Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Similar documents
Fiber Connector Shelf (CCS)

Environmental Distribution Center (EDC-06P-NH)

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

8400 Series Fiber Distribution System

INSTALLATION INSTRUCTIONS

FIBER CONNECTOR SAFETY WARNINGS

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

COYOTE STP (Service Termination Point)

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Instructions for Use - Opt-X 1000i Enclosure

Fiber optic splice closure

COYOTE STP (Service Termination Point)

INSTALLATION INSTRUCTIONS

Opticom Rack Mount Fiber Enclosures

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Fiber Optic Splice Module

Universal Splice Tray Installation Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

FL2000 Termination/Splice Panels User Manual

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

Fiber Splice Panel Rack Mount User Manual

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Installation Instructions Part Number

PanView iq (PViQ) Fiber Tray

12-Inch Hybrid Fiber Access Terminal Installation Instructions

CS Fiber Optic Splice Case. Instruction

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

COYOTE LCC (Low Count Closure)

Air Conditioner for M915 A0/A1 Truck

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

LEXUS GX TOWING HITCH Preparation

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

FlexJet - Flex Cable Replacement

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

LPE C5 Battery Relocation Kit

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

STANDARD STEEL PLOW BLADE ASSEMBLY INSTRUCTIONS

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

C Power Connection Kit

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

COYOTE Terminal Dome Closure 6.5" x 22"

FOSC-400A4 INSTALLATION INSTRUCTION

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

PONTIAC FIREBIRD

Plug & Play AnyLAN Systems

USER'S MANUAL and INSTALLATION GUIDE

WOC & WOC Top & Back Installation Instructions

LEXUS GS 350/450h ILLUMINATED DOOR SILLS Preparation

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SPORT/UTILITY BLADE ASSEMBLY INSTRUCTIONS

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Instruction, EDGE8-04U Quick Start Guide

TOYOTA im INTERIOR LIGHT KIT Preparation

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

SMART ELECTRIC TAILGATE LIFT SYSTEM Document # Created ACH 09/19/2018 Revised ACH 10/02/18 A2

Installation Instructions

WAVETRAX USER MANUAL

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

INSTALLATION & OWNER S MANUAL

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

Installation Instructions

3M Fiber Dome Closure FDC 10

INSTALLATION & OWNER S MANUAL

Power Connection Kit installation instructions

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

INSTALLATION INSTRUCTIONS

INSTALLATION & OWNER S MANUAL

PFadvantage JD 3300/4400/6600/7700; 4420

INSTALLATION INSTRUCTIONS

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SUT-250-S (These instructions are used for SUT-250-SCLC also)

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

GENUINE PARTS INSTALLATION INSTRUCTIONS

Transcription:

1. Precautions 2. Carton Contents Pretium Wall-Mountable Housing OR Fiber Zone Box (FZB-02P-JB) PWH-02P and FZB-02B-JP have: (15 inches) edge grommet (1) Laser warning label (2) Fiber identification labels (1) 8-32 lock nut (1) M6 washer (3) 1/8 x 4-inch cable ties (1) U-shaped washer PWH-04P/-06P/-12P have: (15 inches) edge grommet (1) Laser warning label (6) Fiber identification labels (1) 10-24 wing nut (1) 10-25 x 0.75 in carriage bolt (2) M6 washers (3) 1/8 x 4-inch cable ties (1) U-shaped washer 3. Tools and Materials Required Phillips-head screwdriver Slotted screwdriver 5/16-inch (8 mm) socket or wrench STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 1 OF 8 Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB) p/n 003-724, Issue 5 CAUTION: Cleaved or broken glass fibers are very sharp and can pierce the skin easily. Do not let these pieces of fiber stick to your clothing or drop in the work area where they can cause injury later. Use tweezers to pick up cleaved or broken pieces of glass fibers and place them on a loop of tape kept for that purpose alone. Good housekeeping is very important. WARNING: DO NOT use magnifiers in the presence of laser radiation. Diffused laser light can cause eye damage if focused with optical instruments. Should accidental eye exposure to laser light be suspected, arrange for an eye examination immediately. WARNING: Never look directly into the end of a fiber that may be carrying laser light. Laser light can be invisible and can damage your eyes. Viewing it directly does not cause pain. The iris of the eye will not close involuntarily as when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. Should accidental eye exposure to laser light be suspected, arrange for an eye examination immediately. Entry Grommet Strain-relief Bracket Radius Control Guides KPA-0174 NOTE: Knockout (located on back wall of housing) Front Door Restraint Strap (stored location) Blank Adapter Panel (Remove by squeezing tabs together and lifting panel away from opening.) Jumper Routing Guides Cable Inlet Plug Side Door The components you receive may vary from those depicted depending upon the configuration ordered for your specific application. 11/32-inch (9 mm) socket or wrench Needle-nosed pliers Pencil, pen or marker PRETERMINATED SYSTEMS CABLES CONNECTORS CABLE ASSEMBLIES HARDWARE TOOL KITS AND ACCESSORIES TEST EQUIPMENT SPLICE EQUIPMENT FAN-OUT KITS TRAINING

