MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

Similar documents
MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

THE INSIDE STORY OF THE QPV OR MPV:

GP1/GP2 INSTALLATION & MAINTENANCE INSTRUCTIONS

ELECTRONIC CONTROLLER

THE INSIDE STORY OF THE QPV OR MPV:

Data Sheet. I/P and E/P converters. RS stock numbers ,

Miniature I/P, E/P Transducer

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Table of Contents. Proportional & Precision Regulator Instrumentation

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

SETRA Operating Instructions Series DPT 230 Pressure Transducers

EQUIVALENT BASIC CIRCUIT

VSO Thermally Compensated Proportional Valve

Sentronic PLUS 614 Series

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve

Electropneumatic Transducer

Miniature Proportional Valves Precision Fluidics

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Precision Regulators.

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Numatics 2003 Rev. 11/03 PDFPRECISION-1

Features and Benefits

The Series I/P Current to Pressure Transducer

Product Catalog Pressure Regulators. Proportional Valves

INSTALLATION AND OPERATION MANUAL

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Sentronic D 608 Series and 609 Series

Electropneumatic Transducer (I/P, E/P)

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

SSI Technologies MediaSensor

Precision Control Devices

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

MS4525 SPECIFICATIONS

Section 2 Proportional Quick Exhaust

VSO - MI thermally compensated proportional valve

Position Control Hard chrome-plated carbon steel piston rod with blackened threads and wrench flats Sintered bronze rod bushing Internally lubricated

AMETEK Model PPC Series Electronic Pressure Calibrator

Figure 1: WPR2 Dimensions and Hardware

3/3-Way-Proportional Valve

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Type Type 1001 Transducers. I/P & E/P Transducers

Models 415 & 425. Electronic Pressure Regulators. Customer Value Proposition: Contact Information:

INSTRUCTION MANUAL. TEC Controller/Thermocouple Thermometer

Servotronic Digital 615 Series

Sentronic LP 617 Series

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

Miniature Pneumatic Solenoid Valve

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

MPT SERIES OPERATING MANUAL. Caution: To Operate this controller safely, use the Safe Operating Area Design Tool Online at

Type 2000 Transducer Product Instructions

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

E22 Proportional Technology

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

C1 Controller & Driver. User s Guide

MODEL 900 IMPELLER-TYPE FLOW METER

LTX RF LEVEL SENSOR. Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

B SERIES. Bulletin B-2017

Materials: 10. Technical Data. VMAA Smart Pump Installation & Maintenance. Table of Contents

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

RESISTIVITY MONITOR/CONTROLLERS

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Electro-Pneumatic Regulator Electronic Vacuum Regulator

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

IOM A-0984E IP68-420DC AUTOMATED PILOT ACTUATOR Installation and Operation Manual

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

Reference Manual FM-200 Series

Pirani Vacuum Gauges. Digital and Analog Vacuum Gauge Systems. Features and Benefits. HPS Products (800) (303)

Transcription:

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MPV1 series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional to an electrical command signal input. The MPV1 is a complete closed loop control valve consisting of valves, manifold, and electronic controls. Pressure is controlled by the use of two solenoid valves. One valve functions as inlet control, the other as exhaust. The MPV1 output pressure is proportional to the voltage supplied by the control circuit. The proportional valve operates proportionally to the flow required to maintain that pressure. The variable orifice in the proportional valve allows precise control of pressure at low flow conditions and avoids the digital steps of traditional ON/OFF solenoids. The exhaust solenoid is a traditional ON/OFF solenoid and allows excess media to be vented from the system. The pressure output is measured by a pressure transducer internal to the MPV1 and provides a feedback signal to the electronic controls. This feedback signal is compared with the command signal input. A difference between the two signals causes one of the solenoid valves to open, allowing flow in or out of the system. Accurate pressure is maintained by controlling these two valves. A monitor output is provided for the system measurement. All MPV1 valves come standard with a 0-10Vdc analog monitor output from the internal pressure transducer. The MPV1 is designed to have "Universal Mounting" capabilities which include DIN rail, panel mount, or manifold mounting for use on a sub-base for multiple unit applications. Sub-base configurations are available from 2-12 units (consult factory for more units). The sub-base offers a common supply and exhaust port with individually controlled outlet ports to minimize plumbing connections and maximize installation/maintenance efficiency. PANEL MOUNT DIN RAIL MOUNT MANIFOLD MOUNT 1/8 INMPV1

