Underground Tank Applications Installation Guide

Similar documents
AUTOGAS 150 SERIES PUMPS INSTALLATION GUIDELINES FOR UNDERGROUND TANK APPLICATIONS

LIQUEFIED GAS PUMP INSTALLATION

Coro-Flo Sales Catalog

Installation, Operation & Maintenance Manual

IF102F Installation, Operation & Maintenance Manual Models 060, 075 and 150 Coro-Flo Pumps

Installation, Operation & Maintenance Manual

Solutions beyond products...

Corken Pumps. Corken Coro-Flo Regenerative Turbine Pumps. Corken C Series Coro-Flo Pumps. Corken F Series Coro-Flo Pumps

LPG-Series. Pumps and Compressors. For LPG and NH 3 Stationary Applications

Model Z4500 Stationary Pump

Z-Series. Coro-Vane Truck Pumps. For LPG, NH 3, and other Applications

Solutions beyond products...


LPG-Series. Compressors and Stationary Pumps for LPG and NH 3 Bulk Plant Applications. A Unit of IDEX Corporation.

D1AFF Fleet Fueling Dispensers

LPG-Series. Compressors and Stationary Pumps for LPG and NH 3 Bulk Plant Applications. Solutions beyond products... A Unit of IDEX Corporation

Technical Information

Quality Value Assurance

Sealless Magnetic Coupled Multistage Centrifugal Pumps with Priming Stage Type HZSM / HZSMB / HZSMR / HZSMA / HZSMAR

Appendix D Outline Dimensions for Model Z2000

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH

Regenerative Turbine Chemical Pumps for the Process Industry

PV Series Vane Truck Pumps

BLACKMER BYPASS VALVES

Industrial Pump Catalog

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

Installation, Operation, Repair and Parts Manual

Regenerative Turbine Pumps

Positive Displacement Pumps and Oil-Free Gas Compressors

Solutions beyond products...

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

Solenoid Operated Block Valves A2800 Series

Positive Displacement Pumps and Oil-Free Gas Compressors for Liquefied Gas Applications

AIR OPERATED OIL PUMPS AND KITS

Positive Displacement Pumps and Oil-Free Compressors for Liquefied Gas Applications

Contents Project: Model: Chk d: Date:

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

F20 Series. Maximum Flow Rate: 1.0 gpm (3.8 l/min) Maximum Pressure: 1500 psi (103 bar) for Metallic Pump Heads

Appendix D Outline Dimensions

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

AIR OPERATED OIL PUMPS AND KITS

OPERATOR S MANUAL A

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

DWO DWO DWO DWO

LIQUID-SPECIFIC PRODUCT LINE: STAINLESS STEEL VANE PUMPS PRODUCT DESCRIPTION SERIES OPERATING RANGE 1 NOMINAL FLOW RATES 2

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Lecture 6. Systems review exercise To be posted this weekend Due next Friday (3/6)

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Regenerative Turbine Pumps

SIHI prime - Side Channel Pumps Self-priming, segmental type

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

Tank Filling Systems. for Petroleum Products

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

D/G-04 Series. Up to 3.0 gpm (11.3 l/min)

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

Installation, Operation & Maintenance Manual

LPG Premier 21-Stage Pump Section LPG Premier MidFlow 17-Stage Pump Section LPG Premier HiFlow 24-Stage Pump Section

Minuteman Vertical Pumps

The Practical Pumping Handbook

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

Tank Filling Systems for Petroleum Products

MICROPUMP MAG-DRIVE GEAR PUMPS

Solutions beyond products...

MONITORS DESCRIPTION. Grease fitting for lubrication

Pumping Station. Marisa Handajani

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

Regenerative Turbine Pumps

G03 Mono-Block Series

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

Corken Compressor Repair

P239-1 Supply Pumper Instructions

Series

G04 Series. Maximum Flow Rate: 11.2 l/min (2.9 gpm) Maximum Pressure: 200 bar (2900 psi) for Metallic Pump Heads. G04 with Stainless Steel pump head

VIKING. Series LVP STAINLESS STEEL VANE PUMP. VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA 2016 PRODUCT DESCRIPTION SERIES OPERATING RANGE

So how does a turbocharger get more air into the engine? Let us first look at the schematic below:

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Describe the function of a hydraulic power unit

Earthsafe Systems, Inc. Page 1

Air Driven Gas Boosters

TYPE PC Propeller Condensate Pumps

Propane 101. Study Guide. Course Code: 8517

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

Chapter 2. The Vehicle-Tank Metering System

LEISTRITZ PUMPEN GMBH. Leistritz Screw Pumps & Systems L3MA 3 L. The new L3MA pump series according API 676 3rd. API 676 3rd. 6 3r

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

Regenerative Turbine Pumps

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

Hydra-Cell T80 Series Pumps Design Advantages

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Transcription:

IF Underground Tank Applications Installation Guide Coro-Flo Pumps

Background: Because of the environmental problems caused by traditional fuels such as gasoline and diesel, the use of alternative fuels, like LPG, are rapidly increasing worldwide. To reduce air pollution, many governments are adopting energy policies that promote the use of autogas. Since autogas is typically used in highly populated cities with air pollution problems, special safety measures and techniques have been implemented to improve the integrity and safety of the LPG dispensing stations. One of the techniques widely implemented is the use of underground storage tanks. The Challenge of Pumping LPG: The pumping of boiling liquids, like LPG and other liquefied gasses, offers a unique set of challenges to the manufactures and users of LPG pumps. Since LPG is stored at exactly its boiling point, any increase in temperature, as well as any decrease in pressure, will cause the product to boil and form vapor. To limit the amount of vapor formation at the pump s inlet port, the design of the suction piping system, is an important aspect. For boiling liquids, the net positive suction head available (NPSHA) of an installation is reduced to the height of the liquid level above the pump (net static suction head) minus the frictional losses. For an underground tank where the pump is located above the liquid level, the net static suction head becomes the net suction lift, which is negative, not positive. This means that for aboveground pumps pumping from underground tanks, the installation NPSHA will always be negative, and the pump will always handle vapor in the liquid stream. Over the years, several methods have been used, but each one of them not only complicated the pumping system, but also in many cases contributed to cavitation in the pump. Some examples are:. The use of a foot-valve, or a backpressure check valve at the end of the suction dip tube. This method is ineffective: eventually vapor will be formed in the dip tube when the pump is shut-off. Upon starting the pump, this vapor will be drawn into the pump, causing cavitation.. The Parkhill-Wade method developed in the 9 s, using a small receiver tank with an eductor at the pump s discharge port. Since this system must use a pump with a higher capacity than what the application requires, the pump cavitates continuously.. Padding the storage tank using a compressor, or a blanket of an inert gas.. Blowing down the vapor in the pump until the pump is primed with liquid. This requires venting product to the atmosphere, which is not a safe practice. Special design criteria must be incorporated in the design of LPG pumps, so the pump can effectively handle a certain amount of vapor, without suffering the destructive effects of cavitation.

Types of LPG Pumps: Submersible Pumps: Although these types of pumps have been used with some degree of success in the LPG industry, there are many disadvantages. Requires a special construction storage tank More expensive pump Special and costly protection system to avoid running the pump dry. Dry-run tolerances are very limited. Many of these pumps cannot be repaired (i.e., throwaway pumps) The pump s well must be evacuated in order to remove the pump for repairs or to be replaced. Due to its weight, the use of a crane is typically required to remove the pump from the tank s well before servicing the pump. Since some of the submersible pumps are integral pump/motor units, neither the pump nor the electric motor can be replaced separately. The complete assembly must be replaced. Positive Displacement (PD) Pumps: Positive displacement pumps such as piston pumps, gear pumps and sliding-vane pumps are widely used in the LPG industry due to their good suction characteristics and their vapor handling capability. However, when positive displacement pumps run dry, severe wear, increased noise and vibration will occur. Installation Design Criteria for Underground Tanks Applications: Minimize frictional losses: - Pump should be as close as possible to the tanks liquid outlet connection - Use a minimal number of fittings and elbows - No strainer is necessary since the tank itself acts as a gravity collector - Use full-port ball valves, or low restriction valves - Use at least the minimum piping sizes shown in the charts for figures. or. - Minimize the net static suction lift to approximately feet (. m) - Use vapor eliminator valves (Corken B by-pass valves have this feature) - Use back-pressure check valves downstream of the pump - Vent the vapor eliminator on the liquid meter back to the tank, not to the by-pass line - Limit the capacity of the pump to a maximum of.% of the tank s capacity. (For example, with a gallon (,78 liter) tank, limit the pump to gpm (.8 L/min) Regenerative Turbine Pumps: Unlike the positive displacement pumps, there is only one moving part, its impeller, which floats freely without metal-to-metal contact. Although this type of pump does not have the vapor handling capability of positive displacement pumps, they do move vapor more readily and have an excellent tolerance level for running dry without noise and vibration. Since a pump for an underground tank application will run dry until they are primed with liquid, these characteristics make the regenerative turbine pump, the pump of choice for an underground tank application.