4. Additional Materials (Purchased Separately) May or may not be required depending on your application Connector Panels (CCH-CPXX-YY) Mounting hardware appropriate for your installation Grounding kit (HDWR-GRND-KIT) for armored cable Buffer Tube Fan-Out kits (FAN-XX25-YY) Pigtailed Panels (CCH-CPXX-YY-P03ZZ) Pigtailed Modules (CCH-RMXX-YY-P03ZZ) Splice tray bracket (PWH-SPLC-02P/-04-12P) Reduced Length Splice Trays External Strain-Relief (PWH-STRNRLF-KIT) Plug & Play trunk strain-relief bracket (PWH-RJSR) Hardware locking kit (HDWR-LOCK-KIT) 5. Mounting The PWH may be mounted directly to a wall. An optional wall standoff kit, (purchased separately), may be used for mounting to allow cable routing between the cabinet and the wall. The wall standoff kit may be installed following instructions provided with the kit. When mounting the PWH directly to a wall, select a vertical surface. The surface should be flat so that the PWH won t warp when it is secured to the wall. Hold the unit in position on the wall and mark the hole locations with a pencil, pen, or marker. PWH-02P/-04P/-06P PWH-12P Mounting Screws Not Provided TPA-3021 Mounting holes for the -02P units are: L : 12 in (30.48 cm) H: 7 1/4 in (18.42 cm) Mounting holes for both the -04P and -06P units are: L : 16 in (40 cm) H: 11 1/8 in (28.26 cm) Mounting holes for the -12P units are: L : 16 or 24 in (40.6 or 61 cm) H: 11 1/8 in (28.26 cm) Drive anchors or wood screws in at these locations leaving a 1/8-inch gap between the mounting surface and screw or bolt head. Hardware used for mounting depends on the mounting surface. Place the unit on the mounting hardware and tighten the hardware. STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 2 OF 8

5.1. On a Slack Storage Housing Remove the knockouts from the front of the SSH and from the rear of the PWH to allow cable to be routed from the SSH to the PWH. Install screws in the locations leaving a 1/8-inch gap between the screw head and the SSH. Hang the PWH on the screws and tighten the screws. 5.2. Below a Raised Floor (ONLY Applicable to FZB-02P-JB) Only FZB-02P-JB meets Underwriter Laboratories approval for installation below a floor. Select an installation location and remove five adjacent floor tiles in a + pattern. The unit will be installed in the center of the +. Remove stringers (not shown) from the tile location where the unit will be installed. These will be replaced after the unit is installed below the level of the stringers. The bottom of the unit will rest on the substructure; be sure there is enough depth for the top of the unit to be below the stringers. KPA-2297 6. PWH Center Door The unit s center door can be opened and secured at a 90 degree angle by attaching the cable from it to the housing. Avoid putting excessive weight on the door when using it as a shelf; doing so may cause the door to bend or break. It is possible to close the door without disconnecting the cable. When closing, make sure the cable doesn t get caught between the door and the housing or interfere with the fibers or connectors. 7. Installing Cable NOTE: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the cable specification sheet for the cable you are installing. Do not bend the cable more sharply than the minimum recommended bend radius. Do not apply more pulling force to the cable than specified. Do not crush the cable or allow it to kink. Doing so may cause damage that can alter the transmission characteristics of the cable; the cable may have to be replaced. Pierce the grommet in the top or bottom of the housing and thread the cable through the hole. Grommet Preparation Use a pair of needle-nose pliers or sharp pencil to pierce the grommet. Do not use a knife or cutters. Grommets must fit tightly to prevent the intrusion of insects, water, dirt, or foreign particles. A knife may cut all the way through the grommet, and cutters may cut a hole that is too large for a tight fit. TPA-3022 STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 3 OF 8