SPECIFICATIONS MIN TYP MAX TERM ELECTRICAL Supply Voltage 15-24 Vdc Supply Current 70-350 ma max Command Signal Voltage 0-10 Vdc Command Signal Impedance Voltage - 10 - K Ohms Monitor Signal 0-10 Vdc @ 10mA PHYSICAL Operating Temperature 32 (0) - 158 (70) F ( C) Weight per unit (sub-base not included) - 0.7 (0.3) - Lb (Kg) MECHANICAL Pressure Ranges 29.9 in. Hg (vac) ² 760 mm Hg (vac) - - 100 6.89 Max. Cv Capacity - - - ¹ Min. Closed End Volume - 1 (17) - in³ (cm³) Filtration Recommended 40 - - micron Hysteresis - +0.02 +0.4 % F.S. ³ Repeatability - +0.02 +0.2 % F.S. Accuracy / Linearity - +0.2 +0.5 % F.S. Resolution - +0.02 +0.2 % F.S. Temperature Effect - +1 - % F.S. 4 Wetted Parts Elastomers..Fluorocarbon, Nitrile Manifold.Brass Valves.Nickel plated brass P. Transducer...Silicon, Aluminum, RTV ¹ Determined by the size of the inlet valve orifice size (see ORDERING INFORMTION). ² MPV1 units for vacuum only service are designed to provide pressure control of a vacuum level that is linearly proportional to an analog electronic command. Vacuum only service units always provide a higher level of vacuum for a higher analog command. A typical example is 4-20mA = 0-20in Hg vacuum, where 4mA gives 0in Hg and 20mA gives 20in Hg vacuum. ³ Hysteresis approaches zero when under flow conditions. For closed system, the hysteresis is dependent on the system and the valves settings. 4 Over range 0 to 50 degree C Before you get started, please read these warnings: Psig Bar Examine the product. Ensure that you received what you ordered. Read this guide first before you start and save it for later use. You must have a good understanding of what the adjustments are on this product before using them. All compressed air and power should be shut off before installing, removing or performing maintenance on this product. Installation and use of this product should be under the supervision and control of properly qualified personnel in order to avoid the risk of injury or death. 2/8 INMPV1

DIN Rail Mount MPV1 CONNECTION PROCEDURE Panel Mount Mounting The DIN rail MPV1 servo valve comes assembled to a DIN rail with a universal foot to allow all modules to be snapped onto all available DIN footprints: Mounting The panel mount MPV1 servo valve can be assembled to a panel by inserting two 8-32 socket head cap screws into the manifold and torque each screw into the panel (figure 3). Figure 3 Pneumatic Connections 1. Apply a small amount of anaerobic sealant to the male threads of the in-line filter supplied with the MPV1. Panel Mount Figure 1 Pneumatic Connections 1. Apply a small amount of anaerobic sealant to the male threads of the in-line filter supplied with the MPV1. 2. Connect supply pressure to the I port (figure 2) not to exceed rated supply pressure. (See table 1) 3. Connect the outlet O port (figure 2) to the device being controlled. 4. Proceed with electrical connection. DIN Rail Mount Figure 2 2. Connect supply pressure to the I port (figure 4) not to exceed rated supply pressure. (See table 1) 3. Connect the outlet O port (figure 4) to the device being controlled. 4. Proceed with electrical connection. Figure 4 TABLE 1 RATED INLET PRESSURE FOR STANDARD MPV1 VALVES For valves ordered with MAX. calibrated pressure MAX. inlet pressure Vacuum up to 10 psig (0.69 bar) 15 psig (1 bar) 10.1 up to 30 psig (0.70 up to 2 bar) 35 psig (2.4 bar) 31 up to 100 psig (2.1 up to 7 bar) 110 psig (7.6 bar) 3/8 INMPV1

