 pc) Pilot Set w/si RGF- 1-1/4"- EP (2 pc) End Inlet Flange Set RGF- 1-1/4"- FR-SI (2 pc) Pilot Set w/si Pilot End Plate Sets Pilot Assembly Section RG-6P Pilot Section w/built-in Pilot includes end plate pilot w/si and a special 6" Series RG AIRFLO Burner assembly RG-Pak Pilot Set w/ RG-Pak Pilot Set w/ SI Adj. Orifice/SI RG-Pak Pilot Set w/orifice/cock/tube/si Common Dimensions (Nominal, in Inches) Typical End View Legend: 1-1/8" test connection 2-1/4" pilot gas connection 3-14mm spark ignitor connection 4-1/2" UV/FR conn. bushed to 1/4" for FR 5 - Alternate 1/4" angled FR location 6-1/8" pilot gas connection 7-1-1/4" NPT gas inlet Pipe threads on this page conform to NPT (ANSI Standard B2.1)

"NP" & "RG" AIRFLO Burners Page 5511 Accessories / Replacement Items Dimensions, Nominal in Inches 14mm Spark Ignitor Profile Plate Bracket Provides support for profile within closed burner loop. 1/4" dia. Flame Rod (1/4" NPT) Adjustable Orifice Support Bracket Division Plate Provides isolation of burner feed where desirable. Normally used in pairs as shown here. Mount to burner assembly at any joint. External Mounting Assembly Frequently used to provide easy accessibility to spark ignitor and flame supervision components. External Mounting Plate Used with typical pilot Opening Required Includes Mounting Plate with two (2) feed-through insulators for internal mounting of Spark Ignitor and Flame Rod. 5/88

Page 5512 Notes "NP" & "RG" AIRFLO Burners