. Underground Tank Application feet (, mm) maximum 7 9 8 Approximately feet (,7 mm) maximum Underground tank Minimum liquid level of inches ( mm) above end of dip tube Bill of Materials Ref. No. Description Size Remarks Model Model Model Model 9,,, Schedule 8 pipe / " -/" " Man way cover Existing Ball valve, full port / " -/" " Manual or remote control Corken pump 9, or or With 7. hp (. kw) electric motor /" NPT pressure gauge psig ( 8 bar g) Corken B by-pass valve inch NPT With spring code C 7 /" NPT hydrostatic relief valve Set at psig ( bar g) 8 In-line excess flow valve Closing flow of gpm (7 7 L/min) 9 Back pressure check valve Like Corken s Flo-Chek valve By-pass return line s valve Existing Eccentric reducer, if required WARNING: No excess flow valves on the tank s liquid outlet connections are shown in these schematics. If local regulations require the use of excess flow valves, its closing flow should be approximately. times higher than the pump s rated capacity for the operational conditions. Periodic inspection and maintenance of Corken products is essential. Only experienced, trained and qualified personnel must make inspection, maintenance and installation of Corken products. Maintenance, use and installation of Corken products must comply with Corken instructions, applicable laws and safety standards such as NFPA 8 for LP-Gas and ANSI K.-97 for Anhydrous Ammonia. Transfer of toxic, dangerous, flammable or explosive substances using Corken equipment is at the user s risk. Only qualified personnel should operate Corken equipment according to the applicable laws and safety standards.

. Underground Tank with Manifold for Submersible Pump 7 feet (, mm) maximum 8 9 Underground tank Approximately feet (,7 mm) maximum Minimum liquid level of inches ( mm) above end of dip tube Bill of Materials Ref. No. Description Size Remarks Model Model Model Model 9,,, Schedule 8 pipe / " -/" " " manifold Existing Ball valve, full port / " -/" " Manual or remote control Corken pump 9, or or With 7. hp (. kw) electric motor /" NPT pressure gauge psig ( 8 bar g) Corken B by-pass valve inch NPT With spring code C 7 /" NPT hydrostatic relief valve Set at psig ( bar g) 8 In-line excess flow valve Closing flow of gpm (7 7 L/min) 9 Back pressure check valve Like Corken s Flo-Chek valve " Ball valve Existing Eccentric reducer, if required " flange Existing Pressure equalizing line Part of existing " manifold. Must be open for pump to operate properly. By-pass return line s valve Existing WARNING: No excess flow valves on the tank s liquid outlet connections are shown in these schematics. If local regulations require the use of excess flow valves, its closing flow should be approximately. times higher than the pump s rated capacity for the operational conditions. Periodic inspection and maintenance of Corken products is essential. Only experienced, trained and qualified personnel must make inspection, maintenance and installation of Corken products. Maintenance, use and installation of Corken products must comply with Corken instructions, applicable laws and safety standards such as NFPA 8 for LP-Gas and ANSI K.-97 for Anhydrous Ammonia. Transfer of toxic, dangerous, flammable or explosive substances using Corken equipment is at the user s risk. Only qualified personnel should operate Corken equipment according to the applicable laws and safety standards.

DS-/DL/F-Model Performance Curves Differential Pressure vs Capacity All F-, DS-, DL-Models Flow vs. Power Required 7 88 RPM @ Hz Differential Pressure (bar) Model Model Model Model Model 7 Capacity (L /min) Flow vs. Differential Pressure RPM @ Hz Differential Pressure (psi) 7 Model 9 Model Model Model Model Model 8 8 8 8 Capacity (gpm) The performance curves are based on aboveground LPG installations. Performance curves for underground LPG tanks will vary based on the specific installation. Consult factory.

DS-/DL/F-Model Performance Curves Power Required vs Capacity All F-, DS-, DL-Models Flow vs. Power Required. 88 RPM @ Hz. Power Required (kw). Model Model Model Model Model. 7 Capacity (L /min) Flow vs. Differential Pressure RPM @ Hz Power Required (hp) Model Model Model Model Model Model 9 8 8 8 8 Capacity (gpm) The performance curves are based on aboveground LPG installations. Performance curves for underground LPG tanks will vary based on the specific installation. Consult factory. 7

Model Performance Curves Example @ 88 RPM Differential Pressure. bar. psi Flow 8 L/min. gpm Power Required. kw.8 hp DIFFERENTIAL PRESSURE PSI BAR... 7.. Curves based on LPG* Capacity Power required... 7.. KW... 7.. HP... LPM GPM CAPACITY 7. Curves based on LPG* 7. Example @ RPM Differential Pressure. bar. psi Flow 8 L/min. gpm Power Required. kw 8. hp DIFFERENTIAL PRESSURE PSI BAR... 7.. Capacity Power required... 7.. KW... 7.. HP... LPM GPM CAPACITY The performance curves are based on aboveground LPG installations. Performance curves for underground LPG tanks will vary based on the specific installation. Consult factory. P.O. Box 8, Oklahoma City, OK 77 U.S.A. 8 N.W. th St., Oklahoma City, OK 7 Phone () 9-7 Fax () 98-7 E-mail info.corken@idexcorp.com Web address http://www.corken.com Printed in the U.S.A. November