MPV1 Manifold Mounting: Installation: 1. Install the three O-rings in the O-ring grooves of the sub-base manifold. (figure 5, ref E) 2. Align the MPV1 servo control valve over the three O-rings. Orientation of the MPV1 unit should be the same for all MMs on the manifold and can be determined by the I and E marks on the MPV1 brass manifold and the aluminum sub-base manifold (figure 5, ref item H). 3. Insert the two cap screws that hold the servo valve to the sub-base manifold. Torque each screw to 8 in-lbs and then torque each cap screw to 13-15 inlbs (figure 5, ref item D). 4. To install the sub-base manifold to a panel use 1/4-20 socket head mounting screws (figure 5, ref item A). Removal: 1. Disconnect supply air and the electrical connector from the MPV1 servo valve to be removed. 2. Remove the cap screws that mount the MPV1 servo valve to the sub-base manifold (figure 5, ref item D). 3. The MPV1 servo valve may now be lifted free of the sub-base manifold. Be careful to retain the three O-rings in their grooves on the sub-base manifold (figure 5, ref item E). Figure 5 Pneumatic Connections 1. Connect supply pressure to the I port (figure 5, ref item H) not to exceed rated supply pressure. (See table 1) 2. Connect the O port (figure 5, ref item B) to the device being controlled. 3. Proceed with electrical connection. Vacuum Only Units Pneumatic Connections 1. Apply a small amount of anaerobic sealant to the male threads of the in-line filter supplied with the MPV1. 2. Connect vacuum supply to the E port (figure 6). Vacuum Supply 3. Connect supply pressure to the I port (figure 6) not to exceed rated supply pressure (See table 1) or leave it open to atmosphere. 4. Connect the outlet O port (figure 6) to the device being controlled. 5. Proceed with electrical connection. Figure 6 To Application Atmospheric or Slightly Positive Pressure 4/8 INMPV1

Electrical connections 1. Ensure all power is off before making any electrical connections. 2. Figure 7 shows the location of the MPV1 electrical connector and Table 2 identifies each connection. 3. See figure 8 for voltage command wiring, and figure 9 for voltage monitor wiring. Voltage command valves: All voltage command MPVs use common mode voltage, meaning the DC Common pin is the common reference for both power and command. Figure 8 shows the proper connections. Figure 7 Figure 8 Voltage monitor: See figure 9 for voltage monitor feedback signal wiring. Figure 9 5/8 INMPV1

RE-CALIBRATION PROCEDURE : All MPV1 control valves come calibrated from the factory by trained personnel using precision calibration equipment. The QPV valve is a closed loop control valve using a precision electronic pressure sensor. Typical drift is less than 1% over the life of the product. If your MPV1 valve appears to be out of calibration by more than 1%, it is not likely to be the MPV1. Check the system for adequate supply pressure, wiring and electronic signal levels. Verify the accuracy of your measuring equipment before re-calibrating. Consult factory if you have any questions or require assistance. If the MPV1 valve needs re-calibration, use the procedure described below: MPV1 VALVES: NOTE: There must be a closed volume of at least 1 cu.in. (17cc) between the valve outlet and the measuring device for the valve to be stable. MPV1 valves work best when there is a small leak downstream. 1. Wire control valve according to the section titled Electrical Connections. 2. Connect a precision measuring gauge or transducer to the outlet port of the MPV1. 3. Plumb control valve according to section titled Pneumatic Connections. Make sure supply pressure does not exceed the rating for the valve (see table 1). 4. On the printed circuit board, locate the two adjustment potentiometers labeled P-S (span adjust) and P- Z (zero adjust). (See figure 12) NOTE: The MPV1 uses an advanced analog PID circuit to modulate the internal solenoid valves. These four potentiometers (Proportional, Integral, Bias and Exhaust Trip Point) are set at the factory and should not require adjustment. These settings are based on the specific parameters of your application. If the response of the MPV1 requires adjustment, contact the factory for special instructions. Figure 12 PID SETTING Should not require adjustment. Set at the factory based on specific parameters of your Application. 5. Set the electrical command input to MAXIMUM value. 6. Adjust the SPAN potentiometer until MAXIMUM desired pressure or vacuum is reached (clockwise to increase pressure). 7. Set the electrical command input to 10 percent of full value (1Vdc for 0-10Vdc unit ). 8. Adjust the ZERO potentiometer until 10 percent of maximum desired pressure or vacuum is reached. (clockwise increases pressure). 9. The ZERO and SPAN potentiometers interact slightly. Repeat steps 5-8 until no error exists. 10. Verify unit shuts off by going to zero command. Check linearity by going to at least six setpoints throughout the full range. NOTE: Only use this step if your device is totally out of calibration. If it is slightly out of calibration, omit this step and move on to paragraph 5. Using a small screwdriver, turn both potentiometers 15 turns clockwise. Then turn them 7 turns counter clockwise. This will put the MPV1 roughly at mid scale. 6/8 INMPV1