7.1. Installing Cable Using Plug & Play System Connector Modules Internal strain-relief is dependent upon the outside diameter of the cable furcation plug; when the plug is too large (greater than size 2) to fit through the cable entry grommet, a separate strain-relief bracket (p/n PWH-RJSR, purchased separately) is required. The internal bracket will hold up to two size 0 furcation plugs or one size 1 plug. Choose the strain-relief location and routing configuration that best fits your application. Feed the fiber leg with the MTP connector and the cable furcation plug through the appropriate grommet. Insert the feet of the mounting clip into the square mounting holes on the strain-relief bracket. Slide the Plug & Play System connector module into the telco compartment from the premises side of the unit. Secure the module with the nylon fasteners. Loosely route the MTP connector fiber leg around the radius control guides and plug the connector into the back of the connector module. The fiber routing configuration is dependent upon the mounting location of the furcation plug on the cable. Alternate Mounting Location KPA-0177 7.2. Installing cable to be spliced or connectorized 7.2.1 Cable access Perform cable sheath removal steps as specified in instructions for the cable you are installing. Suggested lengths are illustrated. Central Member: 4 in (10 cm) Buffer tube fan-out applications Central Member: 4 in (10 cm) Buffer: 54 in (137 cm) Bare fiber: 35 in (89 cm) Tight-buffered fiber: 56 in (142 cm) Yarn: 8in (20 cm) TPA-3023 Total access: 89 in (226 cm) TPA-3027 Yarn: 8 in (20 cm) Pigtail splicing applications Pigtails: 90 in (229 cm) (plus slack required inside tray) Splice tray Buffer: 54 in (137 cm) Central Member: 4 in (10 cm) TPA-3031 Total access: 104 in (264 cm) Yarn: 8 in (20 cm) STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 4 OF 8

TPA-2945 7.2.2 Strain-relief IMPORTANT: If you are installing outside plant cable or temperature fluctuates widely along any part of the cable, the strength members of the cable must be strain-relieved. Failure to do so may result in damage to the cable as temperature varies. Other situations only require the cable to be strain-relieved by sheath retention only. Cable sheath strain-relief Trim strength member and aramid yarn flush with the outer jacket. NOTE: Secure the cable to the strain-relief bracket with two cable ties. If external cable sheath strain-relief is required, purchase PWH-STRNRLF-KIT and follow the instructions provided. Strength member strain-relief PWH-02P PWH-04P/-06P/-12P Secure the cable to the strain-relief bracket with two cable ties. Secure the cable to the strain-relief bracket with two cable ties. Wrap the aramid yarn around the top stud for bottom entry or bottom stud for top entry in a clockwise direction. Insert the carriage bolt through the strain-relief bracket and wrap the aramid yarn around it in a clockwise direction. Install the U-shaped washer onto the stud. Install the U-shaped washer, two flat washers and the wing nut as shown. Step 4: Step 5: Step 6: Insert strength member on top of the U-shaped washer. Place the flat washer over the strength member and secure with Central Member the locknut. Trim excess aramid yarn and strength member. Aramid Yard Flat Washer TPA-2944 U-shaped Washer Step 4: Step 5: Step 6: Insert the strength member between the U-shaped washer and the first flat washer. Tighten wing nut. Trim excess aramid yarn and strength member. U-shaped Washer Yarn Round Washer Central Member STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 5 OF 8

7.3. Installing Cable Using Buffer Tube Fan-out (BTF) Kits Step 4: Step 5: Access the cable as specified for the cable you are installing. Install the BTF assemblies (p/n FAN-XX25-YY, purchased separately) on the buffer tubes as described in the instructions supplied with the BTF kits buffer tube. Loop the buffer tube once around the radius control guides and slide the BTF body into the strain-relief bracket. Install a cable tie to secure the body. Route the connectorized fibers behind the plastic tabs on the radius control guides. Remove blank panels and install connector panels. Cable tie Cable tie KPA-0182 Plunger Pull the plunger out of the fastener so that the fingers collapse. Push in the plunger so that the fingers expand and lock the panel to the housing. Housing Insert the fastener into hole in the housing. To remove, pull the plunger out. TPA-3025 Expanded Fingers Step 6: Once the connectors have been terminated, route the fiber using the routing pattern illustrated. Connectorized cables TPA-3026 Step 7: Remove dust caps from the connectors and adapters into which they will be mated. Clean the connector end faces and the adapter per standard company practices. Mate the connectors in the adapters. STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 6 OF 8

7.4. Installing Cable from a Slack Storage Housing (SSH) Use a can nut driver to open the door of the SSH unit and access the fibers in it. Bring the fibers from the SSH unit into the wallmount housing through the knockout openings and carefully secure the door of the SSH unit in the closed position. Connectorize the fibers and route them behind the plastic tabs on the radius guides. Step 4: Refer to Section 7.3, Steps 5-7. KPA-0825 7.5. Installing Cable Using Reduced Length Splice Trays A splice tray bracket kit (p/n PWH-SPLC-02P/-04-12P, purchased separately) is required to install splice trays. Follow instructions provided with the splice tray bracket kit. 7.5.1 Install Splice Tray Temporarily position the splice tray in the holder to determine adequate fiber slack. Route Buffer Tubes Route the buffer tube in a counterclockwise direction around the radius control guides to the splice tray. Mark the cable where it will enter the splice tray. IMPORTANT: If the cable enters the PWH from the bottom, route the buffer tube in a clockwise direction around the radius control guides. KPA-0311 Route Pigtail Fibers Remove the blank panels from the PWH by squeezing the tabs together and lifting the panel away from the opening. Install factory-pigtailed panels or modules. Route pigtails in a counterclockwise direction around the radius control guides to the splice tray. Mark the pigtail where it will enter the splice tray. KPA-0312 IMPORTANT: If the cable enters the housing from the bottom, route the pigtail around the guides in a clockwise direction. STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 7 OF 8

TPA-3035 7.5.2 Splice This procedure is to be used in conjunction with the instructions provided with the splice tray. Step 4: Step 5: Step 6: Follow instructions provided with the splice tray to remove cable buffer and jacket and secure them to the splice tray. Move the splice tray and fibers to the splicing equipment. Splice fibers as described in the instruction provided with your splicing equipment. Route fiber slack around the radius control guides. Install the splice tray into the holder. Swing the splice tray holder against the bracket and secure it to the bracket using the nylon fastener. Once all splicing is complete, secure the splice trays into the holder using the hook-and-loop strap. KPA-0313 8. Documentation Attach the labels provided in the hardware kit to the inside of the telco door. Record fiber identification information appropriately. Accurate recordkeeping is imperative to an organized installation. 9. Install Jumpers Remove dust caps from the connectors and adapters into which they will be mated. Clean connector end faces and adapters per standard company practices and insert connectors into adapters. Remove the cable inlet plugs. If desired, attach the provided edge grommet to the opening. Secure the jumpers in the routing clips in the premise compartment. Maintain appropriate bend radius. KPA-0183 10. Secure the Unit Close the center door and secure with the swell latch. Then close the side doors and ensure the slide latches engage to secure the doors. Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 1-800-743-2671 FAX +1-828-325-5060 International +1-828-901-5000 http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance, and modify the features and specifications of Corning Cable Systems products without prior notification. Pretium and Plug & Play are registered trademark of Corning Cable Systems Brand, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 2006, 2007, 2009, 2010, 2012 Corning Cable Systems. All rights reserved. Published in the USA. STANDARD RECOMMENDED PROCEDURE 003-724 ISSUE 5 June 2012 PAGE 8 OF 8