DIMENSIONS Panel Mount MPV1 DIN Rail MPV1 MANIFOLD MOUNT 7/8 INMPV1

ORDERING INFORMATION MPV 1 M B F E E 100 G X Sxx SERIES MODEL 1 = SINGLE LOOP MOUNTING METHODS M = MANIFOLD MOUNT P = PANEL MOUNT D = DIN RAIL MOUNT PID SETTING MONITOR B = BSPT BLANK = NPT COMMAND INPUT E = VOLTAGE 0-10 VDC MONITOR SIGNAL E = 0-10VDC MAXIMUM CALIBRATED RANGE EXAMPLES 100 = 0-100 PSI 001 = 0-1 PSI N20= atm-20 in Hg Vacuum * Pressure ranges not starting at 0 psig are available. Consult factory for ordering information. INLET VALVE ORIFICE SIZE EXHAUST VALVE FACTORY DETERMINED (Depends on the application flow & pressure specs) EXAMPLE A = 0.013 B = 0.025 C = 0.040 D = 0.060 SPECIAL OPTIONS* * Consult Factory for Special Options Cx REQUIRED FOR ALL MPV VALVES Factory determined based on the specifications of the application DIN RAIL MOUNT KIT DRMKT-01 PANEL MOUNT KIT PMK-MM SUB-BASE MANIFOLD* SBM-5 NUMBER OF MOUNTING POSITIONS SUB-BASE ASSEMBLY ASSEMBLE5MM NUMBER OF MM VALVES TO ASSEMBLE * For a British pipe thread sub-base add BSPP (i.e. SBM-5-BSPP). Proportion-Air products are warranted to the original purchaser only against defects in material or workmanship for one (1) year from the date of manufacture. The extent of Proportion-Air's liability under this warranty is limited to repair or replacement of the defective unit at Proportion-Air's option. Proportion-Air shall have no liability under this warranty where improper installation or filtration occurred. All specifications are subject to change without notice. THIS WARRANTY IS GIVEN IN LIEU OF, AND BUYER HEREBY EXPRESSLY WAIVES, WARRANTIES OR LIABILITIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY OBLIGA- TION OF PROPORTION-AIR WITH REGARD TO CONSEQUENTIAL DAMAGES, WARRANTIES OF MERCHANTABILITY, DESCRIP- TION, AND FITNESS FOR A PARTICULAR PURPOSE.... WARNING: Installation and use of this product should be under the supervision and control of properly qualified personnel in order to avoid the risk of injury or death. PROPORTION-AIR, INC. BOX 218 MCCORDSVILLE, IN USA 46055 PHONE (317)335-2602 FAX: (317)335-3853 web site: www.proportionair.com email address: info@proportionair.com 8/8 INMPV1